BusLogic BT-XlO A IDE caching User's Guide
Annonce
Annonce
BusLogic I n c .
4151 Burton Drive
Santa Clara, CA 95054
P / N 3 0 0 2 4 0 3 REV.Al
User’s Guide
R
E V I S I O N
H
I S T O R Y
Revision
A
Change Activity
Release
Date
12/l 7193
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations.
C
O P Y R I G H T
0 Copyright 1993 BusLogic Inc. All rights reserved.
BusLogic Inc makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. BusLogic is not liable for any errors contained herein or incidental or consequential damages in connection with furnishing, performance or use of this material.
This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without prior written consent of BusLogic Inc.
T
R A D E M A R K S
VESA and VL-Bus are trademarks of the Video Electronics Standards
Association. Novell and NetWare are trademarks of Novell, Inc. MS-DOS and Windows are trademarks of the Microsoft Corporation. SC0 is a trademark of Santa Cruz Operation Inc. UNIX is a trademark of AT&T Bell
Lab. OS/2 is a trademark of IBM. AutoIDE is a trademark of BusLogic Inc.
(Other trademarks shown are the property of their respective owners.)
Section 1: Introduction
Onboard Configuration.. ................................................................. l - l
Power Efficient Operation ............................................................. .1-2
Support for 4 Drives ....................................................................... .1-3
Driver Support.................................................................................. l-3
Specifications ................................................................................... .1-3
Reference Documents ...................................................................... 1-5
Hardware Requirements ................................................................ .1-5
Software Requirements ................................................................... 1-5
Section 2: Configuration Options
Hardware Configuration Options ................................................. 2-1
Hard Drive LED Connector (JPl) ........................................... 2-2
Mirroring Beeper (JP2) ............................................................ .2-2
INT & I/O Jumpers (for BT-910A only) (JP3) ...................... .2-3
Damping Resistor Bypass Jumpers (JDRO and JDRl) .........2- 4
Cache DRAM Installation .............................................................. .2-5
Section 3: Installation
Unpacking and Inspection ............................................................. .3-l
Installation Tools .............................................................................. 3-1
Pre-Installation Notes ...................................................................... 3-4
Model BT-XlOA Installation .......................................................... .3-5
CMOS Updates for New IDE Drives.. .......................................... .3-6
System Power Up ............................................................................ .3-7
ROM Address Conflicts .......................................................... .3-8
Drive Parameters ...................................................................... 3-8
T
A B L E O F
C
O N T E N T S
,
C O N T I N U E D
Section 4: The AutolDE Utility
Disk Parameter Setup ..................................................................... .4-2
Physical Drive Information .................................................... .4-3
Logical Drive Information ...................................................... .4-3
Setting Attributes ..................................................................... .4-4
Track-Remap ............................................................................ .4-6
Installed Drive Information .................................................... .4-7
Controller Option Select.. ............................................................... .4-7
Cache Line Size.. ....................................................................... .4-8
More Than 2 Drives ................................................................. .4-B
INT13 BIOS Selection .............................................................. .4-S
Cache Function ......................................................................... .4-9
Controller I/O Port.. ................................................................ .4-9
Floppy Controller (BT-410A and BT510A only) ............... .4-10
ROM BIOS Address ............................................................... .4-10
Green Cache Mode (Power Saving Mode) ......................... .4-10
Display Drive Information.. ......................................................... .4-11
Low Level Format ......................................................................... .4-12
Mirror Initialization or Repair.. ................................................... .4-12
Mirror Drive Verification .............................................................. 4-14
Disk Image Copy.. ......................................................................... .4-15
Disk Image Compare .................................................................... .4-15
Section 5: Driver Installations
WINDOWS 3.1X ....................................................................... .5-l
NETWARE 4.0X ....................................................................... .5-2
NETWARE.3.1X ....................................................................... .5-2
NETWARE.3.1 .......................................................................... .5-2
NETWARE 2.XX ....................................................................... .5-4
OS/2 v2.x ................................................................................. .5-4
UNIX .......................................................................................... .5-4
Appendix A: AT Hard Drive Types
Appendix 6: Error Messages and General Troubleshooting Tips
T
A B
L
E OF
C
O N T E N T S
,
C O N T I N U E D
List of Figures
2-l. JP3 Interrupt and I/O Selector.. .............................................. 2-3
2-2. JDRO and JDRl Jumper@ ...................................................... 2-4
3-1. Quick Installation Reference ................................................... 3-2
3-2. Model BT-410A Caching Controller ...................................... 3-3
3-3. Model BT510A Caching Controller ...................................... 3-3
3-4. Model BT-910A Caching Controller ..................................... .3-4
List of Tables l-l. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The BusLogic IDE Caching Controllers, herein referred to as BT-XlOA, significantly boost IDE hard drive performance by offering high speed caching to relieve the bottleneck between a high speed I/O bus interface and your slower IDE disk subsystems. Data requests are first directed to the controller’s onboard memory (Random Access Memory (RAM)) where the most frequently used data is stored. Hardware delays are reduced since the hard drive (HDD) isn’t accessed if the data is already in RAM.
The BT-XlOA supports up to four IDE drives. Two controller cards can be installed, for a total per system support of eight drives. Three versions are available including the BT410A for Video Electronics Standard Association (VESA) platforms, the BT-510A for Industry Standard Architecture
(ISA) systems and the BT-910A for Peripheral Component Interconnect
(PCI) bus architectures. The BT410A and BT510A also include support for floppy drives.
Onboard memory, expandable from 512KB to 16MB, is available through
SIMM memory modules.
ONBOARD C
O N F I G U R A T I O N
While designed for “plug-and-play” installation and operation, the BT-
XlOA also provides tools to further configure the controller and the drives attached to it, including: n
Disk mirroring. This option lets you set up two drives so that both always contain identical information. When enabled, the controller writes to both hard disks at the same time while your system is running. The system sees both drives as one logical drive and the
Introduction I 1-l
space available is always the capacity of the smaller of the pair of drives. Its operation is transparent to both the user and operating system. The maximum is two mirrored pairs per controller.
Linked drives. This feature lets you designate two HDDs as one logical drive whose capacity is the total of both hard drives. The maximum is two linked pairs per controller.
Mirroring and linking are configured using the BT-XlOA’s onboard menudriven AutoIDETM configuration utility. You can also use the AutoIDE to do the following:
Enable track-remapping for >528MB drive support under DOS environment
Access power saving and drive support options, cache line size, and other settings for the controller
Display drive information such as drive model, firmware version, serial number, and so forth
Perform low level formats
Initialize/repair mirroring pair drives
Verify that the mirroring pair has identical data
Copy and compare disk data from the source disk to the target disk
P
O W E R
E
FFICIENT
O
P E R A T I O N
The IDE Caching Controller also offers efficient system operation for both the IDE drive(s) and the board itself. When the board is idle, i.e., there is no access activity to the storage subsystem, the clock signal generated by the on-board processor is turned off automatically, forcing the remaining power-consuming components into the sleeping states. The resulting power saving is significant.
An option of the AutoIDE, Motor Off, configures the controller to turn off the IDE drive’s motor after a specific period of idle time. Refer to Green
Cache Mode in the AutoIDE’s Controller Option Select module (Section 4) for details.
I-2 I BT-XIOA IDE
Caching Controller
S
UPPORT FOR
4 D
R I V E S
The
IDE Caching Controller supports up to four independent drives, i.e., physical drives C:, D:, E:, and F:. Any of these drives can be designated the boot drive. If two controllers are installed, one as primary and the other as secondary, you can control up to eight individual drives. Refer to More
Than 2 Drives option in the AutoIDE’s Controller Option Select module
(Section 4) for details.
D
RIVER
S
U P P O R T
The
BT-XlOA offers driver support for: n
MS-DOS or PC-DOS n
Windows w OS/2 n
NetWare n
SC0 UNIX
These drivers also support installation of two BT-XlOA controllers and work with a maximum of four drives per controller. Please check the
README in the Novell driver diskette for further details. Depending on the product purchased, not all drivers listed are included.
S
P E C I F I C A T I O N S
Refer to table 1-l for a summary of the physical and electrical specifications.
Table l-l. Specifications
Performance
Hardware disk mirroring support for all operating systems
Green Cache: power saving support for both controller and drive(s)
Effective disk seek time: < 0.3 msec
Maximum DTR (Disk-to-Cache): 5MB/sec
Maximum DTR (ISA Bus-to-Cache): 5MB/sec
Sustained DTR (CoreTest):
BT-51 OA: 2.6MB/sec
BT-41 OA:
1 SMB/sec (50MHz)
BT-91 OA:
12MB/sec (33MHz)
Cache memory hit ratio: cache memory dependent
Introduction I 1-3
Table l-1. Specifications (continued)
Technical
Microprocessor: 8OC286 (BT-51 OA, BT-41 OA and BT-91 OA)
Bus standard: 16-bit ISA Bus (BT-510A); 32-bit Bus (VL: BT-41 OA, PCI: BT-91 OA)
Cache DRAM: 80ns (or faster) 256KB/l MB/4MB SlMMs and can be mixed
Flexible cache expandability: from 512KB to 16MB
Maximum I/O bus speed: 12MHz (BT-510A); 25-50MHz (BT-41 OA: same as motherboard clock); 33MHz (BT-9lOA)
Maximum 4 IDE drives for each controller; maximum two controllers
Maximum 4GB capacity per drive
Maximum floppy drives supported: 2 (for BT-41 OA and BT-51 OA only)
ROM addressing: on-screen selectable
Functional
Auto drive parameter scanning make plug-and-play installation possible
Compatible with all major operating systems and 32-bit driver support
WD-1003 emulation mode support
Booting drive can be switched among multiple drives controlled
by your controller
Track-remapping support for drive capacity over 528MB under DOS environment
Enhanced INT 13 BIOS relocation
Track remapping and automatic type table creation
Caching algorithms: fully associated LRU, automatic read ahead, deferred write back, and elevated seeking
Direct replacement for standard AT Bus interface card without reformatting the drive(s)
R
E F E R E N C E
D
O C U M E N T S
To install the BT-XlOA you should have the following documents in addition to this installation guide: n n
Operating system installation and user’s guide
The system’s installation and set-up guide
H
A R D W A R E
R
E Q U I R E M E N T S
While you can install up to two IDE Cache Controllers, the following list assumes you are installing one controller in your host system: n n
One
available 16-bit expansion slot in your host system
DC power for an internal 3.5” or 5.25” IDE drive n
An
IDE hard drive n
One
40-pin and 34-pin ribbon cable to connect internal IDE and floppy (BT-410A and BT-510A only) drives
S
O F T W A R E
R
E Q U I R E M E N T S
For full 32-bit addressing with the BT-410A and BT-910A, you will need the enclosed diskette which includes operating system device drivers for installation. No drivers are required for BT-510A installation and use under
DOS. However, depending on your configuration of the BT-510A, drivers may be required for other operating systems.
Introduction
I l-5
1-4 I ET-XlOA IDE Caching Controller
l-6 I BT-XlOA IDE Caching Controller
C
ONFIGURATION
O
PTIONS
Installing the IDE Caching Controller involves the following steps:
Performing optional jumpering
Installing memory SIMMs for caching
Installing the board into the host system
Selecting the correct cables and making the cabling connections
Making configuration changes to the host system, if needed, so that the system recognizes the new controller and any new drives you may install
Performing optional controller configuration via the AutoIDE utility
This section describes options that are configured before you can install your controller card, including board jumpering options and memory requirements.
H
A R D W A R E
C
O N F I G U R A T I O N
O
P T I O N S
The IDE Caching Controller offers the following hardware configuration options:
A hard drive LED connector
A warning beeper if a mirroring error occurs
INT and I/O Jumpers (for BT-910A only) (‘JP3)
Damping resistor bypass in case of hard drive incompatibility
Configuration Options I 2-1
Hard Drive LED Connector (JPl)
The BT-XlOA allows you to see hard disk activity via an LED in the front panel of your system. It also flashes diagnostic codes right after power-up.
For this option connect the LED cable to JPl. See the board layout illustrations in Section 3 to locate this jumper. Refer to your system’s documentation to locate and unplug the LED cable from the connector on the system board.
The following shows the flash frequency of each fatal error condition:
One short flash
Two short flashes
Three short flashes
Four short flashes
No Cache DRAM installed
CPU error
SRAM error
Timer error
The BT-XlOA supports write buck mode to achieve the best performance for a caching controller. It only writes modified cache data back to disk when the system is idle, or when a cache read request misses and it becomes necessary to flush the modified cache line buffers to make room for new data. Write back mode results in superior cache performance because it permits the caching controller to combine and sort write operations prior to updating the disk, and because the updating is done in the background when the system is idle or the write time threshold is reached.
Caution: Due to the nature of write back, you must be careful when powering down: do not power down the system while this LED is still active. Doing so may result in loss of data as the contents of the cache buffer have not been completely written to the disk.
Mirroring Beeper (JP2)
JP2 is used to issue a warning beep through a speaker when an error occurs during the disk mirroring process. It can be connected to the speaker in the front panel of your system or to another speaker complying with the same specification as the system’s speaker. See the board layout illustrations in
Section 3 to locate this connector.
2-2 I BT-XIOA IDE Caching Controller
INT & l/O Jumpers (for BT-91OA only) (JP3)
Pins 1 through 4 of JP3 are used to select one of the four PC1 interrupt channels located at INT A#, B#, C#, or D##. Pin 5 of JP3 specifies the I/O port address, Primary or Secondary of the BT-910A. Note that if the primary port is chosen, the BT-910A will interrupt the host via IRQ14. If the secondary port is selected, it will interrupt the host via IRQ15. Hence the selected PC1 interrupt channels, INT A#, I3#/, C#, or D#must be routed to IRQ14 or IRQ15 accordingly on the motherboard.
1 2 3 4 5
JP3
L_ ,NT 1 VOADDR
Pin 1 selects INT A# (default
-
installed)
Pin 2 selects INT B#
Pin 3 selects INT C#
Pin 4 selects INT D#
Pin 5 (installed) = Primary (IRQ14)
Pin 5 (removed) = Secondary (IRQ15)
Figure 2-1. JP3 Interrupt and I/O Selector
Since
different motherboards may have different jumper arrays corresponding to INT A# - D#, check the motherboard manual before selecting the desired option. Based upon the status of BT-910A’s Controller I/O Port, choose the INT option that maps to the desired IDE IRQ Channel in the jumper array for your motherboard.
0
0
1
Pin 1
0
1 = jumper installed
1
0
Pin 2
0
0
1
Pin 3
0
0
0
1
0
Pin 4
0
0
0 = jumper removed
INT ?#
INT A# l
INT B#
INT C#
INT D#
* = default
Configuration Options I 2-3
Note that the jumper setting for Pin l-4/ JP3 should match the INT Selection in the AutoIDE’s Controller Option Select module.
Pin 5
0*
1
IDE IRQ Channel
14
15
Controller
I/O Port
Primary
Secondary
Port Address lFO- lF7
170- 177
0 = jumper installed 1 = jumper removed
* = default
Pin 5/JP3 selects the board’s I/O port. When two controllers are installed, use this option to indicate which card is the primary and which serves as the secondary controller. Note that the jumper setting for Pin 5/JP3 should match the value for the Controller I/O Port option in the AutoIDE’s
Controller Option Select module.
Damping Resistor Bypass Jumpers (JDRO and JDRl)
JDRO and JDRl are used to short (place a connector over the jumper) the resistors associated with the first and secondary IDE bus, respectively.
These two jumpers are used to avoid possible hard drive (HDD) incompatibility due to different noise filter implementations in assorted HDDs. The default setting, jumper removed, is suitable for most HDDs.
JDRO JDRI
Jumper
JDRO if HDD filtering is required for primary I/O address
Jumper JDRl if HDD filtering is required for secondary I/O address
Figure 2-2. JDRO and JDRl Jumpering
C
ACHE
DRAM
I
NSTALLATION
The BT-XlOA uses Dynamic Random Access Memory (DRAM) in the form of SIMMs for its cache operation. You must install at least one pair of SIMMs for caching.
The BT-XlOA has four SIMM sockets, arranged in two separate banks. You must install 256KB/lMB/4MB f&t page mode SIMMs, with a minimum rated access of 8Ons or faster. These can be mixed in any combination, however, two SIMMs installed in the same bank must be the same size and speed. Bank0 must be installed with DRAM for proper operation and
Bank1 is optional.
SIMM specification: 256KB/l MB/4MB fast page
mode 80ns or faster
BankO: (256KB x 2)/(1 MB x 2) /(4MB x 2)
Bank1
:
(OMB x 2)/(256KB x 2)/(1 MB x 2)/(4MB x 2)
2-4 I ET-XlOA IDE Caching Controller
Configuration Options I 2-5
2-6
I
ET-XlOA IDE Caching Controller
INSTALLATION
This section describes unpacking guidelines, installation tools, controller installation, related configuration requirements and troubleshooting for first-time power up.
U
N P A C K I N G A N D
I
N S P E C T I O N
Before handling the BT-XlOA, take precautions to avoid damage from electrostatic discharge: either use a grounding strap, or, touch your computer on a metal part to discharge static electricity before handling the board. Always hold the board by the edges, even after static electricity is discharged.
Remove the BT-XlOA from its protective envelope. Check that your shipment is complete with cables, documentation and diskette. Then verify that no physical damage occurred during shipping by inspecting the board for bent pins, loose parts, broken traces, and chipped or broken connectors.
I
NSTALLATION
T
O O L S
The following items may be needed to assist with installing the card into your system:
Your host system hardware manuals
Hard disk drive(s) manuals
Floppy disk drive(s) manuals
Small screwdriver
Small needle-nosed pliers
Installation I 3-i
40-pin
IDE cable* connection
On-board
CPU
Jumper on selects
IRQ14 -
(default, shown)
Nojumperselects IRQ15
Minimum installation
SIMMS in Bank0 for caching l
Pin 1 indicated by colored stripe on cable
Speaker LED cable cable connection connection
Figure 3-4. Model BT-91OA Caching Controller
PREINSTALLATION N
O T E S
If you are upgrading an existing IDE hard drive subsystem, it is advisable to do a complete file-by-file (as opposed to image) backup of your data to removable media.
The BT-XlOA requires a specific bus slot, depending on which model you purchased, and, for most installations, can be treated as a direct replacement for an IDE hard bus controller (or “paddleboard”). If another IDE bus controller is to coexist with the BT-XlOA, then these two controllers must be set as primary and secondary, respectively (refer to the AutoIDE’s Controller I/O Port module description in Section 4). Also, only one of the two controllers can enable its floppy; the other one must be disabled or removed. If another IDE adapter is installed, you have to set the BT-XlOA’s
ROM address prior to that of the IDE adapter.
3-4 I
ET-XiOA IDE Caching Controller
*
M
ODEL
BT=Xl OA I
N S T A L L A T I O N
1.
2.
Before you install the controller card, install the SIMMs for cache memory.
For the BT-910A, set JP3 to select the correct interrupt and I/O port address values for this card. See Section 2 for details on these hardware configuration options.
Power down the host system.
Referring to the host system owner’s manual, open the case to gain access to the motherboard and expansion slots. If the computer has been on, wait a few minutes until the power supply case has cooled down inside the computer. If the power supply case is cold, touch it to discharge any static electricity that may be on your clothes or body. If a disk drive controller board is installed, remove all connecting cables to the board and then lift it out of the host computer.
3.
4.
Remove the mounting screw and the existing bracket from the rear panel behind the slot that has been selected for insertion of the BT-
XlOA.
Press the BT-XlOA downward into the selected slot, align the mounting bracket, and reinstall the mounting screw.
Caution:
Make sure that the board is properly seated in the slot.
5.
BT-410A/BT-5ZOA Only: Connect the 34-pin flat cable to CN3 by aligning its colored edge (usually red) with Pin 1 of CN3. Connect the other end to the floppy disk drive.
AZZ Models: If you are attaching a single new or used IDE drive to the
BT-XlOA, connect the drive to the IDE BUS1 connector, CNl, on the
BT-XlOA using either an existing or the supplied 40-pin data/control cable.
If you are attaching two or more IDE drives to the BT-XlOA, see the following rules before continuing. Also refer to the advanced installation instructions in Section 4 for further details regarding mirroring and linking configurations.
Installation I 3-5
n n n
Two drives can be connected to each channel
If mirroring is desired, each drive must be on a separate channel
If linking is desired, each drive must be on the same channel
Note: After physical installation, you must turn on mirroring and linking via the
AutolDE’s Disk Parameter Setup module (Section 4).
7.
Insert the four-pin header connector from the drive activity LED on the front panel of the host to connector JP1 on the BT-XlOA. In most cases, this connector is reversible and may be plugged into JPl in either direction. See your system user’s guide for more information.
8.
Insert the connector from the system speaker to connector JP2 on the
BT-XlOA.
Verify that all connections are secure.
9.
10.
Reattach and close the cover of the host computer as described in the system owner’s manual.
11.
Before powering up the system, read “CMOS Updates for New IDE
Drives” (below) to determine if you need to update your system’s
CMOS configuration.
C M O S U
P D A T E S F O R
N
E W
IDE D
R I V E S
If you are installing one or more new IDE drives, update your system’s
CMOS so that it can recognize the new devices as follows:
If you are installing a single new IDE drive for the first time, it is necessary to configure Drive C: in the system CMOS Setup to type 1.
This enables the system to detect the BT-XlOA, where the actual drive parameter tables are stored.
When two drives linked or mirrored as a pair are seen as a logical drive, set Drive C: to type 1 for proper operation.
If two individual drives or link/mirror pairs are installed, you have to set both Drive C: and D: to type 1.
.
.
3-6 I BT-XlOA IDE Caching Controller n
If more than two individual drives are installed, or more than two link/mirror pairs are installed, the drive types of Drive C: and D: will be ignored and handled by the controller. Refer to More than 2 Drives option in the Controller Option Select module for details.
The following summarizes CMOS configuration. Note that a link/mirror pair is treated as a single drive.
#
of Drive(s)
1
2
3
4
X = don’t care
System CMOS/Drive Type
(Drive C:,D:)
1, Non-installed
191
X, X
X, X
* = See “Controller Option Select” module
More_Than_P_Drives
Support (*)
Disabled
Disabled
Enabled
Enabled
If necessary, refer to your motherboard or system manual for further instructions on configuring the system CMOS. Also, refer to Appendix A,
“AT Hard Drive Types,” for a list of drive types to ensure that you’ve correctly configured the CMOS Setup Drive Table for your drive type. If you are upgrading an existing IDE drive subsystem, the values previously stored in the system CMOS are unlikely to require modification.
S
Y S T E M
P
O W E R
U
P
For most single new or used IDE drive installations, no additional steps are necessary to ensure proper operation of the BT-XlOA with your disk subsystem. Power up the system and ensure that the system POST (Power
On Self-Test) is functioning properly. The BT-XlOA should display its own
POST test and messages immediately below and after the system POST test.
A sample screen is depicted below.
Primary xxx-Bus IDE Caching Controller
BusLogic, Inc. (Vx.xx)
Installation
I
3-7
Press F2 or F6 to enter AutolDE configuration utility.
4096K bytes of CACHE DRAM installed
ROM Address Conflicts
If the BT-XlOA POST test and messages do not appear, there may be a ROM address or timing conflict between the BT-XlOA and other adapter cards in the system. Re-check the ROM address set for the BT-XlOA (see the ROM
BIOS Address option on the Controller Option Select display) against the
ROM address of any other adapter cards in the system for potential conflicts. If a conflict exists, adjust the ROM address of other card(s).
Otherwise, turn the power off, pull out the other card(s), and then power up the system and enter the AutoIDE configuration menu to select a proper location to avoid the conflict.
If the system contains a 16-bit VGA adapter with a Fast Address Decode option, disable that feature. Due to its wider address decoding range, this feature might cause some potential conflicts with the BT-XlOA or any other cards implemented with &bit memory mapped I/O.
Drive Parameters
For most single new or used IDE drive installations, there is generally no need to access the AutoIDE configuration utility to ensure proper operation of the BT-XlOA with your IDE drive. The BT-XlOA obtains the correct drive parameters directly from the drive itself, by automatically issuing an IDE
Identify Drive command. If you are upgrading a single existing IDE drive subsystem with the BT-XlOA, the drive will function exactly as before. If you are installing a new IDE drive, the drive is now ready for operating system installation; refer to your operating system manual for further instructions.
Note: IDE drives arefactoy low-levelformatted. It is unnecessa y and inadvis-
able to low-level format a new IDE drive.
Some IDE drives either do not respond correctly to the IDE Identity Drive command, or respond with the physical parameters, rather than the manufacturer’s recommended translation parameters. In such cases, the
BT-XlOA will issue an error message similar to the one shown below.
4
IDE BUS1 drive 0: Bad drive or drive parameter error!
AutolDE configuration menu to reconfigure the system.
If you see this message, use AutoIDE to manually enter the correct drive parameters in the Disk Parameter Setup module. Refer to your drive manual for the correct parameters for a new IDE drive. If you are upgrading an existing used IDE drive subsystem, the drive parameters previously stored in the system CMOS will be correct.
Once you have entered the correct drive parameters using the Disk Parameter Setup module (Section 4), press cEso and save the updated parameters.
The system will reboot and the new parameters will be checked by the BT-
XlOA to ensure they are correct. If correct, a used IDE drive will function exactly as before, while a new IDE drive is now ready for operating system installation. If an error message is still displayed, you must verify and reenter the correct drive parameters.
3-8 I ET-XIOA
IDE Caching Controller Installation I 3-9
3-10 I ET-XlOA IDE Caching Controller
T
HE
AuToIDE U
TILITY
i
The AutoIDE utility is the BT-XlOA’s setup and configuration program. It gives you control over drive arrangements and cache operations. The program is stored in an onboard EPROM and EEPROM which allows you to save your own preferences as power-on defaults.
You can access the AutoIDE upon power up or system reset, when the following message appears on screen:
Primary XXX-Bus IDE Cache Controller
BusLogic, Inc. (Vx.xx)
Press F2 or F6 to enter AutolDE configuration utility.
4096K bytes of CACHE DRAM installed
Press [F2] or [F6] to access the AutoIDE main menu, illustrated below.
Disk Parameter Setup
Controller Option Select
Display Drive Information
Low Level Format
Mirror Initialization or Repair
Mirror Drive Verification
Disk Image Copy
Disk Image Compare
The AutolDE Utility I 4-1
Use the following keystrokes for moving to and selecting menu options:
Up (t) arrow key
Down (J) arrow key
Fl
FlO
Use to move cursor up and down to select menu options.
On-line help
Exit
D
ISK
P
ARAMETER
S
ETUP
This module allows you to install, link and mirror drives. It is divided into three functional feature blocks, as depicted below, which control, respectively, physical drive information, logical drive information, and installed drive information.
Disk Parameter Setup
Cylinders
IDE BUS1 Drive 0 [DO] 683
IDE BUS1 Drive 1 [D2] 0
IDE BUS2 Drive 0 [Dl] 2108
IDE BUS2 Drive 1 [D3] 0
Heads
16
0
4
0
Sectors Capacity
38 202 MB
0
49
0
OMB
201 MB
OMB
Attribute
Cylinders Heads
Sectors Trk-Remap Capacity
Drive C [DO] 683 16 38
Disabled 202 MB
Drive D [Dl] 952 7
62 Disabled 201 MB
Drive E [D2] 0 0
0 Disabled OMB
Drive F [D3] 0 0 0 Disabled OMB
IDE BUS1 Drive 0 - Maxtor 7213 AT
IDE BUS1 Drive 1 -
IDE BUS2 Drive 0 -ALPS ELECTRIC Co., LTD. DR312C
IDE BUS2 Drive 1 -
I
L
Physical Drive Information
The first block displays the parameters (cylinders, heads and sectors) for each physical IDE drive connected to the BT-XlOA. In the example, two drives, with capacity of 202MB and 201MB, are separately connected to IDE
BUS1 and IDE BUS2.
IDE BUS1 Drive 0 [DO]
IDE BUS1 Drive 1 [D2]
IDE BUS2 Drive 0 [Dl]
IDE BUS2 Drive 1 [D3]
Cylinders Heads
683
0
2108
0
16
0
4
0
Sectors
38
0
49
0
Capacity = (Cylinders) x (Heads) x (Sectors) x 512 Bytes
Capacity
202 MB
OMB
201 MB
OMB
L
These parameters are normally read from the IDE drive and automatically updated without user intervention. However, if an IDE drive fails to respond to the IDE Identify Drive request issued by the BT-XlOA, you may need to manually enter the correct parameters based on the manufacturer’s recommendations.
[DO] is short for IDE BUS1 Drive0 and [D2] is for Drivel. As for drives connected to IDE BUS2, [Dl] is short for Drive 0 and [D3] is for Drivel. These short names will correspond to the next block of this module for further settings, such as linking or mirroring.
Logical Drive Information
The second feature block of this module displays the parameters of the four logical drives units supported by the BT-XlOA and presented to the operating system. The logical drive here may be an individual drive, linking pair of two drives or mirroring pair of two drives.
The following block shows two individual drives installed:
4-2
I
ET-XlOA IDE Caching Controller
The AutolDE Utility I 4-3
Attribute Cylinders Heads Sectors Trk-Remap
Capacity
Drive C [DO] 683 16 38
Disabled 202 MB
Drive D [Dl] 952 7 62
Disabled 201 MB
Drive E [D2] 0
0 0 Disabled OMB
Drive F [D3] 0 0 0 Disabled OMB
Note: Drive C, D, E, and F shown in this block arefor ordering purpose only and
not related to system‘s drive ordering. For example, if a 201MB drive is installed
on the IDE BUS1 Drivel, i.e., 1021, this block will display 1021 as Drive E. But from the system, it sees LO21 as Drive D.
Also note that if the drive’s cylinder number shown in the top block is greater than 1024, the controller can be set to translate the parameters into a format that allows for proper operation (see section on Track Remapping).
Setting Attributes
Initially, [DO] to [D3] shown in this column correspond to those of upper block.
Use this portion of the Disk Parameter Setup module to configure for
Linking or Mirroring. You must first set one of the pair to [Non-installed] to access the Link/Mirror option for the other drive. When you’ve set one of the drives to non-installed, you will have access to a list of attributes similar to the one shown below:
PO1
PII q
[Non-installed]
The following full screen shows [DO] and [Dl] are mirrored as a pair. The linking case is similar.
4-4 I BT-XlOA IDE Caching Controller lr
IDE BUS1 Drive 0 [DO]
IDE BUS1 Drive 1 [D2]
IDE BUS2 Drive 0 [Dl]
IDE BUS2 Drive 1 [D3]
Disk Parameter Setup
Cylinders
683
0
2108
0
Heads
16
0
4
0
Sectors
38
0
49
0
Capacity
202 MB
OMB
201 MB
OMB
Attribute
Cylinders Heads Sectors Trk-Remap Capacity
Drive C [DO mirror Dl] 952 7
62 Disabled 201 MB
Drive D [Non-installed] 0
0 0 Disabled OMB
Drive E [D2]
Drive F [D3]
0
0
0
0
0
0
Disabled
Disabled
OMB
OMB
7
IDE BUS1 Drive 0
IDE BUS1 Drive 1
IDE BUS2 Drive 0
IDE BUS2 Drive 1
- Maxtor 7213 AT
-
-ALPS ELECTRIC Co., LTD. DR312C
-
I ,
I’
To select the proper attribute for Mirroring, set one of the drives to [Noninstalled], in this case [Dl], and then set the other drive to [Dn mirror Dn], in this case [DO mirror Dl]. The capacity shown in this block will be the smaller of the two. To optimize the performance of dual channel design, the mirroring function requires you to work with two drives connected to two individual buses, i.e., IDE BUS1 and IDE BUS2. You cannot do mirroring for two linking pairs on the two buses, either. Four mirrored pairs are possible from the physical drive point of view:
IDE BUS1 ======>
Drive 0 [DO]
IDE BUS2 ====z=>
Drive 0 [Dl]
Drive 1 [D3]
Linking configuration is similar to Mirroring, except that Linking requires that the two drives be on the same bus, either IDE BUS1 or IDE BUS2. So there are two possible linking pairs for each controller. The capacity shown in this block will be the summation of the two linking drives.
The AutolDE Utility I 4-5
To properly set the attribute, you can boot from a different drive each time.
For example, you have two drives installed with different operating systems and will work with them from time to time. If you work with DOS at the beginning, the setting may look like this:
DRIVE C
DRIVE D
DRIVE E
DRIVE F
Attribute
[DOI
PI
P-4
P31
DOS drive
(no disk)
SC0 UNIX drive
(no disk)
System
C: ==> Boot Drive
D:
If you work with SC0 UNIX next time, the setting may change like the following. If you’re not able to change to the desired options, you can try to set the attribute(s) to [Non-installed] for some of them. This allows more options for the drive you want to work with.
DRIVE C
DRIVE D
DRIVE E
DRIVE F
Attribute
PI
PO1
PI
P31
SC0 UNIX drive
DOS drive
(no disk)
(no disk)
System
C: ==> Boot Drive
D:
I
If more than two drives, link/mirror pair treated as one, are installed, you have to enable the More Than 2 Drives option of the Controller Option
Select module.
Note: Once you have set the drive attributes for mirroring, you must initialize mirroring using the AutoIDE’s Mirror initialization or Repair module described later in this section.
Track-Remap
This
Track-Remapping function is disabled by default and should be enabled only when the capacity of the drive exceeds 528MB.
Note: The INT13 BIOS Selection option in the Controller Option Select module has to be set to Enhanced INT13 (Shadowed or not).
4-6 I BT-XlOA IDE Caching Controller
If installing a previously configured drive,
(1) maintain drive type as 1
Caution: Ifdrive type is not set to 2, all data on drive will be destroyed
(2) and drive cylinder number is >1024, Track Remapping should be disabled or perform a backup of the device before remapping.
installed Drive Information
The bottom portion of the Disk Parameter Setup screen indicates the physical bus connection of drive(s) controlled by the BT-XlOA. The following shows two drives connected to IDE BUS1 and IDE BUS2, respectively.
IDE BUS1 Drive 0 - Maxtor 7213 AT
IDE BUS1 Drive 1 -
IDE BUS2 Drive 0 - ALPS ELECTRIC Co., LTD. DR312C
IDE BUS2 Drive 1 -
C
O N T R O L L E R
O
P T I O N
S
E L E C T
The Controller Option Select screen gives you access to the advanced features supported by the BT-XlOA:
Controller Option Select
I
Cache Line Size
Cache Function
0.5K
Enabled
- Default
More Than 2 Drives Disabled
- Default
INTI 3 BIOS Selection - Enhanced INT13 Shadowed
- Default
- Default
Controller I/O Port
Primary
- Default
Floppy Controller
Enabled
- Default
ROM BIOS Address
C800H
- Default
Green Cache Mode
Disabled
- Default
The AutolDE Utility I 4-7
Cache Line Size
You can set the cache line size to one of the following:
0.5K
(default)
1K
2 K
4 K
8 K
While the default suits most applications, you can select other options for your specific needs. For example, you may want to choose 4K for NetWare system if the block size of its file system is also 4KB.
More Than 2 Drives
The More Than 2 Drives option allows support of up to eight logical drives-an individual drive, linking pair or mirroring pair-under DOS 5.0
and above, Windows and NetWare. Where two BT-XZOAs are installed, enable
this option on the one serving as the seconda y controller togain access to its drives.
Also note that: n n
The INT13 BIOS Selection option on this screen has to be set to
Enhanced INT13 (Shadowed or not).
To support the more than two drive function for other operating systems, you have to install their respective drivers.
INT13 BIOS Selection
INT 13 BIOS allows you to select the INT 13 handler, a DOS software interrupt used to control hard disk I/O (read/write operations). Three options exist: Enhanced INT13 shadowed to system RAM (default), Enhanced INT13 and Mainboard INT13.
EnhancedINT13Shadowed.Thisoptiontakes thatportionofthecontroller’s
ROM which normally handles INT 13, and remaps it to conventional memory (O-640KB), where it occupies 1KB (639KB-640KB). This option is provided, and enabled by default, to ensure compatibility with some early
4-8
I
ET-XIOA IDE Caching Controller versions of BIOS, which may otherwise experience timing problems with the BT-XlOA (and IDE drives generally).
Enhanced INT13: It functions like the previous option except it instructs the controller to handle INT 13 from its ROM address in reserved memory and does not occupy 1KB from the system memory.
Mainboard BIOS INT13: This
option assigns the handling of INT 13 to the system BIOS instead of the controller BIOS. Some versions of BIOS also support the remapping to conventional memory of the INT 13 BIOS handling routines; consult your system manual for details.
Note: Enhanced lNTl3 (Shadowed or not) option must be set to work with
(1) More than 2 drives environment and (2) DOS partition greater than 528MB per drive with Trk-Remap option enabled.
Cache Function
This function allows you to set the cache as Enabled or Disabled. The cache is Enabled by default, but you may find it necessary to temporarily disable the cache (e.g., when installing a new operating system or hardware). When cache status is disabled, data transfer requests and commands are passed directly to the drive itself.
Controller l/O Port
There are two options for the controller I/O port:
Primary
=> port address (lFO-lF7) --> defauZt
Secondary => port address (170-177)
The Seconda y option is useful when another IDE card is installed in the same system. Remember to enable the More Than 2 Drives option to gain access to the drive(s) controlled by the secondary controller. You are allowed to put two BT-XlOA controllers in the system and thus can control up to eight individual drives. (For operating systems other than DOS, device drivers are needed.)
Note: For BT-SlOA, besure thesettingforl’in-5JP3 is sameas theoption set here.
The AutolDE Utility I 4-9
Floppy Controller (BT-410A and BT-51OA only)
This option lets you Enabled/Disabled the floppy controller. Note that only one floppy controller can be enabled in the system.
ROM BIOS Address
There are six ROM BIOS address options:
C800H
(default)
CCOOH
DOOOH
D400H
D800H
DCOOH
Select the desired option by moving the cursor (using the Up and Down
Arrow keys) to the desired option and pressing <Enter>.
When there is an I/O ROM address conflict between or among add-on cards installed in the system, you have to switch the ROM addresses on those cards to different locations. One way is to adjust the other card’s ROM address to avoid conflict. The other way is to pull out the other card(s) first, install this module, and then plug back the other card(s) for system operation. Also, note that the BT-XlOA’s ROM address always precedes that of other host adapter(s), if available.
Green Cache Mode (Power Saving Mode)
If enabled, the BT-XlOA will start to monitor the access activities to the storage subsystem. If the duration of the Idle state exceeds the time limit defined in this mode, the BT-XlOA will then turn the drive(s) and controller itself into Motor Off and Sleeping modes, respectively, in order to save power. Eight options are available:
Disabled (default) l/2 minute
1 minute
3 minutes
5 minutes
10 minutes
15 minutes
30 minutes
4-10 I ET-XlOA IDE Caching Controller
D
ISPLAY
D
RIVE
I
N F O R M A T I O N
This screen shows information about the physical drives attached to the BT-
XlOA. Note that the information that’s displayed differs from drive to drive.
A sample screen is shown below. Press the Up and Down Arrow keys to move from one Drive View to another:
IDE BUS1 Drive 0
Drive model ............................. Maxtor 7213 AT
Firmware revision ................... .5ADF1750
Serial # .................................... Bl OF4JBS
Cylinders ................................. 683
Heads ...................................... 16
Sectors ................................... .38
Buffer type ............................... dual port multiple sector with look ahead
PI0 timing ............................... Mode 0
:
600 ns cycle time
Read write multiple ................. .32 sectors per interrupt
Switch to another screen to view the information of the other drive:
IDE BUS2 Drive 0
Drive model ............................. ALPS ELECTRIC Co., LTD. DR312C
Firmware revision .................... FSOl DO1
Serial # ....................................
Cylinders ................................ .2108
Heads ..................................... .4
Sectors ................................... .49
Buffer type
...............................
dual port multiple sector with look ahead
PI0 timing ............................... Mode 0
:
600 ns cycle time
Read write multiple.. ................ Not supported
The AutolDE Utility I 4-11
Low L
EVEL
F
O R M A T
An IDE drive is formatted and ready for operating system installation when shipped by the manufacturer. Under normal circumstances, it is unnecessary and inadvisable to low level format an IDE drive. In the event that a low level format seems necessary (e.g., multiple bad sectors), contact your dealer or drive manufacturer before proceeding. Some IDE drive manufacturers build low level format routines into the drive itself, and supply special model-specific software programs for this purpose.
Warning: Performing a low-level format causes all information and data on the drive to be lost.
If you choose to execute a low level format from the AutoIDE, enter the manufacturer’s recommended drive parameters or obtain the parameters from the Display Drive Information screen. IDE drives normally support l-to-l, or non-interleaved, operation.
Note: Linked or mirrored drives will be formatted together.
A sample screen is depicted below. Select the desired option by moving the cursor (using the Up and Down Arrow keys) to the desired option and pressing <Enter>.
Select a drive for low level format
IDE BUS1 Drive0 Maxtor 7213AT
IDE BUS2 Drive0 ALPS ELECTRIC Co., LTD. DR312C
M
IRROR
I
NITIALIZATION OR
R
E P A I R
The Mirror Initialization or Repair module initializes mirroring for a pair of drives once the attribute for these drives has been set using the Drive
Parameter Setup module (This module is not available unless the mirroring attribute has been set). When initialized, the system creates and maintains an exact duplicate of the source drive. This screen is also used when you need to repair a drive in a mirror pair and restore the data once one of the mirror-pair drives is in trouble.
4-12 I ET-XIOA IDE Caching Controller
Select the mirror drive for initialization or repair
IDE BUS1 Drive0 -
Maxtor 7213AT
IDE BUS2 Drive0 - ALPS ELECTRIC Co., LTD. DR312C
Status
U
U
The Status column indicates the status of a mirror pair. Drive status could be any one of the following:
U: Un-Initialized Drive (before mirror initialization is done)
0 : Drive OK (once mirror initialization or repair is completed)
D: Drive Damaged (any one of the mirror pair is crashed)
The mirror initialization always duplicates the source disk to the target disk. You can designate the source and target drives by pressing <Space
Bar>.
Select the mirror drive for initialization or repair
Status
IDE BUS1 Drive0 - Maxtor 7213AT
U
IDE BUS2 Drive0 - ALPS ELECTRIC Co., LTD. DR312C
U
Source
Target
After the Mirror Initialization is completed, Status should display 0 for both mirroring drives, which signifies they are ready to work as a mirror pair.
Select the mirror drive for initialization or repair
Status
IDE BUS1 Drive0 - Maxtor 7213AT
0
IDE BUS2 Drive0 - ALPS ELECTRIC Co., LTD. DR312C
0
Source
Target
If one of the drives in the mirror pair is malfunctioning or crashed, the mirroring beeper will start to issue alarms (if JP2 is properly connected).
Check for a bad cable connection, a bad drive, a bad power supply, etc., if
The AutolDE Utility I 4-13
you see a mirroring problem. All of these could cause inconsistency between the two drives. Refer to this screen to check which drive is damaged.
Select the mirror drive for initialization or repair
Status
IDE BUS1 Drive0 - Maxtor 7213AT
0
IDE BUS2 Drive0 - ALPS ELECTRIC Co., LTD. DR312C
D
Source
Target
To restore the mirror pair after the problem has been resolved, you must set the drive marked as D to Target and the one marked as 0 to Source. The beeping alarm will stop right after the mirror repair is completed.
M
I R R O R
D
R I V E
V
E R I F I C A T I O N
This module performs a disk comparison between the two drives of the same mirror pair. You may need tore-do the mirror initialization if incorrect data is found in one of the drives. This module is not available unless the mirroring attribute has been set.
Select the mirror drive for Verification
Status
IDE BUS1 Drive0 - Maxtor 7213AT
0
IDE BUS2 Drive0 - ALPS ELECTRIC Co., LTD. DR312C 0
Source
Target
D
ISK
I
M A G E
C
O P Y
This module copies the data from the source disk to the target disk on a drive-to-drive basis. Select the desired drive using the Up and Down Arrow keys and press <Enter> to execute the copy.
I
D
ISK
I
M A G E
C
O M P A R E
Select source and target disks for image copy
IDE BUS1 Drive0 - Maxtor 7213AT
IDE BUS2 Drive0 - ALPS ELECTRIC Co., LTD. DR312C
Source
Target
This module compares the data of the source disk with that of the target disk on a drive-to-drive basis. Select the desired drive using the Up and Down
Arrow keys and press <Enter> to execute the compare.
Select source and target disks for image compare
IDE BUS2 Drive0 - ALPS ELECTRIC Co., LTD. DR312C
4-14 I ET-XlOA IDE Caching Controller
The AutolDE Utility I 4-15
NETWARE 4.0X
The subdirectory IDENV40X.DSK, contains the NETWARE V4.OX device driver. The following describes the key procedures during driver installation:
After seeing a message block showing “Scanning for available drivers . ..” during the installation, you’ll find a list of default supported drivers.
Press <Ins> key to install the driver, IDENV40.DSK, from drive A:.
Press <F3> key to specify the path: >A:\NETWARE.40. Select
IDENV4O.DSK and press <Enter> to load this driver.
Press <Return> again to set the I/O port address and IRQ.
NETWARE 3.1X
The subdirectory IDENV31X.DSK, contains the NETWARE V3.1X device driver. The installation procedures are the same for NETWARE V3.1 below, except the driver loaded here is IDENV31X.DSK.
NETWARE 3.1
The subdirectory IDENV31.DSK, contains the NETWARE V3.1 device driver. The installation procedures follow:
For one card installation
1. Install the BT-XlOA:
A) Remove other add-on cards that may conflict with BT-XlOA’s
ROM space
B) Select this card as primary
C) Select the ROM space for the BT-XlOA
D) Enable the floppy diskette
2. Plug another add-on card if necessary
3. Boot DOS
5-2 I ET-XlOA IDE Caching Controller
4.
5.
6.
7.
Copy the BusLogic NETWARE driver, IDENW31X.DSK, from the
BusLogic driver diskette to either the NETWARE boot floppy or the
NETWARE subdirectory on your hard drive
Load NETWARE. When the NETWARE server prompt “:” appears
Load IDENV31
Using the NETWARE Install utility, save the NCF files to reflect your new configuration.
6.
7.
8.
3.
4.
5.
Where duplexing is required:
1.
2.
Install the secondary BT-XlOA first:
A) Remove other add-on cards that may conflict with BT-XlOA’s
ROM space
B) Select this card as secondary
C) Select the ROM space for the BT-XlOA
D) Disable the floppy diskette
Install the primary BT-XlOA:
A) Select this card as primary
B) Select the ROM space for the BT-XlOA
C) Enable the floppy diskette
Plug another add-on card if necessary
Boot DOS
Copy the BusLogic NETWARE driver, IDENW31X.DSK, from the
BusLogic driver diskette to either the NETWARE boot floppy or the
NETWARE subdirectory on your hard drive
Load NETWARE. When the NETWARE server prompt ‘I:” appears
Load IDENV31
Using the NETWARE Install utility, save the NCF files to reflect your new configuration.
Driver Installations
I
5-3
NETWARE 2.Xx
This diskette is also labeled as DSK_DRV_003 and two files IDENV215.DSK
and IDENV215.0BJ in the root directory are used as the hard disk device driver for NETWARE V2.15. Follow the NETWARE V2.15’~ installation guide to install the server.
OS/2 v2.x
To install this driver:
1.
2.
3.
Insert the BusLogic driver diskette into the floppy drive
Under OS/2 V2.X, install the driver by keying the following command:
[C:\]
ddinstal
Set the source drive letter to reflect the floppy drive containing the driver diskette
This command copies the file, OS2_32.ADD, from the driver diskette to C:\OS2 directory and replaces the file IBMlS506.ADD in it. The old IBMlS506.ADD will be re-named as IBMlS506.1, which also resides in the C:\OS2 directory.
4. Re-boot the system
To remove the driver:
1. Copy the file, IBMlS506.1, to replace the file, IBMlS506.ADD. Both files are in the same directory, C:\OS2:
[C:\OS2] COPY lBMlS506.1 IBMlS506.ADD
2.
Re-boot the system.
UNIX
For installation in some UNIX environments, cache must be disabled.
Cache must be disabled on the BT-XlOA before you install the SC0 UNIX operating system. For further details, refer to the README file supplied with the product and the UNIX operating system documentation.
5-4 m
BT-XIOA IDE Caching Controller
AT H
ARD
D
RIVE
T
Y P E S
TYP
9
10
11
12
13
14
7
8
5
6
15
1
2
3
4
The first fifteen drive types were defined by IBM in the original AT. Since
then,
additional types have been defined, so the table in your machine may vary.
In the following table, these abbreviations are used:
TYP
CYl
Hds
CmP
Zon
Set
Mb
Drive type number
Number of cylinders
Number of heads
Pre-compensation
Landing zone
Number of sectors
Approximate number of megabytes
CYl
462
733
900
820
855
855
306
733
0
306
615
615
940
940
615
Hds
0
8
7
5
7
15
3
8
5
6
4
6
8
4
4
Zon
511
733
901
820
855
855
305
615
615
940
940
615
319
733
0
Cmp
-1
-1
256
-1
-1
-1
128
-1
0
128
300
300
512
512
-1
Set
17
17
17
17
17
17
17
17
17
17
17
17
0
17
17
AT Hard Drive Types m A-l
M b
20
40
0
30
30
110
20
35
50
10
20
32
64
48
20
Hds
5
7
5
4
5
7
7
4
7
9
7
4
4
7
4
7
5
5
2
8
10
4
4
4
7
6
4
8
3
7
9
8
5
2
7
11
15
7
11
10
A-2 I BT-XlOA IDE Caching Controller
TYP
35
36
37
38
39
40
41
42
28
29
30
31
32
33
34
22
23
24
25
26
27
16
17
18
19
20
2 1
48
49
50
5 1
43
44
45
46
47
52
53
54
55
CYl
977
981
830
830
612
306
1024
612
1024
1024
615
987
987
820
612
698
976
306
611
732
1023
306
1024
733
306
925
925
754
754
699
823
918
1024
1024
612
977
977
1024
733
733
0
0
0
-1
-1
0
0
305
300
488
0
306
300
-1
-1
512
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
300
300
0
0
300
-1
512
300
Set
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
Zon
615
987
987
820
977
981
830
823
918
1024
1024
1024
611
1024
1024
336
925
925
754
754
699
663
977
977
1023
732
733
733
830
663
340
670
732
977
340
663
732
1023
305
1024
Mb
40
24
57
40
42
10
76
68
43
68
40
68
53
93
127
40
10
20
42
42
5
68
IO
20
40
32
32
48
68
20
20
40
56
60
30
42
30
10
53
70
E
RROR
M
ESSAGES AND
G
ENERAL
T
ROUBLESHOOTING
T
IPS
Error codes may be generated at various stages in the Model BT-XlOA’s
BIOS initialization procedure. If an error occurs, the BIOS will display a message accompanied by one of several error codes, which are listed below.
Code Message Description
1 Controller Failure!
2 Controller Failure!
3 Cache Operation Failure!
4 Cache Operation Failure!
5 Cache Operation Failure!
6 Cache Operation Failure!
7 Controller Failure!
Extendedcommandenabled
Query controller information
Write back cache to drive and flush cache
Disable cache
Write cache DRAM
Read cache DRAM
Query controller information error during DRAM test
8 Cache RAM Error at Bank 0
9 Cache RAM Error at Bank 1
DRAM error at bank 0
DRAM error at bank 1
10 Cache RAM Error at Bank 2
DRAM error at bank 2
11 Cache RAM Error at Bank 3
DRAM error at bank 3
12 No Cache RAM Installed!
No DRAM installed
13 Controller Failure!
Read EEPROM
14 Controller Failure!
Write EEPROM
15 Controller EPROM Checksum Error! Controller EPROM checksum error
Error Messages and General Troubleshooting Tips
I
B-l
On powering up the system, if the Model BT-XlOA issues the message Error
Code = 1 with no further details, one of four possibilities exists: w Controller is not functional n
No Cache DRAM is installed n
TAG SRAM test failure n
Parity error on cache DRAM
Power off the system, wait a few moments and then power the system back on. Some versions of BIOS may issue a HDD Controller Failure message if no cache DRAM is installed.
General Troubleshooting Tips
Most controller errors are traceable to external factors, such as conflicts with other installed cards, bad or incorrectly configured drives, loose cables or other installation errors.
When a problem occurs in your system, you can always try to verify the possible causes by changing various components in your system, such as
I/O card, motherboard, DRAM SIMM, or CPU. The following are general guidelines for some specific error conditions.
1. The LED connected to JPl flashes some diagnostics right after power-up. The following shows the flash frequency of each fatal error condition: n n
One short flash: No Cache DRAM installed
Two short flashes: CPU error n
Three short flashes: SRAM error w Four short flashes: Timer error
2. No BIOS message from BT-XlOA, i.e., <Press F2 or F6 . ..>. appears on the screen: n
ROM address conflicting with other I/O card(s). Check the ROM addresses of all the I/O cards and make sure there are no conflicts.
B-2 I ET-XIOA IDE Caching Controller n
VGA card with “Fast Address Decode” option enabled. This may cause all I/O cards that employ &bit ROM BIOS, BT-XlOA included, not to be recognized. Disable this option, if available.
3. Missing operating system: n
Could be the parameters scanned by the BT-XlOA, directly from the drive itself, differ from drive supplier’s. Enter the CUSTOM-
IZED CONFIGURATION module of AutoIDE and key in the parameters provided by drive supplier manually.
4. System hangs after running for a while: n n
ROM BIOS might be “shadowed” by motherboard. Check the setup of your motherboard and disable the “shadow” option on
BT-XlOA’s ROM address.
Cabling (error condition varies). Could try DIAGNOSTIC module of AutoIDE to check if the cabling is O.K.
5. FDC error: n
Could be more than one FDC enabled: make sure only one FDC is enabled.
6. Cannot access HDD: n
Check if the HDD type in your system’s CMOS is set to “1.”
7. Cannot recognize the HDD’s parameters or cannot save them correctly: n
Try to place the jumper cap over JDRO, i.e., short, if the HDD is connected to the FIRST IDE BUS. If connected to SECOND IDE
BUS, then short JDRl.
8. Possible incompatible conditions for default option (CTRL BIOS moved to RAM) of INT 13 BIOS: n
The default option gains the optimal performance. Due to its nature of occupying 1KB (639KB-640KB), some software programs
Error Messages and General Troubleshooting Tips I B-3
may issue false alarms, such as virus-protection software. The above problems can be avoided by choosing another option
“Motherboard BIOS.”
Due to the same nature of 1KB occupancy, the default option may have a conflict when executing the OS/2. Since the OS/2 would only employ its disk I/O routines, the above problem can also be avoided by choosing another option “Motherboard BIOS” without degrading any performance.
Since the CTRL BIOS options are for DOS (Windows) and not related to UNIX, it is recommended that you choose the
“Motherboard BIOS” to operate under these environments.
9. Not able to run with Windows 32-bit driver: n
Change the INT13 BIOS/Customized Configuration option to
“Motherboard BIOS” and install the Windows 32-bit driver during setup.
P
R O D U C T
S
U P P O R T
R
E C O R D
The information on this page should be compiled and provided to your supplier in writing to obtain technical support assistance. This will enable your supplier to respond more rapidly and more appropriately to your problem.
About BusLogic Product:
BusLogic Product No:
Serial Number:
Date of Purchase:
Firmware Version Number:
BIOS Version Number:
Purchased From:
Company:
Address:
Purchased By:
Name/Title:
Company:
Address:
Telephone #:
About System Hardware Configuration:
System Manufacturer:
System Model and Speed:
System BIOS Manufacturer:
Memory in System:
Hard Drives on System:
About System Software Configuration:
Operating System/Version:
Application Program/Version:
Detailed Description of Problem:
B-4 I ET-XIOA IDE Caching Controller
S
TANDARD
W
A R R A N T Y
BusLogic warrants that subject to the terms of this policy the Products shall be free from defects due to faulty material or workmanship on the part of BusLogic for a period of one year from the date of delivery.
This warranty shall not apply if the Products have been subject to misuse by Customer or any other party; if any material alteration, addition, amendment, or modification shall have been carried out without the prior written consent of BusLogic; failure to install or operate the Products in accordance to BusLogic’s Product reference manual; or failure caused by improper or inadequate maintenance of users.
BusLogic will make good by repair or at its option by replacement any
Products which become defective within the warranty period. Repairs will be warranted for 90 days. Products or parts replaced under this provision shall become the property of BusLogic.
BEFORE RETURNING A PRODUCT FOR REPAIR, BUYER MUST RE-
QUEST A RETURN MATERIAL AUTHORlZATlON (RMA) NUMBER FROM
BUSLOGIC.
All Products under warranty returned to BusLogic for repair shall be returned to Customer at BusLogic’s expense. Shipping costs for all Products returned to BusLogic for repair which are out of the warranty period shall be at Customer’s expense both to and from BusLogic.
Customer is expressly prohibited from issuing Debit Memos for material returned under the provisions of this warranty.
BusLogic shall notify Customer in the event that the Products returned for repair are not, in BusLogic’s sole opinion, within this Warranty condition and, unless disposition instructions are given for such Products within thirty (30) days of such notification, the Products will be returned to
Customer freight collect.
EXCEPT FOR THE ABOVE EXPRESS LIMITED WARRANTY, BUSLOGIC
MAKES NO WARRANTlES, EXPRESS, IMPLIED OR STATUTORY, AND
BUSLOGIC SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF
MERCHANTABlLlTY OR FlTNESS FOR A PARTICULAR PURPOSE.
The total liability of BusLogic for any claim or damage arising out of this
Agreement, and whether in contract or in tort, shall not exceed the price of the individual Product(s) whose defect or damage is the basis of the claim.
IN NO EVENT SHALL BUSLOGIC BE LIABLE FOR ANY LOSS OF PROFlTS
OF FOR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES.
No action against BusLogic for breach of the warranty shall be commenced more than one (1) year after the accrual of the cause of action.
Customer also agrees to perform its duties and responsibilities under
BusLogic’s Warranty Policy, which shall be updated from time to time.
Addendum
The KT-XlOA family of IDE Caching Controllers now supports attachment of up to two (2) ATAPI compatible devices in addition to supporting up to four (4) hard disk drives. Other functionality of the controllers remain the same.
Connector CN4 (refer to Board Diagram) is used to attach ATAPI compliant devices such as CD-ROM and tape drives using a standard 40-pin AT data cable.
If you install two Xl OA Cache Controller in a single system, then you cannot use the ATAPI interface on either board. This is due to the fact that each board requires a primary or secondary port address. Jumper JP3 is used to control this.
With JP3 installed, the secondary port address 170h is used for the ATAPI connector. You must disable jumper JP3 (remove) if you install two XlOA cache controllers in a single system.
JP3 Installed
JP3 Removed
1
ATAPI
Supported
Disable ATAPI
Use second cache controller
Addendum
BusLogic supplies an interrupt bridge paddle board with the BT-9 1 OA to accommodate PC1 systems that can not route the IDE interrupt (INT 14 or
INT 15) to a PC1 slot. In most cases the BT-910A can be installed in your
PC1 system without the interrupt bridge paddle board. Please refer to BT-
X 1 OA User’s Guide chapter 2 for installation instructions. If your system does not boot after installing the BT-9 1 OA, follow these instructions to install the interrupt bridge paddle board and restart your system.
Remove the BT-9 1 OA from your system.
Remove the jumper on JP3-1.
Connect
CNl on the interrupt bridge paddle board to JP4 on the BT-
9
1 OA using the ribbon cable supplied (see diagram below)
Reinstall the BT-9 10A in a PC1 slot.
Insert the interrupt bridge board in the ISA or EISA slot nearest the PC1 slot containing your BT-910A.
/ INTERRUPT BRIDGE PADDLE BOARD
]
Pz Edge Connector J L
PI Edge Connecta
BT-41
OCD Board Diagram
The device driver diskette contains a Windows-based CD-ROM utility for audio and PhotoCD’s. Please refer to the README.CD file found in the <CD_APPS> directory of the driver diskette for installation instructions.
Acer CD625A
N E C MultiSpin_2Vi/CDR-260R
S o n y CDU55E
Mitsumi CRMC-FXOO lDE/FX400
Philips
CR-940
Wearnes CDD- 120
3
BT-91OA
J P 4
Download