Put the tag reader into operation. Lupus Electronics LUPUSEC-XT1
Add to My manuals130 Pages
Lupus Electronics LUPUSEC-XT1 is an advanced security system designed to protect your home or business. With its intuitive interface and wide range of features, the LUPUSEC-XT1 makes it easy to keep your property safe and secure.
Some of the key features of the LUPUSEC-XT1 include:
- Easy to use: The LUPUSEC-XT1 features a user-friendly interface that makes it easy to set up and operate.
- Remote access: You can arm and disarm your system, view live video, and receive alerts from anywhere with the LUPUSEC app.
- Expandable: The LUPUSEC-XT1 can be expanded to include a variety of sensors, detectors, and cameras, so you can customize your system to meet your specific needs.
advertisement
Switch no. Position
SW 1
ON Learn / add mode
OFF
Description
Normal Operation Standard)
SW 2
SW 3
SW 4
SW 5
ON Factory setting
OFF Normal operation (default)
OFF
System setting
OFF
MUST be OFF, as otherwise no function
OFF Reserved
Put the tag reader into operation
Installation of the tag reader:
1.
Install the tag readers indoors only.
2.
Remove the front of the tag reader by unscrewing the lower screw.
3.
Use both screw holes to mark the drill holes at the wall.
4.
Make sure that the tamper contact of the tag reader lies flat on the ground.
5.
Tighten the tag reader.
6.
Insert the batteries. The Power LED lights up for a few seconds and a signal sounds.
Add the tag reader to the control unit:
1.
Open the control unit menu and then the sub-menu Sensors Add and click
Start.
2.
Start the installation mode by pressing the Arm or Disarm button and then promptly setting switch 1 to ON. The Status LED starts flashing and one long signal tone followed by two short signal tones sound.
3.
Press the Disarm button of the tag reader.
4.
The control unit indicates the tag reader as “Keypad” (XT1) or “Tag reader” (XT2).
5.
Add the tag reader to the control unit.
6.
Exit the learn mode of the control unit.
7.
Leave the installation mode of the tag reader by setting SW1 to OFF again, which is acknowledged with four short signal tones. Then reinstall the front of the tag reader by tightening the lower screw.
Note:
The installation mode ends automatically after five minutes at the latest. To restart the installation mode, you need to set SW1 to ON again.
Add a tag to the tag reader:
1.
Start the installation mode by pressing the Arm or Disarm button and then
122
promptly setting switch 1 to ON. The Status LED starts flashing and one long signal tone followed by two short signal tones sound.
2.
Press the Arm button once to start the tag learn mode. The Status LED lights up for five seconds and one signal tone sounds.
3.
During this time, hold a tag in front of the tag reader panel. The Status LED flashes fast three times and two signal tones sound, indicating the successful integration of a tag in the tag reader.
4.
If you want to add several tags, hold them one after the other (at intervals of 5 seconds) in front of the tag reader re restart the entire process.
5.
Exit the installation mode of the tag reader by setting SW1 back to OFF.
Note:
With the new tag reader version (available since the beginning of 2015), you can add an unlimited number of tags.
You can add a tag to an unlimited number of tag readers.
Only one signal tone indicates that this tag was already added.
Four signal tones indicate that the maximum tag number (6) is reached.
How to use the tag reader:
After having completed the tag reader installation as described above, you can use the tag reader as follows:
1.
Arming/disarming
Press the Arm or Disarm button once to activate the tag reader.
2.
You have five seconds to hold a tag in front of the tag reader. If the tag is recognized within this time, the control unit is armed or disarmed.
Caution:
If there are system errors available in the control unit when the system is armed, repeat the arming process within 10 seconds, as otherwise the system remains disarmed! Alternatively, you can activate the menu item “Forced arming”.
Factory settings:
1.
Open the housing. Remove the batteries, and then press any button to discharge the remaining power.
2.
Set switch 2 to ON, reinsert the batteries. The tag reader signals the reset
(including the added tags) with an audio signal followed by two more signals. The
Status LED starts flashing. Set switch 2 to OFF again and close the housing.
3.
Delete the tag reader from the sensor list of the control unit.
123
advertisement
Key Features
- Easy to use interface
- Remote access with LUPUSEC app
- Expandable system with a variety of sensors and cameras
- Motion detection
- Door/window sensors
- Smoke and heat detectors
- Panic button
- Built-in siren
- Tamper protection
- Battery backup
Related manuals
Frequently Answers and Questions
How do I set up the LUPUSEC-XT1?
Can I add additional sensors or detectors to my LUPUSEC-XT1?
What is the range of the LUPUSEC-XT1's wireless sensors?
advertisement
Table of contents
- 4 Introduction
- 4 Disclaimer
- 6 Important safety information
- 6 If you detect defects
- 7 Intended use
- 8 Hardware description
- 9 Scope of delivery
- 10 Put the LUPUSEC-XT1 into operation
- 10 Control unit
- 10 Place of installation
- 11 Install the control unit
- 11 Connect the control unit
- 13 Access to the main interface of the LUPUSEC-XT
- 15 Menu description
- 15 Home menu
- 15 Overview
- 17 History
- 18 Captured events
- 19 Time frame
- 19 PIN codes
- 21 Control unit menu
- 21 Status
- 22 Settings
- 25 Siren
- 26 Date & Time
- 27 Sensors menu
- 28 Sensors settings
- 31 Range
- 31 Bypass
- 32 Devices
- 34 Wireless sockets (PSS)
- 35 Network menu
- 35 Settings
- 38 Cameras
- 40 Settings menu
- 40 Contact ID
- 41 Contact ID Syntax
- 42 Special codes
- 43 Text message report
- 47 E-mail
- 49 Upload
- 50 Automation
- 52 System menu
- 52 Admin
- 53 Firmware
- 53 Default settings
- 54 Log files
- 55 Remote access via the internet
- 57 Create Dynamic DNS account
- 62 Access via the LUPUSEC app (Android + iOS)
- 63 Profile list
- 64 Main menu
- 65 Navigation within the app
- 66 Mobile phone access via the mobile web interface
- 68 The user interface of the LUPUSEC-XT1 mobile app
- 71 Description of sensors and controls
- 72 XT Keypad
- 73 Put the keypad into operation
- 75 Window/door contact
- 76 Put the window/door contact into operation
- 77 Wireless indoor siren
- 77 Put the wireless indoor siren into operation
- 80 Wireless outdoor siren
- 80 Put the wireless outdoor siren into operation
- 83 Smoke detector
- 84 Put the smoke detector into operation
- 86 PIR motion detector
- 86 Put the PIR motion detector into operation
- 88 Water detector
- 88 Put the water detector into operation
- 89 Remote control
- 89 Put the remote control into operation
- 90 Medical emergency controller
- 90 Put the medical emergency controller into operation
- 91 Wireless sockets (PSS)
- 91 Put the wireless socket (with electric meter) into operation
- 92 Put the wireless socket (without electric meter) into operation
- 93 Glass breakage detector
- 93 Put the glass breakage detector into operation
- 95 PIR network camera
- 95 Put the PIR network camera into operation
- 98 Temperature sensor
- 98 Put the temperature sensor into operation
- 99 Wireless relay
- 99 Put the wireless relay into operation
- 101 Magnetic locking device
- 102 Install the magnetic locking device to the door and put it into operation
- 103 Mechanical locking device
- 104 Install the mechanical locking device to the door and put it into operation
- 106 Panic button
- 106 Put the panic button into operation
- 107 Wireless repeater
- 108 Connect the wireless repeater to the control unit
- 110 CO detector
- 110 Put the CO detector into operation
- 111 Heat detector
- 111 Put the heat detector into operation
- 113 Wireless sensor input
- 114 Put the wireless sensor input into operation
- 116 Wireless lock contact
- 116 Install the wireless lock contact to the door and put it into operation
- 118 In-wall relay with electric meter
- 118 Put the in-wall relay with electric meter into operation
- 119 In-wall relay without electric meter
- 119 Put the in-wall relay without electric meter into operation
- 121 Tag reader
- 122 Put the tag reader into operation
- 124 Two-way motion detector
- 126 Put the PIR/microwave motion detector into operation