Installation. Aastra DeTeWe OPENPHONE 52, OpenPhone IPC, OpenCom 100 OpenCom 130, OpenCom 131, OpenCom 150, OpenCom 510, OpenPhone 71, 73, 75, OpenPhone 61, 63, 65, RFP 22, RFP 24, DECT, OpenCom 100 OpenCom 107, OpenPhone 27, OpenCTI 50
Reklāma
Reklāma
Voice over IP (VoIP) OpenPhone IPC
You will not need a licence to install OpenPhone IPC but you will require a licence to operate it with the OpenCom 107. Unit licences, enabling the simultaneous operation of a certain number of OpenPhone IPCs, are available.
The licences are activated in the OpenCom 107’s Configurator in the Menu
SYS Configuration: Licences. The system software includes a licence for a demo version for temporary use (60 days). Please contact your local agent or DeTeWe representative if you wish to purchase a permanent licence. Licences can be combined. Each licence can be activated only once.
8.5.1 Installation
Installation is done using a setup program. The OpenPhone IPC can also be installed without a user interface. The program can then be used via a CTI application (Net-TAPI or OpenCTI).
Start the installation program from the OpenPhone IPC product CD and follow the installation assistant’s instructions.
8.5.2 Configuration
Analogue to the VoIP system telephones, the OpenPhone IPC creates multiple IP connections to the OpenCom 107. When you start the program for the first time, the Options dialogue is automatically opened. Here you must configure the following values:
1. Enter in the VoIP IP Address field the OpenCom 107’s IP address.
2. Enter six hexadecimal-digits into the Device ID field. This device ID is not a
MAC address, so overlapping with existent MAC addresses is possible. The device ID is configured in the Configurator, on the PBX Configuration:
Devices: VoIP Phones page.
3. Confirm with OK.
Notes
VoIP system telephony requires an active IP connection to a workplace computer.
If a Firewall is installed for your workplace computer, you may need to explicitly allow this connection.
81
Voice over IP (VoIP) OpenPhone IPC
If you log on to the workplace computer using a different user name, you must reconfigure these values.
You can use any arbitrary sequence of digits not already in use in the LAN for the device ID. Select a random device ID to secure telephone usage. The device ID can only be read on the Web console.
The displayed menu texts and parts of the operations software are elements of the
OpenPhone IPC installation, but they can be loaded from the OpenCom 107 via
TFTP. where necessary