10.4. Data Reset. Entec ETMFC610

Add to My manuals
372 Pages

advertisement

10.4. Data Reset. Entec ETMFC610 | Manualzz

Multi-Function Control ETMFC610

10.4. Data Reset

http://www.entecene.co.kr

Move to “MAINTENANCE / DATA RESET” . This menu resets COUNT and Maintenance data.

Passcode 3 certification is required to enter “CLEAR SAED DATA” menu.

MAINTENACE / DATA RESET

[DATA RESET]

>1.ETMFC610 COUNT

2.OPERATION COUNT

3.FAULT COUNT

4.PQM COUNT

5.COM’ COUNT

6.COUNT ALL

7.INTERRUPT TIME

> 8.BATT. CAPACITY

9.CONTACT WEAR

10.ENERGY

11.MAX DEMAND

12.PEAK CURRENT

13.COMM BUFF

14.USER COUNT

15.ABOVE ALL

[CLEAR EVENT]

EVENT CLEAR SUCCESS

Saved Data Reset

Select an item to delete and press [ENT] button.

If deleting is completed, “EVENT CLEAR SUCCESS” message is displayed.

*. NOTE )

1.

‘OPERATION COUNT’ is reset by a set value in “MAIN

MENU/ GLOBLA SETTING/ MONITERING/ OPERATION

COUNT” .

2.

‘CONTACT WEAR’ is reset by a set value in “MAIN MENU/

GLOBLA SETTING/ MONITERING/ CONTACT WEAR” .

3.

‘BATT. CATPACITY’ is reset by a set value in “MAIN MENU/

GLOBLA SETTING/

MANAGEMENT” .

MONITERING/ BATT

4.

Except ‘OPERATION COUNT’ , ‘CONTACT WEAR’ and

‘BATT CATPACITY’ , all data is reset for 0.

15. ABOVE ALL

All count data of 1 ~ 14 menus are reset at once.

10.5. Controller Information

Move to “MAINTENANCE / CCU INFO” to confirm ETMFC610 controller information.

In this menu, information such as option, version and serial number of current ETMFC610 is displayed.

EN HANCED TEC HNOLOGY 334

advertisement

Key Features

  • Comprehensive metering and recording capabilities
  • Advanced protection functions for over/under voltage, over/under frequency, over/under current, and more
  • Flexible communication options including RS-485, Ethernet, and Modbus
  • User-friendly interface with a large LCD display and intuitive navigation
  • Compact and rugged design suitable for harsh environments
  • Versatile control capabilities for load shedding, generator control, and more
  • Advanced monitoring functions for voltage, current, power, and energy consumption

Related manuals

Frequently Answers and Questions

What are the input and output capabilities of the ETMFC610?
The ETMFC610 has 4 voltage inputs, 3 current inputs, 8 digital inputs, and 6 relay outputs.
What communication protocols does the ETMFC610 support?
The ETMFC610 supports Modbus RTU and Modbus TCP/IP protocols.
What is the accuracy of the ETMFC610's metering functions?
The ETMFC610's metering functions have an accuracy of 0.5% for voltage and current measurements, and 1% for power and energy measurements.
What is the maximum fault current that the ETMFC610 can withstand?
The ETMFC610 can withstand a maximum fault current of 20kA for 1 second.
What is the operating temperature range of the ETMFC610?
The ETMFC610 has an operating temperature range of -20°C to +70°C.

advertisement

Table of contents