Phase
Action
ENGLISH
EVOSTA2
1
Unscrew the cable gland nut and extract the terminal board from the connector.
2
Remove the retaining screw.
3
Fit nut and connector on the cable.
Strip the wires as indicated in the figure. Connect the wires to the terminal board, respecting the phase, neutral and earth.
Illustration
Phase
Action
4
Insert the wired terminal board in the cable gland.
Screw on the locking nut.
5
Connect the wired connector to the pump and tighten the retaining screw.
Illustration
10.
START
Table 5: Mounting the Evosta2 connector
All the starting operations must be performed with the cover of the EVOSTA2, EVOSTA3 control panel closed.
Start the system only when all the electrical and hydraulic connections have been completed.
Avoid running the circulator when there is no water in the system.
As well as being at a high temperature and pressure, the fluid in the system may also be in the form of steam. DANGER OF SCALDING!
It is dangerous to touch the circulator. DANGER OF SCALDING!
42