3.13 Extended I/O Ports
The PCI-9111 provides four extended input signals and four extended output signals. The signals are on the 37 pin connector. The extended output signals can be read back from the high nibble (4 MSBs) of the extended input port. Note that the output EDO pins on CN3 (37 pin connector) can be set as one of the following mode by software. The definition of the setting value can be found in header file of the library
ACL_PCI.H.
1. EDO_INPUT EDO mode 1
2. EDO_OUT_EDO EDO mode 2
3. EDO_OUT_CHN EDO mode 3
The output EDO value can be put on the EDO pins only when the EDO is set as mode 2. Under mode 1, the EDO output value will not be put on the
EDO pins, therefore the EDO signals are used as input only port. Under mode 3, the EDO pins presents the high nibble (4 MSBs) of the AD channel number no matter auto channel scan (ASCAN) bit is set or not.
Address: BASE + 4h
Attribute: write only
Data Format:
Bit 7
BASE+4h X
BASE+5h X
Address: BASE + 4h
6
X
X
5
X
X
4 3 2 1 0
X EDO3 EDO2 EDO1 EDO0
X X X X X
Attribute: read only
Data Format:
Bit 7 6 5 4 3 2 1 0
BASE+4h EDO3 EDO2 EDO1 EDO0 EDI3 EDI2 EDI1 EDI0
BASE+5h X X X X X X X X
3.14 Digital I/O register
There are 16 digital input channels and 16 digital output channels are provided by the PCI-9111. The address Base + 1C is used to access digital inputs and control digital outputs.
Address: BASE + 2h
Attribute: read only
Data Format:
20 • Registers Format
advertisement
Related manuals
advertisement
Table of contents
- 11 Features
- 12 Applications
- 12 Specifications
- 14 Software Supporting
- 14 Programming Library
- 15 Driver
- 15 PCIS-VEE: HP-VEE Driver
- 15 : ActiveX Controls
- 15 driver
- 16 Driver
- 16 PCIS-OPC: OPC Server
- 17 What You Have
- 17 Unpacking
- 18 PCI-9111's Layout
- 19 Jumper Descriptions
- 19 Hardware Installation Outline
- 20 Device Installation for Windows Systems
- 20 Connectors Pin Assignment
- 22 Daughter Board Connection
- 22 Connect with ACLD
- 22 Connect with ACLD-9138 and ACLD
- 23 PCI PnP Registers
- 24 I/O Address Map
- 24 A/D Data Registers
- 25 A/D Channel Control Register
- 26 A/D Channel Read Back Register
- 26 A/D Input Signal Range Control Register
- 27 A/D Range and Status Readback Register
- 27 A/D Trigger Mode Control Register
- 28 Software Trigger Register
- 28 Interrupt Control Register
- 29 Hardware Interrupt Clear Register
- 29 A/D Mode & Interrupt Control Read Back Register
- 30 Extended I/O Ports
- 30 Digital I/O register
- 31 D/A Output Register
- 31 Timer/Counter Register
- 32 A/D Conversion
- 33 A/D Conversion Procedure
- 33 A/D Signal Source Control
- 35 A/D Trigger Source Control
- 36 A/D Data Transfer Modes
- 38 Pre-Trigger Control
- 40 A/D Data Format
- 41 Interrupt Control
- 41 System Architecture
- 41 IRQ Level Setting
- 41 Dual Interrupt System
- 42 Interrupt Source Control
- 42 Extended Digital I/O Port
- 43 D/A Conversion
- 44 Digital Input and Output
- 44 Timer/Counter Operation
- 44 Introduction
- 45 Pacer Trigger Source
- 45 Pre-Trigger Counter
- 45 I/O Address
- 46 Libraries Installation
- 47 Programming Guide
- 47 Naming Convention
- 47 Data Types
- 48 _9111_Initial
- 48 _9111_DO
- 49 _9111_DO_Channel
- 49 _9111_DI
- 50 _9111_DI_Channel
- 50 _9111_EDI
- 51 _9111_EDO
- 51 _9111_EDO_Read_Back
- 52 _9111_Set_EDO_Function
- 53 _9111_DA
- 53 _9111_AD_Read_Data
- 54 _9111_AD_Read_Data_Repeat
- 54 _9111_AD_Set_Channel
- 55 _9111_AD_Get_Channel
- 56 _9111_AD_Set_Range
- 57 _9111_AD_Get_Range
- 57 _9111_AD_Get_Status
- 58 _9111_AD_Set_Mode
- 59 _9111_AD_Get_Mode
- 59 _9111_INT_Set_Reg
- 60 _9111_INT_Get_Reg
- 60 _9111_Reset_FIFO
- 61 _9111_AD_Soft_Trigger
- 61 _9111_Set
- 62 _9111_Get
- 62 _9111_AD_Timer
- 63 _9111_Counter_Start
- 63 _9111_Counter_Read
- 64 _9111_Counter_Stop
- 65 _9111_INT_Source_Control
- 66 _9111_CLR_IRQ
- 66 _9111_Get_IRQ_Channel
- 67 _9111_Get_IRQ_Status
- 67 _9111_AD_FFHF_Polling
- 68 _9111_AD_Aquire
- 68 _9111_AD_HR_Aquire
- 69 _9111_AD_INT_Start
- 70 _9111_AD_FFHF_INT_Start
- 72 _9111_AD_INT_Status
- 72 _9111_AD_FFHF_INT_Status
- 73 _9111_AD_FFHF_INT_Restart
- 74 _9111_AD_INT_Stop
- 75 What do you need
- 76 VR Assignment
- 76 A/D Adjustment
- 77 D/A Adjustment
- 77 Unipolar Analog Output
- 77 Bipolar Analog Output
- 78 9111util
- 78 Running 9111util.exe
- 79 System Configuration
- 80 Calibration
- 81 Functional Testing
- 82 I_EEPROM