Removable Terminal Block (RTB). Beijer Electronics NA-9379
Add to My manuals35 Pages
Beijer Electronics NA-9379, a programmable I/O (PIO) device, offers a versatile solution for building custom control systems tailored to your specific needs. This compact and powerful module enables you to combine CODESYS control with the flexibility to design I/O signal configurations that precisely match your application requirements. Get ready to experience the benefits of a scalable and reliable control system with the NA-9379.
advertisement
![Removable Terminal Block (RTB). Beijer Electronics NA-9379 | Manualzz Removable Terminal Block (RTB). Beijer Electronics NA-9379 | Manualzz](http://s2.manualzz.com/store/data/066718013_1-2c3d3ee95bd81983e25c0be1e06b7fe3-360x466.png)
Programmable I/O (PIO) NA-9379, Basic setting
KI00341 2014-10
12.7
Removable Terminal Block (RTB)
12.8
Method of Wiring
Connecting or removing the cable by pushing the terminal button for the relevant points.
NOTE!
The use of an incorrect supply voltage or frequency can cause severe damage to the component.
12.9
Program Memory
Memory Size Function
Program Memory
Data Memory
512 KBytes PLC program (CODESYS)
Data register, Counter, Timer, Auxiliary Relay (memory cell)
512 KBytes Retain Time : 6 days
%IW0~%IW639 (640 word Input and Internal memory)
%QW0~%QW639 (640 word Output and Internal memory)
%MW0~%MW639 (640 word Internal memory)
Non-Volatile Memory 32 KBytes Retain Time : 6 days
Register (16bit): 16 KBytes, Flag (1 bit): 16 KBytes
Battery backup / persistent variables
- 8000 points: Data register/Counter/Timer (16 bit)
- 128 000* points: Auxiliary Relay (memory cell) (1 bit)
*)16k bytes => 16*8bit =128 000
12.10
Boot application
PIO do not use “Boot Application” file to restore the application after a power off/on. www.beijer.se
32 (35)
advertisement
Related manuals
advertisement
Table of contents
- 1 Function and area of use
- 1 About this Start Up document
- 2 First step!
- 3 Table of Contents
- 4 Specification
- 4 Interface, PIO (NA-9379)
- 5 LED Indicator
- 7 Setup IP address in PIO
- 7 IP setting (default)
- 7 Set the IP with BootP server
- 9 Configuration of CODESYS
- 9 Add PIO (NA-9379) to CODESYS
- 11 Configuration of PIO in CODESYS
- 11 Programming and configuration
- 12 How to add a POU
- 13 How to add a Task
- 13 How to add a POU to a Task
- 14 PLC setting
- 15 Select I/O module
- 16 Setting Device Parameter and I/O Mapping
- 17 Program example
- 17 New project
- 17 Add Global Variable and Persistent Variables
- 19 I/O Mapping
- 20 Write program in “PLC_PRG
- 21 Transfer CODESYS project to PIO
- 23 Monitor
- 24 Project backup
- 24 CODESYS, Create backup files
- 24 CODESYS, Project Archive
- 25 Persistent variables (32 kbyte)
- 26 Appendix
- 26 Environment specification
- 27 Interface Specification
- 29 Wiring diagram, PIO
- 31 Dimension
- 31 Expansion
- 31 Inserting and Removing the Module
- 32 Removable Terminal Block (RTB)
- 32 Method of Wiring
- 32 Program Memory
- 32 Boot application
- 33 Check Compiler, PIO and Library version
- 34 Trouble Shooting