Use the following keystrokes for moving to and selecting menu options:
Up (t) arrow key
Down (J) arrow key
Fl
FlO
Use to move cursor up and down to select menu options.
On-line help
Exit
D
ISK
P
ARAMETER
S
ETUP
This module allows you to install, link and mirror drives. It is divided into three functional feature blocks, as depicted below, which control, respectively, physical drive information, logical drive information, and installed drive information.
Disk Parameter Setup
Cylinders
IDE BUS1 Drive 0 [DO] 683
IDE BUS1 Drive 1 [D2] 0
IDE BUS2 Drive 0 [Dl] 2108
IDE BUS2 Drive 1 [D3] 0
Heads
16
0
4
0
Sectors Capacity
38 202 MB
0
49
0
OMB
201 MB
OMB
Attribute
Cylinders Heads
Sectors Trk-Remap Capacity
Drive C [DO] 683 16 38
Disabled 202 MB
Drive D [Dl] 952 7
62 Disabled 201 MB
Drive E [D2] 0 0
0 Disabled OMB
Drive F [D3] 0 0 0 Disabled OMB
IDE BUS1 Drive 0 - Maxtor 7213 AT
IDE BUS1 Drive 1 -
IDE BUS2 Drive 0 -ALPS ELECTRIC Co., LTD. DR312C
IDE BUS2 Drive 1 -
I
L
Physical Drive Information
The first block displays the parameters (cylinders, heads and sectors) for each physical IDE drive connected to the BT-XlOA. In the example, two drives, with capacity of 202MB and 201MB, are separately connected to IDE
BUS1 and IDE BUS2.
IDE BUS1 Drive 0 [DO]
IDE BUS1 Drive 1 [D2]
IDE BUS2 Drive 0 [Dl]
IDE BUS2 Drive 1 [D3]
Cylinders Heads
683
0
2108
0
16
0
4
0
Sectors
38
0
49
0
Capacity = (Cylinders) x (Heads) x (Sectors) x 512 Bytes
Capacity
202 MB
OMB
201 MB
OMB
L
These parameters are normally read from the IDE drive and automatically updated without user intervention. However, if an IDE drive fails to respond to the IDE Identify Drive request issued by the BT-XlOA, you may need to manually enter the correct parameters based on the manufacturer’s recommendations.
[DO] is short for IDE BUS1 Drive0 and [D2] is for Drivel. As for drives connected to IDE BUS2, [Dl] is short for Drive 0 and [D3] is for Drivel. These short names will correspond to the next block of this module for further settings, such as linking or mirroring.
Logical Drive Information
The second feature block of this module displays the parameters of the four logical drives units supported by the BT-XlOA and presented to the operating system. The logical drive here may be an individual drive, linking pair of two drives or mirroring pair of two drives.
The following block shows two individual drives installed:
4-2
I
ET-XlOA IDE Caching Controller
The AutolDE Utility I 4-3
Attribute Cylinders Heads Sectors Trk-Remap
Capacity
Drive C [DO] 683 16 38
Disabled 202 MB
Drive D [Dl] 952 7 62
Disabled 201 MB
Drive E [D2] 0
0 0 Disabled OMB
Drive F [D3] 0 0 0 Disabled OMB
Note: Drive C, D, E, and F shown in this block arefor ordering purpose only and
not related to system‘s drive ordering. For example, if a 201MB drive is installed
on the IDE BUS1 Drivel, i.e., 1021, this block will display 1021 as Drive E. But from the system, it sees LO21 as Drive D.
Also note that if the drive’s cylinder number shown in the top block is greater than 1024, the controller can be set to translate the parameters into a format that allows for proper operation (see section on Track Remapping).
Setting Attributes
Initially, [DO] to [D3] shown in this column correspond to those of upper block.
Use this portion of the Disk Parameter Setup module to configure for
Linking or Mirroring. You must first set one of the pair to [Non-installed] to access the Link/Mirror option for the other drive. When you’ve set one of the drives to non-installed, you will have access to a list of attributes similar to the one shown below:
PO1
PII q
[Non-installed]
The following full screen shows [DO] and [Dl] are mirrored as a pair. The linking case is similar.
4-4 I BT-XlOA IDE Caching Controller lr
IDE BUS1 Drive 0 [DO]
IDE BUS1 Drive 1 [D2]
IDE BUS2 Drive 0 [Dl]
IDE BUS2 Drive 1 [D3]
Disk Parameter Setup
Cylinders
683
0
2108
0
Heads
16
0
4
0
Sectors
38
0
49
0
Capacity
202 MB
OMB
201 MB
OMB
Attribute
Cylinders Heads Sectors Trk-Remap Capacity
Drive C [DO mirror Dl] 952 7
62 Disabled 201 MB
Drive D [Non-installed] 0
0 0 Disabled OMB
Drive E [D2]
Drive F [D3]
0
0
0
0
0
0
Disabled
Disabled
OMB
OMB
7
IDE BUS1 Drive 0
IDE BUS1 Drive 1
IDE BUS2 Drive 0
IDE BUS2 Drive 1
- Maxtor 7213 AT
-
-ALPS ELECTRIC Co., LTD. DR312C
-
I ,
I’
To select the proper attribute for Mirroring, set one of the drives to [Noninstalled], in this case [Dl], and then set the other drive to [Dn mirror Dn], in this case [DO mirror Dl]. The capacity shown in this block will be the smaller of the two. To optimize the performance of dual channel design, the mirroring function requires you to work with two drives connected to two individual buses, i.e., IDE BUS1 and IDE BUS2. You cannot do mirroring for two linking pairs on the two buses, either. Four mirrored pairs are possible from the physical drive point of view:
IDE BUS1 ======>
Drive 0 [DO]
IDE BUS2 ====z=>
Drive 0 [Dl]
Drive 1 [D3]
Linking configuration is similar to Mirroring, except that Linking requires that the two drives be on the same bus, either IDE BUS1 or IDE BUS2. So there are two possible linking pairs for each controller. The capacity shown in this block will be the summation of the two linking drives.
The AutolDE Utility I 4-5