An IDE drive is formatted and ready for operating system installation when shipped by the manufacturer. Under normal circumstances, it is unnecessary and inadvisable to low level format an IDE drive. In the event that a low level format seems necessary (e.g., multiple bad sectors), contact your dealer or drive manufacturer before proceeding. Some IDE drive manufacturers build low level format routines into the drive itself, and supply special model-specific software programs for this purpose.
Warning: Performing a low-level format causes all information and data on the drive to be lost.
If you choose to execute a low level format from the AutoIDE, enter the manufacturer’s recommended drive parameters or obtain the parameters from the Display Drive Information screen. IDE drives normally support l-to-l, or non-interleaved, operation.
Note: Linked or mirrored drives will be formatted together.
A sample screen is depicted below. Select the desired option by moving the cursor (using the Up and Down Arrow keys) to the desired option and pressing <Enter>.
Select a drive for low level format
IDE BUS1 Drive0 Maxtor 7213AT
IDE BUS2 Drive0 ALPS ELECTRIC Co., LTD. DR312C
M
IRROR
I
NITIALIZATION OR
R
E P A I R
The Mirror Initialization or Repair module initializes mirroring for a pair of drives once the attribute for these drives has been set using the Drive
Parameter Setup module (This module is not available unless the mirroring attribute has been set). When initialized, the system creates and maintains an exact duplicate of the source drive. This screen is also used when you need to repair a drive in a mirror pair and restore the data once one of the mirror-pair drives is in trouble.
4-12 I ET-XIOA IDE Caching Controller
Select the mirror drive for initialization or repair
IDE BUS1 Drive0 -
Maxtor 7213AT
IDE BUS2 Drive0 - ALPS ELECTRIC Co., LTD. DR312C
Status
U
U
The Status column indicates the status of a mirror pair. Drive status could be any one of the following:
U: Un-Initialized Drive (before mirror initialization is done)
0 : Drive OK (once mirror initialization or repair is completed)
D: Drive Damaged (any one of the mirror pair is crashed)
The mirror initialization always duplicates the source disk to the target disk. You can designate the source and target drives by pressing <Space
Bar>.
Select the mirror drive for initialization or repair
Status
IDE BUS1 Drive0 - Maxtor 7213AT
U
IDE BUS2 Drive0 - ALPS ELECTRIC Co., LTD. DR312C
U
Source
Target
After the Mirror Initialization is completed, Status should display 0 for both mirroring drives, which signifies they are ready to work as a mirror pair.
Select the mirror drive for initialization or repair
Status
IDE BUS1 Drive0 - Maxtor 7213AT
0
IDE BUS2 Drive0 - ALPS ELECTRIC Co., LTD. DR312C
0
Source
Target
If one of the drives in the mirror pair is malfunctioning or crashed, the mirroring beeper will start to issue alarms (if JP2 is properly connected).
Check for a bad cable connection, a bad drive, a bad power supply, etc., if