D8 V4 Installers Manual (rev 4.5)


Add to my manuals
64 Pages

advertisement

D8 V4 Installers Manual (rev 4.5) | Manualzz

P91E

PROGRAM MODE LEVEL:

Installer, Remote by PC

FACTORY DEFAULT:

1

NOTES:

• RELATED OPTIONS:

P90E 1E to 8E (All Remote Access options)

P R O G R A M M I N G

OPTION No

P91E

DESCRIPTION

Required Rings to answer

DEFAULT

1

NOTE

REQUIRED RINGS

Sets the number of double-rings before an incoming call is answered. This is used for Remote Access.

Programmable from 1 to 16 rings. Enter a value between 1 and 16.

See below for a detailed description.

PROGRAMMING SEQUENCE:

P91E existing Required Rings value is displayed

[ENTER NEW VALUE] E new Required Rings value is displayed

EXAMPLE: To make Required Rings = 3:

P91E3E

P66666666E

PROGRAM MODE LEVEL:

User Program Mode

FACTORY DEFAULT:

[not applicable]

P77777777E

PROGRAM MODE LEVEL:

Installer, User Program Mode

FACTORY DEFAULT:

[not applicable]

P88888888E

PROGRAM MODE LEVEL:

Installer, User Program Mode

FACTORY DEFAULT:

[not applicable]

P99999999E

PROGRAM MODE LEVEL:

Installer, User Program Mode

FACTORY DEFAULT:

[not applicable]

SEND DIALLER TEST REPORT

Send a Dialler Test Report in USER PROGRAM MODE. Obviously, at least one telephone number must be programmed (P70E).

PROGRAMMING SEQUENCE:

P66666666E (eight 6’s) Triggers dialler and sends test report to Central Station

SIREN TEST

Turn the Siren, Reset and Strobe Outputs On. Pressing P E will stop the Siren Test (and also exits Program Mode).

PROGRAMMING SEQUENCE:

P77777777E (eight 7’s) Triggers Siren, Reset, Strobe

PANEL RESET

This function resets the microprocessor. The effect is the same as powering down and powering up again.

PROGRAMMING SEQUENCE:

P88888888E (eight 8’s) Panel Reset

PANEL SOFTWARE VERSION

This function displays the panel software version when in program mode. Displayed in decimal format by the zone LEDs.

Example, version 4.5 is displayed by flashing 4 followed by 5.

PROGRAMMING SEQUENCE:

P999999999E (eight 9’s) Displays software version

52

NESS D8 (V4.5) CONTROL PANEL – INSTALLER MANUAL

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project