Note that the area for printing is 81mm x 66mm and allows a border and a tab for ease of fitting.

8.2. Fitting the legend panel.

To fit the legend panel, first ensure that a panel has been correctly printed and cut to size according to the template above.

Remove the faceplate from the telephone by removing the 4 retaining screws.

Locate the slot behind the window, at the left hand edge when viewing from the front. The slot is only approximately 1mm thick, and there is a retaining guide to keep the legend panel aligned correctly.

Gently slide the legend panel into place. Undue force should not be necessary. Note that the slot is fairly tight to the dimensions above to ensure correct alignment.

When fully inserted, the edge of the legend panel will protrude beyond the circuit board to the edge of the gasket, allowing a tab for ease of removal. It must not overlap the strip of gasket, otherwise the water seal will be compromised.