1.1 Safety Checklists. Alpha Novus FXM 650


Add to my manuals
60 Pages

advertisement

1.1 Safety Checklists. Alpha Novus FXM 650 | Manualzz

1.1 Safety Checklists

1.1.1 UPS Safety Checklist

FXM UPS Operator's Manual

1.1 Safety Checklists

1.1.1 UPS Safety Checklist

This Uninterruptible Power Supply (UPS) must be installed in a restricted access location, and by trained personnel qualified in the safe use of high-energy power supplies and their batteries. Also assumed is knowledge of the local electrical code(s) and their safe application.

This Uninterruptible Power Supply (UPS) is suitable for installation as part of the

Common Bonding Network (CBN) as defined in GR-1089-CORE.

DANGER: NEVER let water from rain, a hose, tap or a sprinkler’s output, road splash or other water sources enter the UPS to prevent accidental shorts, shocks or electrocutions.

F

F

F

F

F

F

F

F

F

F

F

Do not work alone under hazardous conditions.

Read this manual. If you have any questions about safe installation, operation or maintenance, contact Alpha Technologies’s customer service department.

Carefully unpack the components. Report any shipping or other damage at once.

Always assume electrical connections or conductors are live. Turn off all circuit breakers and double-check with a voltmeter before performing installation or maintenance.

Before installation, verify the input voltage and current requirements of the load are met by the UPS’s output (See specifications). Verify the line voltage and current meet the UPS’s input requirements.

Place a warning label on the utility panel to tell emergency personnel a UPS is installed.

Use proper lifting techniques when lifting or moving the UPS or its components.

This UPS has more than one live circuit. AC power may be present at the outputs even if the UPS is disconnected from line or battery power.

This UPS can be operated to a maximum operating temperature of 55°C except for the

FXM 2000–120VAC unit which has a maximum temperature rating of 50°C. Also see the specifications section for temperature ratings and deratings.

At high ambient temperature conditions, the UPS’s surface can be very hot to the touch.

There is a Lithium battery inside the UPS. There is a danger of an explosion if it is incorrectly replaced. Replace it only with the same type or an equivalent battery as recommended by the manufacturer. Dispose of the old battery as instructed by the manufacturer.

2 Doc# 017-201-B0 Rev 05/07

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals