C/C++ (Windows 95)

U16 W_9111_AD_FFHF_INT_Status (U16 cardNo, U16 *status, U16

*blockNo)

Visual Basic (Windows 95)

W_9111_AD_FFHF_INT_Status (ByVal cardNo As Integer, status As

Integer, blockNo As Integer) As Integer

@ Argument cardNo: status: blockNo: the card number of PCI-9111 card initialized. the status of the INT data transfer. The valid status code are the following:

AD_FFHF_INT_RUN

AD_FFHF_BLOCK_FULL the A/D conversion block number performed currently

@ Return Code

ERR_NoError

5.43 _9111_AD_FFHF_INT_Restart

@ Description

After calling _9111_AD_FFHF_INT_Start, the AD conversion and transfer won’t stop until the N blocks of conversion have been completed. After the

N blocks of AD data are acquired, calling this function can restart the

FIFO half full interrupt transfer without re-initial all the relative registers.

However, if _9111_AD_INT_Stop has been called, the program should use _9111_AD_FFHF_INT_Start to restart interrupt transfer function.

@ Syntax

C/C++ (DOS)

U16 _9111_AD_FFHF_INT_Restart (U16 cardNo)

C/C++ (Windows 95)

U16 W_9111_AD_FFHF_INT_Restart (U16 cardNo)

Visual Basic (Windows 95)

W_9111_AD_FFHF_INT_Restart (ByVal cardNo As Integer) As

Integer

@ Argument cardNo: the card number of PCI-9111 card initialized.

@ Return Code

ERR_NoError