Description of Parts and Settings
Note
Section 2-1
On unpacking the NT20 and peripheral devices, check their external appearance and confirm that there is no damage. Also confirm that there is no abnormal noise when you shake the PT lightly.
2-1 Description of Parts and Settings
Before getting to the operation, confirm the names and functions of parts.
Also set the DIP switches on the NT20.
2-1-1 Description of Parts
Front View
Rear View
Note
RUN indicator
• Lit green while the PT is in
RUN mode.
Touch switches can be created in the desired locations on the display and used as lamps, input switches, and other functional objects.
The NT20 comes in two body colors.
• NT20-ST121-E: Ivory
• NT20-ST121B-E: Black
• NT20-ST128: Ivory
• NT20-ST128B: Black
Expansion interface connector
When using an Expansion Interface Unit such as a Memory Unit, connect it here.
Battery cover
There is a battery holder beneath this cover. The Battery is not installed when the
PT is shipped.
Type name
Contrast control
Use a fine flat-blade screwdriver.
Reset switch
DIP switch
Power input terminals
Connect the power to the NT20 at these terminals
Serial port B connector
Connect this connector to communicate with a host. An RS-232C 9-pin connector is required. A
CJ1W-CIF11 RS-422A Converter can be connected directly.
Serial port A connector
Connect this connector to a host or to a computer running Support Software.
An RS-232C 9-pin connector is required. A CJ1W-CIF11 RS-422A
Converter can be connected directly.
18
Description of Parts and Settings
Section 2-1
2-1-2 Operation Status DIP Switch Settings
Set the NT20 operation status with the DIP switches located in the bottom right corner on the rear of the body.
Switch #
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
Function
Screen data forced initialize effective/ineffective
Note When this switch is ON, SW2-4, SW2-5 and SW2-6 must be OFF.
ON The NT20 will start in a special RUN mode in which the screen data memory is initialized. When it is started, the memory initialization menu will be displayed. For the initialization procedure, refer to
Section 3-4 Initializing Memory.
[OFF] The NT20 will start in normal RUN mode.
Screen display language mode. DIP SW2-2 is used to indicate language selection. If it is turned ON, then display language will use English and the language parameter in memory SW is not selectable (User can't choose other language than English.) But if it is turned OFF, then user can choose other language through language parameter in memory SW.
[ON]
OFF
Messages are displayed in English.
Language can be selected.
Switching to the System Menu enabled/disabled
ON The System Menu cannot be displayed. If an error occurs during a start-up, the System Menu will be automatically displayed. However, “transfer mode” cannot be entered.
[OFF] The System Menu can be displayed.
Unused (Reserved for system use)
System resource initialize
Note When this switch is ON, SW2-1, SW2-4 and SW2-6 must be OFF.
ON Effective
[OFF] Invalid
System program initialize
Note When this switch is ON, SW2-1, SW2-4 and SW2-5 must be OFF.
ON Effective
[OFF] Invalid
[ ] indicates factory setting.
!Caution If the DIP switch settings have been changed when the NT20 is powered, reset the power to the NT20. The changes with the DIP switches become effective only after the power supply is reset.
Note
(1) ln addition to the DIP switches, set also the “communications type”, “host link baud rate”, etc. at the memory switches when host link/NT link is used.
For these settings, refer to Section 3-5 Setting the Conditions of Commu-
nications with the Host by Using the Memory Switches (page 91).
(2) It may be necessary to change the DIP switch settings after installing the
NT20 in an operation panel. Bear this in mind when deciding the installa-
19
Description of Parts and Settings
Section 2-1
tion position.
During work at the panel, take care to ensure that no metal scraps enter the unit.