MS+UPN. Aastra OpenCom 510
Anúncio
Anúncio
Modules MS+UPN1-8
The LEDs indicate the following:
LED 1: Constantly yellow
LED 2: Constantly green
Flashing yellow
Constantly red
LED 3: Constantly green
LED 4: Constantly yellow
At least one connection established through the interface card is active.
The interface card is operational; the slot has been activated (flickering is normal).
The interface card is ready, but the slot has not been activated or the interface card has not been configured yet.
New software is being loaded onto the interface card. If the LED lights up red for an extended period of time, there may be a fault.
The interface card is providing the system clock signal (indicated only in the master system and only on an interface card).
The interface card is running a combination of subscriber and trunk connections, i.e. both internal and external S
0
interfaces have been configured.
Operational Information
The MX+S01-8 interface card can be exchanged during operation, i.e. without powering down the system. However, the slot must first be deactivated in the
Configurator in the web console (see
Installing Interface Cards starting on page 31).
All three protocol layers can be individually configured as master or slave for each
S
0
interface.
The S
0
interfaces can be configured as DSS1-PP, DSS1-PMP or Q.SIG lines.
7.7
MS+UPN1-8
Field of Application
The MS+UPN1-8 interface card provides eight U pn
interfaces for connecting system terminals; however, it is not possible to connect DECT base stations.
73
Modules MS+UPN1-8
The MS+UPN1-8 interface card can be installed in any of the slots (1 to 12) of the
OpenCom 510 (see
Technical Information
■ The MS+UPN1-8 interface card can also be installed in a slave system.
■ No settings need to be made on the MS+UPN1-8 interface card.
■ The MS+UPN1-8 interface card runs on software acquired from the system.
After the card has been installed it will automatically load the required software.
Pin Assignment
RJ45 Connector Pin Assignment for the MS+UPN1-8 Interface
6
7
4
5
8
2
3
Pin Number Assignment
1 Not used
Not used
Not used
U
U pn pn
a
b
Not used
Not used
Not used
Indicators
There are four LEDs on the front of the MS+UPN1-8 interface card.
74
Modules
1
2
MS+UPN1-8
3
4
MS+UPN1-8
MS+UPN1-8
The LEDs indicate the following:
LED 1: Constantly yellow
LED 2: Constantly green
Flashing yellow
Constantly red
LED 3: –
LED 4: –
At least one connection established through the interface card is active.
The interface card is operational; the slot has been activated (flickering is normal).
The interface card is ready, but the slot has not been activated or the interface card has not been configured yet.
New software is being loaded onto the interface card. If the LED lights up red for an extended period of time, there may be a fault.
Not used
Not used
Operational Information
The MS+UPN1-8 interface card can be exchanged during operation, i.e. without powering down the system. However, the slot must first be deactivated in the
Configurator in the web console (see
Installing Interface Cards starting on page 31).
The short-circuit-proof feed voltage is – 42 V.
75
Modules MS+UPN2-8
7.8
MS+UPN2-8
Field of Application
The MS+UPN2-8 interface card provides eight U pn system terminals and DECT base stations.
interfaces for connecting
The MS+UPN2-8 interface card can be installed in any of the slots (1 to 12) of the
OpenCom 510 (see
Technical Information
■ The MS+UPN2-8 interface card can also be installed in a slave system.
■ A maximum of 48 RFPs (Radio Fixed Parts, DECT base stations) can be connected to the entire system.
■ In order to connect RFPs, U pn
ports 1+2, 3+4, 5+6 or 7+8 can be combined by setting the DIP switches on the card accordingly.
For further information, refer to
Upn Ports starting on page 45.
■ The MS+UPN2-8 interface card runs on software acquired from the system.
After the card has been installed it will automatically load the required software.
Pin Assignment
For information on the U pn
interface pin assignment, refer to
Indicators
There are four LEDs on the front of the MS+UPN2-8 interface card.
76
Modules
1
2
MS+UPN2-8
3
4
MS+UPN2-8
MS+UPN2-8: LEDs
The LEDs indicate the following:
LED 1: Constantly yellow
LED 2: Constantly green
Flashing yellow
Constantly red
At least one connection established through the interface card is active.
The interface card is operational; the slot has been activated (flickering is normal).
The interface card is ready, but the slot has not been activated or the interface card has not been configured yet.
New software is being loaded onto the interface card. If the LED lights up red for an extended period of time, there may be a fault.
Not used
Not used
LED 3: –
LED 4: –
Operational Information
The MS+UPN2-8 interface card can be exchanged during operation, i.e. without powering down the system. However, the slot must first be deactivated in the
Configurator in the web console (see
Installing Interface Cards starting on page 31).
77
Modules MS+A1-8
7.9
MS+A1-8
Field of Application
The MS+A1-8 interface card provides eight analogue interfaces for connecting analogue terminals.
The MS+A1-8 interface card can be installed in any of the slots (1 to 12) of the
OpenCom 510 (see
Technical Information
■ The MS+A1-8 interface card can also be installed in a slave system.
■ The MS+A1-8 interface card supports pulse dialling as well as dual-tone multifrequency (DTMF) dialling. The central receivers of the MC+1-3 interface card are used for DTMF recognition.
■ Calling line identification presentation (CLIP) is supported.
■ The consultation feature can be selected by means of a flash key and/or earthing key.
■ The MS+A1-8 interface card runs on software acquired from the system. After the card has been installed it will automatically load the required software.
■ No settings need to be made on the MS+A1-8 interface card.
Pin Assignment
For information on the a/b interface pin assignment, refer to
a/b Ports starting on page 48.
Indicators
There are four LEDs on the front of the MS+A1-8 interface card.
78
Modules
1
2
MS+A1-8
3
4
MS+A1-8
MS+A1-8: LEDs
The LEDs indicate the following:
LED 1: Constantly yellow
LED 2: Constantly green
Flashing yellow
Constantly red
LED 3: –
LED 4: –
At least one connection established through the interface card is active.
The interface card is operational; the slot has been activated (flickering is normal).
The interface card is ready, but the slot has not been activated or the interface card has not been configured yet.
New software is being loaded onto the interface card. If the LED lights up red for an extended period of time, there may be a fault.
Not used
Not used
Operational Information
The MS+A1-8 interface card can be exchanged during operation, i.e. without powering down the system. However, the slot must first be deactivated in the Configurator in the web console (see
Installing Interface Cards starting on page 31).
79
Modules MS+A1-4
7.10
MS+A1-4
Field of Application
The MT+A1-4 provides interface card four analogue interfaces for connecting analogue trunk lines.
The MT+A1-4 interface card can be installed in any of the slots (1 to 12) of the
OpenCom 510 (see
Technical Information
■ The MT+A1-4 interface card can also be installed in a slave system.
■ The MT+A1-4 interface card supports pulse dialling as well as dual-tone multifrequency (DTMF) dialling.
■ Ringing tone detection works at 16
2
/
3
, 25 or 50 Hz. The analogue network terminations are electrically isolated. The country-specific adaption is made by the operating software.
■ Calling line identification presentation (CLIP), the consultation feature by means of a flash key and/or earthing key and the transmission of call data charges are not supported.
■ The MT+A1-4 interface card runs on software acquired from the system. After the card has been installed it will automatically load the required software.
■ No settings need to be made on the MT+A1-4 interface card.
Pin Assignment
For information on the a/b interface pin assignment, refer to
a/b Ports starting on page 48.
Indicators
There are four LEDs on the front of the MT+A1-4 interface card.
80
Modules
1
2
MT+A1-4
3
4
MS+A1-4
MT+A1-4: LEDs
The LEDs indicate the following:
LED 1: Constantly yellow
LED 2: Constantly green
Flashing yellow
Constantly red
LED 3: –
LED 4: –
At least one connection established through the interface card is active.
The interface card is operational; the slot has been activated (flickering is normal).
The interface card is ready, but the slot has not been activated or the interface card has not been configured yet.
New software is being loaded onto the interface card. If the LED lights up red for an extended period of time, there may be a fault.
Not used
Not used
Operational Information
The MT+A1-4 interface card can be exchanged during operation, i.e. without powering down the system. However, the slot must first be deactivated in the Configurator in the web console (see
Installing Interface Cards starting on page 31).
81
Download
Anúncio