4.10.2 Ping Test. Advantech EKI-7710G-2CI, EKI-7710E-2C, EKI-7710G-2CPI, EKI-7710G-2CP

Add to My manuals
156 Pages

advertisement

4.10.2 Ping Test. Advantech EKI-7710G-2CI, EKI-7710E-2C, EKI-7710G-2CPI, EKI-7710G-2CP | Manualzz

The following table describes the items in the previous figure.

Item Description

Port

Copper Test

Click the drop-down menu to select a pre-defined port for diagnostic testing. Giga ports are displayed with a channel A to D designation.

Click

Copper Test

to display the test result for the selected port.

The ensuing table for

Test Result

settings are informational only: Port, Channel A,

Cable Length A, Channel B, Cable Length B, Channel C, Cable Length C, Channel D and Cable Length D.

4.10.2

Ping Test

The Ping Test page allows you to configure the test log page.

To access this page, click

Diagnostics

>

Ping Test

.

Figure 4.108 Diagnostics > Ping Test

The following table describes the items in the previous figure.

Item

IP Address

Count

Interval (in sec)

Description

Enter the IP address or host name of the station to ping. The initial value is blank. The IP Address or host name you enter is not retained across a power cycle. Host names are composed of series of labels concatenated with periods. Each label must be between 1 and 63 characters long, maximum of 64 characters.

Enter the number of echo requests to send. The default value is 4.

The value ranges from 1 to 5. The count entered is not retained across a power cycle.

Enter the interval between ping packets in seconds. The default value is 1. The value ranges from 1 to 5. The interval entered is not retained across a power cycle.

108 EKI-7710 Series User Manual