Installing Linux on the managed server after configuration. Fujitsu iRMC S4
Iklan
Iklan
Installing the operating system
11.4.2 Installing Linux on the managed server after configuration
I
The mouse can be used but not synchronized during Linux installation.
I
Whenever you change a virtual storage medium, you must remove the virtual media connection for the currently connected medium and then connect the new medium as a virtual storage medium.
After configuration has been completed, the Installation Manager displays the following dialog page:
Figure 259: Installation Manager - Installation Info
If you have configured the local CD ROM/DVD ROM drive of the managed server as the installation source, proceed as follows at the remote workstation:
Ê Clear your currently active virtual media connections. For more detailed
information on clearing virtual media connections, see page 119 .
Ê
Remove ServerView Suite DVD 1 from the
DVD ROM drive at the remote workstation.
iRMC S4
423
Installing the operating system
Ê Insert the Linux installation CD/DVD in this DVD ROM drive.
I
Close the application if autostart is active.
Ê
Connect the CD ROM/DVD ROM drive containing the Linux installation
CD/DVD as virtual storage medium.
Ê In the Installation Info page of the Installation Manager, click Start installation.
All the installation files are copied to the managed server. The Installation
Manager opens a confirmation dialog page when the copy operation is complete and prompts you to remove all the storage media from the removable media drives before the managed server is rebooted.
I
Before rebooting the system, you must in particular shut down all current virtual media connections.
Ê Before rebooting the system, shut down the current virtual media connections.
To do this, proceed as follows:
Ê
Start “Virtual Media” (see
The Virtual Media dialog box is displayed with the currently connected virtual media devices.
Ê
Click all Disconnect buttons to remove all the virtual media connections.
Ê
“Safely remove” the storage device, i.e. ensure that no more applications/programs are accessing the storage media.
Ê On the confirmation dialog page, click Ok to reboot the managed server.
Once the managed server has rebooted, you can monitor the entire installation by means of the AVR.
424
iRMC
Unduh
Iklan