Below you will find brief information for DVM171THD. This device can store up to 32,000 readings (16,000 temperature and 16,000 humidity). It also indicates the dew point and features a USB interface.Programmable alarm thresholds are available. The analysis software is in English only.
Advertisement
Advertisement
2 7 13 19 25 31 DVM171THD USER MANUAL 1. Introduction To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities. Thank you for choosing Velleman! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer. 2. Safety Instructions Keep this device away from rain, moisture, splashing and dripping liquids. Keep this device away from children and unauthorized users. Protect this device from shocks and abuse. Avoid brute force when operating the device. Keep this device away from dust and extreme temperatures. 3. General Guidelines Refer to the Velleman® Service and Quality Warranty on the last pages of this manual. This device is battery-operated, using one 3.6 V lithium battery (½ AA). Familiarise yourself with the functions of the device before actually using it. All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to the device is not covered by the warranty. Only use the device for its intended purpose. Using the device in an unauthorised way will void the warranty. Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems. Do not use outside the technical specifications (see §10). 4. Features memory for 32 000 readings (16 000 temperature and 16 000 humidity readings) dew point indication status indication USB interface for setup and data download user-programmable alarm thresholds for temperature and humidity V. 03 – 12/06/2013 2 ©Velleman nv DVM171THD analysis software: software in English only, for Windows® XP, Vista, Windows 7 (32 and 64 bit) multi-mode to start logging long battery life selectable measuring cycle: 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 30 min, 1 h, 2 h, 3 h, 6 h, 12 h, 24 h. 5. Use 1. 2. 3. 4. 5. 6. 7. protective cover USB connector to PC port start button RH and temperature sensors alarm LED (red/yellow) recording LED (green) mounting bracket 1. First install the data logger software on a personal computer, by inserting the enclosed disc into the CD drive and following the instructions on the screen. 2. Remove the protective cover [1] from the data logger, plug the data logger into a free USB slot on the personal computer and start the data logger software. 3. Set up the data logger software and press the Setup button. Refer to the help function of the data logger software (Help > Help topics…) for more information on the use of the software and setup of the data logger. 4. Remove the data logger from the USB slot and place back the protective cover [1]. 5. Place the device in a location where recording of ambient temperature and/or relative humidity is required. Refer to the technical specifications for allowed operating temperature range. V. 03 – 12/06/2013 3 ©Velleman nv DVM171THD 6. If the data logger is set up to start manually (delayed start), the green LED [6] will flash two times every 10 seconds. Press the Start button [3] until the green [6] and yellow LED [5] flash once (together). The data logger starts logging and the green LED [6] will flash every 10 seconds (increase this value through the setup procedure to increase battery life). 7. To download the data into the personal computer, start the data logger software, remove the protective cover [1] and plug the data logger into a free USB slot. Refer to the help function of the data logger software (Help > Help topics…) for more information on downloading and handling the data from the data logger. 6. Troubleshooting Both LEDs are off Logging is not active or battery is low. Start logging or replace battery. Green REC LED [6], flashes 1 x every 10 seconds Logging, no alarm condition. 1x Green REC LED [6], flashes 2 x every 10 seconds Delayed start mode. 2x 1x 2x 1x 1x 2x 1x Red ALM LED [5], flashes 1 x every 10 seconds Logging, humidity lower limit exceeded. Red ALM LED [5], flashes 2 x every 10 seconds Logging, humidity upper limit exceeded. Red ALM LED [5], flashes 1 x every 60 seconds Low battery. Logging will stop, replace battery and download data. Yellow ALM LED [5], flashes 1 x every 10 seconds Logging, temperature lower limit exceeded. Yellow ALM LED [5], flashes 2 x every 10 seconds Logging, temperature higher limit exceeded. Yellow ALM LED [5], flashes 1 x every 60 seconds Logger memory full. Logging will stop, download data. V. 03 – 12/06/2013 4 ©Velleman nv DVM171THD Notes: In case of one alarm, the green REC LED [6] and the red or yellow ALM LED [5] will blink alternately every 10 seconds. When two alarms occur (e.g. humidity alarm and temperature alarm), only the ALM LED [5] will blink, showing alternately the first and second alarm every 10 seconds. However, the unit cannot show both the upper and lower alarm. For example, if both the upper and lower humidity limits have been exceeded during one test period, the unit indicates either the upper or the lower alarm. Download the data to your PC to see the details of the alarms. When the battery is low, all operations are disabled automatically and memory is preserved. 7. Cleaning and Storage The humidity and temperature sensors [4] are very sensitive. Avoid dust, smoke and other particles to enter the housing. Refer to the paragraph “Sensor Reconditioning”. Wipe the data logger regularly with a moist, lint-free cloth. Do not use alcohol or solvents. Do not touch the USB connector. Do not submerge the data logger in water or any other liquid. There are no user-serviceable parts. Contact your dealer for spare parts if necessary. 8. Battery Warning: Do not puncture batteries or throw them in fire as they may explode. Do not attempt to recharge non-rechargeable batteries. Dispose of batteries in accordance with local regulations. Keep batteries away from children. To replace the battery, disconnect the device from the computer. 1. Open the battery compartment by using a pointed object (e.g. small screwdriver). Move the pointed object in the direction of the arrow. 2. Gently pull the data logger from the casing. 3. Remove/insert the battery. Only use 3.6 V lithium batteries. Make sure the polarity is as indicated in the casing. When the battery is inserted, the green and yellow LEDs will flash alternately. V. 03 – 12/06/2013 5 ©Velleman nv DVM171THD 4. Slide the data logger back in the housing until it snaps into place. Note: Make sure that you position the housing with the right side upward: the tab [a] on the data logger should fit into the notch [b] in the housing. If you place the housing upside down, pull firmly to remove it and place it back in the correct position. 5. Configure the data logger using the enclosed software. Note: Leaving the device in the USB port will reduce the battery life. 9. Sensor Reconditioning Over time, the internal sensor may become compromised as a result of pollutants, chemical vapours, or other environmental conditions. This can lead to inaccurate readings. To recondition the internal sensors, proceed as follows: 1. Heat the data logger to +80 °C (+176 °F), humidity < 5 % for 36 hours. 2. Keep the data logger at +20 to +30 °C (+70 to +90 °F), humidity > 74 % for 48 hours. 10. Technical Specifications relative humidity relative humidity accuracy temperature temperature accuracy dew point dew point accuracy logging rate power supply battery life dimensions weight overall range 0 – 100 % ± 5.0 % 0 % – 20 % ± 5.0 % 20 % – 40 % ± 3.5 % 40 % – 60 % ± 3.0 % 60 % – 80 % ± 3.5 % 80 % – 100 % ± 5.0 % overall range -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to -10 °C (-40 °F to +14 °F) ± 2 °C (± 3.6 °F) -10 °C to +40 °C (+14 °F to +104 °F) ± 1 °C (± 1.8 °F) +40 °C to +70 °C (+104 °F to +158 °F) ± 2 °C (± 3.6 °F) overall range -40 °C to 70 °C (-40 °F to 158 °F) 25 °C, 40 – 100 % RH ± 2.0 °C (± 4.0 °F) selectable sampling interval, from 2 seconds up to 24 hours, operating temperature -35 °C to 80 °C (-31 °F to 176 °F) 3.6 V lithium ½ AA (order code LS14250, incl.) ± 1 year 101 x 25 x 23 mm 42 g Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our website www.velleman.eu. The information in this manual is subject to change without prior notice. © COPYRIGHT NOTICE The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the prior written consent of the copyright holder. V. 03 – 12/06/2013 6 ©Velleman nv DVM171THD Inleiding 2. 3. 4. V. 03 – 12/06/2013 7 ©Velleman nv 5. Gebruik 1. 2. 3. 4. 5. 6. 7. beschermkap USB-aansluiting naar pc-poort startknop RH- en temperatuursensoren ALM-led (rood/geel) REC-led (groen) montagebeugel 8 ©Velleman nv 6. 1x 2x 1x 2x 1x 1x 2x 1x V. 03 – 12/06/2013 9 ©Velleman nv 7. 8. V. 03 – 12/06/2013 10 ©Velleman nv 9. De sensor kalibreren 0 – 100 % ± 5,0 % V. 03 – 12/06/2013 11 ©Velleman nv V. 03 – 12/06/2013 12 ©Velleman nv DVM171THD Introduction 2. 3. 4. V. 03 – 12/06/2013 13 ©Velleman nv 5. Emploi 1. 2. 3. 4. 14 ©Velleman nv 6. 1x 2x 1x 2x 1x 2x V. 03 – 12/06/2013 15 ©Velleman nv 7. 8. V. 03 – 12/06/2013 16 ©Velleman nv 9. 0 – 100 % ± 5,0 % V. 03 – 12/06/2013 17 ©Velleman nv V. 03 – 12/06/2013 18 ©Velleman nv DVM171THD MANUAL DEL USUARIO 1. 2. 3. Normas generales 4. V. 03 – 12/06/2013 19 ©Velleman nv 5. Uso 1. 2. 3. 4. 20 ©Velleman nv 6. 1x REC LED [6] verde, parpadea 2 veces cada 10 segundos Modo de inicio temporizado. 2x 1x 2x ALM LED [5] rojo, parpadea 1 vez cada 10 segundos Registro de datos, el límite inferior de humedad se ha sobrepasado. ALM LED [5] rojo, parpadea 2 veces cada 10 segundos Registro de datos, el límite superior de humedad se ha sobrepasado. 1x 2x ALM LED [5] amarillo, parpadea 1 vez cada 10 segundos Registro de datos, el límite inferior de temperatura se ha sobrepasado. ALM LED [5] amarillo, parpadea 2 veces cada 10 segundos Registro de datos, el límite superior de humedad se ha sobrepasado. V. 03 – 12/06/2013 21 ©Velleman nv 7. 8. 22 ©Velleman nv 9. Volver a condicionar el sensor 23 ©Velleman nv DVM171THD dimensiones peso 101 x 25 x 23 mm 42 g V. 03 – 12/06/2013 24 ©Velleman nv DVM171THD 2. 3. V. 03 – 12/06/2013 25 ©Velleman nv DVM171THD 4. 5. 26 ©Velleman nv 6. 1x 2x 1x 2x V. 03 – 12/06/2013 27 ©Velleman nv DVM171THD 1x 2x 7. 8. V. 03 – 12/06/2013 28 ©Velleman nv DVM171THD 9. Temperatur V. 03 – 12/06/2013 29 DVM171THD Temperaturgenauigkeit V. 03 – 12/06/2013 30 ©Velleman nv DVM171THD INSTRUKCJA OBSŁUGI 1. Wstęp 2. 3. 4. V. 03 – 12/06/2013 31 ©Velleman nv 5. 32 ©Velleman nv 6. 1x 2x 1x 2x 1x 2x V. 03 – 12/06/2013 33 ©Velleman nv 7. 8. V. 03 – 12/06/2013 34 ©Velleman nv DVM171THD 9. V. 03 – 12/06/2013 0 – 100 % ± 5,0 % ± 5,0 % ± 3,5 % ± 3,0 % ± 3,5 % ± 5,0 % 35 ©Velleman nv DVM171THD temperatura dokładność temperatury V. 03 – 12/06/2013 36 ©Velleman nv Velleman® Service and Quality Warranty Since its foundation in 1972, Velleman® acquired extensive experience in the electronics world and currently distributes its products in over 85 countries. All our products fulfil strict quality requirements and legal stipulations in the EU. In order to ensure the quality, our products regularly go through an extra quality check, both by an internal quality department and by specialized external organisations. If, all precautionary measures notwithstanding, problems should occur, please make appeal to our warranty (see guarantee conditions). General Warranty Conditions Concerning Consumer Products (for EU): • All consumer products are subject to a 24-month warranty on production flaws and defective material as from the original date of purchase. • Velleman® can decide to replace an article with an equivalent article, or to refund the retail value totally or partially when the complaint is valid and a free repair or replacement of the article is impossible, or if the expenses are out of proportion. You will be delivered a replacing article or a refund at the value of 100% of the purchase price in case of a flaw occurred in the first year after the date of purchase and delivery, or a replacing article at 50% of the purchase price or a refund at the value of 50% of the retail value in case of a flaw occurred in the second year after the date of purchase and delivery. • Not covered by warranty: - all direct or indirect damage caused after delivery to the article (e.g. by oxidation, shocks, falls, dust, dirt, humidity...), and by the article, as well as its contents (e.g. data loss), compensation for loss of profits; - consumable goods, parts or accessories that are subject to an aging process during normal use, such as batteries (rechargeable, non-rechargeable, built-in or replaceable), lamps, rubber parts, drive belts... (unlimited list); - flaws resulting from fire, water damage, lightning, accident, natural disaster, etc.…; - flaws caused deliberately, negligently or resulting from improper handling, negligent maintenance, abusive use or use contrary to the manufacturer’s instructions; - damage caused by a commercial, professional or collective use of the article (the warranty validity will be reduced to six (6) months when the article is used professionally); - damage resulting from an inappropriate packing and shipping of the article; - all damage caused by modification, repair or alteration performed by a third party without written permission by Velleman®. • Articles to be repaired must be delivered to your Velleman® dealer, solidly packed (preferably in the original packaging), and be completed with the original receipt of purchase and a clear flaw description. • Hint: In order to save on cost and time, please reread the manual and check if the flaw is caused by obvious causes prior to presenting the article for repair. Note that returning a non-defective article can also involve handling costs. • Repairs occurring after warranty expiration are subject to shipping costs. • The above conditions are without prejudice to all commercial warranties. The above enumeration is subject to modification according to the article (see article’s manual).">
Download
Advertisement
Key features
Memory for 32,000 readings
Dew point indication
USB interface for setup and data download
User-programmable alarm thresholds
Long battery life
Frequently asked questions
Either logging is not active or the battery is low. Start logging or replace the battery.
The green REC LED blinks when logging is active and no alarm has been triggered.
The red ALM LED blinks when an alarm is triggered, e.g. when a humidity threshold has been exceeded.