Using the StandardDigital LED Operator. YASKAWA iQpump Micro CIMR-PW Series
বিজ্ঞাপন
বিজ্ঞাপন
5
6
7
8
9
10
11
12
13
14
15
No.
1
2
3
4
4.4 Using the Standard Digital LED Operator
4.4 Using the Standard Digital LED Operator
Use the LED operator to enter run and stop commands, display data, edit parameters, as well as display fault and alarm information.
u
Keys, Displays, and LEDs
11
12
1 5
13
9
Display
AUTO
OFF
HAND
AUTO
HAND
2
3
HAND
15
14
AUTO OFF
16
10
7
8
4 6
Table 4.1 Keys and Displays on the LED Operator
Name Function
Data Display Area Displays the setpoint, frequency reference, parameter number, etc.
ESC Key
RESET Key
AUTO Key
Up Arrow Key
Down Arrow Key
OFF Key
ENTER Key
HAND Key
Returns to the previous menu.
Moves the cursor to the right.
Resets the drive to clear a fault situation.
Selects the source of Run command and frequency reference.
• Set the drive to AUTO mode.
• Run command input source depends on b1-02.
• Frequency reference input source depends on b1-01.
Scrolls up to display the next item, selects parameter numbers, and increments setting values.
Scrolls down to display the previous item, selects parameter numbers, and decrements setting values.
Follows the stopping method set in b1-03 to stop drive operation.
• Enters parameter values and settings.
• Selects a menu item to move between displays.
The drive runs at a selectable frequency reference source as set by P5-01.
• Set the drive to HAND mode.
• When P5-03 is set to 1, HAND and AUTO mode can be switched while the drive is running.
AUTO Light
Lit while the drive is in AUTO mode. Refer to page 70 for details.
HAND Light
ALM LED Light
REV LED Light
DRV LED Light
FOUT LED Light
Lit while the drive is in HAND mode. Refer to page
for details.
Refer to LED Screen Displays on page 70
.
Start-Up Programming & Operation
4
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual 69
4.4 Using the Standard Digital LED Operator
No.
Display Name
16 – Communication Port
Function
Port used for USB Copy Unit, LCD Operator Keypad, and for connecting to a PC.
NOTICE: Use only specified cable when making connections to the drive.
Failure to comply may damage the drive.
NOTICE: Do not open the port cover wider than 90 degrees. Failure to comply may break the port cover and leave the unprotected port susceptible to damage.
u
LED Screen Displays
Display Lit
When the drive detects an alarm or error
Motor is rotating in reverse
Drive Mode
Auto-Tuning
Displays output frequency (Hz)
Flashing
• When an alarm occurs
• oPE detected
• When a fault or error occurs during
Auto-Tuning
—
—
As illustrated in this manual
Off
Normal state (no fault or alarm)
Motor is rotating forward
Programming Mode
— u
AUTO LED and HAND LED Indications
AUTO LED
STOP
Table 4.2 AUTO LED and HAND LED Indications
HAND LED State
AUTO
Off
HAND
Off
OFF mode
AUTO
Off
HAND
On solid
HAND mode (Also during DC injection braking)
AUTO
Off
HAND
Long blink (50% duty)
HAND mode when the Frequency Reference is 0 and/or decelerating in HAND mode, or during PI Sleep or Snooze.
AUTO
On solid
HAND
Off
Running in AUTO mode (Also during DC injection braking)
AUTO
Off
HAND
Short blink (15% duty)
HAND mode, Ready, No Run command input.
Note: Short Blink for Legacy Operation Mode (S5-04 = 0).
AUTO
Off
HAND
Double blink
HAND mode, cycle the Run command.
AUTO
Long blink (50% duty)
HAND
Off
Running in AUTO mode when the Frequency Reference is 0 and/or decelerating in AUTO mode, or during PI Sleep or Snooze.
AUTO
Short blink (15% duty)
AUTO
Double blink
HAND
Off
HAND
Off
AUTO mode, Ready, No run command input.
AUTO mode, stopped by a Fast- Stop from a Multi-Function Digital Input.
70 YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
4.4 Using the Standard Digital LED Operator
2 s
ON
1 s
ON ON
Long blink
(50% duty)
ON ON ON ON ON ON
Double blin k
Short link
(15% duty)
ON ON
Figure 4.1 AUTO LED and HAND LED Timing Status
Output Frequency
AUTO Mode Selection
HAND Mode Selection
RUN Command
OFF
Frequency
AUTO LED
HAND LED
Operation Mode
OFF
OFF
0 Hz
Short blink
ON
6 Hz
ON
OFF
AUTO
Blink OFF
Figure 4.2 LEDs and Drive Operation in AUTO and HAND Modes
Blink OFF
Start-Up Programming & Operation
4
YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual 71
4.4 Using the Standard Digital LED Operator u
Menu Structure for Digital LED Operator
Monitor Menu
U4-01 U9-02
1.25 s
Drive Oper Time Hrs
1.25 s iQ Network Activity
U1-99
<1>
User Selected Monitor
<2>
Current Output
<3>
Output Frequency
1.25 s
Anti-No-Flow Timer
Skipped when b5-01 =0
(PID Disabled)
<4>
PID Feedback
PID Setpoint
Auto-Tuning
Parameters
Quick Setting
Modified Constants
U1-10
1.25 s
Digital Input Status
U1-11
1.25 s
Digital Output Status
U1-13
1.25 s
A1 Input Level
Home Screen:
Changes depending on
Mode
Frequency Reference
PID
Disabled not in HAND
HAND Reference
HAND Mode
1.25 s
1.25 s
PID Setpoint
PID
Enabled not in HAND
1.25 s
<1>
User Selected Monitor
1.25 s o1-01 Selected
U1-01
U1-01
U5-99
<2>
Current Output
1.25 s
<3>
Output Frequency
1.25 s
<4>
PID Feedback 1.25 s
U1-03
U1-02
U5-01
U1-14
1.25 s
A2 Input Level
Figure 4.3 Digital LED Operator Screen Structure n Home Quick Monitor Display (LED)
The Home Quick Monitor provides an easily accessible preset group of monitors that are frequently used during operation.
FREF or SETPT - U1-01, Frequency Reference, or U5-99, AUTO Setpoint
FEEDB - U1-91, PID Feedback
F-OUT - U1-02, Output Frequency
I-OUT - U1-03, Output Current
USER - Selected Monitor via o1-01 (defaulted to U1-06 Output Voltage)
The following monitors are available via the Quick Monitor:
Monitor
U1-10
U1-11
U1-13
U1-14
Name
Input Terminal Status
Output Terminal Status
Terminal A1 Level
Terminal A2 Level
Monitor
U4-01
U9-02
U1-99
Name
Drive Elapsed Time iQ Network Activity
Anti-No-Flow Timer
When navigating through the preset monitors at the Main Menu or the Quick Monitors, a 5-character descriptive text appears briefly before showing the monitor values.
When viewing a Quick Monitor value, press ENTER to re-display the 5-character descriptive text for a brief time. Press ESC when the Quick Monitor value is displayed to jump to the U1-01, Frequency Reference/U5-99, AUTO Setpoint, monitor.
The PID Setpoint unit is animated with alternating “P” and “S”. The PID Setpoint unit is not shown when the value rises above
4 digits or when in Non-MOP parameter entry mode (Q1oo to U5-99)
The PID Feedback unit is animated with a P alternating with a rising level. The PID Feedback unit is not shown when the value rises above 4 digits.
72 YASKAWA TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual