9.6. Load & Energy Event. Entec ETMFC610

Add to My manuals
372 Pages

advertisement

9.6. Load & Energy Event. Entec ETMFC610 | Manualzz

Multi-Function Control ETMFC610

Storage Capacity

http://www.entecene.co.kr

Stores last 2,000 events.

*. NOTE ) The maximum number of events to be stored can be increased according to user requests.

9.6. Load & Energy Event

ETMFC610 has the function of periodically recording the load and energy measurement data. The user can configure the data field to record in the Load & Energy event. For the data field configuration method, please refer to “9.6.4. Load & Energy Field Configuration” .

Load & Energy events are recorded in three ways: minute average, maximum value per hour, and maximum value per day. However, if the ‘L&E Record’ setting in the "“MAIN MENU/

GENERAL/ EVENT RECORDER” menu is OFF, Load & Energy events will not be recorded.

9.6.1. Load & Energy/Min. Event

Average load and energy value is recorded every a period set on “GLOBAL SETTING / GENERAL/

EVENT RECORDER / L&P Interval” . Maximum 8,640 values, it’s about 90 days events can be recorded based on 15 minutes(default) for the event register period.

To check the average value per minute Load & Energy events, please move to “MAIN MENU /

EVENT / LOAD&ENERGY/MIN” .

*. NOTE ) Configuration display for Load&Energy/min events may be revised on user’s request.

EN HANCED TEC HNOLOGY 314

Multi-Function Control ETMFC610 http://www.entecene.co.kr

[▼][▲] button is used to check the events. To check real active power and reactive power, press

[ENT] button. To return back to previous screen, press [ENT] again. [0001/8640] is the latest event record.

Trigger Source

 Demand Current – A, B, C, G

 Demand Voltage – A, B, C, R, S, T

 Demand Active Power - A, B, C, 3 ф

 Demand Reactive Power – A, B, C, 3 ф

 Demand Power Factor – A, B, C, 3 ф

 Demand Energy - Positive Watthour(3 ф ), Positive Varhour(3 ф )

Trigger Time

Monitors to change Trigger source status every period set on “ GLOBAL SETTING / EVENT

RECORDER / L&E Interval” .

Storage Capacity

Stores last 8,640 events.

*. NOTE ) The maximum number of events to be stored can be increased according to user requests.

EN HANCED TEC HNOLOGY 315

advertisement

Key Features

  • Comprehensive metering and recording capabilities
  • Advanced protection functions for over/under voltage, over/under frequency, over/under current, and more
  • Flexible communication options including RS-485, Ethernet, and Modbus
  • User-friendly interface with a large LCD display and intuitive navigation
  • Compact and rugged design suitable for harsh environments
  • Versatile control capabilities for load shedding, generator control, and more
  • Advanced monitoring functions for voltage, current, power, and energy consumption

Related manuals

Frequently Answers and Questions

What are the input and output capabilities of the ETMFC610?
The ETMFC610 has 4 voltage inputs, 3 current inputs, 8 digital inputs, and 6 relay outputs.
What communication protocols does the ETMFC610 support?
The ETMFC610 supports Modbus RTU and Modbus TCP/IP protocols.
What is the accuracy of the ETMFC610's metering functions?
The ETMFC610's metering functions have an accuracy of 0.5% for voltage and current measurements, and 1% for power and energy measurements.
What is the maximum fault current that the ETMFC610 can withstand?
The ETMFC610 can withstand a maximum fault current of 20kA for 1 second.
What is the operating temperature range of the ETMFC610?
The ETMFC610 has an operating temperature range of -20°C to +70°C.