Factory Settings on Delivery Telephony Functions
2.
Factory Settings on Delivery
The following basic settings and features are active on delivery. We recommend that you configure the OpenCom 107 to your individual requirements before
putting it into operation (see Configuration starting on page 40).
2.1
Telephony Functions
■ The S
0
1 port is configured for multi-terminal access, the S
0 access.
2 port for system
■ The S
0
3 and S
0
4 ports are configured as internal S
0
buses with the call numbers
20 and 21.
■ The four U pn
ports are configured for OpenPhone 63 system telephones with the call numbers 30 to 33.
■ The four a/b ports are configured for analogue devices with the call numbers
10 to 13.
■ The OpenCom 107 is configured ready for operation in Germany.
■ Analogue devices: The dialling mode (pulse dialling or DTMF) is automatically detected.
■ All corded terminals connected ring when there are incoming external calls.
■ The system PIN, for example for remote-programmable call diversion, is set at
“0000”.
2.2
Authorisations
The use of functions by a terminal on the OpenCom 107 is regulated by means of authorisations. Authorisation is configured by means of user groups to which the users with their terminals are then assigned.
Three user groups are preset: “Administrators”, “Standard” and “Guests”. “Administrators” have access to all functions of the OpenCom 107 and unrestricted configuration rights. Users in the “Guests” group cannot configure the OpenCom 107, are
12
Factory Settings on Delivery Authorisations not able to make external calls, and have only restricted use of the terminal functions of the OpenCom 107. The “Standard” user group, because of its default settings, is well suited as a starting point for the creation of user groups for normal users of the system (e.g. the staff members of a company).
Note: When the OpenCom 107 is commissioned, all connected terminals are initially in the “Administrators” group until a user logs on to the Web console. Subsequently, all terminals are automatically in the “Guests” group (see also the
groups, refer to the online help in the chapter entitled “User
Manager”.
The following terminal functions are factory preset to the “Administrators” group:
■
External line access: international numbers can be dialled from all configured telephones. External lines must be seized by entering a prefixed code.
■
Least cost routing is not active. As soon as LCR is configured, users can make calls via individually selected call-by-call providers.
■
“VIP call” is activated.
■
Announcements to system telephones are possible.
■
Baby calls can be configured.
■
If a call key is configured for a user on more than one terminal, he can program this key for more than one outgoing call, i.e. he can use his various terminals to make parallel calls from this telephone number.
■
“Pick-up” and “Pick-up selective” of calls from other telephones are activated.
Pick-up protection is deactivated.
■
“Call removal” is deactivated.
■
Callback (on busy) can be activated.
■
If more than one terminal is configured for a user under the same number, they can suppress the signalling of calls on the parallel terminals.
13
Factory Settings on Delivery Authorisations
■
Function “Reaction: Connection will be disconnected” is deactivated as callers trying to reach a terminal that cannot be reached or is busy will hear a busy signal.
■
The “call queue” function is deactivated.
■
Call forwarding to internal or external numbers can be activated. Call forwarding after delay is executed after 20 seconds. Door calls and MSN groups can be forwarded. Call forwarding for other users and call forwarding by other users are deactivated.
■
It is possible to transfer an external call to an external subscriber.
■
Three-party conferences can be set up.
■
Connections can be parked.
■
Call protection can be activated, call-waiting protection, announcement protection and pick-up protection can not be activated.
■
Transmission of one’s own phone number (MSN or system access number) can be suppressed on a per-call basis.
■
The telephone lock can be activated. The terminal PIN is “0000”.
■
Interception of “malicious” callers is possible if this feature has been ordered from the network operator.
■
The white list, black list and call filters are not preconfigured and thus not active. If these lists are configured, they can be activated for the user groups. A special list with emergency telephone numbers is preset and activated.
■
Call lists on terminals list internal calls, external calls, calls from the door and calls that the user received while they were telephoning.
■
Function keys can be programmed on system telephones, no keys are locked.
■
The evaluation of connection data by external cost-recording programs is deactivated.
■
The cost multiplier is set to 100%, i.e. the costs are not multiplied by any factor.
There are no preset basic amounts for the charging of calls.
14
Изтегляне