Settings. Lupus Electronics LUPUSEC-XT1
Add to My manuals130 Pages
Lupus Electronics LUPUSEC-XT1 is an advanced security system designed to protect your home or business. With its intuitive interface and wide range of features, the LUPUSEC-XT1 makes it easy to keep your property safe and secure.
Some of the key features of the LUPUSEC-XT1 include:
- Easy to use: The LUPUSEC-XT1 features a user-friendly interface that makes it easy to set up and operate.
- Remote access: You can arm and disarm your system, view live video, and receive alerts from anywhere with the LUPUSEC app.
- Expandable: The LUPUSEC-XT1 can be expanded to include a variety of sensors, detectors, and cameras, so you can customize your system to meet your specific needs.
advertisement
Settings
Time settings
Delay upon entry
If someone enters the house with the LUPUSEC-XT1 being armed, you may need a while e.g. to enter the code in the keypad. Specify this delay until the alarm is triggered here. However, this delay is active only for sensors with the
“Entrance area” setting. Sensors with the “Burglary” setting trigger the alarm immediately.
Delay upon exit
If you arm the alarm system e.g. to leave the house, you may need a while to lock the door from outside. Specify this delay until the system is armed here.
Only after the specified time has elapsed, sensors with the “Entrance area” setting will trigger an alarm.
Note:
This function is active only for arming with keypad or remote control.
Delay upon entry (Home mode)
In the Home mode, only sensors with the “Burglary” setting can trigger alarms.
If the Home mode is activated and a sensor with the “Entrance area” setting is released, the alarm is triggered only after the specified time has elapsed. This provides you with enough time to disarm the XT1.
22
Delay upon exit (Home mode)
If the Home mode is activated e.g. via the keypad, you usually need time to leave the premises. Specify this delay until an alarm can be triggered here.
Alarm duration
This item refers to the alarm duration of all integrated sirens. If an alarm is triggered and the sirens activated, specify the maximum alarm duration. If the control unit is disarmed again, the acoustic alarm goes off.
Note:
If a shorter alarm duration than in this menu item is defined by means of the DIP switches (SW3+4) of an external siren, then the alarm of the external siren is aborted prematurely. The other way round, the alarm duration of an external siren is aborted prematurely with the alarm duration as described, if a longer (maximum) alarm duration is defined by means of the DIP switches (SW3+4). If the alarm duration is
„deactivated“, the external sirens will become active for the duration defined with the
DIP switches (SW3+4).
Siren delay
Specifies the duration of the delay of all audible alarms internal siren + external sirens). This function is deactivated by default.
Motion check
This function is the countdown timer (default: deactivated). If the defined time elapses without being reset by a motion detector before, the XT1 control unit will send a message to the alarm center (if set-up via contact ID).
Sensor check
Motion detectors and door contacts have a “Supervisor” function, which sends data to the control unit at regular intervals to signal that the sensor is still available and functioning. You can set this function here. If no “Supervisor” signal is registered within the specified interval, the sensor is shown as “out of service”.
Signal tones
during delay upon entry
Sounds an audio warning during the time specified in “Time settings”, until the time has elapsed. This applies to sensors with the “Entrance area” setting only.
during delay upon exit
Sounds an audio warning during the time specified in “Time settings”, until the time has elapsed.
Note:
This function is active only for arming with keypad or remote control.
during delay upon entry (Home mode)
Sounds an audio warning during the time specified in “Time settings”, until the
23
time has elapsed. This applies to sensors with the “Home entry” setting only with the system in Home mode.
during delay upon exit (Home mode)
Sounds an audio warning, when the Home mode is activated, during the time specified in “Time settings”, until the time has elapsed.
Ring tone for entrance areas
Specify whether a signal tone is to sound, if an “entrance area” sensor is released. This applies to sensors with the “Entrance area” setting only.
Further settings
Remote controls
To set, whether or not the LUPUSEC-XT1 alarm system is to notify the alarm center if a remote control is used.
Forced arming
o
Off: If the system is armed irrespective of failures (system errors, batteries, power supply, open detectors or general status of detectors) with the keypad or remote control, two brief tones sound to indicate a failure - the system remains disarmed. If you arm the system again within 10 seconds, the system will be armed irrespective of the failures.
Note:
A list of the “failures” is shown on the web interface for about one second upon arming. o
On: The system is armed directly with the keypad/remote control, irrespective of failures in the system (tamper, battery, door open, etc.).
24
advertisement
Key Features
- Easy to use interface
- Remote access with LUPUSEC app
- Expandable system with a variety of sensors and cameras
- Motion detection
- Door/window sensors
- Smoke and heat detectors
- Panic button
- Built-in siren
- Tamper protection
- Battery backup
Related manuals
Frequently Answers and Questions
How do I set up the LUPUSEC-XT1?
Can I add additional sensors or detectors to my LUPUSEC-XT1?
What is the range of the LUPUSEC-XT1's wireless sensors?
advertisement
Table of contents
- 4 Introduction
- 4 Disclaimer
- 6 Important safety information
- 6 If you detect defects
- 7 Intended use
- 8 Hardware description
- 9 Scope of delivery
- 10 Put the LUPUSEC-XT1 into operation
- 10 Control unit
- 10 Place of installation
- 11 Install the control unit
- 11 Connect the control unit
- 13 Access to the main interface of the LUPUSEC-XT
- 15 Menu description
- 15 Home menu
- 15 Overview
- 17 History
- 18 Captured events
- 19 Time frame
- 19 PIN codes
- 21 Control unit menu
- 21 Status
- 22 Settings
- 25 Siren
- 26 Date & Time
- 27 Sensors menu
- 28 Sensors settings
- 31 Range
- 31 Bypass
- 32 Devices
- 34 Wireless sockets (PSS)
- 35 Network menu
- 35 Settings
- 38 Cameras
- 40 Settings menu
- 40 Contact ID
- 41 Contact ID Syntax
- 42 Special codes
- 43 Text message report
- 47 E-mail
- 49 Upload
- 50 Automation
- 52 System menu
- 52 Admin
- 53 Firmware
- 53 Default settings
- 54 Log files
- 55 Remote access via the internet
- 57 Create Dynamic DNS account
- 62 Access via the LUPUSEC app (Android + iOS)
- 63 Profile list
- 64 Main menu
- 65 Navigation within the app
- 66 Mobile phone access via the mobile web interface
- 68 The user interface of the LUPUSEC-XT1 mobile app
- 71 Description of sensors and controls
- 72 XT Keypad
- 73 Put the keypad into operation
- 75 Window/door contact
- 76 Put the window/door contact into operation
- 77 Wireless indoor siren
- 77 Put the wireless indoor siren into operation
- 80 Wireless outdoor siren
- 80 Put the wireless outdoor siren into operation
- 83 Smoke detector
- 84 Put the smoke detector into operation
- 86 PIR motion detector
- 86 Put the PIR motion detector into operation
- 88 Water detector
- 88 Put the water detector into operation
- 89 Remote control
- 89 Put the remote control into operation
- 90 Medical emergency controller
- 90 Put the medical emergency controller into operation
- 91 Wireless sockets (PSS)
- 91 Put the wireless socket (with electric meter) into operation
- 92 Put the wireless socket (without electric meter) into operation
- 93 Glass breakage detector
- 93 Put the glass breakage detector into operation
- 95 PIR network camera
- 95 Put the PIR network camera into operation
- 98 Temperature sensor
- 98 Put the temperature sensor into operation
- 99 Wireless relay
- 99 Put the wireless relay into operation
- 101 Magnetic locking device
- 102 Install the magnetic locking device to the door and put it into operation
- 103 Mechanical locking device
- 104 Install the mechanical locking device to the door and put it into operation
- 106 Panic button
- 106 Put the panic button into operation
- 107 Wireless repeater
- 108 Connect the wireless repeater to the control unit
- 110 CO detector
- 110 Put the CO detector into operation
- 111 Heat detector
- 111 Put the heat detector into operation
- 113 Wireless sensor input
- 114 Put the wireless sensor input into operation
- 116 Wireless lock contact
- 116 Install the wireless lock contact to the door and put it into operation
- 118 In-wall relay with electric meter
- 118 Put the in-wall relay with electric meter into operation
- 119 In-wall relay without electric meter
- 119 Put the in-wall relay without electric meter into operation
- 121 Tag reader
- 122 Put the tag reader into operation
- 124 Two-way motion detector
- 126 Put the PIR/microwave motion detector into operation