7.2. IMPORTANT SAFETY INFORMATION

Please pay particular attention to the following points if hazardous voltages (>48V) are to be connected to either of the control outputs:

The circuits that the relay contacts are connected to must be of the same type, i.e. Both mains or both low voltage. It is not permissible to mix the types of circuit connected to these relays.

These products are Class II Equipment, meaning that they are designed with double insulation to protect against electric shock hazards. They must be installed in strict accordance with these instructions. It is the installer’s responsibility to ensure that any live or hazardous conductors are properly connected, not accessible to users, and that the equipment is left in a safe condition.

It is acceptable to connect mains circuits in the frequency range 45 to 65

Hz to these relays.

For currents up to 3 Amps, the minimum conductor cross sectional area must be 0.75 mm 2 (19awg) for flexible cords, or 1mm 2 (18awg) for other cables.

Circuits connected to these relays must be protected against overcurrent and short circuit by a suitable method, for example a fuse or circuit breaker rated at less than or equal to the relay contact rating.

The use of an isolated supply or an RCD is recommended for these circuits.

Cables must be correctly rated and specified for the intended environment, and of indoor or outdoor type as appropriate.

Always use the GAI-Tronics rear enclosure, installed according to these instructions.

7.3. Installation

1. To prepare for installation, open the door (where fitted), then undo the four retaining screws to remove the faceplate from the rear enclosure. A

3mm Allen key is required.

Caution

– take care to support the spring-loaded door whilst open to prevent it slamming shut and trapping fingers.

2. The Titan telephone is intended for vertical installation to a wall or pole.

Select the required mounting method (section 6) and mount the rear

enclosure first where applicable.

3. Route the required cables through glands as appropriate, and make connections following section 7.4. When fitting mains wiring to this product that is not wholly run within trunking, it is important that the strain relief is correctly installed and tested to ensure there will be no

VoIP Titan Illuminated Crossing Telephone.