Robert K.
Where are the P1, P2, and P3 buttons located?
The P1, P2, and P3 buttons are located inside the housing of the POA1 control unit.
Below you will find brief information for Swing gate motor PP 7024, Swing gate motor PP 7224. The PP7024 is a gearmotor for small and medium-sized swing gates. It automates gates with leaves of a maximum 2m in length and 200 kg in weight. PP7024 is equipped with a control unit and a 230V power supply. The PP7024/V1 version has a 120V power supply. The PP7224 has no control unit and connects to the PP7024 control unit.
Advertisement
Advertisement
For swing gates Pop Instructions and warnings for the fitter Istruzioni e avvertenze per l’installatore Instructions et recommandations pour l’installation Anweisungen und hinweise für den installateur Instrucciones j advertencias para el instalador Instrukcja dla instalatora 1 2 3 5 4 3 3 6 8 4 7 1 2 5 6 7 7 8 9 10 A B 4 7 5 6 3 2 1 11 12 13 14 PP7024 PP7224 15 Pop Table of contents: 1 GB page 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 Installation Preliminary checks Typical system Mounting Mounting the motor bracket to the pillar Assembly of the straight arm Mounting the gearmotor Assembling the curved arm and mounting the adjustable bracket to the leaf 2.8 Releasing the gearmotor from the inside 2.8.1 Releasing the gearmotor from the outside (optional) 2.9 Securing the opening stop 2.10 Electrical connections 2.11 Connection to the power supply 2.12 Using buffer batteries (optional) page 2 3 Manual or release manoeuvre 3 2 2 2 2 3 3 3 3 4 4.1 Testing and commissioning Testing 4 4 5 5.1 4 4 6 Technical characteristics 4 7 Accessories 4 Instructions and warnings for users of the POP gearmotor 5 3 3 3 3 3 3 Warnings Read these instructions before proceeding with the installation, as they provide important information regarding safety, installation, use and maintenance. In order to make the use of these instructions as simple as possible, we have tried to follow the same order as the various phases of installation. Anything which is not specified in these instructions is not allowed, any unspecified use may damage the product and place people and objects in danger. Nice disclaims any liability for the non-observance of good practice in the manufaturing of the gates, as well as any buckling which may occur during use. Store this manual safely for future use This manual, as well as the design and manufacture of the devices that make up POP, comply fully with the standards and regulations in force Considering the hazards that may exist during the installation and operation of POP, it is necessary that also the installation be carried out in strict compliance with current legislation, standards and regulations, particularly: • Before you start with the installation, check whether additional devices or materials are needed to complete the automation with POP based on the specific application requirements. • The automation system must not be used until it has been commissioned as described in paragraph “Commissioning”. • The packing materials must be disposed of in compliance with local regulations. • Do not make modifications to any components unless provided for in this manual. This type of operations will only cause malfunctions. NICE disclaims any liability for damage resulting from modified products. • Do not immerse the automation parts in water or any other liquid. During installation, ensure that liquids do not leak into the control unit or other open devices. • In the event that liquid substances have penetrated inside the automation devices, immediately disconnect the power supply and contact the NICE customer service department. The use of POP in these conditions can be dangerous. • Keep all components of POP away from heat sources and open flames; these could damage the components and cause malfunctions, fire or dangerous situations. • During long periods of inactivity, the optional battery should be removed and stored in a dry location to prevent leakage of noxious substances. • Connect the control unit only to a power supply line equipped with safety grounding system. • All operations requiring the opening of the shells of POP device must be performed with the control unit disconnected from the power supply; if the disconnection device is not identifiable, post the following sign on it: “WARNING: MAINTENANCE WORK IN PROGRESS”. • In the event that any automatic switches or fuses are tripped, you must identify the failure and eliminate it before you reset them. • If a failure occurs that cannot be solved using the information provided in this manual, refer to the NICE customer service department. 1 1) Product description POP is a gearmotor for small and medium-sized swing gates. It automates gates with leaves of a maximum 2m in length and 200 kg in weight. • PP7024 with incorporated control unit and 230V power supply (The PP7024/V1 version has a 120V power supply.) • The PP7224 has no control unit, the PP 07224 gearmotor is connects with the PP7024 control unit. 2) Installation The installation must be carried out by qualified and skilled personnel in compliance with the directions provided in chapter “WARNINGS”. 2.1) Preliminary checks Do not use POP to automate a gate that is inefficient and unsafe. The device does not solve faults resulting from incorrect installation or poor maintenance of the gate. Make sure that the structure of the gate is suitable for automation and in compliance with regulations in force. Make sure that: • The packing is undamaged and contains all the parts shown in Fig. 1 o No.1 pc. PP7024 o No.1 pc. PP7224 o No.2 pcs. Straight arm o No.2 pcs. curved arm o No.2 pcs. Motor bracket o No.1 pc. Box of accessories. o No.1 pc. Electronic “Openkit” box • The gate opens and closes without presenting points of friction. • The gate is well balanced, i.e., if it is stopped in any position it must not display a tendency to start moving again. • The area singled out for mounting the gearmotor allows easy, safe manoeuvring. • Make sure that the mounting area is compatible with the overall dimensions of the gearmotor (Fig. 2). • Make sure that the mounting positions of the various devices are protected from impacts and that the mounting surfaces are sufficiently sturdy. • Make sure that the mounting surfaces of the photocells are flat and that they enable the proper alignment between TX and RX. • Check that there is enough space for the arm to rotate (Fig. 3). 2.2) Typical system (Fig. 4) 1. 2. 3. 4. POP “PP7024” actuator POP “PP7224” actuator Photocell Aerial 5. 6. 7. 8. Flashing light Key-operated selector switch Post for photocells (optional) Power supply line 2.3) Mounting (Fig. 5) Mount the brackets as follows: Tab. 1 Fig. 5 1. Using the leaf opening angle as a guideline, check that the values in Tab. 1 can be met. 2. Measure the value of “A” on site. 3. The value of “B” can be calculated from Table 1 using the value of “A” together with the opening angle of the leaves. For example, if “A” is 100mm and a 100° opening is required, the value of “B” should be approximately 180mm. 2 2.4) Mounting the motor bracket to the pillar (Fig. 6) GB Use screws which are suitable for the material the pillar is made of. Mount the bracket horizontally. 2.5) Assembly of the straight arm (Fig. 7) Use the M8x55 screw with its relative grower washer. Make sure the arm is positioned by making it come out of the front part. 2.6) Mounting the gearmotor (Fig. 8) Insert the POP in the plate at point C and mount it onto the former using M6x100 screws and the nuts supplied. 2.7) Assembling the curved arm and mounting the adjustable bracket to the leaf (Fig. 9) Using the pins supplied, and the corresponding safety rings, fasten the bent arm to the straight arm, and the leaf mounting bracket to the bent arm. Fasten the leaf mounting bracket to the gate as far away as possible from the post, extending the arms to their maximum reach (Fig. 5). The bracket can be welded to the gate or fastened with screws suited to the gate material. 2.8) Releasing the gearmotor from the inside (Fig. 10) This is carried out in two steps: A: lift the cover. B: insert the release key supplied and turn it clockwise until it stops. 2.8.1) Releasing the gearmotor from the outside (Fig. 11) (optional) The release system is assembled in six steps: A: remove the plastic cover (1) B: screw the pin (3) onto the release shaft (2) C: screw the cable stretcher (4) into the special hole (5) D: secure the spring (6) to the pin (3) and to the fastening point visible in the shell. E: slide the release cable (7) into the pin hole (3) and cable stretcher (4). F: replace the plastic cover (1) to its original position. 2.9) Securing the opening stop (Fig. 12) Release the gearmotor. A: rotate the leaf to the “gate open” position required. Then place the limit switch on the strike (the arm must be straight) and fasten it with two Mx25 screws. B: loosen the screw which fastens the straight arm to the gearmotor, and fit the protective cover. Insert and tighten the screw which had been removed. 2.10) Electrical connections Consult the Control Unit POA1 instruction booklet for the electrical connections. 2.11) Connection to the power supply (Fig. 13) On PP7024: connect the 230V supply cable directly to the fuse holder terminal. On PP7224: connect the cable from the PP7024 unit to the mammoth terminal. 2.12) Using buffer batteries (Fig. 14) (optional) POP comes complete with housing for buffer batteries (optional). Break open the plastic cap on the control unit box in order to connect the box with the battery. 3) Manual or release manoeuvre The manual operation (Fig. 10) must be resorted to in case of power failures or system malfunctions. The manual manoeuvre only allows the gearmotor to travel freely if it is assembled correctly, complete with original accessories. 3 4) Testing and commissioning These are the most important operations, designed to guarantee the maximum safety of the automation system. The testing procedure can also be used as a periodic check of the devices that make up the automation. The testing of the automation system must be performed by qualified and experienced personnel who must establish what tests should be conducted based on the risk involved, and verify the compliance of the system with applicable regulations, legislation and standards, in particular with all the provisions of EN standard 12445 which establishes the test methods for gate automation systems. 4.1) Testing 1. Make sure that the provisions contained in the chapter “WARNINGS” have been carefully observed. 2. Test the opening and closing of the gate and make sure that the leaves move in the intended direction. The test should be carried out a number of times to make sure that the gate moves smoothly, that there are no points of excessive friction and that there are no defects in the assembly or adjustments. 3. Check the proper operation of all the safety devices, one by one. 4. Measure the impact force according to EN standard 12445. If “motor force” control is used to assist the system for the reduction of the impact force, try to find the adjustment that gives the best results. 5) Maintenance The maintenance operations must be performed in strict compliance with the safety directions provided in this manual and according to the applicable legislation and standards. POP does not require any special maintenance. However, periodically make sure (at least once every six months) that all the devices are perfectly efficient. To this end, carry out all the tests and checks described in paragraph 4.1 “Testing”. If other devices are present, follow the directions provided in the corresponding maintenance schedule. 5.1) Disposal POP is constructed of various types of materials, some of which can be recycled (aluminium, plastic, electric cables), while others must be disposed of (electronic boards). ! WARNING: some electronic components may contain polluting substances; do not pollute the environment. Enquire about the recycling or disposal systems available in compliance with regulations locally in force. 1. Disconnect the automation system from the electric mains. 2. Disassemble all the devices and accessories, following in reverse order the procedures described in chapter 2 “Installation”. 3. Remove the electronic board. 4. Sort the various electrical and recyclable materials and consign them to licensed firms for recovery and disposal. 5. Consign the remaining materials to authorized scrap collection centres. 6) Technical characteristics Power supply Max. current Motor power Torque Opening time Operating temperature Protection class Work cycle Insulation class * This version does not have a control unit. 7) Accessories KIO - Key-operated selector switch with cord-type release 4 Vac/Hz Vdc A W Nm s °C PP7024 PP7024/V1 PP7224* 230/50 / ~1 120/50-60 / ~2 75 180 10 -20°÷50° IP 44 30% / 24 3 1 B ✄ For swing gates GB Pop Instructions and warnings for users of the POP gearmotor Congratulations for having chosen a Nice product for your automation system! Nice S.p.a. produces components for the automation of gates, doors, rolling gates, roller shutters and awnings: gearmotors, control units, radio controls, flashing lights, photocells and miscellaneous accessories. Nice uses only the finest materials and first-class workmanship. It focuses on the development of innovative solutions designed to simplify the use of its equipment, dedicating meticulous care to the study of its technical, aesthetic and ergonomic characteristics. From the wide range of Nice products, your installation technician will certainly have selected the one best suited to your specific requirements. However, Nice is not the producer of your automation system, which is rather the result of a combination of operations carried out by your installation technician, namely analysis, evaluation, selection of materials and system implementation. Each automation system is unique. Your installation technician is the only person who possesses the experience and professionalism needed to set up a system capable of satisfying your requirements, a system that is safe, reliable, long lasting and built in accordance with the regulations in force. An automation system is not only very convenient; it also improves the level of security in your home. Moreover, it will last for years with very little maintenance. Even though the automation system you possess meets the safety requirements of the legislation in force, this does not exclude the existence of a “residual risk”, i.e. the possibility that dangers may arise, usually as a result of improper or unreasonable use. We have prepared the following list of do’s and don’ts to help you avoid any mishaps: • Before using your automation system for the first time, ask the installer to explain the origin of any residual risks; take a few minutes and read the users instructions manual given you by the installer. Retain the manual for future use and deliver it to any subsequent owner of the automation system. • Your automation system is a machine that will faithfully execute your commands; unreasonable or improper use may generate dangers: do not operate the system if there are people, animals or objects within its range of operation. • Children: automation systems are designed to guarantee high levels of safety and security. They are equipped with detection devices that prevent movement if people or objects are in the way, guaranteeing safe and reliable activation. However, children should not be allowed to play in the vicinity of automated systems; to prevent any accidental activations, keep all remote controls away from children: they are not toys! • Malfunctions: If you notice that your automation is not functioning properly, disconnect the power supply to the system and operate the manual release device. Do not attempt to make any repairs; call the installation technician and, in the meantime, operate the system like a non-automatic gate after releasing the gearmotor as described below. • Maintenance: Like any machine, your automation needs regular periodic maintenance to ensure its long life and total safety. Arrange a periodic maintenance schedule with your installation technician. Nice recommends that maintenance checks be carried out every six months for normal domestic use, but this interval may vary depending on the intensity of use. Only qualified personnel are authorized to carry out checks, maintenance operations and repairs. • Do not modify the system or its programming and adjustment parameters in any way, even if you feel capable of doing it: your installation technician is responsible for the system. • The final test, the periodic maintenance operations and any repairs must be documented by the person who has performed them; these documents must remain under the custody of the owner of the system. • Disposal. At the end of its useful life, the automation must be dismantled by qualified personnel, and the materials must be recycled or disposed of in compliance with the legislation locally in force.. • In the event of malfunctions or power failures. While you are waiting for the technician to come (or for the power to be restored if your system is not equipped with buffer batteries), you can operate the system like any non-automatic gate. In order to do this you need to manually release the gearmotor: this operation, which is the only one that the user of the automation is authorized to perform, has been carefully designed by Nice to make it extremely easy, without any need for tools or physical exertion. Releasing the gearmotor from the inside 1. Lift the cover. 2. Insert the release key supplied and turn it clockwise until it stops. 1 2 Releasing the gearmotor from the outside (optional) • Remove the plastic cover (1) • Screw the pin (3) onto the release shaft (2) • Screw the cable stretcher (4) into the special hole (5) • Secure the spring (6) to the pin (3) and to the fastening point in the shell. • Slide the release cable (7) into the pin hole (3) and cable stretcher (4) • Replace the plastic cover (1) to its original position. 4 7 5 6 3 2 1 Important: if your system is equipped with a radio control that, after a period of time, seems not to work as well, or not to work at all, it may simply be that the battery is exhausted (depending on the type of battery, it may last from several months up to two or three years). In this case you will see that the light confirming the transmission is weak, or does not come on, or comes on only briefly. Before calling the installation technician try exchanging the battery with one from another operating transmitter: if the problem is caused by a low battery, just replace it with another of the same type. 6 Are you satisfied? If you wish to install another automation system in your home, call your old installation technician and use Nice products. You will get the services of a specialist and the most advanced products available on the market, superior performances and maximum system compatibility. Thank you for reading these instructions. We feel confident that you will be well satisfied with your new system. For any present or future requirements, please contact your reliable installation technician. Pop Indice: 1 I pag. 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 8 3 9 8 8 8 8 9 9 9 9 4 4.1 10 10 5 5.1 10 10 6 Caratteristiche tecniche 10 7 10 11 9 9 9 9 9 9 7 5. 6. 7. 8. Tab. 1 Fig. 5 8 I 9 10 Vac/Hz Vdc A W Nm s °C PP7024 PP7024/V1 PP7224* 230/50 / ~1 120/50-60 / ~2 75 180 10 -20°÷50° IP 44 30% / 24 3 1 B ✄ II 1 2 4 7 5 6 3 2 1 12 page 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 page 14 3 15 14 14 14 14 15 15 15 15 4 4.1 16 16 5 5.1 16 16 6 16 7 16 17 15 15 15 15 15 15 • • • • • • • • 13 F 5. 6. 7. 8. Tab. 1 Fig. 5 14 F 15 16 Vca/Hz Vcc A W Nm s °C PP7024 PP7024/V1 PP7224* 230/50 / ~1 120/50-60 / ~2 75 180 10 -20°÷50° IP 44 30% / 24 3 1 B ✄ F 1 2 4 7 5 6 3 2 1 18 Pop S. S. 1 20 3 21 20 20 20 20 21 21 21 21 4 4.1 22 22 5 5.1 22 22 6 22 7 22 23 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 21 21 21 21 21 21 19 D 5. 6. 7. 8. Tab. 1 Abb. 5 20 D 21 22 Vac/Hz Vdc A W Nm s °C PP7024 PP7024/V1 PP7224* 230/50 / ~1 120/50-60 / ~2 75 180 10 -20°÷50° IP 44 30% / 24 3 1 B ✄ D 23 1 2 4 7 5 6 3 2 1 24 Pop Índice: 1 pág. 2 2.1 2.2 2.3 2.4 26 3 27 26 26 26 26 27 4 4.1 28 28 5 5.1 28 28 27 27 27 6 28 7 28 29 27 27 27 27 27 27 25 E Actuador POP “PP7024” Actuador POP “PP7224” Fotocélula Antena 5. 6. 7. 8. Tab. 1 Fig. 5 26 E 27 28 Vac/Hz Vdc A W Nm s °C PP7024 PP7024/V1 PP7224* 230/50 / ~1 120/50-60 / ~2 75 180 10 -20°÷50° IP 44 30% / 24 3 1 B ✄ 29 E 1 2 4 7 5 6 3 2 1 30 pag. Opis produktu 2 2.1 2.2 2.3 2.4 2.5 2.6 2.7 Spis: pag. 32 3 33 32 32 32 32 33 33 33 33 4 4.1 34 34 5 5.1 34 34 6 34 7 34 35 33 33 33 33 33 33 PL • • • • • • • • 31 5. 6. 7. 8. Tab. 1 Rys. 5 32 PL 33 34 Vpp/Hz Vps A W Nm s °C PP7024 PP7024/V1 PP7224* 230/50 / ~1 120/50-60 / ~2 75 180 10 -20°÷50° IP 44 30% / 24 3 1 B ✄ Pop PL 35 1 2 4 7 5 6 3 2 1 36 Numero / Number: 172/997224 Data / Date: 02/2003 Il sottoscritto Lauro Buoro, Amministratore Delegato, dichiara che il prodotto The undersigned Lauro Buoro, General Manager of the following producer, declares that the product Nome produttore / Producer name: Indirizzo / Address: Tipo / Type: Modello / Model: Accessori / Accessories: Risulta conforme a quanto previsto dalle seguenti direttive comunitarie / Complies with the following community directives Riferimento n° Titolo Reference n° Title 98/37/CE (EX 89/392/CEE) DIRETTIVA MACCHINE / Machinery Directive 89/336/CEE DIRETTIVA COMPATIBILITA’ ELETTROMAGNETICA (EMC) / EMC Electromagnetic Compatibility Directive Risulta conforme a quanto previsto dalle seguenti Norme armonizzate / Complies with the following Harmonised standards Riferimento n° Edizione Titolo Livello di valutazione Reference n° Issue Title Estimate level EN55022 09/1998 Caratteristiche di radiodisturbo. Limiti e metodi di misura Information technology equipment - Radio disturbance characteristics. Limits and methods of measurement Classe Class B Inoltre dichiara che non è consentita la messa in servizio del prodotto suindicato finché la macchina, in cui il prodotto stesso è incorporato, non sia identificata e dichiarata conforme alla direttiva 98/37/CEE / He declares, moreover, that it is not allowed to use the above mentioned product until the machine, in which this product is incorporated, has been identified and declared in conformity with the regulation 98/37/CEE. P.S.:Il prodotto suindicato si intende parte integrante di una delle configurazioni di installazione tipiche, come riportato nei nostri cataloghi generali / The above mentioned product is meant integral part of the of one of the installation configuration as shown on our general catalogues. Amministratore delegato (General Manager) Lauro Buoro Nice France Buchelay Tel. +33.(0)1.30.33.95.95 Fax +33.(0)1.30.33.95.96 [email protected] Nice Belgium Leuven (Heverlee) Tel. +32.(0)16.38.69.00 Fax +32.(0)16.38.69.01 [email protected] Nice UK Chesterfield Tel. +44.87.07.55.30.10 Fax +44.87.07.55.30.11 [email protected] Nice Gate is the doors and gate automation division of Nice Nice Screen is the rolling shutters and awnings automation division of Nice Nice China Shanghai Tel. +86.21.575.701.46 Fax +86.21.575.701.44 [email protected] www.niceforyou.com P.S.: La dichiarazione di conformita’ del modello “PP7024” e’ presente nel fascicolo di istruzioni della centrale “POA1” Please find the declaration of conformity for model “PP7024” in the instruction booklet for the “POA1” control unit. POA1 Instructions and warnings for the fitter Istruzioni ed avvertenze per l’installatore Instructions et recommandations pour l’installateur Anweisungen und Hinweise für den Installateur Instrucciones y advertencias para el instalador Instrukcje i uwagi dla instalatora Aanwijzingen en aanbevelingen voor de installateur POA1 Table of contents: 1 2 2.1 2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 page page 3 Installation Typical system layout Preliminary checks Electrical connections Electrical diagram Description of the connections Notes about connections STOP type input Examples of photocell connections without the photo-test function 2.3.6 Examples of photocell connections with the phototest function. 2.3.7 Checking the connections 2.4 Automatic search system for the limit switches 3 3 4 4 4 5 5 6 6 3 Testing 9 4 9 5 Pre-set functions 9 7 8 8 6 6.1 6.2 6.3 6.4 Programmable functions Direct programming Level one programming, part one Level one programming, part two Level two functions 9 9 10 10 10 7 7.1 7.1.1 7.1.2 7.2 7.3 7.4 7.5 Programming Programming methods Level one programming: functions Level two programming: parameters Memory deletion Example of level one programming Example of level two programming Programming diagram 11 11 12 12 13 13 13 14 8 Optional accessories 15 9 9.1 Servicing the POA1 control unit Disposal 15 15 10 What to do if… 15 11 Technical characteristics 16 Annex Radio receiver 17 Warnings: ! This manual has been especially written for use by qualified fitters. The information provided in this manual is of no use to end users! This manual refers to the POA1 control unit and must not be used for any other products. 2 The POA1 control unit has been designed to control electromechanical actuators for automated swing gates or doors; any other use is considered improper and is consequently forbidden by the laws currently in force. Do not install the unit before you have read all the instructions at least once. 1) Product description: The POA1 control unit operates on the basis of a current sensitivity system which checks the load of the motors connected up to it. The system automatically detects travel stops, memorises the running time of each motor and recognises obstacles during normal movement (anti-crush safety feature). GB The control unit is pre-programmed for the normal functions, while more specific functions can be chosen following a simple procedure. The most important components of the POA1 control unit have been shown in Fig.1 in order to facilitate part identification. This feature makes installation easier as there is no need to adjust the working times nor the leaf delay. E F G H I L M A: 24V power supply connector 1 2 3 4 5 6 7 B: M1 motor connector 8 9 10 11 12 13 14 15 16 C: PS124 buffer battery connector L1...L5 D: 500mA F type services fuse E: Selector switch for delaying the opening of D motors M1 or M2 P1 F: M2 motor terminal G: Flashing light output terminal P2 H: Gate open indicator or electric lock output terminal C I: 24Vdc terminals for services and phototest P3 L: Input terminal B L1…L5: “Input” and “programming” LEDs N M: Terminal for radio aerial N: “SM” radio receiver connector 1 A O O: Programming/diagnostics connector P1, P2, P3: Programming buttons and leds ! The control unit is housed inside special casing in order to protect the electronic card from accidental damage. 2) Installation ! Automatic gate and door systems must only be installed by qualified fitters in the full compliance with the law. Be sure to note the warnings listed in the “Warnings for fitters” file. 2.1) Typical system layout 3 The typical system layout has been illustrated below in order to explain certain terms and aspects of an automatic 2-leaf swing door or gate system. 4 TO In particular, please note that: • Refer to the product instructions for the characteristics and connection of the photocells. • The “PHOTO” pair of photocells have no effect on the gate during opening, while they reverse movement during closing. • The “PHOTO1” pair of photocells stops both the opening and closing manoeuvres. • The “PHOTO2” pair of photocells (connected to the suitably programmed AUX input) have no effect during closing while they invert movement during opening. 2 1 5 PHOTO 2 7 PHO 6 1. PP7024 Electromechanical actuator (complete with incorporated control unit POA1) and 2. PP7224 Electromechanical actuator without control unit PHOTO 1 3. 4. 5. 6. 7. Flashing light Key switch “PHOTO” pair of photocells “PHOTO1” pair of photocells “PHOTO2” pair of photocells 3 2.2) Preliminary checks Before starting any kind of work, ensure that all the material is suitable for installation and complies with legal requirements. As well as checking all the points listed in the “Warnings for fitters” file, this section also contains a specific check list for the POA1 control unit. • Use shielded wire if the length is over 30m and only connect the earth braid on the control unit side. The cross-section of the connection cable for the motor must be at least 1.5mm2. • Do not connect cables in buried boxes even if they are completely watertight. • The “mechanical stops” must both be able to stop the gate from moving and easily absorb all the kinetic energy accumulated during movement (if necessary, use the stops for POP motors). • The power supply line must be protected by magneto-thermal and differential switches and equipped with a disconnection device. There must be over 3mm between the contacts. • Power the control unit using a 3 x 1.5mm2 cable. Install an earth plate near the control unit if the distance between the control unit and the earth connection is over 30m. • Use wires with a minimum cross section of 0.25mm2 to connect extra-low voltage safety circuits. 2.3) Electrical connections ! Unplug the unit from all sources of electricity in order to ensure the fitter is protected and to prevent components being damaged during electrical or radio receiver connection. • With the exception of the photocell inputs when the PHOTOTEST function is activated, if the inputs of the NC (Normally Closed) contacts are not in use they should be jumped with the “COMMON” terminal. Refer to paragraph 2.3.6 for further information. • If there is more than one NC contact on the same input, they must be connected in SERIES. • If the inputs of the NO (Normally Open) contacts are not used they should be left free. • If there is more than one NO contact on the same input, they must be connected in PARALLEL. • The contacts must be mechanical and potential-free. Stage connections, such as those defined as "PNP", "NPN", "Open Collector", etc. are not allowed. • If the leafs overlap, use jumper E (Figure 1) to select which motor starts up first during opening. M1 has an incorporated control unit, M2 does not. M1 Jumper “E” M2 AERIAL AUX (NO) PHOTO1 (NC) PHOTO (NC) COMMON STOP (NC) 0V 24Vd.c. - + + Jumper “E” +24Vd.c. PHOTOTEST M2 SCA/Electric lock Flashing lamp 24vd.c. M1 - M2 N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3 4 2.3.2) Description of connections GB Here follows a brief description of the possible control unit output connections: Terminals L-N1÷3 4÷5 6÷7 Function Power supply line Motor 2 Flashing light Open Gate indicator/Elect.Lock Description mains power supply * M2 motor connection Connection of flashing light 24Vd.c. max. 25W Connection for Open Gate Indicator 24Vac max. 5W or Electric lock 12V max. 25VA please refer to the “Programming” chapter) 8 24Vdc/Phototest Power Supply +24V TX photocells for phototest (max. 100mA) 9 0Vdc 0V Power supply for services 10 24Vdc Power input for services, RX photocells, etc. (24Vac max. 200mA) 11 Common Common for all inputs (+24Vdc) 12 STOP **Input with STOP function (emergency, safety shutdown) 13 PHOTO NC Input for safety devices (photocells, sensitive edges) 14 PHOTO1 Input NC for safety devices (photocells, sensitive edges) 15 STEP-BY-STEP Input for cyclical functioning (OPEN-STOP-CLOSE-STOP) 16 AUX *** Auxiliary input 17÷18 Aerial Connection for the radio receiver aerial * This is not used for single leaf gates (the control unit automatically recognises if only one motor has been installed). ** The STOP input can be used for “NC” or constant resistance 8,2kΩ contacts (please refer to the “Programming” chapter) *** The auxiliary input AUX may be programmed in one of the following functions: Function Input type Description PARTIAL OPEN TYPE 1 NO Fully opens the upper leaf PARTIAL OPEN TYPE 2 NO Opens the two leaf half way OPEN NO Only carries out the opening manoeuvre CLOSE NO Only carries out the closing manoeuvre PHOTO 2 NC PHOTO 2 function DISABLED -No function Unless otherwise programmed, the AUX input performs the Partial Open TYPE 1 function 2.3.3) Notes about connections Most connections are extremely simple and many of them are direct connections to a single user point or contact. NC NO STOP C C NO NC NC NO 15 15 11 11 11 11 12 AUX C C NO NC The following figures show examples of how to connect external devices. Key switch connection Example 1 How to connect the switch in order to perform the STEP-BY-STEP and STOP functions. Example 2 How to connect the switch in order to perform the STEP-BY-STEP function and one of the auxiliary input functions (PARTIAL OPENING, OPEN ONLY, CLOSE ONLY …). 16 24Vdc max 5W 7 12Vac max 25VA 6 Connection for Gate Open Indicator/Electric lock If the gate open indicator has been programmed, the output can be used as an open gate indicator light. It flashes slowly during opening, and quickly during closing. If it is on but does not flash, this indicates that the gate is open. If the light is off, the gate is closed. If the electric lock has been programmed, the output can be used as an electric lock. The electric lock will activate for 3 seconds each time opening begins. 7 5 2.3.4) STOP type input The POA1 control unit can be programmed for two types of STOP input: - NC type STOP for connecting up to NC type contacts - Constant resistance STOP: it enables the user to connect up to the control unit of devices with 8.2kΩ constant resistance (e.g. sensitive edges). The input measures the value of the resistance and disables the manoeuvre when the resistance is outside the nominal value. Devices with normally open “NO” or normally closed “NC” contacts, or multiple devices, even of different types, can be connected to the constant resistance STOP input, provided that appropriate adjustments are made. For this purpose, refer to the following the table: Note 1. Any number of NO devices can be connected to each other in parallel, with an 8.2KΩ termination resistance (Figure 4). Note 2. The NO and NC combination can be obtained by placing the two contacts in parallel, and placing an 8.2KΩ resistance in series with the NC contact. It is, therefore, possible to combine 3 devices: NO, NC and 8.2KΩ).(Figure 5) Note 3. Any number of NC devices can be connected in series to each other and to an 8.2KΩ resistance (Figure 6). Note 4. Only one device with an 8.2KΩ constant resistance output can be connected; multiple devices must be connected “in cascade” with a single 8.2KΩ termination resistance (Figure 7) ! If the constant resistance STOP input is used to conTable 1 nect devices with safety functions, only the devices with 8.2KΩ constant will resistance output guarantee the failsafe category 3. o 2nd device type: 1st device type: NO NC 8,2KΩ NO (note 2) NC (note 1) In series (note 3) In series In series (note 4) 8,2KΩ NC 11 11 NO NA 11 NO NA NA NO NC 8,2KΩ 8,2KΩ 12 12 4 8,2KΩ 12 5 6 1 11 12 NC n 2 Sensitive edge Sensitive edge 8,2KΩ Sensitive edge 7 2.3.5) Examples of photocell connections without the phototest function. Connecting the PHOTO photocell only. TX 11 PHOTO and PHOTO1 connections RX TX RX 14 1 2 10 9 PHOTO FOTO 10 9 11 13 PHOTO FOTO 1 2 3 4 5 1 2 1 2 3 4 5 10 9 11 13 10 9 TX 1 2 RX PHOTO FOTO 1 1 10 9 10 9 6 11 14 1 2 3 4 5 PHOTO, PHOTO1 and PHOTO2 connections (The auxiliary input AUX must be programmed as PHOTO2) TX RX GB PHOTO FOTO 1 2 1 2 3 4 5 10 9 11 13 10 9 RX TX PHOTO FOTO 1 1 1 2 1 2 3 4 5 10 9 11 14 10 9 TX RX PHOTO FOTO 2 2 1 2 1 2 3 4 5 10 9 11 16 10 9 2.3.6) Examples of photocell connections with the phototest function. PHOTO and PHOTO1 connections RX TX The programmable PHOTO-TEST function is a feature on the POA1 control unit (this function is not activated initially). This is an excellent solution as regards the reliability of safety devices and places the control unit and safety devices in “Category 2” of UNI EN 954-1 standard (ed. 12/1998). The safety devices are checked whenever a manoeuvre is started, and will only begin if everything is in order. This is only possible using a special configuration of the safety device connections. The “TX” photocell transmitters are basically powered separately from the “RX” receivers. PHOTO FOTO 1 2 10 9 11 13 8 9 TX connected to terminal n°8. Please consult the following figures for examples RX PHOTO FOTO 1 1 1 2 1 2 3 4 5 10 9 When the phototest is activated, the FOTO, FOTO1 and FOTO2 inputs will be subjected to testing. If one of these inputs is not being used, it must be 1 2 3 4 5 11 14 8 9 of connections. PHOTO, PHOTO1 and PHOTO2 connections (The auxiliary input AUX must be programmed like PHOTO2) Connecting the PHOTO photocell only. TX 8 RX TX 14 1 2 8 9 PHOTO FOTO 10 9 11 13 1 2 3 4 5 RX PHOTO FOTO 1 2 1 2 3 4 5 10 9 11 13 8 9 TX RX PHOTO FOTO 1 1 1 2 1 2 3 4 5 10 9 11 14 8 9 TX 1 2 RX PHOTO FOTO 2 2 1 2 3 4 5 10 9 8 9 11 16 7 2.3.7) Checking the connections ! WARNING: The next operations involve work being carried out on live circuits. Some parts have mains voltage running through them and are therefore EXTREMELY DANGEROUS! Pay maximum attention to what you are doing and NEVER WORK ALONE! The system can be checked once the connections for the automation have been made. 1. Power the control unit and check that all the LEDs flash rapidly for a few seconds. 2. Check that there is a voltage of approximately 32Vdc on terminals 9-10. If not, unplug the unit immediately and carefully check the connections and input voltage. 3. After initially flashing rapidly, the P1 LED will indicate the control unit is working correctly by flashing regularly at 1 second intervals. When there is a variation in the inputs, the “P1” led will rapidly flash twice to show that the input has been recognised. 4. If the connections are correct, the LED for the “NC”-type inputs will be on, while those for the “NO” type inputs must be off. Here follows Figure 8 illustrating the LEDs on, and the summary table of the various possible situations: 5. Check that the relative LEDs switch on and off when the devices connected to the inputs are operated. 6. Check that by pressing P2 both motors perform a short opening manoeuvre, and the motor of the upper leaf starts first. Block the manoeuvre by pressing P2 again. If the motors do not start up for opening, invert the polarities of the motor cables. If, however, the first one to move is not the upper leaf, operate jumper E (see figure). M1 Jumper “E” M2 INPUT STOP PHOTO PHOTO 1 STEP-BY-STEP AUX INPUT TYPE STOP NC CONSTANT RESISTANCE STOP 8,2KΩ OPEN PARTIALLY type 1 OPEN PARTIALLY type 2 OPEN ONLY CLOSE ONLY PHOTO2 8 2.4) Automatic search system for the limit switches On the successful completion of the various controls, start the automatic search system phase for the limit switches. This work is necessary as the POA1 control unit must “measure” how long the opening and closing manoeuvres take. This procedure is completely automatic and detects the mechanical opening and closing stops by measuring the load on the motors. If this procedure has already been carried out, in order to reactivate it, the user must first delete the memory (see the “Memory deletion” chapter). In order to check whether the memory contains any limit switch parameters, turn the power supply to the control unit on and then off again. If all the LEDs flash rapidly for approximately 6 seconds, the memory is empty. If, however, they only flash for 3 seconds, the memory already contains some limit switch parameters. • Before starting limit switch searching, make sure that all the safety devices are enabled (STOP, PHOTO and PHOTO1). The procedure will be immediately interrupted if a safety device triggers or a command arrives. • Ideally the doors should be half open, although they can be in any position. • Press the P2 button to begin searching, which runs as follows: - Both motors open briefly - Motor closes the lower leaf until it reaches the mechanical closing stop. - The upper leaf motor closes until it reaches the mechanical closing stop. - The motor of the upper leaf begins to open. - After the programmed delay, opening of the lower leaf begins. If the delay is insufficient, block the search by pressing P1, then modify the time (see the “Programming” chapter). - The control unit measures the movement required for the motors to reach the opening mechanical stops. - Complete closing manoeuvre. The motors can start at different times, the aim is to prevent the leafs from shearing by maintaining a suitable delay. - End of the procedure with memorisation of all measurements. All these phases must take place one after the other without any interference from the operator. If the procedure does not continue correctly, it must be interrupted with the P1 button. Repeat the procedure, modifying some parameters if necessary, for example the current sensitivity cut-in thresholds (see the “Programming” chapter). 9 8 3) Testing ! The automation system must be tested by qualified and expert staff who must establish which tests to perform depending on the relative risk. Testing is the most important part of the whole installation phase. Each single component, e.g. motors, radio receiver, emergency stop, photocells and other safety devices, may require a specific test phase; please follow the procedures shown in the respective instructions manuals. Carry out the following procedure in order to test the POA1 control unit, (the sequence refers to the POA1 control unit with pre-set functions). • Make sure that the activation of the STEP-BY-STEP input generates the following sequence of movements: Open, Stop, Close, Stop. • Make sure that the activation of the AUX input (Type 1 partial opening function) manages the Open, Stop, Close, Stop sequence of the motor of the upper leaf only, while the motor of the lower leaf remains in the closed position. • Perform an opening manoeuvre and check that: - the gate continues the opening manoeuvre when PHOTO is engaged. - the opening manoeuvre stops when PHOTO1 is engaged and only continues when PHOTO1 is disengaged. - The manoeuvre stops when PHOTO2 (if installed) is engaged and the closing manoeuvre starts. GB • Make sure that the motor switches off when the door reaches the mechanical stop. • Perform a closing manoeuvre and check that: - The manoeuvre stops when PHOTO is engaged and the opening manoeuvre starts. - The manoeuvre stops when PHOTO1 is engaged and the opening manoeuvre starts when PHOTO1 is disengaged. - The gate continues the closing manoeuvre when PHOTO2 is engaged. • Check that the stopping devices connected to the STOP input immediately stop all movement. • Check that the level of the obstacle detection system is suitable for the application. - During both the opening and the closing manoeuvres, prevent the leaf from moving by placing an obstacle and check that the manoeuvre inverts before exceeding the force set down by law. • Other checks may be required depending on which devices are connected to the inputs. If an obstacle is detected as moving in the same direction for 2 consecutive manoeuvres in the same direction, the control unit partially inverts both motors for just 1 second. At the following command, the leafs begin the opening manoeuvre and the first current sensitivity cut-in for each motor is considered as a stop during the opening cycle. The same happens when the mains power supply is switched on: the first command is always an opening manoeuvre and the first obstacle is always considered as an open limit switch. 4) Diagnostics The diagnostics LED P2 indicates any problems or malfunctions revealed by the control unit during the manoeuvre. A sequence with a certain number of flashes indicates the type of problem and remains active until the following manoeuvre begins. The table below summarises this information: Number Type of malfunction Flashing P2 LED 1 M1 current sensitivity device triggering 2 M2 current sensitivity device triggering 3 STOP input cut-in during the manoeuvre. 4 Phototest error 5 Output overcurrent gate open indicator or electric lock 5) Pre-set functions The POA1 control unit features some programmable functions. After the search phase these are pre-set in a typical configuration which satisfies most automatic systems. These functions can be changed at any time, both before and after searching, by carrying out the relevant programming procedure (refer to the “Programmable functions” chapter). • • • • Motor movement: Automatic closing Condominium function Pre-flashing : : : : fast active deactivated deactivated • • • • • • • • • Close after photo Opening delay Phototest Gate open indicator/Electric Lock STOP input Heavy gates Proportional gate open indicator Pause time Auxiliary input the upper leaf motor is activated) • Current sensitivity : : : : : : : : : deactivated level 2 (10%) deactivated Gate open indicator NC type deactivated deactivated 20 seconds type 1 partial opening (only : Level 2 6) Programmable functions To ensure the system is best suited to the user’s requirements, and safe in the various different conditions of use, the POA1 control unit offers the possibility to programme several functions or parameters, as well as the function of a number of inputs and outputs. 6.1) Direct programming • Slow/rapid movement The user can choose the speed of movement of the gate, at any time (with the motor arrested) simply by operating the P3 key at any time the control unit is not being programmed. If LED L3 is off, this shows that the slow movement has been set, if on the fast one has. 9 6.2) Level one programming, part one • Automatic closing: This function features an automatic closing cycle after the programmed pause time; the pause time is factory set to 20 seconds but it can be modified to 5, 10, 20, 40 or 80 seconds. If the function is not activated, the system will run “semi-automatically”. • “Condominium” function: This function is useful when the automatic system is radio-commanded by many different people. If this function is active, each command received triggers an opening manoeuvre that cannot be interrupted by further commands. If the function has been deactivated, a command causes: OPEN-STOP-CLOSE-STOP • Pre-flashing: This function activates the flashing light before the manoeuvre begins for a time that can be programmed to 2, 4, 6, 8 or 10 seconds. If the function is deactivated, the light will start flashing when the manoeuvre starts. • Close after photo: During the automatic closing cycle, this function reduces the pause time to 4 seconds after the PHOTO photocell has disengaged, i.e. the gate closes 4 seconds after the user has passed through it. If the function is deactivated, the whole programmed pause time will pass. • Opening delay During opening, this function causes a delay in the activation of the lower leaf motor compared with the upper one This is necessary in order to prevent the leafs from getting stuck. There is always a standard delay during closing, calculated automatically by the control unit in order to ensure the same delay as the one programmed for opening. 6.3) Level one programming, part two • Phototest function The POA1 control unit can also activate the phototest procedure. The correct functioning of the photocells is checked every time a manoeuvre starts. In order to be able to use this function, the photocells must be correctly connected up (refer to paragraph 2.3.6) and the function then activated. If the function is deactivated, the control unit will not carry out the photo-test. • Open gate indicator light / electric lock If the function is activated, terminals 6-7 can be used to connect up the electric lock. If the function is deactivated, terminals 6-7 can be used to connect up a 24V gate open indicator. • NC Type or Constant Resistance STOP Input If the function is activated, the STOP input is set to “8.2KΩ Constant Resistance”. In this case, there must be a 8.2KΩ +/-25% resistance between the common and the input to enable the operation. If the function is not set, the configuration of the STOP input will enable it to function with NC type contacts. • Light/heavy gates If the function is activated, the control unit enables the user to manage heavy gates, setting the acceleration ramps and slowdown speeds during closing differently. If the function is deactivated, the control unit will be set to manage light gates. • Proportional Open Gate Indicator If the function is activated, the gate open indicator output will be set with the proportional flashing light. This means that during opening, the flashing becomes more intense as the leafs come nearer to the opening stops; vice-versa, for closing, the flashing becomes less intense as the leafs come nearer to the closing stops. If the function is deactivated, the light will flash slowly during opening and rapidly during closing. 6.4) Level two functions • Pause time The pause time, namely the time which lapses between opening and closing during automatic functioning, can be programmed to 5, 10, 20, 40, and 80 seconds. • Auxiliary Input AUX The control unit offers an auxiliary input which can be set to carry out one of the following 6 functions: - Partial opening type 1: this carries out the same function as the STEP-BY-STEP input. It causes only the upper leaf to open. It only works if the gate is closed completely, otherwise the command is interpreted as if it were a STEP-BY-STEP command. 10 - Partial opening type 2: this carries out the same function as the STEP-BY-STEP input. It causes the two leafs to open for half the time it would take them to open completely. It only functions if the gate is closed completely, otherwise the command is interpreted as if it were a STEP-BY-STEP command. - Open only: this input only causes opening in the Open- StopOpen-Stop sequence. - Close only: this input only causes closing in the Close-StopClose-Stop sequence. - Photo 2: this carries out the function of the “PHOTO 2” safety device. - Disabled: the input will not carry out any function. • Pre-flashing time: A manoeuvre warning sign can be activated on the flashing light before each manoeuvre begins, and the time programmed to 1, 2, 4, 6, 8 and 10 seconds. • Current sensitivity: The control unit is equipped with a system which measures the current absorbed by the two motors used to detect the mechanical stops and any obstacles when the gate is moving. Since the current absorbed depends on a number of conditions, including the weight of the gate, friction, wind and variations in voltage, the cut-in threshold can be changed. There are 6 levels: 1 is the most sensitive (minimum force), 6 is the least sensitive (maximum force). ! If the “current sensitivity” function (together with oth- GB er vital features) is adjusted correctly, the system will comply with European standards, EN 12453 and EN 12445, which require techniques or devices to be used to limit force and danger during the functioning of automatic gates and doors are moved. • Leaf delay: The delay in starting up the motor of the lower leaf can be programmed to 5, 10, 20, 30 or 40% of the working time. 7) Programming All the functions described in the “Programmable functions” chapter can be selected by means of a programming phase which terminates by memorising the choices made. The control unit therefore has a memory which stores the functions and parameters relative to the automation process. 7.1) Programming methods The P1, P2 and P3 buttons are used for all the programming phases, while the 5 Leds (L1, L2…L5) indicate the selected “parameter”. There are two different programming levels: • At level 1, the functions can be activated or deactivated. Each Led (L1, L2…L5) corresponds to a function: if the Led is on, the function is active; if it is off, it is deactivated. Level one consists in 2 parts which can be selected using the P3 button. The corresponding LED P3 indicates which of the 2 parts has been selected. Level one (fixed LED P1): part one - (LED P3 off) Level one (fixed LED P1): part two - (LED P3 on) Led L1 Led L2 Automatic closing “Condominium” Pre-flashing function Led L3 Led L4 Led L5 Led L1 Led L2 Led L3 Close after photo Opening delay Phototest Electric Lock Resistive STOP Heavy gates Led L4 Led L5 Proportional Open Gate • It is possible to pass to the second level from level one of part one. At this second level the user can choose the parameter relating to the function. A different value corresponds to each LED which must be associated to the parameter. Level one (fixed LED P1): part one - (LED P3 off) Level one (fixed LED P1): part two - (LED P3 on) Led L1 Led L2 Automatic closing “Condominium” Pre-flashing function Led L3 Led L4 Led L5 Led L1 Led L2 Led L3 Close after photo Opening delay Phototest Electric Lock Resistive STOP Heavy gates Led L4 Led L5 Proportional Open Gate Second level: Parameter: Parameter: Parameter: Parameter: Parameter: Pause Time AUX Input Pre-flashing Time Current sensitivity Leaf Delay L1: 5s L1: Open partially type 1 L1: 2s L2: 10s L2: Open partially type 2 L2: 4s L2: 10% L3: 20s L3: Open only L3: 6s L3: 20% L4: 40s L4: Close only L4: 8s L4: 30% L5: 80s L5: Photo 2 L5: 10s All LEDs off: input not used All LEDs off: level 6 (max. current sensitivity) 11 7.1.1) Level one programming: functions At level one, the functions can be activated or deactivated. At level one, LED P1 is always on; if LEDs L1, L2…L5 are on, the functions are activated; if the LEDs are off, the functions are deactivated. A flashing LED indicates which function has been selected; Table “A1” 1. Table “A2” 1. short flashes indicate the function has been deactivated; long flashes indicate the function has been activated. Press P3 to pass from part one programming to part two programming, and vice-versa. Entering level one programming: Press and hold down buttons P1 and P2 for at least 3 seconds The programming mode has been entered if all the Leds start flashing quickly Example Activating or deactivating a function: Press P1 repeatedly until the flashing Led reaches the function required. Example P1 P2 3s P1 2. Press P2 to activate or deactivate the function. P2 Table “A3” 1. To pass from part one to part two of level one (and vice-versa): Press P3. button Table “A4” 1. To exit level one and save the modifications: Press and hold down buttons P1 and P2 for at least 3 seconds Table “A5” 1. Exiting level one and delete the modifications: Either press P1 for at least 3 seconds, or wait for 1 minute, or disconnect the power supply P2 3s Example P1 or 3s 60s, or 7.1.2) Level two programming: parameters The function parameter can be chosen at level two. Level two can only be reached from level one. Table “B1” 1. At level 2 the P1 Led flashes quickly while the 5 Leds (L1, L2…L5) indicate the selected parameter. Entering level two programming: Enter level one programming by pressing P1 and P2 for at least 3 seconds 2. P2 3s Select the function by pressing P1 until the flashing Led reaches the point required. P1 3. Enter level two by pressing the P2 button for at least 3 seconds P2 Table “B2” 1. Selecting the parameter: Press P2 repeatedly until the Led reaches the desired parameter 3s Table “B3” 1. Returning to level one: Press P1 Table “B4” 1. Exiting level one and saving modifications: Press and hold down buttons P1 and P2 for at least 3 seconds Table “B5” 1. Exiting level one and cancelling modifications: Either press P1 for at least 3 seconds, or wait for 1 minute, or disconnect the power supply 3s P1 or or 12 P2 60s, 7.2) Memory deletion Each new programme replaces the previous settings. It is usually unnecessary to “delete all” the memory. If required, the memory can be totally deleted by performing this simple operation: Table “C1” 1. 2. GB ! As all the functions return to their pre-set values after the memory is deleted, a new search for the mechanical stops must be carried out. Delete memory: Switch the power supply to the control box off, and wait until all the LEDs have gone off (remove fuse F1 if necessary). Press P1 and P2 on the board down and keep them pressed down. 3. Switch the power supply on again. 4. Wait at least 3 seconds before releasing the two keys Example P1 P2 P1 P2 3s If the memory was deleted correctly, all the Leds will switch off for 1 second. 7.3) Example of level one programming The following examples show how to activate or deactivate a level one function, the “Condominium” function, for example, and prepare the “Gate Open Indicator” output in order to activate the electric lock. 1. 2. Example of level one programming: activate the “Condominium” function and “Electric lock” output Access the level one programming mode by pressing P1 and P2, and keeping them pressed down for at least 3 seconds. Press P1 once to move the flashing Led to the Led 2 (the flashes will be short) P1 3s P2 3s 2 P1 x1 3. P2 Activate the “Condominium” function by pressing P2 (the flashes will be longer). P2 4. Press P3 once in order to activate part two (the P3 LED will switch on) P3 5. Press P1 once to move the flashing Led to the Led 2 (the flashes will be short) 2 P1 6. Activate the “Electric lock” output by pressing P2 (the flashes will be longer). P2 7. Press P1 and P2 for at least 3 seconds to exit the programming mode and save modifications P1 7.4) Example of level two programming This example shows how to modify a level two parameter, for example, how to modify current sensitivity intil “level 5”. 1. Example of level two programming: modifying “current sensitivity” Access the level one programming mode by pressing P1 and P2 for at least 3 seconds 2. P2 4 P1 x3 3. 3s Press P1 three times to move the flashing Led to the Led 4 Access level two by pressing P2 for at least 3 seconds. P2 4. 3s Press P2 three times until Led 5 switches on 5 P2 x3 5. Return to level one by pressing P1. P1 6. Press P1 and P2 for at least 3 seconds to exit the programming mode and save modifications P1 P2 3s 13 7.5) Programming diagram The following figure shows the complete programming diagram of the functions and relative parameters. This figure also shows the functions and parameters either as they were initially or following total memory deletion. Normal operation P1 Led P1 Slow flashing ALT Photo Photo 1 Step by step AUX P2 P3 P1+P2 for 3 secs P1 for 3 secs (NO SAVE) P1+P2 for 3 secs (SAVE) - P1 first! P1 Level one Led P1 On permanently Autom. Cond. PreClose closing flashing after Photo Opening delay P2 P1 On Off P3 Photo- Electric Resist. Heavy Proportional Gate test Lock STOP. gates Open P3 P2 On Off P3 PAUSE TIME P2 for 3 secs P1 P1 5 10 20 40 80 P2 seconds P3 AUXILIARY INPUT (*) P1 Level two Led P1 Rapid flashing type 1 type 2 only only Photo 2 p.o p.o opening closing P2 P3 PRE-FLASHING TIME P1 2 4 6 8 10 P2 seconds P3 CURRENT SENSITIVITY P1 1 2 3 4 5 P2 Level P3 (*) a.p. type 1 All Leds off ➡ max. current sensitivity OPENING DELAY a.p. type 2 type 2 partial opening, both motors move for 1/2 the working time set [N.O.] P2 Only open P3 Only closed close➔stop➔close➔stop… [N.O.] Photo 2 used as photo 2 [n.c.] P1 5 10 20 30 40 type 1 partial open, upper leaf moves [N.O.] % 14 8) Optional accessories • “RADIO” Card The control unit has a connector for fitting a 4 channel radio card complete with SM slot. This remote control device functions by means of transmitters which act on the inputs as per the following table: Output Receiver N° 1 N° 2 N° 3 N° 4 GB • PS124 Buffer Battery PS124 buffer batteries can be used to supply the control unit in case of network blackouts. Control unit input STEP-BY-STEP AUX (reset value: Partially Open 1) “Open only” “Only close” 9) POA1 control unit maintenance As the POA1 control unit is electronic it requires no particular maintenance. However, at least every six months the efficiency of the entire system must be checked according to the information described in the “Testing” chapter. 9.1) Disposal This product is made from various kinds of material, some of which can be recycled. Make sure you recycle or dispose of the product in compliance with laws and regulations locally in force. ! Some electric components may contain polluting substances; do not dump them. 10) What to do if… This section will help fitters to solve some of the most common problems that may arise during installation. No LEDs are on: • Check whether the control unit is powered (measure a voltage of about 32Vdc at terminals 9-10). • Check the 2 fuses, if not even the P1 Led is on or flashing a serious fault has probably occurred and the control unit must therefore be replaced. The P1 LED flashes regularly but the INPUT LED’s do not reflect the state of the respective inputs. • Switch the unit off for the moment in order to exit a possible programming phase. • Carefully check the connections on terminals 11 to 16. The “Automatic search” procedure does not start up. • The “Automatic search” procedure only starts if it has never been performed before or if the memory has been deleted. To check whether the memory is empty switch off the unit for a moment. When it is switched on again, all the Leds should flash rapidly for about 6 seconds. If they only flash for 3 seconds, the memory already contains valid values. If a new “Automatic search” is required, the memory must be completely deleted. The “Automatic search” procedure has never been performed but it either does not start or it behaves incorrectly • The system and all the safety devices must be operative in order to activate the “Automatic search” procedure. • Make sure that no device connected to the inputs cuts in during the “Automatic search” procedure. • In order for the “Automatic search” procedure to start correctly, the input Leds must be on as shown, the P1 Led must flash once a second. The “Automatic search” procedure was performed correctly but the manoeuvre does not start • Check that the safety device (STOP, PHOTO, PHOTO1 and, if installed, PHOTO2) Leds are on and that the relative command Led (STEP-BY-STEP or AUX) remains on for the entire duration of the command. • If the “phototest” function is activated but the photocells do not function correctly, the DIAGNOSTICS LED indicates the fault by flashing four times. The gate inverts the direction while moving An inversion is caused by: • The photocells triggering (PHOTO2 during the opening manoeuvre, PHOTO or PHOTO1 during the closing manoeuvre). In this case, check the photocell connections and input LEDs. • The current sensitivity device triggers while the motors are moving (not near the mechanical stops, therefore). This is considered as an obstacle and causes an inversion. To find out if the current sensitivity device has triggered, count how many times the DIAGNOSTICS LED flashes: 1 flash indicates that the current sensitivity device triggered on account of motor M1, 2 flashes indicate that this was caused by motor M2. 15 11) Technical specifications Power input Max. absorbed power Emergency Electricity supply Maximum motor current Service power output Phototest output Flashing lamp output Gate open indicator output STOP Input Working time Pause time Pre-flashing time Leaf delay in open cycle Leaf delay in close cycle 2nd motor output Maximum cable lengths Operating temperature 16 : POA1 Control unit ➔ 230Vac ±10% 50÷60Hz : POA1/V1 Control unit ➔ 120Vac ±10% 50÷60Hz : 170 VA : for PS124 buffer batteries : 3A with a “level 6” current sensitivity cut in) : 24Vdc 200mA maximum current (the voltage can range from 16 to 33Vdc) : maximum current 24Vdc 100mA (the voltage can range from 16 to 33Vdc) : for flashing lamp 24Vdc, maximum power 25W (the voltage can range from 16 to 33Vdc) : for indicator lamps at 24Vdc maximum power 5W (the voltage can range from 16 to 33Vdc) or electric locks 12Vac 25W : for NC contacts or constant resistance 8,2KΩ +/- 25% : automatic detection : programmable at 5, 10, 20, 40, 80 seconds : programmable at 2, 4, 6, 8, 10 seconds : programmable at 5, 10, 20, 30 and 40 % of working time : Automatic detection : for POP PP7224 motors : electricity supply 30m : 2nd motor 15m : other inputs/outputs 50m : aerial 10m : -20÷50°C smxi smif smxis radio receiver GB Description of the product SMXI, SMXIS and SMXIF are 4-channel radio receivers for control units equipped with SM-type connector. The peculiarity of compatible transmitters is that the identification code is different for each transmitter. Therefore, in order to allow the receiver to recognise a determined transmitter, the recognition code must be memorised. This operation must repeated for each transmitter required to communicate with the control unit. Up to a maximum of 256 transmitters can be memorised in the receiver. No one transmitter can be cancelled; all the codes must be deleted. - For more advanced functions use the appropriate programming unit. Mode I. Each transmitter button activates the corresponding output in the receiver, that is, button 1 activates output 1, button 2 activates output 2, and so on. In this case there is a single memorisation phase for each transmitter; during this phase, it doesn’t matter which button is pressed and just one memory sector is occupied. Mode II. Each transmitter button can be associated with a particular output in the receiver, e.g., button 1 activates output 2, button 2 activates output 1, and so on. In this case, the transmitter must be memorised, pressing the required button, for each output to activate. Naturally, each button can activate just one output while the same output can be activated by more than one button. One memory section is occupied for each button. The receiver features 4 outputs, all available on the underlying connector. To find out which function is performed by each output, see the control unit’s instructions. During the transmitter code memorisation phase, one of these options may be chosen: Installing the aerial The receiver requires an ABF or ABFKIT type aerial to work properly; without an aerial the range is limited to just a few metres. The aerial must be installed as high as possible; if there are metal or reinforced concrete structures nearby you can install the aerial on top. If the cable supplied with the aerial is too short, use a coaxial cable with 50-Ohm impedance (e.g. low dispersion RG58), the cable must be no longer than 10 m. If the aerial is installed in a place that is not connected to earth (masonry structures), the braid’s terminal can be earthed to provide a larger range of action. The earth point must, of course, be local and of good quality. If an ABF or ABFKIT aerial cannot be installed, you can get quite good results using the length of wire supplied with the receiver as the aerial, laying it flat. 17 Memorising a remote control ! When the memorisation phase is activated, any transmitter correctly recognised within the reception range of the radio is memorised. Consider this aspect with care and remove the aerial if necessary to reduce the capacity of the receiver. The procedures for memorising the remote controls must be performed within a certain time limit; please read and understand the whole procedure before starting. In order to carry out the following procedure, it is necessary to use the button located on the box of the radio receiver (reference A, Fig. 1b), and the corresponding LED (reference B, Fig. 1b) to the left of the button. 1b Table “B1” Mode I memorising (All buttons are memorised on the related receiver output) 1. Press and hold down the receiver button for at least 3 seconds 2. Release the button when the Led lights up Example RX 3s RX 3. Push, for at least 2 seconds, any of the buttons of the transmitter to be memorised within 10 seconds N.B.: If the procedure was memorised correctly, the Led on the receiver will flash 3 times. If there are other transmitters to memorise, repeat step 3 within another 10 seconds The memorisation phase finishes if no new codes are received for 10 seconds. Table “B2” 2s TX x3 Mode II memorising (A specific receiver output can be associated to each button) 1. Press and release the receiver button as many times as the number of the desired output (Once for output No. 1, twice for output No. 2) Check that the LED emits the same number of flashes as the desired output, repeated 2. over 10 seconds in regular intervals (1 flash if output No. 1, 2 flashes if output No. 2) 3. Within 10 seconds press the desired button on the transmitter to be memorised, holding it down for at least 2 seconds. N.B.: If the procedure was memorised correctly, the Led on the receiver will flash 3 times. If there are other transmitters to memorise, repeat step 3 within another 10 seconds The memorisation phase finishes if no new codes are received for 10 seconds. RX 2s TX x3 Remote memorising It is possible to enter a new transmitter in the receiver memory without using the keypad. A previously memorised and operational remote control must be available. The new transmitter will “inherit” the characteristics of the previously memorised one. Therefore, if the first transmitter is memorised in mode I, the new one will also be memorised in mode I and any of the buttons of the transmitter can be pressed. If the first transmitter is memorised in mode II the new one will also be memorised in mode II but the button activating the required output must be pressed on the first transmitter as must the button required to be memorised on the second. You need to read all the instructions in advance so you can perform the operations in sequence without interruptions. Now, with the two remote controls (the NEW one requiring code memorisation and the OLD one that is already memorised), position yourself within the operating range of the radio controls (within maximum range) and carry out the instructions listed in the table. Table “B3” Remote Memorising 1. Press the button on the NEW transmitter for at least 5 seconds and then release 2. Press the button on the OLD transmitter 3 times slowly 3. Press the button on the NEW transmitter slowly and then release TX TX 1s TX TX N.B.: If there are other transmitters to memorise, repeat the above steps for each new transmitter 18 1s TX TX 1s x1 Deleting all transmitters GB All the memorised codes can be deleted as follows: Table “B4” Deleting all transmitters Example 1. Press the receiver button and hold it down RX 2. 3. Wait for the Led to light up, then wait for it to switch off and then wait for it to flash 3 times Release the button exactly during the third flash x3 RX N.B.: if the procedure was performed correctly, the Led will flash 5 times after a few moments. 3° x5 Technical characteristics Receivers SMXI Rolling code 52 bit FLOR FLOR, VERY VR Decoding Transmitter compatibility Frequency Input impedance Outputs Sensitivity Working temp. SMXIS Rolling code 64 bit SMILO SMILO 433.92MHz 52ohm 4 (on connector SMXI) better than 0.5µV -10°C ÷ + 55°CC SMXIF 1024 FLO combinations FLO, VERY VE Transmitters Buttons Power input Absorption Frequency Working temp. Radiated power FLOR 1–2-4 12Vdc Batt. 23A 10mA VERY VR 2 6Vdc lithium batt. 10mA FLO 1–2-4 12Vdc Batt. 23° 15mA 433.92MHz -40°C ÷ + 85°C 100µW VERY VE 2 6Vdc lithium batt. 10mA SMILO 2-4 12Vdc Batt. 23A 25mA 19 POA1 Indice: 1 pag. 2 2.1 2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 21 21 21 22 22 22 23 23 24 3 27 4 27 5 27 24 25 26 26 6 6.1 6.2 6.3 6.4 27 27 28 28 28 7 7.1 7.1.1 7.1.2 7.2 7.3 7.4 7.5 29 29 30 30 31 31 31 32 8 33 9 9.1 33 33 10 33 11 Caratteristiche tecniche 34 Appendice 35 20 E F G H I L I M 4 5 6 7 8 9 10 11 12 13 14 15 16 L1...L5 D P1 P2 C P3 B 1 A N O 4 TO 2 1 5 FOTO 2 7 FO 6 FOTO 1 21 M1 ANTENNA PASSO PASSO (NA) AUX (NA) FOTO (NC) FOTO1 (NC) COMUNE ALT (NC) 24Vd.c. - + + PONTICELLO E 0V M2 +24Vd.c. FOTOTEST LAMPEGGIANTE 24Vd.c. M1 - M2 N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ALIMENTAZIONE DA RETE L 3 22 I PASSO PASSO ALT NC NO C C PASSO PASSO NO NC AUX NC NO 15 15 11 11 11 11 12 C C NO NC 16 Esempio 1 Esempio 2 6 24Vdc max 5W 7 12Vac max 25VA 6 7 23 Tabella 1 NA NC 8,2KΩ NA (nota 2) NC (nota 2) In serie (nota 3) In serie In serie (nota 4) 8,2KΩ NC 11 11 NA 11 NA NA NC 8,2KΩ 8,2KΩ 12 12 4 8,2KΩ 12 5 6 1 11 12 NC n 2 Bordo Sensibile Bordo Sensibile 8,2KΩ Bordo Sensibile 7 11 TX RX 14 1 2 10 9 FOTO 10 9 11 13 FOTO 1 2 3 4 5 1 2 1 2 3 4 5 10 9 11 13 10 9 TX 1 2 10 9 10 9 24 11 14 1 2 3 4 5 TX 1 2 1 2 3 4 5 10 9 11 13 10 9 FOTO 1 1 2 I RX TX 1 2 3 4 5 10 9 11 14 10 9 TX 1 2 1 2 3 4 5 10 9 11 16 10 9 TX FOTO 1 2 1 2 3 4 5 10 9 11 13 8 9 TX 1 2 1 2 3 4 5 10 9 11 14 8 9 8 RX 1 2 8 9 1 2 3 4 5 1 2 3 4 5 10 9 11 13 14 FOTO 8 9 10 9 11 13 TX 1 2 1 2 3 4 5 10 9 11 14 8 9 TX 1 2 1 2 3 4 5 10 9 8 9 11 16 25 INGRESSO ALT FOTO FOTO1 P.P. AUX TIPO INGRESSO ALT NC ALT RESISTENZA COSTANTE 8,2KΩ APRE PARZIALE tipo 1 APRE PARZIALE tipo 2 SOLO APRE SOLO CHIUDE FOTO2 M1 8 9 26 I : : : : • • • • • • • • • : : : : : : : : : 27 28 I Led L1 Led L2 Led L3 Led L4 Led L5 Led L1 Led L2 Chiusura automatica Ritardo in apertura Fototest Led L3 Led L4 Led L5 Led L1 Led L2 Led L3 Led L4 Led L5 Led L1 Led L2 Chiusura automatica Ritardo in apertura Fototest Parametro: Led L3 Led L4 Led L5 Parametro: Parametro: Parametro: Tempo pausa Ingresso AUX L1: 5s L1: Apre L1: 2s parziale TIPO 1 L1: 5%s L2: 10s L2: Grado 2 L2: 10% L3: 20s L3: 6s L3: Grado 3 L3: 20% L4: 40s L4: Solo Chiude L4: 8s L4: Grado 4 L4: 30% L5: 80s L5: 10s 29 Tabella “A2” 1. Esempio Esempio P1 P2 3s P1 2. Tabella “A3” 1. Esempio P3 Tabella “A4” 1. Esempio P1 Tabella “A5” 1. P2 3s Esempio P1 oppure 3s 60s, oppure Esempio P1 2. P2 3s 3. Tabella “B2” 1. 3s Esempio P2 Tabella “B3” 1. Esempio P1 Tabella “B4” 1. Esempio P1 Tabella “B5” 1. 3s Esempio 3s P1 oppure oppure 30 P2 60s, 3. 4. I Esempio P1 P2 P1 P2 3s 1. Esempio P1 2. 3s P2 3s 3. P2 2 4. 5. P1 6. 7. P1 1. Esempio P1 2. P2 4 P1 x3 3. 3s 4. 3s P2 x3 5. 6. P1 P2 3s 31 P1 Foto Foto 1 Passo Passo AUX P2 P3 P1+P2 per 3 sec P1 per 3 sec (non salva) P1+P2 per 3 sec (salva) - Prima P1! P1 Chius. Cond. Auto Prel. Rich. Dopo foto Rit. Aper. P2 P1 On Off P3 Fotot. Elettros. ALT Res. SCA Prop. P3 P2 P3 TEMPO PAUSA P2 per 3 sec P1 P1 5 10 20 40 80 P2 P3 INGRESSO AUSILIARIO (*) P1 a.p. a.p. Tipo 1 Tipo 2 P2 P3 TEMPO DI PRELAMPEGGIO P1 2 4 6 8 10 P2 P1 1 2 3 4 5 (*) a.p. TIPO 1 P2 grado P3 a.p. TIPO 2 Solo Apre Foto 2 P1 5 10 20 30 40 P2 % P3 32 On Off I 33 34 smxi smif smxis ricevitore radio I 35 1b Tabella “B1” 1. 2. Esempio RX 3s RX 3. TX 2s x3 Esempio RX 2s TX x3 Tabella “B3” 1. 2. 3. Esempio x5s TX TX 1s TX TX 36 1s TX TX 1s x1 1. Esempio RX 2. 3. I x3 RX 3° x5 SMXI Rolling code a 52 bit FLOR FLOR, VERY VR FLOR 1–2-4 12Vdc Batt. 23A 10mA FLO 1–2-4 12Vdc Batt. 23° 15mA 433.92MHz -40°C ÷ + 85°C 100µW VERY VE 2 6Vdc batt. litio 10mA SMILO 2-4 12Vdc Batt. 23A 25mA 37 2 2.1 2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 page page 39 6 6.1 6.2 6.3 6.4 7 7.1 7.1.1 7.1.2 7.2 7.3 7.4 7.5 47 47 48 48 49 49 49 50 8 51 39 39 40 40 40 41 41 42 42 3 45 9 9.1 51 51 4 45 10 51 5 45 11 52 43 44 44 Appendice 53 38 E F G H I L M F 4 5 6 7 8 9 10 11 12 13 14 15 16 L1...L5 D P1 P2 C P3 B 1 A N O 4 TO 2 1 5 PHOTO 2 7 PHO 6 PHOTO 1 39 M1 + ANTENNE PAS-à-PAS (NO) AUX (NO) PHOTO1 (NF) PHOTO (NF) COMMUN HALTE (NF) 24Vd.c. 0V + +24Vd.c. PHOTO-TEST Clignotant 24Vd.c. M2 - M1 - M2 N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ALIMENTATION L 3 40 F HALTE AUX NC NO C C NO NC NC NO 15 15 11 11 11 11 12 C C NO NC 16 Exemple 1 24Vdc max 5W 7 12Vac max 25VA 6 7 41 1er dispositif type: NO NF 8,2KΩ NO (note 2) NF (note 1) (note 4) 8,2KΩ NF NC 11 11 NO NA 11 NO NA NA NO NO NC 8,2KΩ 8,2KΩ 12 12 4 8,2KΩ 12 5 6 1 11 12 NC NO n 2 8,2KΩ 7 11 14 1 2 10 9 RX PHOTO FOTO 10 9 11 13 TX RX PHOTO FOTO 1 2 3 4 5 1 2 1 2 3 4 5 10 9 11 13 10 9 TX 1 2 RX PHOTO FOTO 1 1 10 9 10 9 42 11 14 1 2 3 4 5 TX RX PHOTO FOTO 1 2 1 2 3 4 5 10 9 11 13 10 9 RX TX PHOTO FOTO 1 1 1 2 1 2 3 4 5 10 9 11 14 10 9 TX RX PHOTO FOTO 2 2 1 2 F 1 2 3 4 5 10 9 11 16 10 9 TX PHOTO FOTO 1 2 1 2 3 4 5 10 9 11 13 8 9 TX RX PHOTO FOTO 1 1 1 2 1 2 3 4 5 10 9 11 14 8 9 8 RX 1 2 8 9 1 2 3 4 5 1 2 3 4 5 10 9 11 13 14 PHOTO FOTO RX PHOTO FOTO 8 9 10 9 11 13 TX RX PHOTO FOTO 1 1 1 2 1 2 3 4 5 10 9 11 14 8 9 TX 1 2 RX PHOTO FOTO 2 2 1 2 3 4 5 10 9 8 9 11 16 43 PHOTO PHOTO1 PAS-À-PAS AUX TYPE ENTRÉE STOP NF STOP RÉSISTANCE CONSTANTE 8,2KΩ OUV. PARTIELLE type 1 OUV. PARTIELLE type 2 SEULEMENT OUVERTURE SEULEMENT FERMETURE PHOTO2 8 9 44 F : : : : • • • • • • • • • 45 46 F Led L1 Led L2 Led L1 Led L2 Led L3 Led L4 Led L5 Phototest Led L3 Led L4 Led L5 Led L1 Led L2 Led L1 Led L2 Led L3 Led L4 Led L5 Phototest Led L3 Led L4 Led L5 L1: 5s L1: 5%s L2: 10s L2: 10% L3: 20s L3: 20% L4: 40s L4: 30% L5: 80s L5: Photo 2 L5: 10s 47 P1 P2 3s P1 2. P2 3s 3s 60s, ou P2 3s P1 P2 3s Tableau “B3” 1. 3s P1 ou ou 48 P2 60s, Exemple P1 3. 4. P2 F P1 P2 3s 1. 2. 3. 4. 5. P1 3s P2 3s 2 P1 x1 P2 P3 2 P1 6. P2 7. P1 1. 2. P1 P2 4 P1 x3 3. 3s 4. 3s P2 x3 5. 6. P1 P2 3s 49 P1 Led P1 Clignotement lent HALTE Photo Photo 1 AUX P2 P3 P1+P2 pendant 3 s P1 pendant 3 s (ne pas sauvegarder) P1+P2 pendant 3 s (sauvegarder) - P1 d’abord! P1 Autom. Collectif Précl. Referme Décalage ap. photo P2 P1 On Off P3 Photot. Serrure Stop Portails SCA résistif lourds proport. P3 P2 P3 P1 P1 5 10 20 40 80 P2 P1 o.p. o.p. type 1 type 2 ferme Photo 2 seul. P2 P3 P1 2 4 6 8 10 P2 P1 1 2 3 4 5 (*) o.p. Type 1 P2 degré P3 o.p. Type 2 ferme ➔ stop ➔ ferme ➔ stop... [contact NO] Photo 2 P1 5 10 20 30 40 P2 % P3 50 On Off 51 52 53 1b 1. 2. RX 3s RX 3. TX 2s x3 RX 2s TX x3 1. 2. 3. TX TX 1s TX TX 54 1s TX TX 1s x1 1. 2. 3. x3 RX 3° x5 SMXIF 1024 combinaisons FLO FLO, VERY VE FLOR 1–2-4 12Vdc pile 23A 10mA VERY VR 2 6Vdc pile lithium 10mA FLO 1–2-4 12Vdc pile 23° 15mA 433.92 MHz -40°C ÷ + 85°C 100 µW VERY VE 2 6Vdc pile lithium 10mA SMILO 2-4 12Vdc pile 23A 25mA 55 S. 1 57 2 2.1 2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 57 57 58 58 58 59 59 60 60 62 62 3 63 4 Diagnose 63 5 63 61 S. 6 6.1 6.2 6.3 6.4 63 63 64 64 64 7 7.1 7.1.1 7.1.2 7.2 7.3 7.4 7.5 65 65 66 66 67 67 67 68 8 69 9 9.1 69 69 10 Was tun, wenn... 69 11 70 Anhang 71 56 E F G H 1 2 3 4 5 6 7 I L M 8 9 10 11 12 13 14 15 16 L1...L5 D P1 D P2 C P3 B N 1 A O 4 TO 2 1 5 FOTO 2 7 FO 6 FOTO 1 3. 4. 5. 6. 7. 57 M1 ANTENNE AUX (NO) STOP (NC) FOTO (NC) FOTO1 (NC) 24Vd.c. - + + 0V M2 M1 +24Vd.c. PHOTOZELLENTEST - M2 N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NETZSTROMVERSORGUNG L 3 58 D STOP NC NO C C NO NC AUX NC NO 15 15 11 11 11 11 12 C C NO NC 16 24Vdc max 5W 7 12Vac max 25VA 6 7 59 NO NC 8,2KΩ NO (Anmerkung 2) NC (Anmerkung 2) 8,2KΩ parallelgeschaltet parallelgeschaltet NC 11 11 NO NA 11 NO NA NA NO NO NC 8,2KΩ 8,2KΩ 12 12 4 8,2KΩ 12 5 6 1 11 12 NC NO n 2 8,2KΩ 7 TX 11 RX TX RX 14 1 2 10 9 FOTO 10 9 11 13 FOTO 1 2 3 4 5 1 2 1 2 3 4 5 10 9 11 13 10 9 TX 1 2 10 9 10 9 60 11 14 1 2 3 4 5 TX 1 2 1 2 3 4 5 10 9 11 13 10 9 RX TX FOTO 1 1 2 1 2 3 4 5 10 9 11 14 10 9 TX 1 2 1 2 3 4 5 10 9 D 11 16 10 9 TX FOTO 1 2 1 2 3 4 5 10 9 11 13 8 9 TX 1 2 1 2 3 4 5 10 9 11 14 8 9 TX 8 1 2 8 9 FOTO 1 2 3 4 5 8 9 10 9 11 13 1 2 3 4 5 10 9 11 13 RX 14 TX 1 2 1 2 3 4 5 10 9 11 14 8 9 TX 1 2 1 2 3 4 5 10 9 11 16 61 FOTO FOTO1 P.P. AUX TEILÖFFNUNG Typ 1 TEILÖFFNUNG Typ 2 NUR ÖFFNUNG NUR SCHLIEßUNG FOTO2 62 M1 9 8 D : : : : • • • • • • • • • : : : : : : : : : 63 64 Led L1 Led L2 Led L3 Led L4 Led L5 Led L1 Led L2 Led L3 Led L4 Led L1 Led L2 Led L3 Led L4 Led L5 Led L1 Parameter: Led L2 Led L3 Led L4 Parameter: Parameter: Parameter: Eingang AUX L1: 5s L1: 2s L1: 5%s L2: 10s L2: 4s L2: 10% L3: 20s L3: 20% L4: 40s L4: 30% L5: 80s L5: 10s 65 Tabelle “A2” 1. P1 P2 3s P1 2. Tabelle “A3” 1. Tabelle “A4” 1. Tabelle “A5” 1. P2 3s 3s 60s, oder P2 P1 P2 Tabelle “B2” 1. 3s 3s Tabelle “B3” 1. Tabelle “B4” 1. Tabelle “B5” 1. 3s oder 66 P2 60s, Tabelle “C1” 1. 2. 3. 4. P1 P2 P1 P2 3s 1. 2. P1 P1 x1 3. P2 3s P2 3s 2 4. 5. P1 6. 7. P1 1. 2. P1 P2 4 P1 x3 3. 3s 4. 3s P2 x3 5. 6. P1 P2 3s 67 Foto Led P1 Langsamblinken Foto 1 AUX P2 P3 P3 P3 Stop durch resistiven Widerstand On Off P2 P1 P1+P2 3 Sek.lang P2 On Off P3 PAUSEZEIT P2 3 Sek.lang P1 P1 5 10 20 40 80 P2 P3 HILFSEINGANG (*) o.p. Typ 1 o.p. Typ 2 P1 Foto 2 P2 P3 P1 2 4 6 8 10 P2 P3 ANSPRECHVERMÖGEN STROMMESSUNG P1 1 2 3 4 5 (*) T.Ö. Typ 1 P2 Stufe P3 T.Ö. Typ 2 P1 5 10 20 30 40 P2 % P3 68 69 70 smxi smif smxis Funkempfänger D 71 1b Tabelle “B1” 1. 2. RX 3s RX 3. TX 2s x3 1. RX 2s TX x3 Tabelle “B3” 1. 2. 3. TX TX 1s TX TX 72 1s TX TX 1s x1 1. 2. 3. x3 RX 3° x5 SMXIF 1024 Kombinationen FLO D FLOR 1–2-4 12Vdc Batt. 23A 10mA VERY VR 2 6Vdc Lithiumbatt. 10mA FLO 1–2-4 12Vdc Batt. 23° 15mA 433.92MHz -40°C ÷ + 85°C 100µW VERY VE 2 6Vdc Lithiumbatt. 10mA SMILO 2-4 12Vdc Batt. 23A 25mA 73 pág. 2 2.1 2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 75 75 75 76 76 76 77 77 78 78 3 Ensayo 81 4 81 5 81 79 80 80 6 6.1 6.2 6.3 6.4 81 81 82 82 82 7 7.1 7.1.1 7.1.2 7.2 7.3 7.4 7.5 83 83 84 84 85 85 85 86 8 87 9 9.1 87 87 10 Qué hay que hacer si... 87 11 88 89 74 E F G H I L M 4 5 6 7 8 9 10 11 12 13 14 15 16 L1...L5 P1 D F: Borne motor M2 G: Borne salida luz intermitente P2 C P3 E B 1 N O A 4 7 2 ULA CÉL O T FO 6 1 2 75 M1 ANTENA PASO A PASO (NA) AUX (NA) FOTOCÉLULA (NC) FOTOCÉLULA 1 (NC) 24Vd.c. 0V - + + +24Vdc FOTOTEST M2 M1 - M2 N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3 76 E PASO A PASO STOP NC NA C C PASO A PASO NA NC AUX NC NA 15 15 11 11 11 11 12 C C NA NC 16 Ejemplo 1 Ejemplo 2 6 24Vdc max 5W 7 12Vac max 25VA 6 7 77 Tabla 1 NA NC 8,2KΩ NA (nota 2) NC (nota 2) En serie (nota 3) En serie En serie (nota 4) 8,2KΩ NC 11 11 NA 11 NA NA NC 8,2KΩ 8,2KΩ 12 12 4 8,2KΩ 12 5 6 1 11 12 NC n 2 8,2KΩ 7 11 14 1 2 10 9 10 9 11 13 TX 1 2 3 4 5 1 2 1 2 3 4 5 10 9 11 13 10 9 TX 1 2 10 9 10 9 78 11 14 1 2 3 4 5 TX 1 2 1 2 3 4 5 10 9 11 13 10 9 RX TX FOTOCÉLULA FOTO 1 1 1 2 1 2 3 4 5 10 9 11 14 10 9 TX 1 2 1 2 3 4 5 10 9 11 16 10 9 1 2 E RX TX 1 2 3 4 5 10 9 11 13 8 9 TX 1 2 1 2 3 4 5 10 9 11 14 8 9 8 RX 1 2 8 9 1 2 3 4 5 1 2 3 4 5 10 9 11 13 8 9 10 9 11 13 TX 1 2 1 2 3 4 5 10 9 11 14 8 9 TX 1 2 1 2 3 4 5 10 9 8 9 11 16 79 FOTOCÉLULA FOTOCÉLULA1 P.P. AUX TIPO ENTRADA STOP NC STOP RESISTENCIA CONSTANTE 8,2KΩ ABRIR PARCIAL tipo 1 ABRIR PARCIAL tipo 2 SÓLO ABRIR SÓLO CERRAR FOTOCÉLULA2 L2 Encendido L3 Encendido L4 Apagado L5 Apagado L5 Apagado L5 Apagado L5 Apagado L5 Encendido 80 M1 ESTADO LED L1 Encendido L1 Encendido 9 8 E Movimiento motores Cierre automático Comunitario Destello previo : : : : • • • • • • • • • 81 82 E Led L1 Led L2 Led L3 Led L1 Led L2 Fototest Led L4 Led L5 Led L3 Led L4 Led L5 Led L1 Led L2 Led L3 Led L1 Led L2 Fototest Led L4 Led L5 Led L3 Led L4 Led L5 Puertas pesadas Segundo nivel: Parámetro: Parámetro: Parámetro: Entrada AUX Parámetro: Parámetro: Tiempo de retardo hoja L1: 5s L1: Abrir parcial tipo1 L1: 2s L1: 5%s L2: 10s L2: Abrir parcial tipo 2 L2: 4s L2: Grado 2 L2: 10% L3: 20s L3: Sólo Abrir L3: 6s L3: Grado 3 L3: 20% L4: 40s L4: Sólo Cerrar L4: 8s L4: Grado 4 L4: 30% L5: 80s Todos los Leds apagados: entrada no usada Todos los Leds apagados: Grado 6 (sistema amperimétrico máx.) 83 Tabla “A2” 1. Ejemplo Ejemplo P1 P2 3s P1 2. Tabla “A3” 1. Ejemplo P3 Tabla “A4” 1. Ejemplo P1 Tabla “A5” 1. P2 3s Ejemplo P1 3s o 60s, o Ejemplo P1 P2 3s P1 3. Tabla “B2” 1. P2 3s Ejemplo P2 Tabla “B3” 1. Ejemplo P1 Tabla “B4” 1. Ejemplo P1 Tabla “B5” 1. 3s Ejemplo 3s P1 o o 84 P2 60s, 3. 4. Ejemplo P1 P2 P1 P2 3s 1. 2. P1 P1 x1 3. E Ejemplo P2 3s P2 3s 2 4. 5. P1 6. 7. P1 1. 2. Ejemplo P1 P2 4 P1 x3 3. 3s Pase al segundo nivel presionando P2 durante 3 segundos como mínimo P2 4. 3s P2 x3 5. 6. P1 P2 3s 85 P1 AUX P2 P3 P1+P2 por 3 seg P1 por 3 seg (no memorizar) P1+P2 por 3 seg (memorizar) - Primero P1! P1 P2 P1 On Off P3 P3 P2 P3 TIEMPO DE PAUSA P2 por 3 seg P1 P1 5 10 20 40 80 P2 segundos P3 ENTRADA AUXILIAR (*) P1 a.p. a.p. Tipo 1 Tipo 2 P2 P3 TIEMPO DE DESTELLO PREVIO P1 2 4 6 8 10 P2 segundos P1 1 2 3 4 5 (*) a.p. TIPO 1 P2 grado P3 a.p. TIPO 2 Sólo Abrir abrir ➔ stop ➔ abrir ➔ stop... [contacto N.A.] cerrar ➔ stop ➔ cerra ➔ stop... [contacto N.A.] todos los Leds apagados ➡ sistema amperimétrico max RETARDO DURANTE APERTURA P1 5 10 20 30 40 P2 % 86 On Off E 87 88 smxi smif smxis radiorreceptor E 89 1b 1. 2. Ejemplo RX 3s RX 3. TX 2s x3 Ejemplo 1. RX 2s TX x3 Tabla “B3” 1. 2. 3. Ejemplo x5s TX TX 1s TX TX 90 1s TX TX 1s x1 1. Ejemplo RX 2. 3. x3 RX 3° x5 SMXI Rolling code a 52 bit FLOR FLOR, VERY VR E FLOR 1–2-4 12Vdc Bat. 23A 10mA VERY VR 2 6Vdc bat. litio 10mA FLO 1–2-4 12Vdc Bat. 23° 15mA 433.92MHz -40°C ÷ + 85°C 100µW VERY VE 2 6Vdc bat. litio 10mA SMILO 2-4 12Vdc Bat. 23A 25mA 91 6.4 7 7.1 7.1.1 7.1.2 7.2 7.3 7.4 7.5 8 105 99 9 9.1 105 105 99 10 Co robić gdy 105 11 106 107 1 Opis produktu 93 2 2.1 2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 93 93 94 94 94 95 95 96 96 3 99 4 Diagnostyka 5 2.3.6 2.3.7 2.4 pag. pag. 97 98 98 6 6.1 6.2 6.3 99 99 100 100 100 92 E F G H I L M 4 5 6 7 8 9 10 11 12 13 14 15 16 L1...L5 D P1 P2 C I: P3 B N 1 A O PL 4 TO 2 1 5 FOTO 2 7 FO 6 FOTO 1 5. 6. 7. 8. 9. 93 ANTENA FOTO(NC) FOTO1(NC) 8 9 10 11 12 13 14 15 16 6 7 24Vd.c. - + + 0V M2 +24Vps FOTOTEST M1 SCA(kontrolka stanu bramy)/ Elektrozamek - M2 N 1 2 3 4 5 3 94 PL STOP NC NO C C KROK PO KROKU NO NC AUX NC NO 15 15 11 11 11 11 12 C C NO NC 16 24Vdc max 5W 7 12Vac max 25VA 6 7 95 NA NA (uwaga 2) NC (uwaga 2) (uwaga 4) 8,2KΩ NC 11 11 NA 11 NA NA NC 8,2KΩ 8,2KΩ 12 12 4 8,2KΩ 12 5 11 12 NC 6 1 2 n 8,2KΩ 7 11 TX RX 14 1 2 10 9 FOTO 10 9 11 13 FOTO 1 2 3 4 5 1 2 1 2 3 4 5 10 9 11 13 10 9 TX 1 2 10 9 10 9 96 11 14 1 2 3 4 5 TX 1 2 1 2 3 4 5 10 9 11 13 10 9 RX TX FOTO 1 1 2 1 2 3 4 5 10 9 11 14 10 9 TX 1 2 1 2 3 4 5 10 9 11 16 10 9 TX FOTO 1 2 1 2 3 4 5 10 9 11 13 8 9 TX 1 2 PL 1 2 3 4 5 10 9 11 14 8 9 testu. 8 RX 1 2 8 9 1 2 3 4 5 1 2 3 4 5 10 9 11 13 14 FOTO 8 9 10 9 11 13 TX 1 2 1 2 3 4 5 10 9 11 14 8 9 TX 1 2 1 2 3 4 5 10 9 8 9 11 16 97 9 98 Mostek E M2 8 Typ anomalii PL • • • • • • • • • : : : : : : : : : 99 100 Doda L1 Doda L2 Doda L3 Doda L5 Doda L1 Doda L2 Doda L3 Doda L4 Doda L5 Fototest Elektrozamek Doda L4 Doda L1 Doda L2 Doda L3 Doda L5 Doda L1 Doda L2 Doda L3 Doda L4 Doda L5 Fototest Elektrozamek Parametr: Doda L4 Drugi poziom: Parametr: Parametr: Parametr: Parametr: L1: 5s L2: 10s L2: 10% L3: 20s L3: 20% L4: 40s L4: 30% L5: 80s L5: 40% L5: 10s 101 PL Tabela “A2” 1. 2. Esempio P1 P2 3s P1 P2 Tabela “A3” 1. Tabela “A4” 1. Tabela “A5” 1. P1 P2 P1 oppure 3s 60s, oppure P2 P1 P2 Tabela “B2” 1. 3s 3s Tabela “B3” 1. Tabela “B4” 1. Tabela “B5” 1. 3s P1 oppure oppure 102 P2 60s, 3. 4. P1 P2 P1 P2 3s 1. 2. P1 3s 2 P1 x1 3. P2 PL 4. 5. P1 6. 7. P1 P2 3s P1 P2 4 P1 x3 3. 3s 4. 3s P2 x3 5. 6. P1 P2 3s 103 'LRGD3Eá\VNDZROQR $8; P2 P3 P1 3R]LRP 'LRGD3ĞZLHFLQDVWDáH P2 P1 :á :\á P3 P3 P2 :á :\á P3 CZAS PAUZY 3 SU]H]V P1 3 5 10 20 40 80 P2 P3 :(-ĝ&,(81,:(56$/1($8; P1 3R]LRP 'LRGD3Eá\VNDV]\ENR IXUWNDIXUWND W\ONR W\ONR )RWR W\S W\S RWZLHUD ]DP\ND P2 P3 :&=(ĝ1,(-6=(ĝ:,(&(1,(/$03< P1 2 4 6 8 10 P2 P3 6,à$1$&,6.86.5=<'%à P1 1 2 3 4 5 (*) a.p. typ 1 P2 3R]LRP P3 a.p. typ 2 :V]\VWNLHGLRG\]JDV]RQH ➡ QDMZLĊNV]DVLáD 23Ïħ1,(1,('58*,(*26.5=<'à$ P1 5 10 20 30 40 P2 % P3 Foto 2 104 105 PL : : : : : : : : : : : : Temperatura pracy 106 smxi smif smxis odbiornik radiowy PL 107 1b Tabela “B1” 1. 2. 3. RX 3s RX 2s TX x3 RX 2s TX x3 1. 2. 3. TX TX 1s TX 1s TX 108 TX TX 1s x1 1. 2. 3. RX x3 RX 3° x5 SMXIF 1024 kombinacji FLO FLO, VERY VE FLOR 1-2-4 12Vps bat. 23A 10mA VERY VR 2 6Vps bat. litowe 10mA FLO 1-2-4 12Vps bat. 23A 15mA 433.92MHz -40°C ÷ + 85°C 100µW VERY VE 2 6Vps bat. litowe 10mA SMILO 2-4 12Vdc Batt. 23A 25mA PL 109 2 2.1 2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 pag. pag. 111 111 111 112 112 112 113 113 114 3 117 4 Diagnostiek 117 5 117 114 115 116 116 6 6.1 6.2 6.3 6.4 117 117 118 118 118 7 7.1 7.1.1 7.1.2 7.2 7.3 7.4 7.5 119 119 120 120 121 121 121 122 8 123 9 9.1 Onderhoud van de besturingseenheid POA1 Afvalverwerking 123 123 10 123 11 124 125 110 E F G H I L Besturingseenheid POA1 M A: Stekker stroomvoorziening 24V 1 2 3 4 5 6 7 B: Stekker motor M1 8 9 10 11 12 13 14 15 16 C: Stekker voor bufferbatterij PS124 L1...L5 D F: Klemmetje motor M2 P1 P2 I: C L: Klemmetjes voor ingangen P3 L1…L5: Ledlampjes ingangen en programmering B N N: Plug in”SM” voor radio-ontvanger O: Stekker voor programmering / diagnostiek 1 A O NL 4 TO 2 1 5 FOTO 2 7 FO 6 FOTO 1 3. Knipperlicht 4. Sleutelschakelaar 5. Stel fotocellen “FOTO” 6. Stel fotocellen “FOTO1” 7. Stel fotocellen “FOTO2” 111 Jumper “E” M2 + ANTENNE FOTO (NC) FOTO1 (NC) 24Vd.c. + 0V KNIPPERLICHT 24Vd.c. M2 - M1 +24Vd.c. FOTOTEST - M2 N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 3 112 Functies Kabel stroomvoorz. Motor 2 Waarschuwingslicht SCA/ElektroS. STOP NC NO C C STOP NO NC Aansluiting sleutelschakelaar NC NO 15 15 11 11 11 11 12 C C NO NC 16 24Vdc max 5W 7 12Vac max 25VA 6 7 113 Tabel 1 1ste inrichting type: 2de inrichting type: NO NC NO NC (opmerking 2) 8,2KΩ (opmerking 4) NC 11 11 NO NA 11 NO NA NO NA NC 8,2KΩ 8,2KΩ 12 12 4 8,2KΩ 12 5 11 12 NC 6 1 2 n 8,2KΩ 7 11 Aansluiting van FOTO en FOTO1 RX TX RX 14 1 2 10 9 FOTO 10 9 11 13 FOTO 1 2 3 4 5 1 2 1 2 3 4 5 10 9 11 13 10 9 TX 1 2 10 9 10 9 114 11 14 1 2 3 4 5 Aansluiting van FOTO FOTO1 en FOTO2 (de ingang AUX dient als FOTO2 geprogrammeerd te worden) TX 1 2 1 2 3 4 5 10 9 11 13 10 9 RX TX FOTO 1 1 2 1 2 3 4 5 10 9 11 14 10 9 TX 1 2 1 2 3 4 5 10 9 11 16 10 9 Aansluiting van FOTO e FOTO1 RX TX FOTO 1 2 1 2 3 4 5 10 9 11 13 8 9 TX 1 2 1 2 3 4 5 NL 10 9 11 14 8 9 Aansluiting van FOTO FOTO1 en FOTO2 (de ingang AUX dient als FOTO2 geprogrammeerd te worden) staande afbeeldingen voor voorbeelden van aansluiting. TX Aansluiting enkel van de fotocel FOTO 1 2 TX 8 RX 1 2 8 9 1 2 3 4 5 1 2 3 4 5 10 9 11 13 14 FOTO 8 9 10 9 11 13 TX 1 2 1 2 3 4 5 10 9 11 14 8 9 TX 1 2 1 2 3 4 5 10 9 8 9 11 16 115 FOTO FOTO1 P.P. AUX TYPE INGANG STOP NC STOP CONSTANTE WEERSTAND 8,2KΩ GEDEELTELIJKE OPENING type 1 GEDEELTELIJKE OPENING type 2 OPEN ALLEEN SLUIT ALLEEN FOTO2 116 M1 Jumper “E” M2 9 8 Aantal Soort anomalie Knipperingen led P2 1 Inwerkingtreding stroommeting van M1 2 Inwerkingtreding stroommeting van M2 3 Inwerkingtreding ingang STOP tijdens de manoeuvre 4 Fout Fototest 5 Overstroom uitgang SCA of elektrisch slot • • • • • • • • • wanneer de besturingseenheid niet geprogrammeerd wordt. Wanneer het ledlampje P3 niet brandt, betekent dit dat de langzame beweging is ingesteld, wanneer het brandt dat de snelle beweging is ingesteld. 117 NL 118 Led L1 Led L2 Led L3 Led L5 Led L1 Led L2 Led L3 Led L4 Led L5 Functie woonblok Voorwaarschuwing Terugloop na foto Fototest Stop door weerstand Led L4 NL Led L1 Led L2 Led L3 Led L5 Led L1 Led L2 Led L3 Led L4 Led L5 Functie woonblok Voorwaarschuwing Terugloop na foto Fototest Parameter: Led L4 Parameter: Parameter: Pauzeduur Ingang AUX Duur Gevoeligheid voorwaarschuwing stroommeting L1: 5s L1: 5%s L2: 10s L2: graad 2 L2: 10% L3: 20s L3: graad 3 L3: 20% L4: 40s L4: 8s L4: graad 4 L4: 30% L5: 80s L5: 10s L5: graad 5 (geringere gevoeligheid) L5: 40% Alle LED uit: ingang niet gebruikt Parameter: Vertraging vleugel Alle LED uit Graad 6 (max stroommeting) 119 Tabel “A2” 1. Binnengaan in de programmering eerste niveau: Houd de toetsen P1 en P2 tenminste 3 seconden ingedrukt. Un lampeggio veloce di tutti i Led indica che si è entrati in programmazione P1 P2 3s P1 2. Tabel “A3” 1. Tabel “A4” 1. Tabel “A5” 1. P2 3s 3s of 60s, of P2 P1 P2 Tabel “B2” 1. 3s 3s Tabel “B3” 1. Teruggaan naar het eerste niveau: Druk op P1 Tabel “B4” 1. Tabel “B5” 1. 3s Voorbeeld 3s P1 of of 120 P2 60s, 3. 4. P1 P2 P1 P2 3s 1. 2. P1 P1 x1 3. P2 3s 2 4. 5. 6. 2 P1 NL P2 7. P1 P2 3s 1. 2. P1 P2 4 P1 x3 3. 3s 4. 3s P2 x3 5. Ga terug naar het eerste niveau door op P1 te drukken P1 6. P1 P2 3s 121 Normale Werking P1 Led P1 knippert langzaam STOP Foto Foto 1 AUX P2 P3 P1+P2 gedurende 3 sec. P1 gedurende 3 sec. (bewaart niet) P1+P2 gedurende 3 sec. (bewaart) - Eerst P1! P1 Eerste niveau Led P1 brandt continu Auto. Woonbl. VrW. Sluiten Terug Vertr. na foto Open. P2 P1 On Off P3 Fotot. Elektros. STOP Zware SCA Wrst. Poorten Prop. P3 P2 On Off P3 P1 P1 5 10 20 40 80 P2 seconden P3 HULPINGANG (*) P1 Tweede niveau Led P1 knippert snel a.p. a.p. Alleen Alleen Foto 2 Type 1 Type 2 openen sluiten P2 P3 P1 2 4 6 8 10 P2 P1 1 2 3 4 5 (*) a.p. TYPE 1 P2 graad P3 a.p. TYPE 2 P1 5 10 20 30 40 sluit ➔ stop ➔ sluit ➔ stop... [contact N.O.] Foto 2 Gebruikt als foto 2 [contact N.C.] P3 122 P2 % 123 124 smxi smif smxis radio-ontvanger 125 1b Tabel “B1” 1. Druk op de toets op de ontvanger en houd die tenminste 3 seconden ingedrukt 2. RX 3s RX 3. TX 2s x3 1. RX 2s TX x3 Tabel “B3” Geheugenopslag op afstand 1. 2. 3. Voorbeeld x5s TX TX 1s TX 1s TX TX TX 126 1s x1 1. Druk op de toets op de ontvanger en houd die ingedrukt RX 2. 3. x3 RX 3° x5 Technische gegevens Ontvangers SMXI Rolling code 52 bits FLOR FLOR, VERY VR SMXIF 1024 combinaties FLO FLO, VERY VE FLOR 1–2-4 12Vdc Batt. 23A 10mA VERY VR 2 6Vdc lithiumbatterij 10mA FLO 1–2-4 12Vdc Batt. 23° 15mA 433.92MHz -40°C ÷ + 85°C 100µW VERY VE 2 6Vdc lithiumbatterij 10mA SMILO 2-4 12Vdc Batt. 23A 25mA Data / Date: 09/2002 Il sottoscritto Lauro Buoro, Amministratore Delegato, dichiara che il prodotto: The undersigned Lauro Buoro, General Manager of the following producer, declares that the product: Nome produttore / Producer name: Indirizzo / Address: Tipo / Type: Modello / Model: 1997 EN300220-3 2000 EN60950 2nd ed. 1992 Radio Equipment and Systems (RES); Electromagnetic Compatibility (EMC) standard for Classe II Short Range Devices (SRD) operating on frequencies between 9KHz and 25GHz APPARATI RADIO E SISTEMI Classe I (LPD) CARATTERISTICHE TECNICHE E METODI DI MISURA PER APPARATI RADIO TRA 25MHz A 1000MHz Radio Equipment and Sistems- Short Range Devices-Technical characteristics and test methods for radio radio equipment between 25MHz and 1000 MHz REGOLAZIONE ALL’USO DEI DISPOSITIVI A CORTO RAGGIO/Regolating to the use of short range devices (SRD) APPARECCHIATURE PERLA TECNOLOGIA DELL’INFORMAZIONE. SICUREZZA. +A1: 1993 + A2: 1993 + A3: 1995 + A4: 1997 + A11: 1997 + EN41003/1993. ODERZO, 30 September 2002 127 ✄ Risulta conforme a quanto previsto dalle seguenti direttive comunitarie / Complies with the following community directives Riferimento n° Titolo Reference n° Title 73/23/CEE DIRETTIVA 73/23/CEE DEL CONSIGLIO del 19 febbraio 1973 concernente il riavvicinamento delle legislazioni degli Stati membri relative al materiale elettrico destinato ad essere adoperato entro taluni limiti di tensione / Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limitis 89/336/CEE DIRETTIVA 89/336/CEE DEL CONSIGLIO del 3 maggio 1989, per il riavvicinamento delle legislazioni degli Stati membri relative alla compatibilità elettromagnetica / Council Directive 89/336/EEC of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility 98/37/CE (EX 89/392/CEE) DIRETTIVA 98/37/CE DEL PARLAMENTO EUROPEO E DEL CONSIGLIO del 22 giugno 1998 concernente il ravvicinamento delle legislazioni degli Stati membri relative alle macchine/DIRECTIVE 98/37/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 22 June 1998 on the approximation of the laws of the Member States relating to machinery Risulta conforme a quanto previsto Riferimento n° Edizione Reference no Issue EN60335-1 04/1998 EN60204-1 09/1993 EN55022 09/1998 EN55014-1 04/1998 ENV50204 04/199 EN61000-4-2 09/1996 EN61000-4-3 11/1997 EN61000-4-4 09/1996 EN61000-4-5 06/1997 EN61000-4-6 11/1997 EN61000-4-8 06/1997 EN61000-4-11 09/1996 08/2000 B A B A B B A A B-C dalle altre norme e/o specifiche tecniche di prodotto / Complies with the other standards and/or product technical specifications Titolo Title Porte e cancelli industriali e commerciali e da autorimessa. Sicurezza in uso di porte motorizzate - Metodi di prova Industrial, commercial and garage doors and gates - Safety in use of power operated doors - Test methods Porte e cancelli industriali e commerciali e da autorimessa. Sicurezza in uso di porte motorizzate - Requisiti Industrial, commercial and garage doors and gates - Safety in use of power operated doors - Requirements Nice France Buchelay Tel. +33.(0)1.30.33.95.95 Fax +33.(0)1.30.33.95.96 Nice Belgium Leuven (Heverlee) Tel. +32.(0)16.38.69.00 Fax +32.(0)16.38.69.01 [email protected] Nice UK Chesterfield Tel. +44.87.07.55.30.10 Fax +44.87.07.55.30.11 [email protected] Nice Gate is the doors and gate automation division of Nice Nice Screen is the rolling shutters and awnings automation division of Nice Nice China Shanghai Tel. +86.21.575.701.45/46 Fax +86.21.575.701.44 [email protected] www.niceforyou.com">
Advertisement
Automatic operation of swing gates
Maximum gate length: 2m
Maximum gate weight: 200kg
Control unit and power supply included (PP7024)
Optional battery backup
Manual release function
The PP7024 can handle gates with a maximum length of 2m and a weight of up to 200kg.
The PP7024 has a built-in control unit and power supply, while the PP7224 does not. The PP7224 connects to the PP7024 control unit.
Yes, the PP7024 can be equipped with an optional battery backup.
If the motor malfunctions, disconnect the power supply and operate the manual release device. Do not attempt to repair the motor yourself.
Nice recommends that maintenance checks be carried out every six months for normal domestic use, but this interval may vary depending on the intensity of use.
Where are the P1, P2, and P3 buttons located?
The P1, P2, and P3 buttons are located inside the housing of the POA1 control unit.