P R O G R A M M I N G
OPTION No
P47E
P49E
DESCRIPTION
Codes 1-8 to AREA1
Codes 1-8 to AREA2
User Code 1 User Code 2 User Code 3 User Code 4 User Code 5 User Code 6 User Code 7 User Code 8
ON
1E
ON
2E
ON
3E
ON
4E
ON
5E
ON
6E
ON
7E
ON
8E
ON
ON = Factory default setting.
OPTION No
P48E
P50E
DESCRIPTION
Codes 9-15 to AREA1
Codes 9-15 to AREA2
User Code 9 User Code 10 User Code 11 User Code 12 User Code 13 User Code 14 User Code 15
ON
1E
ON
2E
ON
3E
ON
4E
ON
5E
ON
6E
ON
7E
P47E, P48E
DESCRIPTION:
Area 1 User Codes
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
All User Codes assigned to Area 1
P49E, P50E
DESCRIPTION:
Area 2 User Codes
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
User Code 1 (Master Code) assigned to
Area 2.
NOTES:
• User Codes can be assigned to either a single Area or to both Areas.
• If a User Code is assigned to NO Areas, the code is effectively disabled and will not operate the panel.
• To make a User Code arm or disarm just one Area, assign that code only to the required Area.
• Assigning User Codes to Areas has no effect unless zones are also assigned to
Areas.
• For this option [Zone No] E toggles the selection ON and OFF.
ASSIGNING USER CODES TO AREAS
Assign (or remove) User Codes to Areas.
PROGRAMMING SEQUENCE:
P47E 1E–8E toggles the options ON and OFF
Assigns User Codes 1–8 to AREA1
P48E 1E–7E toggles the options ON and OFF
Assigns User Codes 9–15 to AREA1
P49E 1E–8E toggles the options ON and OFF
Assigns User Codes 1–8 to AREA2
P50E 1E–7E toggles the options ON and OFF
Assigns User Codes 9–15 to AREA2
EXAMPLE:
To assign User Codes 1–8 to AREA1 and User Codes 9–15 to AREA2.
P47E turn ON lights 1–8
P48E turn OFF lights 1–7
P49E turn OFF lights 1–8
P50E turn ON lights 1–7
User Codes
AREA 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
EXAMPLE:
User codes 1–8 are assigned to AREA 1.
P47E User Codes 1-8 P48E User Codes 9-15
User Codes
AREA 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
EXAMPLE:
User codes 9–15 are assigned to AREA 2.
P49E User Codes 1-8 P50E User Codes 9-15
NESS D8 (V4.5) CONTROL PANEL – INSTALLER MANUAL
21
P R O G R A M M I N G
ZONE TO OUTPUT MAPPING
When a zone alarms, it can turn on any or all of the following 6 outputs: Sonalert,
Strobe, Siren, Reset, AUX1, AUX2.
The programming is selected with options P54E – P59E. Simply set the zone number to the output to select it. The zone LED will indicate if the zone is selected.
The Tamper Input and the Keypad Panic can be programmed to turn on the Reset,
Strobe, Sonalert and Siren by using option P61E.
NOTE: Zone To Output Mapping applies to zones when the panel is in the Armed or 24hr state.
For MONITOR and DAY mode
Output Mapping – see Option
P63E 1E–8E, page 28
OPTION No
P54E
P55E
P56E
P57E
P58E
P59E
DESCRIPTION
Reset zones
Strobe zones
Sonalert zones
Siren zones
Aux1 zones
Aux2 zones
Zones
1 2 3 4 5 6 7 8
ON ON ON ON ON ON ON ON
ON ON
ON ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON ON ON ON ON ON ON ON
ON ON
ON ON
ON ON ON ON ON ON
ON ON ON ON ON ON
ON = Factory default setting
P51~P53E, page 19
P54E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT: all ON: All zones trigger Reset output
NOTES:
• 0E will turn all selections OFF
MEMORY E will turn all selections ON
RESET OUTPUT ZONES
Selects the zones to trigger the Reset output.
PROGRAMMING SEQUENCE:
P54E [Zone No]E toggles the options ON and OFF
P54E [Zone No]E OFF: The zone will not trigger the Reset output
P54E [Zone No]E ON: The zone will trigger the Reset output
P55E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT: all ON: All zones trigger Strobe output
NOTES:
• 0E will turn all selections OFF
MEMORY E will turn all selections ON
P56E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT: all ON: All zones trigger Keypad Sonalert
NOTES:
• 0E will turn all selections OFF
MEMORY E will turn all selections ON
STROBE OUTPUT ZONES
Selects the zones to trigger the Strobe output.
PROGRAMMING SEQUENCE:
P55E [Zone No]E toggles the options ON and OFF
P55E [Zone No]E OFF: The zone will not trigger the Strobe output
P55E [Zone No]E ON: The zone will trigger the Strobe output
KEYPAD SONALERT ZONES
Selects the zones to trigger the Keypad Sonalert (beeper).
PROGRAMMING SEQUENCE:
P56E [Zone No]E toggles the options ON and OFF
P56E [Zone No]E OFF: The zone will not trigger the Keypad Sonalert
P56E [Zone No]E ON: The zone will trigger the Keypad Sonalert
22
NESS D8 (V4.5) CONTROL PANEL – INSTALLER MANUAL
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 Introduction
- 4 Features
- 4 Specifications
- 5 Packing list
- 5 Installation procedures
- 6 CONNECTION DIAGRAM
- 7 Wiring examples
- 10 Keypad
- 11 OPERATION SUMMARY
- 12 Quick start Programming
- 13 How to enter Program Mode
- 13 Program mode levels
- 14 USER CODES
- 15 Timers
- 16 Vibration Sensitivity
- 19 Zone Assignment
- 21 AREA PARTITIONING
- 23 Zone To Output Mapping
- 25 Various Options
- 26 Tamper/Keypad Panic Output Mapping
- 27 System Operation Shortcuts
- 28 MONITOR MODE OUTPUT MAPPING
- 28 Day mode output mapping
- 29 Miscellaneous Options
- 31 SUPERVISED RADIO ZONES
- 31 Supervision time
- 33 Radio Supervision Alerts
- 35 Misc. options
- 38 Telephone Numbers
- 38 Account Number
- 39 Telephone Number 3 – Test Calls
- 39 Telephone Number 4 – Callback
- 39 Follow me Telephone Number
- 40 Report zone alarms
- 40 Report zone restorals
- 40 Report multiple zone alarms
- 40 Account No.2 zones
- 41 Report Miscellaneous alarms
- 41 Report Miscellaneous Restorals
- 41 Restoral Reporting options
- 42 Test Call Interval
- 42 Time before Next test call
- 42 Dialling Method
- 43 Disable Dialler
- 43 Contact ID format
- 43 Audible DTMF format
- 43 Audible Pulse format
- 44 Contact ID Reporting Codes
- 45 Alternate Dialling
- 45 Check for dial tone
- 45 Number of Dialling Attempts
- 46 Area1 open/close reports
- 46 Area2 open/close reports
- 46 Siren Chirp on kiss-off
- 46 Strobe Flash on kiss-off
- 47 Forced Opening Report
- 47 Delay Closing Report
- 47 Manual Exclude Report
- 47 Auto Exclude Report
- 48 Enable Test Calls
- 48 Mains Report Delay
- 48 Listen-in to dialler
- 49 Swinger Shutdown
- 49 Line Fault Monitor
- 49 Line Fault to AUX
- 50 Remote access
- 50 Direct Connect
- 51 Remote access options
- 52 Required Rings
- 53 Clear Radio Devices
- 53 Clear Memory
- 53 Clear Panel Options
- 53 Clear User Codes
- 54 Radio Quick Start
- 54 Ness Radio Interface
- 54 Signal strength meter
- 55 Radio Devices, Operation
- 55 Radio Supervision, Defined
- 56 Radio Device Programming
- 57 Radio Key Programming
- 58 Audible Monitoring Operation
- 59 Remote Operation by Telephone
- 60 Ness Accessories
- 61 Wireless Products
- 62 PROGRAMMING OPTIONS SUMMARY
- 63 Installation Record