![Connections. GAI-Tronics VoIP Titan Illuminated Crossing Telephone (1193 ), Illuminated Crossing Phone VoIP Titan | Manualzz Connections. GAI-Tronics VoIP Titan Illuminated Crossing Telephone (1193 ), Illuminated Crossing Phone VoIP Titan | Manualzz](http://s1.manualzz.com/store/data/067548197_1-762cea1dffbd2d1103ab09e5abda7752-360x466.png)
disturbance to the wire terminations. As a minimum the cable must withstand a pull of 100N (approx 10kg force or 22.5lbf) without visible movement. If conduit is used, mains cables must be secured elsewhere.
4. Re-fit the faceplate ensuring a weatherproof seal
5. Test the operation of the telephone. Installation is now complete.
7.4. Connections
Make the appropriate connections as shown on the diagrams below.
OP2
OP1
0V 0V +
AUX
IP1 IP2 IP3 IP4
Connection to Output 1
Clamp (on secondary insulation)
Connection to Input 1
Connector Legend
AUX 24-48Vdc
Connection
Barrier
Cabling example showing connections to Input 1, Output 1 and aux. DC supply
Take particular note of the cable clamping arrangements
– all cables must be securely clamped in the clamps provided.
Clamp cables by bending tabs
Connection types and ratings:
•
LAN connection - RJ45 on Cat5 or Cat5e UTP cable
•
All other connections - 0.14mm² to 2.5mm² (26 to 14awg) for rigid/solid cables, 0.14mm² to 1.5mm² (26 to 16awg) for flexible/stranded cable.
Refer to safety information in section 7.2
Output 1 - rating 2A at 250Vac, 2A at 30Vdc
VoIP Titan Illuminated Crossing Telephone. 13
Output 2 - 3A at 250Vac, 1A at 24Vdc
(Note: for Output 1, a continuous current of 2A will cause a 22°C temperature rise to the PCB area close to the terminals after 10mins. This will not cause the telephone to malfunction, but it may result in this area becoming hot especially in high ambient temperatures. Avoid operating Output 1 at high currents in high temperatures. If the current is below 1A this temperature rise will be less than 5°C. Output 2 will not give any significant temperature rise up to its rated current of 3A)
External power supply - 24-48Vdc, 200mA
Control inputs - for connection to voltage free contacts only. Internal pull-up resistor source current = 300uA. These inputs form part of an ES1 circuit and precautions must be taken to prevent hazardous voltages being applied to these circuits
Output 2
Common
(for inputs)
AUX 24-48V DC
- +
Output 1
1 2 3 4
Inputs
Network
End view of Connectors
Inputs 1-3 are available to be connected as required.
NOTE: Input 4 is reserved for the LED panel failure alarm and is internally connected on the PCB. Do not connect input 4 to any external device.
14 VoIP Titan Illuminated Crossing Telephone.
advertisement
Related manuals
advertisement
Table of contents
- 3 Safety and Care Information
- 3 Features
- 4 At a Glance
- 6 Quick Start Guide
- 7 Operation / Testing
- 7 Illuminated Panel alert
- 7 Handset integrity alert
- 7 Mounting methods and dimensions
- 7 General
- 8 Wall mounting
- 10 Pole mounting
- 11 Connections and Installation
- 11 General
- 12 IMPORTANT SAFETY INFORMATION
- 12 Installation
- 13 Connections
- 15 Legend Panel
- 15 Legend panel dimensions
- 16 Fitting the legend panel
- 17 Cleaning
- 17 Normal Cleaning
- 17 Stainless Steel Push-buttons
- 17 Graffiti
- 17 Aftercare
- 18 Technical Specifications
- 21 CE Declaration