Put the smoke detector into operation. Lupus Electronics LUPUSEC-XT1

Add to My manuals
130 Pages

advertisement

Put the smoke detector into operation. Lupus Electronics LUPUSEC-XT1 | Manualzz

5.

Mounting bracket

6.

Attachment hook

Put the smoke detector into operation

1.

After you inserted the batteries, two brief signals sound. The LED starts flashing.

You have six minutes (warm-up phase) to add the smoke detector to the control unit.

2.

Open the configuration page of the control unit and start the login process in the

Sensors menu.

3.

Press the Test button at the smoke detector. Two brief signal tones sound.

4.

If the control unit detects the device, it emits a signal tone for confirmation.

5.

Now add the smoke detector to the control unit.

Note:

The calibration starts after the six minutes warm-up phase of the smoke detector.

A short beep sounds every 100 seconds during these six minutes. The calibration takes about 2 to 16 minutes and is completed at the end with two successful signals. If the calibration failed after 16 minutes, a constant beep will sound. In that case, remove the batteries and restart with step 1.

You cannot integrate the smoke detector during the calibration; this is possible only before or after the calibration process.

6.

Perform an optional range test.

For this purpose, open the menu SensorsRange and click on Start. Take the smoke detector to the place of installation and press the Test button of the smoke detector. The test menu of the control unit indicates the signal strength of the radio transmission. The higher the value the better the radio signal (1-9).

Mounting of smoke detector:

1. Use the bracket (5) as a template to drill the holes.

2. Mount the bracket so that the two hooks (6) face down.

3. Press the installation notches (4) onto the attachment hooks (6) and lock it with pressure and a clockwise turn, making sure that the line located at the side of the smoke detector is directly below one of the hooks.

In case of alarm:

If the smoke concentration exceeds the threshold, the detector will immediately report this to the XT1 and additionally emit a loud signal tone for ten seconds. If the smoke concentration measured after these ten seconds is still high, a signal tone is emitted again for ten seconds, until there is no more smoke in the measuring chamber. If you press the Test button in case of an alarm, the smoke detector will be deactivated for ten minutes. After these ten minutes, the smoke detector will sound two signal tones and return to its normal operating mode .

Place of installation of smoke detector:

Install the smoke detector always at the highest point and with minimum distance

84

of 60 cm to the wall.

Do not install the smoke detector in kitchens or bathrooms or other moist rooms to avoid false alarms and to increase the service life.

Do not install the smoke detector close to air conditioning systems or fans.

Cleaning:

Check the smoke detector regularly for proper function (TEST button) and clean it, if it is soiled.

In that case, carefully suction clean or blow clean it.

Do not use any liquids for cleaning.

Water must not enter the inside of the device.

Note:

In case of an alarm, the control unit and the smoke detector will alert. Additionally installed smoke detectors will not trigger alarms.

Even if the smoke detector has lost contact to the control unit (radio interference, control unit off, large distance), it will always react to smoke and alert you with its own siren!

Replace the smoke detector after ten years at the latest for your own safety.

85

advertisement

Key Features

  • Easy to use interface
  • Remote access with LUPUSEC app
  • Expandable system with a variety of sensors and cameras
  • Motion detection
  • Door/window sensors
  • Smoke and heat detectors
  • Panic button
  • Built-in siren
  • Tamper protection
  • Battery backup

Related manuals

Frequently Answers and Questions

How do I set up the LUPUSEC-XT1?
Refer to the included user manual for step-by-step instructions on how to set up your LUPUSEC-XT1.
Can I add additional sensors or detectors to my LUPUSEC-XT1?
Yes, the LUPUSEC-XT1 can be expanded to include a variety of sensors, detectors, and cameras. See the product manual for more information.
What is the range of the LUPUSEC-XT1's wireless sensors?
The range of the wireless sensors depends on the specific sensor and the environment in which it is installed. Refer to the product manual or consult the manufacturer for more information.

advertisement

Table of contents