V4

CONNECTION DIAGRAM

D8 MAIN BOARD

TELEPHONE

AUX1

AUX2

ARM1

ARM2

12V

0V

J2 CONNECTOR

NESS RADIO INTERFACE

(Optional)

J1 LINK

BOX TAMPER & PROGRAM LINK

= Sealed, normal state

= Tamper alarm state

Power up with link off to enter installer program mode

BOX TAMPER LEADS

(supplied)

J3 HEADER

Provides Open Collector outputs as marked.

BOX TAMPER SWITCH

N.C. Contacts (WHITE)

(supplied)

“HEARTBEAT”LED

Constantly flashes

BATTERY LEADS

(supplied)

SIREN

AC

17V

AC

EARTH

C

Z3

Z2

C

Z1

0V

+12V

DAT

CLK

COM

TAMP

0V

+12V

Z8

C

Z7

Z6

C

Z5

Z4

+12V

RESET

STR

TELEPHONE LEAD (Supplied)

Connect to Mode3 socket

N.O TAMPER SWITCH

(761-002) Colour: BLACK

Supplied with Ness siren covers

2K2

ALTERNATIVE TAMPER SWITCH WIRING

For N.C. Tamper Switches

N.C TAMPER SWITCH (SWI920) Colour: WHITE

2K2

Zone 8

Zone 7

Zone 6

Zone 5

Zone 4

Zone 3

Zone 2

Zone 1

12V DC Power for detectors, etc

Zone

C

Zone

C

ZONE CONNECTION

2K2

2K2

(

NORMALLY CLOSED

( N.C.) DEVICES

NORMALLY OPEN

N.O.) DEVICES

17V AC (Red & Black)

EARTH (White)

12V DC Power for detectors, etc

NESS LED Keypad

(100-192)

DAT

CLK

COM

+12V

Up to 2 x Ness 12V Siren (100-172)

OR 3 x Top Hat Screamer (100-238)

Up to 2 x Strobe Light (NOI-300)

Up to 3 x Horn Speaker, 8 Ohm (NOI-110)

NESS LCD Keypad

(100-667)

Maximum

3 keypads

Ness 17V AC Plug Pack (840-029)

(Australia only)

BATTERY CONNECTION

Connect 12V 7Ah backup battery

HEATSINK

NORMALLY OPEN

Tamper Switch

Part No: 761-002

Colour: Black

TAMPER SWITCH IDENTIFICATION

NORMALLY CLOSED

Tamper Switch

Part No: SWI920

Colour: White

6

The NORMALLY OPEN Tamper Switch is readily identified being black in colour.

This tamper switch is now being to supplied as standard with all Ness siren covers.

The Normally Open contacts are less prone to flase activation in harsh climates.

The standard white NORMALLY CLOSED

Tamper Switch is supplied with all Ness control panels for box tamper.

NESS D8 (V4.5) CONTROL PANEL – INSTALLER MANUAL

advertisement