Wired Signal Circuit Option
1:49
FRI OCT 3 2014
American Time
800-328-8996
Wired Signal Circuit Installation
To install wired signal circuits (for electrical device control including bells, tone generators, lights, etc.):
1. Disconnect and lock out power to the AllSync IQ Master and any circuit wiring.
2. Remove the terminal block cover from the AllSync IQ.
a. Remove screws from each side of the cover.
b. Lift the cover up off the unit.
3. Route signal circuit wires into the wiring compartment of the System Controller.
1:49 :45
AM
FRI OCT 3 2014
American Time
800-328-8996
a. Remove knockout(s).
b. Use copper conductors only.
c. Use strain relief connector fittings in the knockout holes to secure the wires.
d. Route the wires into the wiring compartment, leaving enough slack to make all connections to the relay terminals.
4. Connect signal wires to the circuit relay terminals.
a. Route the power (feed) line of each circuit to the COM terminal of the desired circuit (1-6) being connected.
b. Route the switched (load) line of each circuit to the NO terminal of the desired circuit (1-6) being connected.
c. Label the wires for each circuit as desired.
n Note: The signal circuits are protected with surge suppression components. In some applications, this protection can cause leakage current to trigger the output device(s) when the circuit is switched ON. In these cases, the surge protection switches
(see illustration below) can be moved to the OFF position. Contact American Time Technical Support at 800-328-8996 with any questions.
AllSync IQ Master Wiring Compartment Diagram
H N
NO COM
CLOCK 1
NC NO COM
CLOCK 2
NC NO
BELL 1
COM NO
BELL 2
COM NO
BELL 3
COM NO
BELL 4
COM NO
BELL 5
COM NO
BELL 6
COM
= Bell
= Light
FUSED
POWER
SOURCE
BLACK
WHITE
LOW VOLTAGE
DEVICES
STEP DOWN
TRANSFORMER
14
© American Time
advertisement
Related manuals
advertisement
Table of contents
- 4 Introduction
- 10 Ethernet Installation
- 12 Wired Clock Circuit Option
- 14 Wired Signal Circuit Installation
- 15 Wired Signal Circuit Programming
- 24 Remote Connect Web Interface-10 pages
- 32 Settings & Configurations
- 38 Troubleshooting Wired Clock Circuit
- 37 Troubleshooting Remote Connect
- 35 Troubleshooting GPS
- 41 Appendix A: Ethernet Timekeeping
- 44 Appendix D: Wired Signal Circuit Programming Examples
- 47 Appendix E: Checking IQ System Controller Status Information
- 48 Appendix H: Maintenance Guide
- 50 Appendix I: Clock Circuit Wiring Diagrams-5 pages
- 56 Glossary