Appendix D: System Electromagnetic Emissions and Immunity Declarations. Stinger Medical MC2 26 Amp-Hour, MC2 35 Amp-Hour, MC2, MC2 POWER SYSTEMS
Hirdetés
Hirdetés
MC
2
Power Systems User's Guide Appendix D: System Electromagnetic Emissions and Immunity Declarations
Appendix D: System Electromagnetic Emissions and Immunity Declarations
MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS.
WARNING: Use of unapproved ACCESSORIES may result in degradation which may result in increased Emissions and decreased Immunity.
Table 201 – Guidance and manufacturer’s declaration – electromagnetic emissions – for all EQUIPMENT and SYSTEMS (see 6.8.3.201 a)3))
November 2006
1110227 Revision 2
45
Appendix D: System Electromagnetic Emissions and Immunity Declarations MC
2
Power Systems User's Guide
Table 202 – Guidance and manufacturer’s declaration – electromagnetic immunity – for all EQUIPMENT and SYSTEMS (see 6.8.3.201 a)6))
November 2006
1110227 Revision 2
46
MC
2
Power Systems User's Guide Appendix D: System Electromagnetic Emissions and Immunity Declarations
Table 204 – Guidance and manufacturer’s declaration – electromagnetic immunity – for
EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING (see 6.8.3.201 b))
Guidance and manufacturer’s declaration – electromagnetic immunity
The MC
2
Series is intended for use in the electromagnetic environment specified below. The customer or the user of the MC
2
Series should assure that it is used in such an environment.
Immunity test
IEC 60601 test level
Compliance level
Electromagnetic immunity - guidance
Conducted
RF IEC
61000-4-6
Radiated RF
IEC 61000-4-
3
3 Vrms
150 kHz to 80
MHz
3 V/m
80 MHz to 2.5
GHz
3 V
3 V/m
Portable and mobile RF communications equipment should be used no closer to any part of the MC
2
Series, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Recommended separation distance
d = [3.5/V
1
]e P
d = [3.5/E
1
]e P 80 MHz to 800 MHz
d = [7/E
1
]e P 800 MHz to 2.5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters
(m).
Field strengths from fixed RF transmitters, as determined by an electromagnetic site a survey, should be less than the compliance level in each frequency range. b
Interference may occur in the vicinity of equipment marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the MC
2
Series is used exceeds the applicable RF compliance level above, the MC
2
Series should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the MC
2
Series.
November 2006
1110227 Revision 2
47
Appendix D: System Electromagnetic Emissions and Immunity Declarations MC
2
Power Systems User's Guide b
Over the frequency range 150 kHz to 80 MHz, field strength should be less than [V
1
] V/m.
1110227 Revision 2
MC
2
Power Systems User's Guide Appendix D: System Electromagnetic Emissions and Immunity Declarations
Table 206 – Recommended separation distances between portable and mobile RF communications equipment and the EQUIPMENT or SYSTEM – for EQUIPMENT and
SYSTEMS that are not LIFE-SUPPORTING (see 6.8.3.201 b)
Recommended separation distances between portable and mobile RF communications equipment and the MC
2
Series
The MC
2
Series is intended for use in an electromagnetic environment in which RF disturbances are controlled. The customer or the user of the MC
2
Series can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the MC
2
Series as recommended below, according to the maximum output power of the communications equipment.
Rated maximum output power of transmitter
W
Separation distance according to frequency of transmitter m
150 kHz to 80
MHz
d = [3.5/V
1
]eP
80 MHz to 800 MHz
d = [3.5/E
1
]eP
800 MHz to 2.5 GHz
d = [7/E
1
]eP
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
November 2006
1110227 Revision 2
49
Appendix D: System Electromagnetic Emissions and Immunity Declarations MC
2
Power Systems User's Guide
November 2006
1110227 Revision 2
50
Letöltés