Lupus Electronics LUPUSEC-XT1 is an advanced security system designed to protect your home or business. With its intuitive interface and wide range of features, the LUPUSEC-XT1 makes it easy to keep your property safe and secure.
Some of the key features of the LUPUSEC-XT1 include:
- Easy to use: The LUPUSEC-XT1 features a user-friendly interface that makes it easy to set up and operate.
- Remote access: You can arm and disarm your system, view live video, and receive alerts from anywhere with the LUPUSEC app.
- Expandable: The LUPUSEC-XT1 can be expanded to include a variety of sensors, detectors, and cameras, so you can customize your system to meet your specific needs.
advertisement
Cameras
In the Cameras menu, you can integrate all LUPUSNET HD IP cameras as well as the LUPUSTEC-LE800+ and LE800 D1 series into the LUPUSEC-XT1. You can add a maximum of four cameras. In theory, you can show pictures from any camera/recorder, if the device has an MJPEG path, which you need to enter. Please refer to the product manual in this regard or contact the product manufacturer.
To add a LUPUSNET HD IP camera, enter a link according to the following syntax in one of the „URL camera“ boxes:
http://Username:Password@Camera-IP-
ADDRESS:PORT/GetData.cgi?CH=Streamnumber
Example of a camera integration:
User name: admin
Password: admin
IP address: test.lupus-ddns.de
Port: 10030
Stream 2: ?CH=2
In the example, the link needs to look as follows: http://admin:[email protected]:10030/GetData.cgi?CH=2
The command “/GetData.cgi” shows the camera’s JPEG stream, which transmits at up to 25 frames/second. If the data volume is too big for your local network, you can downsize the stream to a refreshment rate of one picture every three seconds. For this purpose, use the following extension: “/GetImage.cgi?Size=640x480”
In our example, the link would look as follows:
38
http://admin:[email protected]:10030/GetImage.cgi?Size=640x480
Use the following syntax to add the image of a LUPUSTEC recorder (LE800
Plus or D1 series):
http://Username:Password@DVR-ADDRESS:PORT/cgibin/net_jpeg.cgi?ch=Videochannelno.
Example of a video recorder integration:
User name: test
Password: test
DVR address: test.lupus-ddns.de
Port: 10001
Camera image/channel 1: /cgi-bin/net_jpeg.cgi?ch=0
Note:
To integrate an analog DVR, always subtract 1 from the required. Channel 4 corresponds to ch=3, channel 1 ch=0.
In our example, the link then looks as follows: http://test:[email protected]:10001/cgi-bin/net_jpeg.cgi?ch=0
Note:
Do not use Microsoft Internet Explorer, because it causes problems with the camera image display.
If you have any difficulties to implement your cameras, please do not hesitate to contact our support hotline by calling 0049-6341-93 55 30!
The PIR network camera is not integrated via the Cameras menu, but as a sensor.
39
advertisement
Key Features
- Easy to use interface
- Remote access with LUPUSEC app
- Expandable system with a variety of sensors and cameras
- Motion detection
- Door/window sensors
- Smoke and heat detectors
- Panic button
- Built-in siren
- Tamper protection
- Battery backup
Related manuals
Frequently Answers and Questions
How do I set up the LUPUSEC-XT1?
Can I add additional sensors or detectors to my LUPUSEC-XT1?
What is the range of the LUPUSEC-XT1's wireless sensors?
advertisement
Table of contents
- 4 Introduction
- 4 Disclaimer
- 6 Important safety information
- 6 If you detect defects
- 7 Intended use
- 8 Hardware description
- 9 Scope of delivery
- 10 Put the LUPUSEC-XT1 into operation
- 10 Control unit
- 10 Place of installation
- 11 Install the control unit
- 11 Connect the control unit
- 13 Access to the main interface of the LUPUSEC-XT
- 15 Menu description
- 15 Home menu
- 15 Overview
- 17 History
- 18 Captured events
- 19 Time frame
- 19 PIN codes
- 21 Control unit menu
- 21 Status
- 22 Settings
- 25 Siren
- 26 Date & Time
- 27 Sensors menu
- 28 Sensors settings
- 31 Range
- 31 Bypass
- 32 Devices
- 34 Wireless sockets (PSS)
- 35 Network menu
- 35 Settings
- 38 Cameras
- 40 Settings menu
- 40 Contact ID
- 41 Contact ID Syntax
- 42 Special codes
- 43 Text message report
- 47 E-mail
- 49 Upload
- 50 Automation
- 52 System menu
- 52 Admin
- 53 Firmware
- 53 Default settings
- 54 Log files
- 55 Remote access via the internet
- 57 Create Dynamic DNS account
- 62 Access via the LUPUSEC app (Android + iOS)
- 63 Profile list
- 64 Main menu
- 65 Navigation within the app
- 66 Mobile phone access via the mobile web interface
- 68 The user interface of the LUPUSEC-XT1 mobile app
- 71 Description of sensors and controls
- 72 XT Keypad
- 73 Put the keypad into operation
- 75 Window/door contact
- 76 Put the window/door contact into operation
- 77 Wireless indoor siren
- 77 Put the wireless indoor siren into operation
- 80 Wireless outdoor siren
- 80 Put the wireless outdoor siren into operation
- 83 Smoke detector
- 84 Put the smoke detector into operation
- 86 PIR motion detector
- 86 Put the PIR motion detector into operation
- 88 Water detector
- 88 Put the water detector into operation
- 89 Remote control
- 89 Put the remote control into operation
- 90 Medical emergency controller
- 90 Put the medical emergency controller into operation
- 91 Wireless sockets (PSS)
- 91 Put the wireless socket (with electric meter) into operation
- 92 Put the wireless socket (without electric meter) into operation
- 93 Glass breakage detector
- 93 Put the glass breakage detector into operation
- 95 PIR network camera
- 95 Put the PIR network camera into operation
- 98 Temperature sensor
- 98 Put the temperature sensor into operation
- 99 Wireless relay
- 99 Put the wireless relay into operation
- 101 Magnetic locking device
- 102 Install the magnetic locking device to the door and put it into operation
- 103 Mechanical locking device
- 104 Install the mechanical locking device to the door and put it into operation
- 106 Panic button
- 106 Put the panic button into operation
- 107 Wireless repeater
- 108 Connect the wireless repeater to the control unit
- 110 CO detector
- 110 Put the CO detector into operation
- 111 Heat detector
- 111 Put the heat detector into operation
- 113 Wireless sensor input
- 114 Put the wireless sensor input into operation
- 116 Wireless lock contact
- 116 Install the wireless lock contact to the door and put it into operation
- 118 In-wall relay with electric meter
- 118 Put the in-wall relay with electric meter into operation
- 119 In-wall relay without electric meter
- 119 Put the in-wall relay without electric meter into operation
- 121 Tag reader
- 122 Put the tag reader into operation
- 124 Two-way motion detector
- 126 Put the PIR/microwave motion detector into operation