Configuring power management for the server. Fujitsu iRMC S4
Anúncio
Anúncio
Power Management
7.8.2
Power Options -
Configuring power management for the server
The Power Options page allows you to define the server’s behavior after a power outage and specify the server’s power on/off times.
Figure 118: Power Options page iRMC S4
203
Power Management
Power Restore Policy - Specify behavior of the server after a power outage
The Power Restore Policy group allows you to specify the server’s power management behavior after a power outage.
Figure 119: Power Options page, Power Restore Policy
Always power off
The server always remains powered down after a power outage.
Always power on
The server is always powered up again after a power outage.
Restore to powered state prior to power loss
The power up/down status of the server is restored to the status prior to the power outage.
Ê
Click Apply to activate your settings.
The configured action will be performed after a power outage.
204
iRMC
Power Management
Power On/Off Time - Specify power on/off times for the server
The input fields of the Power On/Off Time group allow you to specify the times at which the server is powered up/down for the individual days of the week or for specified times during the day.
I
Specifications in the Everyday field take priority!
The Trap fields also allow you to configure whether the iRMC sends an SNMP trap to the management console before a planned power-on / power-off of the managed server and, if so, how many minutes before the event this should be done. No traps are sent if you specify the value “0”.
Figure 120: Power Options page, Power On/Off Time iRMC S4