2.7.4 Wiring a Relay Contact. Advantech EKI-7710G-2CI, EKI-7710E-2C, EKI-7710G-2CPI, EKI-7710G-2CP

Add to My manuals
156 Pages

advertisement

2.7.4 Wiring a Relay Contact. Advantech EKI-7710G-2CI, EKI-7710E-2C, EKI-7710G-2CPI, EKI-7710G-2CP | Manualzz

Electromagnetic Interference (EMI) affects the transmission performance of a device.

By properly grounding the device to earth ground through a drain wire, you can setup the best possible noise immunity and emissions.

Connection to

Grounding Point

Drain Wire with Lug

Figure 2.16 Grounding Connection

By connecting the ground terminal by drain wire to earth ground the switch and chassis can be ground.

Note!

Before applying power to the grounded switch, it is advisable to use a volt meter to ensure there is no voltage difference between the power supply’s negative output terminal and the grounding point on the switch.

2.7.4

Wiring a Relay Contact

The following section details the wiring of the relay output. The terminal block on the

EKI-7710 Series is wired and then installed onto the terminal receptor located on the

EKI-7710 Series.

V2+V2V1+V1DC12-48V

1A@24V

PWR2 P-Fail PWR1

Figure 2.17 Terminal Receptor: Relay Contact for Non PoE models

V2+V2V1+V1DC24-48V

1A@24V

PWR2 P-Fail PWR1

Figure 2.18 Terminal Receptor: Relay Contact for PoE models

The terminal receptor includes a total of six pins: two for PWR1, two for PWR2 and two for a fault circuit.

EKI-7710 Series User Manual 23