Below you will find brief information for Programmable Terminal NT NT20, Programmable Terminal NT NT20S, Programmable Terminal NT NT20M. The NT20 is a programmable terminal used to display and transmit information in an FA site. It can be easily installed and used. NT20, NT20S and NT20M support features and functionality to display, receive data from a host and send data to a host. It also gives the operation examples and characteristics of the NT20.
Advertisement
Advertisement
Maintenance of the NT20
Section 7-3
7-3 Maintenance of the NT20
Carry out maintenance work in order to ensure that the NT20 is always used in its optimum condition.
Spare PT
Backlight
!WARNING
Do not attempt to take the PLC apart and do not touch any internal parts while the power is being supplied. Doing either of these may result in electrical shock.
It is advisable to have a spare NT20 available to minimize system downtime in the event of an NT20 failure or if the screen display becomes difficult to read due to deterioration of the display unit.
The backlight must be replaced when the brightness of the display backlight dims and the display becomes difficult to see. The backlight cannot be replaced by the user.
Contact your nearest OMRON representative.
7-4 Inspection and Cleaning
Clean and inspect the NT20 regularly to ensure that it is always used in its optimum condition.
Cleaning Method
Inspection Method
Note
If the display is dirty the screen is difficult to see. Clean the screen from time to time as follows.
• In daily cleaning, wipe the display with a soft dry cloth.
• If the soiling cannot be removed with a dry cloth, wet the cloth with water, wring it out well and wipe the display with it.
• If rubber or vinyl products, tape, etc. are left stuck to the display for long periods they will cause staining. If such items are stuck to the display, remove them during cleaning.
Never use volatile solvents such as benzene or thinners, or dusters.
In normal environments, inspect the NT20 at intervals of between 6 months and a year. In environments that are extremely hot and humid, or very dusty environments, shorten the inspection interval.
• Items Required for Inspection
Prepare the following items before starting the inspection.
• The tools supplied with the NT20
• Screwdrivers (Phillips, flat-head)
• Tester (or digital voltmeter)
• Industrial alcohol
• 100% cotton cloth
• Hygrometer (required in some cases)
• Thermometer (required in some cases)
• Synchroscope (required in some cases)
• Pen-writing oscilloscope (required in some cases)
253
Inspection and Cleaning
Section 7-4
• Faulty Display Pixels
Although the LCD panel has been manufactured with extremely high-level technology, there can sometimes be pixels that will not light or that will be lit constantly. These are characteristic of LCD panels and are not an indication of a faulty display. Please understand that, although we are constantly striving to keep these pixels to a minimum, it is not possible with present technology to eliminate them completely.
• Points Inspected
Inspect the following points to determine if there is any divergence from the stated criteria. If there is, either improve the surrounding environment so that the values fall within the stated range, or adjust the NT20.
Point Inspected Inspection Details
Power supply voltage Fluctuation in power supply terminal voltage
Criterion
Permissible voltage fluctuation range (24 VDC
−
15% +15%)
0 to 50
°C
Inspection Instrument
Tester
Ambient environmental conditions
Ambient temperature (temperature in the operation panel)
Thermometer
Ambient humidity
(humidity in the operation panel)
Presence/absence of dust
35% to 85% Hygrometer
Mounting conditions Looseness of mounting brackets etc.
Looseness of screws in external wiring
Conditions of external connecting cables
Dust must not be settled Visual inspection
To be no looseness
Connector connections of connecting cable To be fully inserted and locked, with no looseness
To be no looseness
Faults such as incipient disconnections.
Accessory tools
Phillips screwdriver
Visual inspection
External appearance Peeling of front sheet Front sheet must not show any signs of peeling.
Visual inspection
Note
(1) Do not attempt to disassemble the NT20 for repair or modification.
(2) The disposal of the NT20 may be regulated by national or local authorities. Dispose of them according to the laws and regulations of the relevant country and local authority.
(3) When replacing the NT20 after discovering a fault during inspections, note the following points:
• Be sure to switch the power OFF before replacement.
• After replacement, check that the new NT20 is not subject to the same error.
• If a faulty unit is returned for repairs, write as detailed a description of the fault as possible and send this description together with the unit to the OMRON address indicated on the back cover of this book.
254
Appendix A
Specifications
General Specifications
Item
Power supply voltage
Allowable power supply voltage range
Allowable momentary power interruption time
Power consumption
Ambient operating temperature
Storage temperature
Ambient operating humidity
Ambient storage humidity
Operating environment
Noise immunity
Vibration resistance (during operation)
Shock resistance (during operation)
Dimensions (mm)
Panel cutout dimensions
Weight
Degree of protection
Applicable standards
Specification
24 VDC
20.4 VDC to 27.6 VDC (24 VDC –15% +15%)
Not specified.
10 W max.
0 to 50
°C (with no freezing)
–20 to 70
°C
35% to 85% at 0 to 40
°C (with no condensation)
35% to 50% at 40 to 50
°C (with no condensation)
35% to 85% at
−20 to 40°C (with no condensation)
35% to 50% at 40 to 50
°C (with no condensation)
35% to 45% at 50 to 70
°C (with no condensation)
No corrosive gases.
Based on IEC 61000-4-4: 2 kV (power line)
5 to 9 Hz with 3.5-mm single amplitude, 9 to 150 Hz with 9.8-m/s
2
acceleration for 10 times (1 octave/min) in each of X, Y and Z directions
147 m/s
2
, 3 times in each of X, Y and Z directions
190 x 108 x 53.5 mm (W x H x D)
178.5
+0.5
/
0
x 98.5
+0.5
/
0
mm (H x V), Panel thickness: 1.6 to 4.8 mm
0.7 kg max.
Front panel operating section: Equivalent to oil-resistant IP65 and equivalent to NEMA4 (See note 2.)
UL 1604 Class 1 Division 2 and EC Directives
Note
(1) The display quality (e.g., the contrast) will deteriorate at temperatures above 40
°C. Also, response will be slower due to the characteristics of liquid crystals at low temperatures.
(2) Do not use the PT in locations subject to long-term exposure to oil.
255
Specifications
Appendix A
Performance Specifications
Display Specifications
Item
Display panel
(See note 1.)
Backlight
(white cold cathode tube)
Front-panel indicator
Specification
Display device
Number of dots
(resolution)
Monochrome STN LCD (with backlight)
140 (128) vertical
× 260 (256) horizontal, dot size: 0.42 mm
Values in parentheses are the numbers of dots that can be used by the NT20 system program.
Effective display area 66 (57.6) mm vertical
× 120 (115.2) mm horizontal
Values in parentheses are effective display area that can be used by the NT20 system program.
Display mode
View angle
Life expectancy
Blue mode
Up: 40
°, Down: 50°, Left: 35°, Right: 35°
50,000 hours minimum
Contrast adjustment The contrast can be adjusted with the contrast adjustment on the back of NT20.
Life expectancy
Replacement
50,000 hours minimum (See note 2.)
User must not replace the backlight.
Brightness adjustment Not provided.
Automatic turn-off Can be set to turn off in 10 minutes, 1 hour, or to remain ON.
RUN Lit green: Running normally and Memory Unit automatic transmission completed.
Flashing green: Memory Unit automatic transmission being executed or Memory
Unit automatic transmission error.
Note
(1) There are sometimes faulty pixels in the touch panel but this does not indicate an error as long as the number of bright or dark pixels does not exceed the following limits.
4 total defects max. of the following size with no more than one per 20-mm square:
0.2 mm < (short dia. + long dia.)/2
≤ 0.55 mm
(2) Time taken for brightness to reduce to half at room temperature and humidity. This is a reference value only. The life expectancy will be radically reduced at low temperatures. For example, the life expectancy at 0
°C or lower will be 10,000 hours (reference value).
Panel Specifications
Item
Touch panel
Specification
Number of switches: 72 (6 vertically
× 12 horizontally)
Switch size: 9.14 mm horizontal
× 9.18 mm vertical
Input: Pressure-sensitive type
Life expectancy: 1 million operations min.
256
Specifications
Appendix A
Display Capacity
Display elements
Item
Character displays
Character string displays
Specification
Host Link/NT Link
C200H direct communications
RS-232C (NT20-ST128)
Fixed character data (character strings registered for each screen)
32 positions per screen 128 strings per file, 32 positions per screen
Screen types
Screen attributes
Numeral displays
(See note.)
Graph displays
(See note.)
Graphic displays
Lamps
Continuous screens
50 positions per screen, 8-digit display
50 per screen
Can be displayed wherever required.
128 per screen 256 strings per file max.
Touch switches
Numeral settings
(See note.)
Normal screen
72 per screen 256 strings per file max.
Display of set numerical values 50 per screen, 8 digits each
Displays screens registered as normal.
Overlapping screens A maximum of 8 registered screens can be displayed overlapped with each other.
A maximum of 8 screens can be displayed sequentially by scrolling.
(The screen can be changed by pressing the and touch switches)
Buzzer, numeral setting, backlight Buzzer, numeral setting, backlight, bit input
Max. number of registered screens
Screen registration method
Screen saving method
(screen data memory)
495
Transfer screen data created using the Support Tool to the PT.
Saved to flash memory (recording format unique to NT20)
Note Number of numeral memory table entries that can be set (number used for numeral display + number used for graphs + number used for numeral settings)
≤ 128
Display Element Specifications
Display characters
Item
Enlargement function
Smoothing processing
Character display attributes
Graphics
Specification
Half-size characters (8
× 8 dots): Alphanumerics and symbols
Normal characters (8
× 16 dots): Alphanumerics and symbols
Marks (16
× 16 dots): User-defined pictographs
Horizontal and vertical magnifications of double width, double height, 4x, 9x, and 16x
Enlarged characters up to 4x
Normal, inverse, flashing, inverse flashing
Continuous straight lines, circles
Data Quantities
Item
Strings
Numeral data
Marks
Touch switches
Lamps
Specification
Host Link/NT Link
C200H direct communications
128 strings comprising 32 characters each
RS-232C (NT20-ST128)
128 max. (8 digits each)
64 marks
No maximum restriction
No maximum restriction
256 strings per file max.
256 strings per file max.
257
Specifications
Appendix A
Special Features
Buzzer
Item
Maintenance functions
Key input sound setting
Two types:
Setting:
Specification
Continuous sound and intermittent sound
Set “Buzzer Sound” in the “Memory Switch” menu of the
Maintenance Mode ON.
ON:
If “ERR ON” is set the buzzer only sounds when an error occurs.
The buzzer sounds on designation from the PLC, when a screen with a buzzer-ON specification is called, or on display of an error screen such as for a receive error.
OFF: The buzzer is turned off on designation from the PLC, by touch switch input, or when a screen without a buzzer-ON specification is displayed.
Sound pressure: Min. 80 dB, average 87 dB (measured 10 cm from front face)
• Self-test for memory, switches, etc.
• Status setting confirmation for communications and other conditions.
• Simple communications confirmation.
0.2 second input sound when a touch switch is pressed
Setting: Set “Key Sound” of the “Memory Switch” menu in the Maintenance mode ON.
Note The NT20 system program does not provide a battery backup function.
258
Specifications
Appendix A
Communications Specifications
Host Link
Item
Communications standard
Communications settings
Specification
EIA RS-232C
Start-stop synchronization
Baud rate: 9,600, 19,200, 38,400, 57,600, 115,200 bps
Data length: 7 bits
Stop bits:
Parity:
2 bits
Even
9-pin, D-SUB connector (female)
1 to 1
15 m max.
Connector
Number of units connected
Transmission distance
NT Link (1:1)
Item
Communications standard
Connector
Number of units connected
Transmission distance
NT Link (1:N)
Item
Communications standard
Connector
Number of units connected
Transmission distance
EIA RS-232C
9-pin D-SUB connector (female)
1 to 1
15 m max.
Specification
Specification
EIA RS-232C
9-pin D-SUB connector (female)
1:1 to 8
RS-232C cable: 2 m max. (*)
RS-422A/485 cable: Total length 500 m (*)
(*) When NT-AL001 used
RS-232C (NT20-ST128)
Item
Communications standard
Communications settings
Connector
Number of units connected
Transmission distance
Specification
EIA RS-232C
Start-stop synchronization
Baud rate: 2,400, 4,800, 9,600, 19,200 bps
Data length:
Stop bits:
7, 8 bits
1, 2 bits
Parity:
Flow control:
Even, Odd, None
RS/CS control
XON/XOFF control
None
9-pin D-SUB connector (female)
1 to 1
15 m max.
259
Specifications
Appendix A
260
Outside Dimensions
178.20
Appendix B
Dimensions
190
Installation Dimensions
178
RUN
4.50
53.50
Unit: mm
Installation panel
Mounting Bracket
142
190
16
5 37
Unit: mm
261
Dimensions
Cable Connection Dimensions
20
53
73
44
Unit: mm
Cable Connection Dimensions (with C200H Communications Interface Unit Mounted)
Installation panel
Mounting Bracket
99.4
12.1
Appendix B
19.5
52.5
(Unit: mm)
5.3
40.5
87.2
35.1 min.
39.3 max.
262
Appendix C
Transporting and Storing PTs
• Use the special packing box provided with the PT when shipping the PT.
• When storing the PT, store it under the following conditions:
Ambient storage temperature:
−20 to 70°C
Ambient storage humidity: 35% to 85% (
−20 to 40°C)
35% to 50% (40 to 50
°C)
35% to 45% (50 to 70
°C)
263
Transporting and Storing PTs
Appendix C
264
Appendix D
Making the Cable
The procedure for making up the cable is described below.
Also refer to this procedure for making a connecting cable for use with RS-422A/485 type connections.
Cable Preparation
The preparation of the cable differs according to whether or not the shielding wire is to be connected to the FG.
Cable with Shield Connected to FG
1.
Cut the cable to the required length.
2.
Remove the external vinyl insulation from the cable with a razor blade. Take care not to damage the shielding underneath.
3.
Cut back the shielding wire with scissors.
4.
Use wire strippers to strip the insulation from each wire.
5.
Fold back the shielding wire.
6.
Wrap aluminum foil tape around the folded-back shielding wire.
(1)
(2)
40 (1.57) (RS-232C)
25 (0.98) (RS-422A)
(3)
10
(0.39)
(4)
(5)
5
(0.19)
(6)
Units: mm (inch)
Aluminum foil tape
Cable with Shield Not Connected to FG
1.
Cut the cable to the required length.
2.
Remove the external vinyl insulation from the cable with a razor blade. Take care not to damage the shielding underneath.
3.
Cut back the shielding wire with scissors.
4.
Use wire strippers to strip the insulation from each wire.
265
Making the Cable
5.
Wrap vinyl tape over the cut off end of the shielding wire.
(1)
(2)
40 (1.57) (RS-232C)
25 (0.98) (RS-422A)
(3)
(4)
(5)
5
(0.19)
Units: mm (inch)
Soldering
1.
Slide heat-shrink tube over each wire.
2.
Pre-solder each wire and connector terminal.
3.
Solder each wire to each connector terminal.
Vinyl tape
Appendix D
1 mm
Soldering iron
Heat-shrink tube
(F, 1.5 mm dia., l = 10 mm)
4.
Push the heat shrink tube over the soldered joint and heat the tube to shrink it in place.
Heat-shrink tube
Hood Assembly
Assemble the connector hood as shown below.
End connected to FG
Aluminum foil tape
End not connected to FG
266
Appendix E
Making the Cable for Connecting a Personal
Computer
Refer to the following when making a cable for connecting the NT Support Tool.
Assembly of Connecting Cables
Wiring should be carried out in one of the following ways, depending on the type of RS-232C connector.
25-pin Connector
SD
RD
Personal computer
RS
CS
SG
FG
2
3
4
5
7
1 Shield
2
3
4
5
9
6
SD
RD
RS
Connector for peripheral devices on PT
CS
SG
+5 V
Connector hood Connector hood
Use the following recommended products when making the connecting cable.
Connector
Name
Connector hood
Connector set
Cable
Model
XM2D-2501
XM2A-0901
XM2S-2511
XM2S-0911
XM2S-0911-S003
AWG28
×5P IFVV-SB
CO-MA-VV-SB 5P
×28AWG
Remarks
25-pin, made by OMRON, for personal computer end
9-pin, made by OMRON, for PT end
25-pin, made by OMRON, for personal computer end
9-pin, made by OMRON, for PT end
9-pin, made by OMRON, for PT end
Connector and Connector hood
Multi-core shielded cable, made by Fujikura Ltd.
Multi-core shielded cable, made by Hitachi Cable, Ltd.
267
Making the Cable for Connecting a Personal Computer
9-pin Connector
Appendix E
RD
SD
Personal computer
RS
CS
7
8
5
2
3
4
5
9
2
3
SD
RD
RS
Connector for peripheral devices on PT
CS
SG
SG
Shield
6
+5 V
Connector hood
Connector hood
Use the following recommended products when making the connecting cable.
Connector
Name
Connector hood (See note.)
Connector set
Cable
Model
XM2D-0901
XM2A-0901
XM2S-0911
XM2S-0913
XM2S-0911-S003
AWG28
×5P IFVV-SB
CO-MA-VV-SB 5P
×28AWG
Remarks
9-pin, made by OMRON, for personal computer
9-pin, made by OMRON, for PT
9-pin, mm pitch screw, made by OMRON
9-pin, inch pitch screw, made by OMRON
9-pin, made by OMRON, for PT end
Connector and Connector hood
Multi-core shielded cable, made by Fujikura Ltd.
Multi-core shielded cable, made by Hitachi Cable, Ltd.
Note One XM2S-0911 (for PT) and either one XM2S-0911 or -0913 (for your personal computer) are needed.
268
Appendix F
Model List
PTs
Model
NT20-ST121-E
NT20-ST121B-E
NT20-ST128
NT20-ST128B
Host link/NT link/C200H
Host link/NT link/C200H
RS232C
RS232C
Specification
Japanese/English language support (Ivory)
Japanese/English language support (Black)
Japanese/English language support (Ivory)
Japanese/English language support (Black)
Host Link Units
Model
C120-LK201-V1
Specification
• Features a connector for RS-232C connections
• Type mounted to a CPU
C200H-LK201(-V1) • Features a connector for RS-232C connections
• Type mounted to C200H base
C500-LK201-V1
C500-LK203
Features a connector for RS-232C/RS-422A connections (switchable type).
Type mounted to C500 base
CV500-LK201 • Features a connector for RS-232C connections and a connector for
RS-232C/RS422A connections (switchable type).
• Type mounted to base for CVM1/CV use.
Applicable PLC
C-series
C120
C200H
C500(F)
C1000H
C2000(H)
C-series
C200H(S)/HE/HG/HX
C-series
C500(F)
C1000H
C2000(H)
CVM1/CV-series
CV500
CV1000
CV2000
CVM1
Communications Units
Model
CS1W-SCU21-V1
CS1W-SCU31-V1
CJ1W-SCU21-V1
CJ1W-SCU31-V1
CJ1W-SCU41-V1
Specification
RS-232C (2 ports)
Rack-mounting Unit
RS-422A/485 (2 ports)
Rack-mounting Unit
RS-232C (2 ports)
RS-422A/485 (2 ports)
Features an RS-422A/485 (port 1) and an RS-232C port (port 2)
Applicable PLC
CS-series
CS1G/H, CS1G/H-H
CJ-series
CJ1G, CJ1G/H-H
269
Model List
Appendix F
CPU Units (for Connection Via a Host Link)
Model
C20H/C28H/C40H/C60H
CPM1-10CDR@
CPM1-20CDR-
@
CPM1-30CDR@
CPM1A-10CDR
@-@
CPM1A-30CDR @-@
CPM1A-40CDR
@-@
CPM2A-30CD @@-@
CPM2A-40CD @@-@
CPM2A-60CD @@-@
CPM2C-10 @@@@@@-@ (See note 1.)
CPM2C-20
@@@@@@-@ (See note 1.)
CQM1-CPU21-E
CQM1-CPU41-E
CQM1-CPU42-E
CQM1-CPU43-E
CQM1-CPU44-E
CQM1H-CPU11 (See note 2.)
CQM1H-CPU21
CQM1H-CPU51
CQM1H-CPU61
C200HS-CPU21-E
C200HS-CPU23-E
C200HS-CPU31-E
C200HS-CPU33-E
C200HE-CPU32-(Z)E (
*
)
C200HE-CPU42-(Z)E
C200HG-CPU33-(Z)E (
*
)
C200HG-CPU43-(Z)E
C200HG-CPU53-(Z)E (
*
)
C200HG-CPU63-(Z)E
C200HX-CPU34-(Z)E (
*
)
C200HX-CPU44-(Z)E
C200HX-CPU54-(Z)E (
*
)
C200HX-CPU64-(Z)E
C200HX-CPU65-(Z)E
C200HX-CPU85-(Z)E
CV500-CPU01-EV1
CV1000-CPU01-EV1
CV2000-CPU01-EV1
CVM1-CPU01-EV1
CVM1-CPU11-EV1
CVM1-CPU21-EV1
Specification
Features a 9-pin connector for RS-232C connections
Connect an RS-232C adapter to the peripheral port.
Connect an RS-232C adapter to the peripheral port.
Connect an RS-232C adapter to the peripheral port.
Features a 9-pin connector for RS-232C connections.
Features a connector for RS-232C connections (selectable/9-pin).
Features a connector for RS-232C connections (selectable/9-pin)
Features a connector for RS-232C connections (selectable/9-pin).
Features a connector for RS-232C connections (selectable/9-pin).
Features a connector for RS-232C connections (selectable/9-pin).
PLC Type
C-series
C20H
C28H
C40H
C60H
C-series
CPM1
CPM1A
C-series
CPM2A
Connect an RS-232C adapter to the peripheral port. C-series
CPM2C
Features a 9-pin connector for RS-232C connections. C-series
CQM1
C-series
CQM1H
C200HS
C-series
C200HE
C-series
C200HG
C-series
C200HX
CVM1/CV-series
CV500
CV1000
CV2000
CVM1
270
Model List
Appendix F
Model
CS1G-CPU42-EV1
CS1G-CPU43-E1
CS1G-CPU44-EV
CS1G-CPU45-EV
CS1H-CPU63-EV1
CS1H-CPU64-EV1
CS1H-CPU65-EV1
CS1H-CPU66-EV1
CS1H-CPU67-EV1
CS1G-CPU42H
CS1G-CPU43H
CS1G-CPU44H
CS1G-CPU45H
CS1H-CPU63H
CS1H-CPU64H
CS1H-CPU65H
CS1H-CPU66H
CS1H-CPU67H
CJ1G-CPU44
CJ1G-CPU45
Specification
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
PLC Type
CS-series
CS1G
CS-series
CS1H
CS-series
CS1G-H
CS-series
CS1H-H
CS-series
CJ1G
Note For CPU units marked (*), a communications board is required.
1.Use a CPM2C-CN111 or CS1W-CN114/118 Connecting Cable, CPM1-CIF01 RS-232C Adapter, or
CPM1-CIF11 RS-422A Adapter to connect.
2.The CQM1H-CPU11 does not have a built-in RS-232C port, so connect to the PT at the peripheral port with a CS1W-CN118 Connecting Cable.
271
Model List
Appendix F
CPU Units (for Connection Via an NT Link (1:1))
Model
CPM1-10CDR@
CPM1-20CDR@
CPM1-30CDR@
CQM1-CPU41-E
CQM1-CPU42-E
CQM1-CPU43-E
CQM1-CPU44-E
CQM1H-CPU21-E (*)
CQM1H-CPU51-E
CQM1H-CPU61-E
CPM1A-10CD @-@
CPM1A-20CD
@-@
CPM1A-30CD @-@
CPM1A-40CD
@-@
CPM2A-30CD @@-@
CPM2A-40CD @@-@
CPM2A-60CD @@-@
CPM2C-10 @@@@@@-@ (See note 1.)
CPM2C-20
@@@@@@-@ (See note 1.)
C200HS-CPU21-E
C200HS-CPU23-E
C200HS-CPU31-E
C200HS-CPU33-E
C200HE-CPU32-E(*)
C200HE-CPU42-E
C200HG-CPU33-E(*)
C200HG-CPU43-E
C200HG-CPU53-E(*)
C200HG-CPU63-E
C200HX-CPU34-E(*)
C200HX-CPU44-E
C200HX-CPU54-E(*)
C200HX-CPU64-E
CV500-CPU01-V1-EV1
CV1000-CPU01-V1-EV1
CV2000-CPU01-V1-EV1
CV2000 CPU01 V1 EV1
CVM1-CPU01-V1-EV @
CVM1-CPU11-V1-EV @
CVM1-CPU21-EV @
Specification
Connect an RS-232C adapter to the peripheral port.
Features a 9-pin connector for RS-232C connections. C-series
CQM1
Features a 9-pin connector for RS-232C connections. C-series
CPM1H
Connect an RS-232C adapter to the peripheral port.
C-series
CPM1
C-series
CPM1A
Features a 9-pin connector for RS-232C connections. C-series
CPM2A
Connect an RS-232C adapter to the peripheral port.
C-series
CPM2C
Features a 9-pin connector for RS-232C connections. C200HS
Features a connector for RS-232C connections
(selectable/9-pin).
Features a connector for RS-232C connections
(selectable/9-pin).
Features a connector for RS-232C connections
(selectable/9-pin).
Features a 9-pin connector for RS-232C connections
C-series
C200HE
C-series
C200HG
C-series
C200HX
CV500
PLC Type
CV1000
CV2000
CVM1-series
Note For CPU units marked (*), a communications board is required.
1.Use a CPM2C-CN111 or CS1W-CN114/118 Connecting Cable, CPM1-CIF01 RS-232C Adapter, or
CPM1-CIF11 RS-422A Adapter to connect.
272
Model List
CPU Units (for Connection Via an NT Link (1:N))
Model
C200HE-CPU32-(Z)E(*)
C200HE-CPU42-(Z)E
C200HG-CPU33-(Z)E(*)
C200HG-CPU43-(Z)E
C200HG-CPU53-(Z)E(*)
C200HG-CPU63-(Z)E
C200HX-CPU34-(Z)E(*)
C200HX-CPU44-(Z)E
C200HX-CPU54-(Z)E(*)
C200HX-CPU64-(Z)E
C200HX-CPU65-(Z)E
C200HX-CPU85-(Z)E
CQM1H-CPU51 (*)
CQM1H-CPU61 (*)
CS1G-CPU42-EV1
CS1G-CPU43-EV1
CS1G-CPU44-EV1
CS1G-CPU45-EV1
CS1H-CPU63-EV1
CS1H-CPU64-EV1
CS1H-CPU65-EV1
CS1H-CPU66-EV1
CS1G-CPU42H
CS1G-CPU43H
CS1G-CPU44H
CS1G-CPU45H
CS1H-CPU63H
CS1H-CPU64H
CS1H-CPU65H
CS1H-CPU66H
CS1H-CPU67H
CJ1G-CPU44
CJ1G-CPU45
Specification
Features a connector for RS-232C connections
(selectable/9-pin).
Features a connector for RS-232C connections
(selectable/9-pin).
Features a connector for RS-232C connections
(selectable/9-pin).
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Note For CPU units marked (*), a communications board is required.
Appendix F
PLC Type
C-series
C200HE-(Z)E
C-series
C200HG-(Z)E
C-series
C200HX-(Z)E
C-series
CQM1H
CS-series
CS1G
CS-series
CS1H
CS-series
CS1G-H
CS-series
CS1H-H
CJ-series
CJ1G
273
Model List
Appendix F
CPU Units (for Connection Via an High-speed NT Link (1:N))
Model
CS1G-CPU42-EV1
CS1G-CPU43-EV1
CS1G-CPU44-EV1
CS1G-CPU45-EV1
CS1H-CPU63-EV1
CS1H-CPU64-EV1
CS1H-CPU65-EV1
CS1H-CPU66-EV1
CS1G-CPU42H
CS1G-CPU43H
CS1G-CPU44H
CS1G-CPU45H
CS1H-CPU63H
CS1H-CPU64H
CS1H-CPU65H
CS1H-CPU66H
CS1H-CPU67H
CJ1G-CPU44
CJ1G-CPU45
Specification
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
Features a connector for RS-232C connections.
PLC Type
CS-series
CS1G
CS-series
CS1H
CS-series
CS1G-H
CS-series
CS1H-H
CJ-series
CJ1G
Note The direct high-speed 1:N NT Link connection is not supported by CS1-series CPU Units without the
-EV1 suffix.
274
Model List
Appendix F
CPU Units (Connected by C200H Direct Communications)
Model Product Name
C20H C20H-C @DR-DE-V1
C20H-C @DT-DE-V1
C28H-C
@DR-DE-V1
C28H-C @DT-DE-V1
C40H-C @DR-DE-V1
C40H-C @DT-DE-V1
C60H-C @DR-DE-V1
C60H-C
@DT-DE-V1
C200H-CPU01-E
C200H-CPU03-E
C200H-CPU11-E
C200H-CPU21-E
C200H-CPU23-E
C200H-CPU31-E
C200HS-CPU01-E
C200HS-CPU03-E
C200HS-CPU11-E
C200HS-CPU21-E
C200HS-CPU23-E
C200HS-CPU31-E
C200HE-CPU11-E
C200HE-CPU32-E
C200HE-CPU42-E
C200HG-CPU33-E
C200HG-CPU43-E
C200HG-CPU53-E
C200HG-CPU63-E
C200HX-CPU34-E
C200HX-CPU44-E
C200HX-CPU54-E
C200HX-CPU64-E
C28H
C40H
C60H
C200H
C200HS
C200HE
C200HG
C200HX
RS-232C/RS-422A Link Adapter
Model
NT-AL001
Specification
RS-232C: 9-pin connector
RS-422A: 8-pin terminal block
RS-422A Converter
Model
CJ1W-CIF11
RS-232C Adapter
Model
CPM1-CIF01
Specification
Converts RS-232C to RS-422A or RS-485.
Specification
Connect the RS-232C port of the NT20 and the peripheral port of the CPM1.
275
Model List
Appendix F
Related Products
Name
Support Tool
Options
Model
NT-ZJCAT1-EV4
NT20S-KBA04
NT20S-KBA01
NT-MF261
Parts Used for Connection
Remarks
For IBM PC/AT compatible, media: CD-ROM
Reflection-suppressing protective sheet for NT20
Chemical-resistant cover to NT20
Memory Unit for NT20
Cables with Connectors
Cable Length Model
XW2Z-200S
XW2Z-500S
XW2Z-200T
XW2Z-500T
C200H-CN311
NT20M-CNP711
C200H-CN711
NT20M-CNP221
C200H-CN221
NT20M-CNP521
C200H-CN521
NT20M-CNP131
C200H-CN131
C200H-CN312
NT20M-CNP712
C200H-CN712
NT20M-CNP222
C200H-CN222
2 m
5 m
2 m
5 m
30 cm
70 cm
2 m
5 m
10 m
30 cm
70 cm
2 m
Applicable Units
Host link units with 25-pin connectors
Host link units and CPU units with 9-pin connectors
C200H, C200HS,
C200HX/HG/HE
Communications Method
Host link
Host link,
NT link (1 to 1)
C200H direct communications
C @@H
Connecting Cables (for Host Link, NT Link, and RS-232C)
Model
AWG28×5P
IFVV-SB
CO-MA-VV-SB
5P×28AWG
Specification
Multiconductor shielded cable (FUJIKURA, Ltd.)
Multiconductor shielded cable (HITACHI Cable, Ltd.)
Applicable Connectors (for Host Link, NT Link, and RS-232C)
Name
Connector
Connector cover
XM2A-2501
Model
XM2A-0901
DB-25P
XM2S-2511
XM2S-0911
DB-C2-J9
Remarks
25-pin, manufactured by OMRON
9-pin (Plug), manufactured by OMRON
25-pin, manufactured by JAE
25-pin, manufactured by OMRON
9-pin, manufactured by OMRON
25-pin, manufactured by JAE
276
Appendix G
Option List
Interface Unit ... NT20-IF001
This is the Interface Unit used when connecting a Host Interface Unit for C200H direct communications.
The PTs and Interface Units that can be used with the NT20-IF001 are listed in the following table. Be sure to use an applicable PT and Interface Unit.
Mounting Attachment
NT20-IF001
Applicable PTs
NT20-series PTs
Applicable Interface Units
NT600M-LB122-V1
C200H Interface Unit ... NT600M-LB122-V1
This is the Interface Unit for C200H communications.
Reflection-suppressing Protective Sheet ... NT20-KBA04
Stuck to the display to prevent it from being soiled. The entire sheet is colorless and transparent.
277
Option List
Appendix G
Chemical-resistant Cover (NT20-KBA01)
Covers the front panel and protects it from chemical agents. The entire sheet is milky white and made of silicone rubber.
The protection the cover affords is summarized below.
Protects Against
Boric acid
Sulfuric acid
Nitric acid
Ammonia gas
Carbon dioxide
Phenol
Glycerin
Ammonia water
Calcium chloride
Developing fluid (“hypo”)
Acetaldehyde
Lard
Does Not Protect Against
Hexane
Lubricating oils
Benzene
Butane
Carbonic acid
Chlorinated solvents
Napthalene
Soya oil
Toluene
For information on protection against chemical agents not included in the table above, please ask OMRON. (If it is a chemical agent to which silicone rubber is recognized to be resistant, the cover can be used with confidence even if that chemical agent is not listed in the “Protects Against” column above.
Note
(1) This cover does not afford protection against all chemical agents.
(2) Since the cover is milky white, it reduces the clarity of the display a little.
(3) This cover is intended to be affixed to the display in order to provide protection against chemical agents. It will not provide protection against chemical agents that enter through the installation panel or through the gap between the cover and the display.
Memory Unit (NT-MF261)
This is a special unit for reading/writing the screen data and the system programs in an NT20. Data is transmitted by DIP switch setting at the Memory Unit.
278
Appendix H
Special Characters
English Character Codes
Pin 2 of SW2 must be ON to enable English language messages to use the following codes.
Example: Hex code is represented by 30, decimal code by 48, and character by 0.
30
48
0
Code 20 and 32 in the table represents a space, as indicated by “SP.”
23456-
Hex Digits
1st
2nd
-0
-1
-2
-3
-4
-5
-6
-7
-8
-9
-A
-B
-C
-D
-E
-F
,
-
.
/
(
)
’
”
!
SP 30
48
31
49
32
50
#
$
%
&
35
53
36
54
33
51
34
52
*
+
0
1
2
3
4
5
6
37
55
38
56
7
8
39
57
3A :
58
9
3B ;
59
3C <
60
3D =
61
3E >
62
3F
63
?
2D
45
2E
46
2B
43
2C
44
2F
47
29
41
2A
42
27
39
28
40
25
37
26
38
23
35
24
36
20
32
21
33
22
34
@
A
B
C
D
E
F
47
71
48
72
G
H
49
73
I
4A J
74
4B K
75
4C L
76
4D M
77
4E N
78
4F O
79
45
69
46
70
43
67
44
68
40
64
41
65
42
66
P
Q
R
S
T
U
V
57
87
58
88
W
X
59
89
Y
5A Z
90
5B [
91
5C \
92
5D ]
93
5E ^
94
5F _
95
55
85
56
86
53
83
54
84
50
80
51
81
52
82 f
` a b c d e
67
103
68
104
69
105
6A j
106 i g h
6B k
107
6C l
108
6D m
109
6E n
110
6F o
111
63
99
64
100
65
101
66
102
60
96
61
97
62
98
7-
t r p q s u v
77
119
78
120 w x
79
121 y
7A z
122
7B {
123
7C |
124
7D }
125
7E ~
126
7F
127
73
115
74
116
75
117
76
118
70
112
71
113
72
114
8-
Ç
ü
é
â
ä
à
å
87
135
88
136
ç
ê
89
137
ë
8A è
138
8B ï
139
8C î
140
8D ì
141
8E Ä
142
8F Å
143
83
131
84
132
85
133
86
134
80
128
81
129
82
130
9-
È
æ
Æ
ô
ö
ò
û
97
151
98
152
ù
ÿ
99
153
Ö
9A Ü
154
9B ¢
155
9C £
156
9D ¥
157
9E Pt
158
9F ƒ
159
93
147
94
148
95
149
96
150
90
144
91
145
92
146
279
Special Characters
Hex Digits
1st
2nd
-0
-1
-2
-3
-4
-5
-6
-7
-8
-9
-A
-B
-C
-D
-E
-F
171
AC
172
AD
173
AE
174
AF
175
167
A8
168
A9
169
AA
170
AB
163
A4
164
A5
165
A6
166
A7
A0
160
A1
161
A2
162
A3
ABC-
¡
í
á
ó
ú
ñ
Ñ a o
¿
1
/
2
1
/
4
«
»
187
BC
188
BD
189
BE
190
BF
191
183
B8
184
B9
185
BA
186
BB
179
B4
180
B5
181
B6
182
B7
B0
176
B1
177
B2
178
B3
Note Used as the prefix for mark data codes (2 bytes).
203
CC
204
CD
205
CE
206
CF
207
199
C8
200
C9
201
CA
202
CB
195
C4
196
C5
197
C6
198
C7
C0
192
C1
193
C2
194
C3
219
DC
220
DD
221
DE
222
DF
223
215
D8
216
D9
217
DA
218
DB
211
D4
212
D5
213
D6
214
D7
D0
208
D1
209
D2
210
D3
D-
Appendix H
FE-
∞
φ
ε
∩
µ
τ
Σ
σ
Γ
π
α
β
Ω
δ
Φ
Θ
235
EC
236
ED
237
EE
238
EF
239
231
E8
232
E9
233
EA
234
EB
227
E4
228
E5
229
E6
230
E7
E0
224
E1
225
E2
226
E3
•
√ n
.
°
÷
≈
⌠
⌡
≥
≤
≡
±
2
■
(See note.)
251
FC
252
FD
253
FE
254
FF
255
247
F8
248
F9
249
FA
250
FB
243
F4
244
F5
245
F6
246
F7
F0
240
F1
241
F2
242
F3
280
Appendix I
Function Restrictions Depending on the
Support Tool
Screens can be created for Host link, NT link, or C200H direct communications by using the conventional Support Tool indicated below.
In addition, the NT series Support Tool (Ver.2.
@) can be used with Ver.4 of the direct connection function.
However, when the above Support Tool is used, restrictions apply to some functions as shown in the table below.
The expressions used for the Support Tools In the table have the following meanings.
NT V2: NT Series Support Tool (Ver.2.
@)
Support Tool
NT V2
NT Model Direct
Connection
NT20M Ver. 4
NT20S Ver. 4
NT20S Ver. 5
Communications Mode Support Tool
Mode
(NT20S memory switch)
Standard NT20M
Standard/High-speed
Standard/High-speed
NT20S
NT20S
Restrictions
250 screens max.,
Thumbwheel numeral settings not possible, no upper/ lower limits, hexadecimal input not possible, indirect specification not possible, touch switch input notification fixed as “momentary”, data transmission in screen units not possible.
No restriction
The NT20 cannot be used with combinations of Support Tools and settings other than those indicated above.
Reference: The RS-232C can be used in the same way with the NT series Support Tool (Ver.2.
necessary Support Tool and “Tool Mode” (NT20 memory switch) settings in this case are as follows:
NT Model: NT20S
@). The
Direct setting: No
Communications mode: Standard/High-speed
Tool Mode: NT20S
281
Function Restrictions Depending on the Support Tool
Appendix I
282
Index
Numerics
25-pin connector
,
9-pin connector
A
allocatable bits and words
automatic reset function
,
B
backlight
,
backlight mode
bar graphs
before operating
,
buzzer attribute
,
C
cable preparation
,
changing displayed numerals or character strings
,
changing displayed numerical values or character strings
,
changing the status of allocated bits
changing the system settings
,
character string memory table direct specification
displaying and referencing
,
indirect specification
initialization setting
number of registration words
setting
,
checking the PT setting
Communications Board
communications methods
,
communications port
,
communications type
,
comparison between NT20S, NT20M, and NT20
compatibility with NT2OM/NT20S
,
CompoBus/S Master Control Units manual
,
connecting directly between RS-232C ports
,
connecting the NT Support Tool
,
connection method
continuous buzzer
continuous buzzer sound
,
controlling the display elements
,
controlling the NT20 status
CPUs
,
D
data transmission in screen units
,
description of parts
,
determining touch switch status
,
dimensions
,
DIP switch settings
,
display numeric values (numeral table)
,
reverse and flashing display
display elements character-string memory table
,
lamps
numeral memory table
touch switches
,
displaying the system menu
,
displays bar graphs
characters (character-string memory table)
,
characters (text)
,
lamps
marks
,
numeric keys
,
touch switches
,
E
EC Directives
EMI Standard
EMS Standard
enlarged display
,
error messages
F
file units
G
graph frame
283
284
H
hardware faults
host link method
Host Link Unit
Host Link Units manual
,
I
I/O check
,
buzzer
,
communications with the Support Tool
,
LCD
,
LED
screen memory
,
touch switches
,
initialization by using the DIP switch
,
initialization by using the system menu
,
initializing memory
,
inspection and cleaning
,
intermittent buzzer
,
intermittent buzzer sound
,
IP65 waterproof requirements
,
K
key press sound
,
L
lamps
,
language function
M
maintenance of the NT20
,
marks
,
memory switches
,
memory table character-string memory table
,
copying
,
numeral memory table
menu item
Maintenance Mode
Quit
,
Transmit Mode
Index
menu tree
model list
,
N
ng
,
notification of display elements
notification of NT20 status
,
notification of numbers to the PLC
,
notification operation alternate
,
momentary
,
reset
,
set
,
NT Link
1:1 NT Link
,
1:N NT Link
,
high-speed 1:N NT Link
NT Support Tool connecting
manual
,
NT20 status control
,
numeral memory table direct specification
displaying and referencing
,
indirect specification
initialization setting
,
number of registration words
numeral setting
numeric key type
,
thumbwheel type
,
numeric keys
,
O
operating status
operation flow
operation panel
operation with the system menu
,
P
power supply connection
precautions
,
EC Directives
,
Programming Tools manuals
,
PT operating status
,
PT status
PT status control area
,
PT status notify area
R
radiated emission
S
screen child screen
classification
,
composition of the screen
,
continuous screen
,
normal screen
,
NT20 screen
overlapping screen
parent screen
,
screen display
screen management
special screen number
switching the continuous screens
,
screen attributes backlight attribute
,
buzzer attribute
numeral setting attribute
screen data
screen display
screen switch setting
screen switch strobe
screen switch timing
,
screen switching function
,
screen switching strobe
,
screens creating
,
selecting the host communications method
selecting the host communications port
,
selecting the host link communications speed
selecting the menu items
selecting the NT link (1
N) communications speed
selecting unit numbers
,
Serial Communications Board
Serial Communications Boards manuals
Serial Communications Unit
Index
serial port A
serial port B
,
setting the buzzer
,
smoothing
,
soldering
,
specifications
,
starting the NT20
,
Support Tool connecting the NT Support Tool
,
Support Tool mode setting
,
switching the screen display
,
switching to the RUN mode
System Installer manual
,
system key functions
,
system menu
system program erasing
transferring
system transfer tool
T
touch switches
transmitting the screen data
U
upgrade bar graphs
upper/lower limit check
,
using numeric keys
,
using the thumbwheel type
285
286
Index
Revision History
A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
Cat. No. V091-E1-01
Revision code
The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version.
Revision code
01
Date
March 2007 Original production
Revised content
287
288
Revision History
OMRON Corporation
Control Devices Division H.Q.
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7109/Fax: (81)75-344-7149
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, NL-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
1 East Commerce Drive, Schaumburg, IL 60173
U.S.A.
Tel: (1)847-843-7900/Fax: (1)847-843-8568
OMRON ASIA PACIFIC PTE. LTD.
83 Clemenceau Avenue,
#11-01, UE Square,
Singapore 239920
Tel: (65)6835-3011/Fax: (65)6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120 China
Tel: (86)21-5037-2222/Fax: (86)21-5037-2200
Authorized Distributor:
Cat. No. V091-E1-01 Note: Specifications subject to change without notice
This manual is printed on 100% recycled paper.
Printed in Japan
Download
Advertisement
Key features
Downsized body
Construction best suited to the FA environment
A Host Link I/F Unit, Screen Data Memory, and a System ROM Are All Incorporated
Touch Switch Operation
Compatibility with NT20M/NT20S
Character display
Figure display
Memory data display
Bar graph display
Lamp display
Frequently asked questions
The NT20 is a programmable terminal used to display and transmit information in an FA site. It can be easily installed and used.
The NT20 has a downsized body, is built with construction best suited to the FA environment, incorporates a Host Link I/F Unit, Screen Data Memory, and a System ROM, supports Touch Switch Operation, and is compatible with NT20M/NT20S.
The NT20 supports Host Link (direct) and NT Link communications methods. The NT20-ST128 also supports RS-232C communications.