advertisement
Code 39 Enable
Enables/disables the ability of the scanner to decode Code 39 labels.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH bar code.
CODE 39 = DISABLE
5-286
CODE 39 = ENABLE
Magellan
TM
2200VS/2200VS and 2300HS/2300HS
Code 39 Enable
Code 39 Start Stop Character Transmission
Enables/disables transmission of Code 39 start and stop characters.
This feature applies only when Code 39 Check Character Calculation
is enabled.
NOTE
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH bar code.
CODE 39 START STOP CHARACTER TRANSMISSION = DISABLE
Product Reference Guide
CODE 39 START STOP CHARACTER TRANSMISSION = ENABLE
5-287
Code 39 Check Character Calculation
Enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in label is treated as a data character.
If check calculation is disabled, the risk is increased that a misread can occur.
In particular, if you are using variable length stitching, it is important to use check character calculation to prevent misreads.
NOTE
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH bar code.
CODE 39 CHECK CHARACTER CALCULATION = DISABLE
5-288
CODE 39 CHECK CHARACTER CALCULATION = ENABLE
Magellan
TM
2200VS/2200VS and 2300HS/2300HS
Code 39 Enable
Code 39 Check Character Transmission
Enables/disables transmission of optional Code 39 check character.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH bar code.
CODE 39 CHECK CHARACTER TRANSMISSION = DISABLE
Product Reference Guide
CODE 39 CHECK CHARACTER TRANSMISSION = ENABLE
5-289
Code 39 Full ASCII
Enables/disables the ability of the scanner to translate to Code 39 full
ASCII labels.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH bar code.
CODE 39 FULL ASCII = DISABLE
5-290
CODE 39 FULL ASCII = ENABLE
Magellan
TM
2200VS/2200VS and 2300HS/2300HS
Code 39 Enable
Code 39 Label ID
This feature specifies a Code 39 label ID to be added to bar code data.
The programming feature, Label ID Control, designates whether the
Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
NOTE
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the keypad in
resent the desired Label ID characters; entered as two hex pairs. A
table containing the ASCII Character Set and their corresponding
Hex Values is available in the inside back cover of this manual.
ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned.
The selectable range for this option is any hex value from 00 to FF.
4. Complete the programming sequence by scanning the SWITCH bar code.
Product Reference Guide
SET CODE 39 LABEL ID
5-291
Code 39 Require Quiet Zones
When enabled, this feature requires that quiet zones (margins) be present for Code 39 labels. When disabled, quiet zones are optional.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH bar code.
CODE 39 REQUIRE QUIET ZONES = DISABLE
5-292
CODE 39 REQUIRE QUIET ZONES = ENABLE
Magellan
TM
2200VS/2200VS and 2300HS/2300HS
Code 39 Enable
Code 39 Length Control
NOTE
This feature specifies whether variable-length or fixed-length decoding will be set for Code 39.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH bar code.
You must now set the features
When using variable length stitching, it is important to enable
39 Check Character Calculation to prevent misreads.
CODE 39 LENGTH CONTROL = VARIABLE-LENGTH
Product Reference Guide
CODE 39 LENGTH CONTROL = FIXED-LENGTH
5-293
Code 39 Length 1
Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode (see
.
Length includes the barcode’s check and data characters.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET CODE 39 LENGTH 1 below. You’ll need to
cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the keypad in
resent the desired label length. The selectable range for this option is
01 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-50).
4. Complete the programming sequence by scanning the SWITCH bar code.
5-294
SET CODE 39 LENGTH 1
Magellan
TM
2200VS/2200VS and 2300HS/2300HS
Code 39 Enable
Code 39 Length 2
Length 2 is the maximum label length if in variable length mode, or the
second fixed length if in fixed length mode (see Code 39 Length Control
) .
Length includes the barcode’s check and data characters.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
SET CODE 39 LENGTH 2 below. You’ll need to
cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the keypad in
resent the desired fixed label length. A setting of 00 will ignore this length (only one fixed length), otherwise, the selectable range for this option is 01 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-50).
4. Complete the programming sequence by scanning the SWITCH bar code.
Product Reference Guide
SET CODE 39 LENGTH 2
5-295
Code 39 Correlation
This feature enables/disables character correlation for Code 39.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Complete the programming sequence by scanning the SWITCH bar code.
CODE 39 CORRELATION = DISABLE
5-296
CODE 39 CORRELATION = ENABLE
Magellan
TM
2200VS/2200VS and 2300HS/2300HS
Code 39 Enable
Code 39 Stitching
Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Complete the programming sequence by scanning the SWITCH bar code.
CODE 39 STITCHING = DISABLE
Product Reference Guide
CODE 39 STITCHING = ENABLE
5-297
Code 39 Minimum Reads
Specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as a good read.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan.
Complete the programming sequence by scanning the SWITCH bar code.
CODE 39 MINIMUM READS = 1
5-298
CODE 39 MINIMUM READS = 2
Magellan
TM
2200VS/2200VS and 2300HS/2300HS
Code 39 Enable
Code 39 Minimum Reads — continued
Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
CODE 39 MINIMUM READS = 3
Product Reference Guide
CODE 39 MINIMUM READS = 4
5-299
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 11 Introduction
- 11 Manual Overview
- 12 How to Use This Manual
- 13 Scanner Nomenclature
- 14 Connectors
- 15 Physical Parameters
- 15 Scanning
- 15 AC Adapter
- 16 Electrical Specifications
- 18 Laser and Product Safety
- 20 Labeling
- 22 Agency Compliances
- 23 Bar Codes Supported
- 23 Retail Codes
- 23 Industrial Codes
- 24 Dual Bar Codes for Japan (2 label read)
- 25 Site Preparation and Installation
- 25 Unpacking
- 26 Operational Verification
- 27 Installation: Model 2200VS
- 30 Installation: Model 2300HS
- 33 Operation and Maintenance
- 34 Scanning Items: Model 2200VS
- 35 Scanning Items: Model 2300HS
- 36 Operational Controls
- 36 Operational Modes
- 36 Power-Up/Selftest & Pre-Operation
- 37 Operating Mode
- 39 Additional Functions
- 39 Programming
- 39 Scanner Diagnostic Mode
- 40 Scanner Reset
- 40 Operational Maintenance
- 40 Cleaning
- 41 Problem Isolation
- 42 Diagnostic Procedures
- 43 Error Codes
- 44 Flowcharts
- 49 Programming
- 49 Introduction to Label Programming
- 49 Understanding the Basics
- 50 Integrating the Scanner With Your Host System
- 50 Customizing Your Scanner’s Operation
- 52 Programming Overview
- 52 Programming via Handheld Device
- 53 What Is Programming Mode?
- 53 Entering and Exiting Programming Mode.
- 54 Programming Session
- 58 LED and Beeper Indicators
- 58 If You Make a Mistake...
- 58 Return to Factory Settings
- 59 Test Mode
- 60 General Scanner Features
- 60 Scanner Button Options
- 62 Double Read Timeout
- 64 Laser Timeout
- 66 Motor Timeout
- 69 Label Gone Timeout
- 72 Auxiliary Port Mode
- 74 Auxiliary Port Baud Rate
- 78 Productivity Index Reporting (PIR)/Cashier Training (CT)
- 79 Indication Features
- 79 Green LED Idle State
- 80 Power-up Beep Control
- 81 Good Read Beep Control
- 82 Good Read Beep Frequency
- 84 Good Read Beep Length
- 85 Good Read Beep Volume
- 88 Good Read When to Indicate
- 90 EAS Features
- 90 EAS Active State
- 91 EAS Timeout
- 92 Interface Related Features
- 92 Interface Type
- 113 Maximum Host-Transmitted Message Length
- 114 Number of Host Transmission Buffers
- 115 AIM ID
- 117 Label ID Control
- 120 Global Prefix
- 122 Global Suffix
- 124 Case Conversion
- 126 IBM Features
- 126 IBM Interface Options
- 127 IBM Number of Host Resets
- 128 IBM Transmit Labels in Code 39 Format
- 129 IBM Label Slicing Control
- 130 IBM Maximum Label Slice Length
- 131 USB-OEM Scanner Device Type
- 132 RS-232 Features
- 132 RS-232 Baud Rate
- 136 RS-232 Number of Data Bits
- 137 RS-232 Number of Stop Bits
- 138 RS-232 Parity
- 140 RS-232 Hardware Control
- 143 RS-232 Intercharacter Delay
- 144 RS-232 Software Flow Control
- 145 RS-232 Host Echo
- 146 RS-232 Host Echo Quiet Interval
- 147 RS-232 Ignore Host Commands
- 148 RS-232 TTL
- 149 RS-232 TTL Invert
- 150 RS-232 ICL DC1 Character Delay Enable
- 151 RS-232 Beep on ASCII BEL
- 152 RS-232 Beep on Not on File
- 153 RS-232 ACK NAK Enable
- 155 RS-232 ACK Character
- 156 RS-232 NAK Character
- 157 RS-232 Retry on ACK NAK Timeout
- 158 RS-232 ACK NAK Timeout Value
- 159 RS-232 ACK NAK Retry Count
- 160 RS-232 ACK NAK Error Handling
- 162 RS-232 Indicate Transmission Failure
- 163 Single Cable RS-232 Options
- 164 Single Cable Pacesetter Plus Enable
- 165 Single Cable RS-232 RTS CTS Selection
- 168 Single Cable RS-232 Use BCC
- 169 Single Cable RS-232 Use ACK/NAK
- 170 Single Cable RS-232 Use STX
- 171 Set Single Cable RS-232 STX Character
- 172 Set Single Cable RS-232 ETX Character
- 173 Keyboard Wedge/USB Keyboard Features
- 173 Keyboard Interface — Keyboard Layout
- 182 Keyboard Interface Quiet Interval
- 183 Keyboard Interface Caps Lock State
- 185 Keyboard Interface — Keyboard Simulation
- 186 Keyboard Interface — Control Characters
- 188 Keyboard Interface — Intercharacter Delay
- 189 Symbology Programming
- 189 Coupon Control
- 191 UPC-A Enable
- 192 UPC-A Number System Character Transmission
- 193 UPC-A Check Character Transmission
- 194 Expand UPC-A to EAN-13
- 195 UPC-A Label ID
- 196 UPC-A 2-Digit Supplemental Label ID
- 197 UPC-A 5-Digit Supplemental Label ID
- 198 UPC-A 128 Supplemental Label ID
- 199 UPC-A Minimum Reads
- 201 UPC-E Enable
- 202 UPC-E Number System Character Transmission
- 203 UPC-E Check Character Transmission
- 204 Expand UPC-E to UPC-A
- 205 Expand UPC-E to EAN-13
- 206 UPC-E Label ID
- 207 UPC-E 2-Digit Supplemental Label ID
- 208 UPC-E 5-Digit Supplemental Label ID
- 209 UPC-E 128 Supplemental Label ID
- 210 UPC-E Minimum Reads
- 212 EAN-13 Enable
- 213 EAN-13 First Character Transmission
- 214 EAN-13 Check Character Transmission
- 215 EAN-13 ISBN Conversion Enable
- 216 EAN 13 Label ID
- 217 EAN-13 2-Digit Supplemental Label ID
- 218 EAN-13 5-Digit Supplemental Label ID
- 219 EAN-13 128 Supplemental Label ID
- 220 EAN-13 Minimum Reads
- 222 Bookland Label ID
- 223 EAN-8 Enable
- 224 EAN-8 Check Character Transmission
- 225 Expand EAN-8 to EAN-13
- 226 EAN-8/JAN-8 Guard Insertion
- 227 EAN-8/JAN-8 Guard Substitution
- 228 EAN-8/JAN-8 Both Guards Substitution
- 229 EAN-8 Stitch Exact Label Halves
- 230 EAN-8 Stitch Unlike Label Halves
- 231 EAN 8 Label ID
- 232 EAN-8 2-Digit Supplemental Label ID
- 233 EAN-8 5-Digit Supplemental Label ID
- 234 EAN-8 128 Supplemental Label ID
- 235 EAN-8 Decoding Levels
- 238 EAN-8 Minimum Reads
- 240 EAN-8 Minimum Segment Length
- 246 Other UPC/EAN Options
- 247 Price Weight Check
- 250 In-Store Label Minimum Reads
- 252 Enable EAN Two Label
- 253 EAN Two Label Combined Transmission
- 254 UPC/EAN Guard Insertion
- 255 UPC/EAN Stitch Exact Label Halves
- 256 UPC/EAN Stitch Unlike Label Halves
- 257 UPC/EAN Character Reconstruction
- 258 EAN Two Label Minimum Reads
- 260 UPC/EAN Correlation
- 261 UPC/EAN Minimum Segment Length
- 267 Addons
- 271 Addon Timer
- 272 2-Digit Add-ons Minimum Reads
- 274 5-Digit Add-ons Minimum Reads
- 276 Code 128 Add-ons Minimum Reads
- 278 GTIN Enable
- 279 GTIN Label ID
- 280 GTIN 2-Digit Supplemental Label ID
- 281 GTIN 5-Digit Supplemental Label ID
- 282 GTIN Code 128 Supplemental Label ID
- 283 DataBar Omnidirectional Enable
- 284 DataBar Omnidirectional/EAN-128 Emulation
- 285 DataBar Omnidirectional Label ID
- 286 DataBar Omnidirectional Minimum Reads
- 288 DataBar Expanded Enable
- 289 DataBar Expanded EAN-128 Emulation
- 290 DataBar Expanded Label ID
- 291 DataBar Expanded Length Control
- 292 DataBar Expanded Length 1
- 293 DataBar Expanded Length 2
- 294 DataBar Expanded Minimum Reads
- 296 Code 39 Enable
- 297 Code 39 Start Stop Character Transmission
- 298 Code 39 Check Character Calculation
- 299 Code 39 Check Character Transmission
- 300 Code 39 Full ASCII
- 301 Code 39 Label ID
- 302 Code 39 Require Quiet Zones
- 303 Code 39 Length Control
- 304 Code 39 Length 1
- 305 Code 39 Length 2
- 306 Code 39 Correlation
- 307 Code 39 Stitching
- 308 Code 39 Minimum Reads
- 310 Pharmacode 39 Enable
- 311 Pharmacode 39 Start Stop Character Transmission
- 312 Pharmacode 39 Check Character Transmission
- 313 Pharmacode 39 Label ID
- 314 Code 128 Enable
- 315 Code 128 Transmit Function Characters
- 316 Convert Code 128 to Code 39
- 317 Code 128 Label ID
- 318 Code 128 Length Control
- 319 Code 128 Length 1
- 320 Code 128 Length 2
- 321 Code 128 Correlation
- 322 Code 128 Stitching
- 323 Code 128 Minimum Reads
- 325 EAN-128 Enable
- 326 EAN-128 Label ID
- 327 Interleaved 2 of 5 (I 2 of 5) Enable
- 328 I 2 of 5 Check Character Calculation
- 329 I 2 of 5 Check Character Transmission
- 330 I 2 of 5 Label ID
- 331 I 2 of 5 Length Control
- 332 I 2 of 5 Length 1
- 333 I 2 of 5 Length 2
- 334 I 2 of 5 Correlation
- 335 I 2 of 5 Stitching
- 336 I 2 of 5 Minimum Reads
- 338 Standard 2 of 5 (Std 2 of 5) Enable
- 339 Standard 2 of 5 Check Character Calculation
- 340 Standard 2 of 5 Check Character Transmission
- 341 Standard 2 of 5 Label ID
- 342 Standard 2 of 5 Length Control
- 343 Standard 2 of 5 Length 1
- 344 Standard 2 of 5 Length 2
- 345 Standard 2 of 5 Correlation
- 346 Standard 2 of 5 Stitching
- 347 Standard 2 of 5 Minimum Reads
- 349 Codabar Enable
- 350 Codabar Start Stop Character Transmission
- 351 Codabar Start Stop Character Set
- 353 Codabar Start Stop Character Match
- 354 Codabar Check Character Calculation
- 355 Codabar Check Character Transmission
- 356 Codabar Label ID
- 357 Codabar Require Quiet Zones
- 358 Codabar Length Control
- 359 Codabar Length 1
- 360 Codabar Length 2
- 361 Codabar Correlation
- 362 Codabar Stitching
- 363 Codabar Minimum Reads
- 365 Code 93 Enable
- 366 Code 93 Label ID
- 367 Code 93 Length Control
- 368 Code 93 Length 1
- 369 Code 93 Length 2
- 370 Code 93 Correlation
- 371 Code 93 Stitching
- 372 Code 93 Minimum Reads
- 374 MSI/Plessey Enable
- 375 MSI/Plessey Check Character Calculation
- 376 MSI/Plessey Number of Check Characters
- 377 MSI/Plessey Check Character Transmission
- 378 MSI/Plessey Label ID
- 379 MSI/Plessey Length Control
- 380 MSI/Plessey Length 1
- 381 MSI/Plessey Length 2
- 382 MSI/Plessey Correlation
- 383 MSI/Plessey Stitching
- 384 MSI/Plessey Minimum Reads
- 387 LED/Beeper Indications & Controls
- 388 Volume/Tone Push Button
- 389 Green LED Indicator
- 391 Cable Information
- 393 Keypad
- 401 Host Commands
- 403 Handheld Data Format Requirements
- 403 Handheld Data Format Requirements General
- 404 Datalogic Handheld Data Format Requirements
- 412 AIM Formats
- 419 Keyboard Function Key Mappings
- 419 Keyboard Model Cross Reference