Navigating In Windows Embedded CE. Psion GM37527RA2041, GM375273RADA

Add to My manuals
200 Pages

advertisement

Navigating In Windows Embedded CE. Psion GM37527RA2041, GM375273RADA | Manualzz

W

ORKING

W

ITH

W

INDOWS

E

MBEDDED

CE 5.0

4

4.1 Navigating In Windows Embedded CE 5.0 . . . . . . . . . . . . . . . . . . 57

4.1.1 Navigating Using A Touchscreen And Stylus . . . . . . . . . . . . 57

4.1.2 Navigating Using The Keyboard . . . . . . . . . . . . . . . . . . . 57

4.2 Working With Files, Folders And Programs . . . . . . . . . . . . . . . . . . 58

4.3 The Startup Desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

4.3.1 The Desktop Icons . . . . . . . . . . . . . . . . . . . . . . . . . . 60

4.3.2 The Taskbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

4.3.2.1 Using The Taskbar . . . . . . . . . . . . . . . . . . . . . . 61

4.3.2.2 Customizing The Taskbar . . . . . . . . . . . . . . . . . . 62

4.4 The Start Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

4.4.1 The Desktop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

4.4.2 Security Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

4.4.3 Programs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

4.4.4 Shortcuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

4.4.5 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69

4.4.6 Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

4.4.7 Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71

4.5 Using A Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 55

Chapter 4: Working With Windows Embedded CE 5.0

Navigating In Windows Embedded CE 5.0

4.1 Navigating In Windows Embedded CE 5.0

Note: In order to access many of the menus discussed in this chapter, the security level must be set to ‘Supervisor’ (see “Security Settings” on page 64).

Graphic user interfaces like Windows Embedded CE 5.0 for portable devices and desktop Windows (2000, XP, etc.) utilize ‘point and click’ navigation. An equivalent keyboard shortcut is also available for every ‘point and click’ action.

Windows Embedded CE 5.0 supports the same ‘point and click’ user interface and keyboard shortcuts as desktop Windows with one difference—the ‘point and click’ action is accomplished using a touchscreen rather than a mouse. Actions can be performed using any combination of keyboard shortcuts or touchscreen tapping.

4.1.1 Navigating Using A Touchscreen And Stylus

Note: If the touchscreen is not registering your screen taps accurately, the touchscreen may need recalibration. Refer to “Calibrating The Touchscreen” on page 45.

Each WORKABOUT PRO G2 is equipped with a stylus —a pointing tool that looks like a pen—stored in a slot at the top of the unit. The stylus is used to select objects on the touchscreen.

Note: To prevent damage to the touchscreen, use only the stylus (pen) supplied with your WORKABOUT PRO G2.

To choose an icon, open a file, launch an applet or open a folder:

• Double-tap the stylus on the appropriate icon.

4.1.2 Navigating Using The Keyboard

If your WORKABOUT PRO G2 touchscreen has been disabled, you can use the keyboard to choose icons, navigate dialog boxes, display the desktop, and so on. If your unit has already been fully configured and your application is launched at startup, you’ll have little need for keyboard navigation, but you can refer to

Table 4.1 on page 58 for a description of the navigation keys.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 57

Chapter 4: Working With Windows Embedded CE 5.0

Working With Files, Folders And Programs

Operation

Switch between active applications

Key or Key Combination

[ALT] [TAB]

Open task manager

Move the cursor

Open file, folder or icon

Exit & Save

Close/Exit & Do Not Save

Navigate Dialog Boxes

Select Radio Button/Press Button

Go to Start Menu

[ALT] [ESC]

Arrow keys

[ENTER]

[ENTER]

[ESC]

[TAB]

To move cursor up [SHIFT] [TAB]

To display the contents of the next ‘tab’ in a dialog box [CTRL] [TAB]

[SPACE]

[BLUE][0]

Table 4.1 Keyboard Navigation

Keep in mind that unlike a desktop computer, the WORKABOUT PRO G2 does not support key chording (pressing two keys at the same time). You must press one key followed by the next in sequence. Refer to “Working With Files, Folders And

Programs” for additional details about keyboard navigation.

4.2 Working With Files, Folders And Programs

Folder

Program Icon

Figure 4.1 Working With Windows Icons

File

58 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 4: Working With Windows Embedded CE 5.0

The Startup Desktop

• Double-tap on the appropriate icon—either a folder icon, a program icon or a file icon—to open or launch your selection.

If you’re using the keyboard:

• Use the arrow keys to highlight the icon you want to open or launch.

• Press [ENTER].

4.3 The Startup Desktop

When the WORKABOUT PRO G2 boots up, the startup desktop (shell) is displayed. Any applications stored in the Startup folder start up immediately.

Note: The startup folder is located in \Windows\StartUp and

\Flash Disk\StartUp.

Figure 4.2 The WORKABOUT PRO G2 Startup Desktop

To access desktop icons:

• Double-tap on the icon to open a window or, in the case of an application icon, launch an application.

On the keyboard:

• Use the arrow keys to highlight the icon, and press [ENTER] to launch the highlighted icon.

Note: If the arrow keys do not highlight the desktop icons, the desktop may not be selected. Press [FN/BLUE] [.] (period) to display the Start Menu, and

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 59

Chapter 4: Working With Windows Embedded CE 5.0

The Desktop Icons select Desktop. Now the desktop will be “in focus” and the arrow keys will highlight the icons.

4.3.1 The Desktop Icons

The icons displayed in the startup desktop operate in much the same way as those displayed on any standard PC desktop that is running Windows.

My Device

Choosing this icon displays the contents of your WORKABOUT PRO G2 computer. If you’re not sure how to work with the files, folders and programs displayed, refer to “Working With Files, Folders And Programs” on page 58.

Recycle Bin

This option temporarily stores items that were deleted, allowing you to either permanently delete or restore these items.

Internet Explorer

Choosing this icon launches Internet Explorer—a standard Windows Embedded CE

5.0 version. Keep in mind that your supervisor will need to set up access using the

Internet Options and the Network and Dial-up Connections icons in the Control

Panel .

Remote Desktop Connection

This option allows your WORKABOUT PRO G2 to communicate with a remote desktop PC. “Remote Connect” on page 81 provides a website with step-by-step instructions.

60 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

4.3.2 The Taskbar

Chapter 4: Working With Windows Embedded CE 5.0

The Taskbar

Figure 4.3 The Taskbar

The WORKABOUT PRO G2 is equipped with a taskbar at the bottom of the screen.

It displays icons through which you can view the battery capacity and radio signal quality of your unit. If the hand-held is attached to a charger, cradle, docking station or PDM, an associated icon is displayed. In addition, the taskbar displays the application(s) currently running on your unit and the security level assigned to your

WORKABOUT PRO G2.

The taskbar also displays active modifier keys: [SHIFT], [ALT], [CTRL],

[FN/BLUE] and [FN/ORANGE]. Keys that have been locked “on” are displayed in uppercase letters. For example, if you have set the [CTRL] key Lock to “on” in the

Keyboard menu and you press the key, it is displayed as CTRL KEY in the taskbar. (For detailed information on modifier keys and keyboard options, see “The Keyboard” on page 39).

4.3.2.1

Using The Taskbar

A tooltip is displayed as each taskbar icon is highlighted. The tooltip provides the status of each icon.

If you’re using the touchscreen:

• Tap and hold the stylus on an icon to display the icon's tooltip. Double-tap the icon to open the Control Panel dialog box associated with the icon. For example, double-tap the battery icon to display a dialog box listing the current battery capacity information.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 61

Chapter 4: Working With Windows Embedded CE 5.0

The Taskbar

On the keyboard:

• Press [FN/BLUE] [.] (period) to display the Start Menu .

• Choose Shortcuts from the Start Menu , and then press the [RIGHT] arrow key to display the sub-menu.

• Choose System Tray in the sub-menu.

• Use the arrow keys to highlight the icon in the taskbar about which you’d like more information.

• Press [ENTER] to display the appropriate dialog box.

4.3.2.2

Customizing The Taskbar

To customize the taskbar so that it displays only those icons you require:

• In the Start Menu , choose Settings , and then Taskbar .

If you’re using the keyboard:

• Press [BLUE] [0] (zero) to display the Start Menu .

• Highlight the Settings option, highlight Taskbar in the sub-menu, and press [ENTER].

The Taskbar and Start Menu dialog box is displayed.

Figure 4.4 Taskbar And Start Menu Settings

• Tap the stylus on the items you want to activate or deactivate. The check mark indicates active items.

If you’re using the keyboard:

• Highlight the options you want to activate, and press the [SPACE] key to select them. A check mark indicates active items.

62 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 4: Working With Windows Embedded CE 5.0

The Start Menu

4.4 The Start Menu

Note: Some of the Start Menu items may be disabled based on the current

WORKABOUT PRO G2 security settings.

The Start Menu lists the operations you can access and work with. It is available from the startup desktop or from within any application.

To display the menu:

• Press [FN/BLUE] [.] (period).

Note: Tap on the item in the menu with which you want to work.

Figure 4.5 Start Menu

If you’re using the keyboard:

• Use the arrow keys to highlight a menu item, and press [ENTER], or

If the menu item has an underlined character:

• Type the underlined alpha character. For example, to display the Security dialog box, type the letter ‘ s ’ .

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 63

Chapter 4: Working With Windows Embedded CE 5.0

The Desktop

4.4.1 The Desktop

Choosing the Desktop option from the Start Menu displays the WORKABOUT

PRO G2 desktop.

Figure 4.6 WORKABOUT PRO G2 Desktop

4.4.2 Security Settings

Choosing the Security option from the Start Menu displays a dialog box in which you can define the access level for the WORKABOUT PRO G2: Supervisor or

User.

Figure 4.7 Security Levels

64 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 4: Working With Windows Embedded CE 5.0

Security Settings

Assigning The Supervisor Security Level

The security level is represented by an icon in the shape of a lock in the taskbar. The security levels define the options accessible to the operator in the Start Menu and the taskbar . By default, the security level is set to User , restricting access to only the most basic Start Menu items.

To allow access to all the Start Menu and taskbar options:

• In the Security Level dialog box, tap on the radio button next to Supervisor.

• In the Password field, type the Supervisor level password. The default password is 123456.

• Tap on OK . You can now access all menu items in the Start Menu along with the icons in the taskbar.

Changing A Password

Note: Keep in mind that this is the same password as that assigned through the Password control panel applet. Refer to “Control Panel Icons” on page 83.

To assign a password:

• Choose a security level , and enter the existing password in the Password field.

• Tap on the Set Password button.

A dialog box labelled Password Properties is displayed.

• Type the new password in the Password: text box (all keyboard characters are valid).

• In the Confirm Password: text box, retype the new password.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 65

Chapter 4: Working With Windows Embedded CE 5.0

Programs

Configuring Security

Choosing the Configure button displays the Configure Security dialog box.

Figure 4.8 Configuring Security

This dialog box allows you to determine which security levels will have an associated icon displayed in the taskbar. By default, a security icon is not displayed for user-level security.

Note: It is recommended that you enable ‘Allow Teklogix Security Level’ so that authorized Psion Teklogix service personnel can access your unit should it require maintenance.

4.4.3 Programs

• Choose Programs to display a sub-menu of options.

Figure 4.9 Program Sub-Menu

66 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 4: Working With Windows Embedded CE 5.0

Programs

ActiveSync®

This option allows you to connect to another device using ActiveSync.

Demo

This folder contains the Demo Imager , Demo Scanner , and Demo Signature applications. Demo Imager is used for simple image-capturing purposes and for displaying bar code data and bar code statistics on the same screen with image data and information. Demo Scanner can be used to test how the hand-held reads and writes RFID tags. Demo Signature allows you to capture a signature written on the screen with your stylus and save it to a file.

Summit

This folder provides access to the Summit Client Utility (SCU), a utility that allows you to configure your Summit 802.11g radio, model number RA2041.

Command Prompt

Command Prompt is used to access the DOS command prompt. At the prompt, you can type DOS commands such as dir to display all the directories in the drive.

Internet Explorer

The WORKABOUT PRO G2 is equipped with Microsoft Internet Explorer for

Windows Embedded CE 5.0. You can access the Internet Options icon through the

Start Menu under Settings, Control Panel or by double-tapping on the desktop

Internet Explorer icon.

Remote Connect

Remote Connect is a WORKABOUT PRO G2 application used to connect to a

Windows Terminal Server so that you can run a “session” on the Server machine using the WORKABOUT PRO G2 (Windows Embedded CE 5.0 device). “Remote

Connect” on page 81 provides a website with details about this option.

Windows Explorer

The Windows Explorer installed on your WORKABOUT PRO G2 is consistent with all Windows Embedded CE 5.0 devices. You can access this option from the

Start Menu under Programs, Windows Explorer .

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 67

Chapter 4: Working With Windows Embedded CE 5.0

Shortcuts

4.4.4 Shortcuts

Figure 4.10 Shortcuts Sub-Menu

System Tray

If your touchscreen is not enabled, you can use the System Tray option to access the icons in the taskbar at the bottom of the screen. The taskbar displays indicators such as a radio signal icon and the security level. These indicators are attached to dialog boxes that provide additional information.

• Choose Shortcuts>System Tray .

When System Tray is chosen, the taskbar icons become accessible. To display the dialog box attached to an icon:

• Use the arrow keys to highlight an icon, for example, the security icon.

• Press [ENTER] to display the security level dialog box.

Cycle Tasks

When Cycle Tasks is selected (and the Task Manager is not open), you can cycle through active applications.

To cycle through your active applications:

• Choose Shortcuts>Cycle Tasks , or

Press [ALT] [TAB].

68 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 4: Working With Windows Embedded CE 5.0

Settings

Task Manager

The Task Manager allows you to switch to another task or to end an active task. To display the task manager window:

• Tap on Shortcuts>Task Manager , or

Press [ALT] [ESC].

Figure 4.11 Task Manager

4.4.5 Settings

The Settings sub-menu includes the following settings: Control Panel , Network and Dial-up Connections and Taskbar and Start Menu .

Figure 4.12 Settings Sub-Menu

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 69

Chapter 4: Working With Windows Embedded CE 5.0

Run

Control Panel

The Control Panel contains applets used to configure hardware, the operating system and the shell. If your WORKABOUT PRO G2 is running with the Psion

Teklogix TekTerm application or another application, additional configuration applets may appear in the Control Panel .

Network And Dial-Up Connections

The Network and Dial-up Connections window allows you to configure the

WORKABOUT PRO G2 radio or execute an existing configuration. Refer to

“Configuring Your Radio” on page 13 for radio setup details.

Taskbar And Start Menu

The Taskbar and Start Menu option displays a dialog box in which you can customize the taskbar, choosing which options will be displayed. Refer to

“Customizing The Taskbar” on page 62 for additional details about this option.

4.4.6 Run

Choosing the Run option from the Start Menu displays a dialog box in which you can enter the name of the program, folder or document you want to open or launch.

Figure 4.13 Run Dialog Box

70 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 4: Working With Windows Embedded CE 5.0

Shutdown

4.4.7 Shutdown

The Shutdown menu includes these options: Suspend, Warm Reset and Cold Reset .

Figure 4.14 Shutdown Sub-Menu

Note: This menu varies slightly depending on the security level chosen. When the WORKABOUT PRO G2 is set to User level , the Shutdown option is replaced by Suspend . A sub-menu is not available.

Suspend

The Suspend option suspends the WORKABOUT PRO G2 immediately. This is equivalent to turning the hand-held off.

Warm Reset

The Warm Reset option resets the WORKABOUT PRO G2, leaving all saved files and (registry) settings intact. Any unsaved data is lost.

Cold Reset

The Cold Reset option resets the WORKABOUT PRO G2 (see page 31). Any files not stored in permanent memory are lost; however, the registry settings are saved.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 71

Chapter 4: Working With Windows Embedded CE 5.0

Using A Dialog Box

4.5 Using A Dialog Box

A dialog box (like the samples in Figure 4.15) appears when you need to make selections and enter further information. You can move between dialog items by tapping on them with your stylus, or by pressing the arrow keys and the [TAB] key

([SHIFT] [TAB] moves the cursor backwards).

Tabs

Radio

Button

Textbox

Checkbox

Drop-down Menu

Button

Figure 4.15 Dialog Boxes

Note: You can use the stylus to tap on an element in a dialog box to select or deselect it, display drop-down menu items, save your selections, and so on.

Dialog boxes contain one or more of the following elements:

Tab : A tab separates different elements of a dialog box. Press the [TAB] key until a tab in the dialog box is highlighted. To display adjoining tabs, press the [RIGHT] or

[LEFT] arrow key. To display the information in the next tab from anywhere in the window, press [CTRL] [TAB].

Textbox: A textbox requires that you type information. Press the [TAB] key to highlight the textbox and then type the appropriate information.

Drop-down: This type of menu is identified by up and down arrows next to the drop-down menu to indicate that additional options are available. Press the [TAB] key to highlight the menu, and use the arrow keys on your keyboard to cycle through the options.

72 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 4: Working With Windows Embedded CE 5.0

Using A Dialog Box

Checkbox: This box allows you to select or deselect an option. To select or deselect a checkbox, press the [TAB] key to highlight the checkbox, and press the [SPACE] key to select or deselect it.

Radio buttons: These buttons allow you to choose from a number of options. For example, in the sample screen in Figure 4.15 on page 72 you can choose to Obtain an IP address via DHCP or Specify an IP address . Press the [TAB] key to highlight a radio button option, and then select a radio button by pressing the arrow keys to highlight the appropriate option.

Buttons: This type of button allows you to Save , Delete and so on the options you’ve chosen in a dialog box. Use the [TAB] key to highlight the button you want to use. Press the [ENTER] key to activate it.

Saving Your Choices: Once you’ve made all your changes, press the [ENTER] key to save your changes and exit the window.

Note: A dialog box item that is displayed in grey text indicates that it is not currently available.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 73

C

ONFIGURATION

5

5.1 Remote Connect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

5.2 The TekTerm Application . . . . . . . . . . . . . . . . . . . . . . . . . . 81

5.3 Pocket PC Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . 81

5.4 The Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

5.5 Control Panel Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83

5.6 Basic Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87

5.6.1 Display Properties . . . . . . . . . . . . . . . . . . . . . . . . . . 87

5.6.1.1 Display Backlight . . . . . . . . . . . . . . . . . . . . . . 87

5.6.1.2 Display Appearance . . . . . . . . . . . . . . . . . . . . . 89

5.6.2 Keyboard Properties . . . . . . . . . . . . . . . . . . . . . . . . . 90

5.6.2.1 Key Repeat. . . . . . . . . . . . . . . . . . . . . . . . . . 90

5.6.2.2 Keyboard Backlight . . . . . . . . . . . . . . . . . . . . . 91

5.6.2.3 Keyboard One Shot Modes . . . . . . . . . . . . . . . . . 92

5.6.2.4 Keyboard Macro Keys . . . . . . . . . . . . . . . . . . . . 93

5.6.2.5 Unicode Mapping . . . . . . . . . . . . . . . . . . . . . . 95

5.6.2.6 Scancode Remapping . . . . . . . . . . . . . . . . . . . . 97

5.6.3 Volume And Sound Properties . . . . . . . . . . . . . . . . . . . . 99

5.6.3.1 Volume Adjustments. . . . . . . . . . . . . . . . . . . . .100

5.6.4 Power Management Properties . . . . . . . . . . . . . . . . . . . .100

5.6.4.1 Battery Capacity . . . . . . . . . . . . . . . . . . . . . . .101

5.6.4.2 Power Saving Suspend. . . . . . . . . . . . . . . . . . . .101

5.6.4.3 Suspend Threshold. . . . . . . . . . . . . . . . . . . . . .102

5.6.4.4 Advanced . . . . . . . . . . . . . . . . . . . . . . . . . .103

5.6.4.5 Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . .104

5.6.5 Stylus Properties . . . . . . . . . . . . . . . . . . . . . . . . . . .104

5.6.5.1 Double-Tap . . . . . . . . . . . . . . . . . . . . . . . . .105

5.6.5.2 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . .105

5.6.5.3 Touch . . . . . . . . . . . . . . . . . . . . . . . . . . . .105

5.6.6 Manage Triggers . . . . . . . . . . . . . . . . . . . . . . . . . . .106

5.6.6.1 Trigger Mappings . . . . . . . . . . . . . . . . . . . . . .107

5.6.6.2 Add And Edit Trigger Mapping . . . . . . . . . . . . . . .108

5.6.7 Certificate Assignment . . . . . . . . . . . . . . . . . . . . . . . .110

5.7 Bluetooth Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 75

Chapter 5: Configuration

5.7.1 The Devices Tab. . . . . . . . . . . . . . . . . . . . . . . . . . . 112

5.7.2 The Servers Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

5.7.3 Outgoing Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116

5.7.4 Active Conn. Tab . . . . . . . . . . . . . . . . . . . . . . . . . . 117

5.7.5 The Properties Tab . . . . . . . . . . . . . . . . . . . . . . . . . 118

5.7.6 The Bluetooth GPRS WAN Connection . . . . . . . . . . . . . . 118

5.8 Total Recall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124

5.8.1 Creating A Backup Profile . . . . . . . . . . . . . . . . . . . . . 125

5.8.2 Restoring A Profile . . . . . . . . . . . . . . . . . . . . . . . . . 129

5.9 The Storage Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . 129

5.9.1 Formatting A Memory Card . . . . . . . . . . . . . . . . . . . . 129

5.9.2 Creating Partitions . . . . . . . . . . . . . . . . . . . . . . . . . 130

5.9.3 Partition Management . . . . . . . . . . . . . . . . . . . . . . . . 132

5.10 IPv6 Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134

5.11 Scanner Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135

5.11.1 Bar Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136

5.11.1.1 Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . 136

5.11.2 Decoded (Internal) Scanners . . . . . . . . . . . . . . . . . . . . 137

5.11.2.1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . 137

5.11.2.2 Decoded (Internal) Advanced Options . . . . . . . . . . 138

5.11.2.3 Decoded (Internal) 2D Scanning Options . . . . . . . . 139

5.11.2.4 Decoded (Internal) 2D Scanning Options . . . . . . . . 140

5.11.2.5 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . 141

5.11.2.6 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . 144

5.11.2.7 EAN 13 . . . . . . . . . . . . . . . . . . . . . . . . . . 144

5.11.2.8 EAN 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 145

5.11.2.9 UPC A. . . . . . . . . . . . . . . . . . . . . . . . . . . 145

5.11.2.10 UPC E . . . . . . . . . . . . . . . . . . . . . . . . . . 146

5.11.2.11 UPC/EAN Shared Settings . . . . . . . . . . . . . . . 147

5.11.2.12 Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . 148

5.11.2.13 Codabar . . . . . . . . . . . . . . . . . . . . . . . . . 149

5.11.2.14 MSI Plessey . . . . . . . . . . . . . . . . . . . . . . . 149

5.11.2.15 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . 150

5.11.2.16 Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . 151

5.11.2.17 RSS Code . . . . . . . . . . . . . . . . . . . . . . . . 152

5.11.2.18 Composite . . . . . . . . . . . . . . . . . . . . . . . . 152

5.11.2.19 PDF-417 . . . . . . . . . . . . . . . . . . . . . . . . . 153

5.11.2.20 Micro PDF-417 . . . . . . . . . . . . . . . . . . . . . 153

76 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

5.11.3 Decoded (HHP) . . . . . . . . . . . . . . . . . . . . . . . . . . .154

5.11.3.1 Decoded (HHP) Scanner Options . . . . . . . . . . . . .154

5.11.3.2 Decoded (HHP) Advanced Options . . . . . . . . . . . .154

5.11.3.3 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . .155

5.11.3.4 Trioptic Code . . . . . . . . . . . . . . . . . . . . . . . .156

5.11.3.5 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . .156

5.11.3.6 EAN 13 Settings . . . . . . . . . . . . . . . . . . . . . .157

5.11.3.7 EAN 8 . . . . . . . . . . . . . . . . . . . . . . . . . . .158

5.11.3.8 UPC A Settings . . . . . . . . . . . . . . . . . . . . . . .158

5.11.3.9 UPC E Settings . . . . . . . . . . . . . . . . . . . . . . .159

5.11.3.10 UPC/EAN Shared Settings . . . . . . . . . . . . . . . .160

5.11.3.11 Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . .160

5.11.3.12 Codabar . . . . . . . . . . . . . . . . . . . . . . . . . .161

5.11.3.13 MSI Plessey . . . . . . . . . . . . . . . . . . . . . . . .162

5.11.3.14 Code 11 . . . . . . . . . . . . . . . . . . . . . . . . . .163

5.11.3.15 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . .163

5.11.3.16 Matrix 2 of 5 . . . . . . . . . . . . . . . . . . . . . . .164

5.11.3.17 IATA 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . .164

5.11.3.18 Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . .165

5.11.3.19 Telepen . . . . . . . . . . . . . . . . . . . . . . . . . .165

5.11.3.20 RSS Code (Reduced Space Symbology) . . . . . . . . .166

5.11.3.21 PosiCode (Reduced Space Symbology). . . . . . . . . .167

5.11.3.22 Composite . . . . . . . . . . . . . . . . . . . . . . . . .167

5.11.3.23 TLC-39 . . . . . . . . . . . . . . . . . . . . . . . . . .168

5.11.3.24 PDF-417 . . . . . . . . . . . . . . . . . . . . . . . . . .168

5.11.3.25 Micro PDF-417 . . . . . . . . . . . . . . . . . . . . . .169

5.11.3.26 Code 16K . . . . . . . . . . . . . . . . . . . . . . . . .169

5.11.3.27 Code 49 . . . . . . . . . . . . . . . . . . . . . . . . . .170

5.11.3.28 Codablock . . . . . . . . . . . . . . . . . . . . . . . . .170

5.11.3.29 2D Data Matrix . . . . . . . . . . . . . . . . . . . . . .170

5.11.3.30 2D QR Code. . . . . . . . . . . . . . . . . . . . . . . .171

5.11.3.31 2D Maxicode . . . . . . . . . . . . . . . . . . . . . . .171

5.11.3.32 2D Aztec . . . . . . . . . . . . . . . . . . . . . . . . .172

5.11.3.33 Postal: PlaNET . . . . . . . . . . . . . . . . . . . . . .172

5.11.3.34 Postal: PostNET . . . . . . . . . . . . . . . . . . . . . .172

5.11.3.35 Postal: Australian . . . . . . . . . . . . . . . . . . . . .173

5.11.3.36 Postal: Canadian. . . . . . . . . . . . . . . . . . . . . .173

5.11.3.37 Postal: China . . . . . . . . . . . . . . . . . . . . . . .173

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 77

Chapter 5: Configuration

5.11.3.38 Postal: Japanese . . . . . . . . . . . . . . . . . . . . . 173

5.11.3.39 Postal: Kix . . . . . . . . . . . . . . . . . . . . . . . . 174

5.11.3.40 Postal: Korean . . . . . . . . . . . . . . . . . . . . . . 174

5.11.3.41 Postal: Royal. . . . . . . . . . . . . . . . . . . . . . . 174

5.11.4 Decoded (Intermec ISCP) . . . . . . . . . . . . . . . . . . . . . 175

5.11.4.1 Decoded (Intermec ISCP) Options . . . . . . . . . . . . 175

5.11.4.2 Decoded (Intermec ISCP) Advanced Options . . . . . . 175

5.11.4.3 Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . 176

5.11.4.4 Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . 178

5.11.4.5 EAN 13 Settings . . . . . . . . . . . . . . . . . . . . . 179

5.11.4.6 EAN 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 180

5.11.4.7 UPC A Settings . . . . . . . . . . . . . . . . . . . . . . 180

5.11.4.8 UPC E Settings . . . . . . . . . . . . . . . . . . . . . . 181

5.11.4.9 UPC/EAN Shared Settings . . . . . . . . . . . . . . . . 181

5.11.4.10 Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . 182

5.11.4.11 Codabar . . . . . . . . . . . . . . . . . . . . . . . . . 183

5.11.4.12 MSI Plessey . . . . . . . . . . . . . . . . . . . . . . . 184

5.11.4.13 Code 11 . . . . . . . . . . . . . . . . . . . . . . . . . 185

5.11.4.14 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . 185

5.11.4.15 Matrix 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . 186

5.11.4.16 Discrete 2 of 5 . . . . . . . . . . . . . . . . . . . . . . 187

5.11.4.17 Telepen. . . . . . . . . . . . . . . . . . . . . . . . . . 188

5.11.4.18 RSS Code (Reduced Space Symbology) . . . . . . . . 188

5.11.4.19 PDF-417 . . . . . . . . . . . . . . . . . . . . . . . . . 189

5.11.4.20 Micro PDF-417 . . . . . . . . . . . . . . . . . . . . . 189

5.11.4.21 Codablock . . . . . . . . . . . . . . . . . . . . . . . . 190

5.11.5 Imager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190

5.11.5.1 Imager Options . . . . . . . . . . . . . . . . . . . . . . 190

5.11.5.2 Imager Advanced Options . . . . . . . . . . . . . . . . 192

5.11.5.3 Code 39 Settings . . . . . . . . . . . . . . . . . . . . . 194

5.11.5.4 Code 128 Settings . . . . . . . . . . . . . . . . . . . . . 194

5.11.5.5 EAN 13 . . . . . . . . . . . . . . . . . . . . . . . . . . 195

5.11.5.6 EAN 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . 195

5.11.5.7 UPC A. . . . . . . . . . . . . . . . . . . . . . . . . . . 196

5.11.5.8 UPC E . . . . . . . . . . . . . . . . . . . . . . . . . . . 196

5.11.5.9 Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . 196

5.11.5.10 Codabar . . . . . . . . . . . . . . . . . . . . . . . . . 196

5.11.5.11 Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . 197

78 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

5.11.5.12 RSS Code (Reduced Space Symbology) . . . . . . . . .197

5.11.5.13 Composite . . . . . . . . . . . . . . . . . . . . . . . . .197

5.11.5.14 PDF-417 . . . . . . . . . . . . . . . . . . . . . . . . . .197

5.11.5.15 Micro PDF-417 . . . . . . . . . . . . . . . . . . . . . .198

5.11.5.16 2D Data Matrix . . . . . . . . . . . . . . . . . . . . . .198

5.11.5.17 2D QR Code. . . . . . . . . . . . . . . . . . . . . . . .198

5.11.5.18 2D Maxicode . . . . . . . . . . . . . . . . . . . . . . .198

5.11.5.19 2D Aztec . . . . . . . . . . . . . . . . . . . . . . . . .198

5.11.5.20 Postal: PlaNET . . . . . . . . . . . . . . . . . . . . . .199

5.11.5.21 Postal: PostNET . . . . . . . . . . . . . . . . . . . . . .199

5.11.5.22 Postal: Australian . . . . . . . . . . . . . . . . . . . . .199

5.11.5.23 Postal: Japanese . . . . . . . . . . . . . . . . . . . . . .199

5.11.5.24 Postal: Korean . . . . . . . . . . . . . . . . . . . . . . .200

5.11.5.25 Postal: Royal . . . . . . . . . . . . . . . . . . . . . . .200

5.11.6 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200

5.11.6.1 Double Click Parameters . . . . . . . . . . . . . . . . . .201

5.11.6.2 Display Parameters . . . . . . . . . . . . . . . . . . . . .201

5.11.7 Translations Tab . . . . . . . . . . . . . . . . . . . . . . . . . . .203

5.11.7.1 Case Rules . . . . . . . . . . . . . . . . . . . . . . . . .205

5.12 SNMP (Simple Network Management Protocol) Setup . . . . . . . . . .205

5.12.1 Contact Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206

5.12.2 Communities Tab . . . . . . . . . . . . . . . . . . . . . . . . . .207

5.12.2.1 Adding A Community . . . . . . . . . . . . . . . . . . .207

5.12.2.2 Modifying A Community Setting . . . . . . . . . . . . .208

5.12.2.3 Removing An Existing Community . . . . . . . . . . . .208

5.12.3 Trap Destination Tab . . . . . . . . . . . . . . . . . . . . . . . .209

5.12.3.1 Enabling Authentication TRAPS. . . . . . . . . . . . . .209

5.12.3.2 Adding A Destination . . . . . . . . . . . . . . . . . . .209

5.12.3.3 Changing A Destination . . . . . . . . . . . . . . . . . .209

5.12.3.4 Removing A Trap Destination . . . . . . . . . . . . . . .210

5.12.4 Permitted Hosts Tab . . . . . . . . . . . . . . . . . . . . . . . . .210

5.12.4.1 Adding A Host . . . . . . . . . . . . . . . . . . . . . . .211

5.12.4.2 Changing A Host . . . . . . . . . . . . . . . . . . . . . .211

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 79

Chapter 5: Configuration

Remote Connect

5.1 Remote Connect

Remote Connect is a WORKABOUT PRO G2 application used to connect to a

Windows Terminal Server so that you can run a “session” on the Server machine, using the WORKABOUT PRO G2 (Windows Embedded CE 5.0 device).

Refer to the following website for step-by-step information about setting up this connection:

http://www.microsoft.com/WindowsXP/pro/using/howto/gomobile/remotedesktop/default.asp,

or contact Psion Teklogix support services. (Refer to WORKABOUT PRO

Hand-Held Computer Regulatory & Warranty Guide , PN 8000126 , or locate the office closest to you at www.psionteklogix.com

).

5.2 The TekTerm Application

TekTerm is a powerful emulation application ideally suited for real time data transaction applications associated with mainframes and servers. The

WORKABOUT PRO G2 includes unique features that support TekTerm—a Psion

Teklogix application that has the ability to maintain multiple simultaneous sessions with a variety of host computers. For detailed information, please refer to the

TekTerm Software User Manual, PN 8000073.

5.3 Pocket PC Compatibility

The WORKABOUT PRO G2 supports the AYGShell API set that allows Pocket

PC-compatible applications to run on the hand-held. Windows Embedded CE 5.0 includes application programming interface (API) compatibility support for the

Microsoft Windows Powered Pocket PC 2002 shell in units running Windows

Embedded CE 5.0.

The website listed below describes the APIs exposed through AYGShell and the application compatibility between Windows Powered Pocket PC 2002-based applications and Windows Embedded CE 5.0-based devices:

http://msdn.microsoft.com/library/default.asp?url=/library/en-us/dncenet/html/WINCENET_CEPCC_App.asp

5.4 The Control Panel

The Windows Embedded CE 5.0 Control Panel provides a group of icons through which you can set a variety of system-wide properties, such as mouse sensitivity, network configuration and the desktop color scheme.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 81

Chapter 5: Configuration

The Control Panel

Note: If you are uncertain how to move around a dialog box and make selections, review “Using A Dialog Box” on page 72.

When the WORKABOUT PRO G2 boots up, the startup desktop (shell) is displayed, and any applications stored in the Startup folder start up immediately.

To access the Control Panel :

• Tap on Start>Settings>Control Panel .

If you’re using the keyboard:

• Press [FN/BLUE] [.] to display the

Start Menu

.

• Highlight Settings in Start Menu , and press the [RIGHT] arrow key to highlight the Control Panel .

• Press the [ENTER] key.

The Control Panel folder contains icons used in the setup of your WORKABOUT

PRO G2.

Figure 5.1 Control Panel

82 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Control Panel Icons

5.5 Control Panel Icons

The Control Panel provides a group of icons that allow you to customize and adjust settings on your WORKABOUT PRO G2.

App Launch Keys

By mapping keys to applications using this program, you can then launch those applications from a single key-press.

Bluetooth Devices

Provides options for Bluetooth radio setup. It also provides the capability to use a Bluetooth-enabled cellular phone as a data modem to exchange information with other Bluetooth devices and provide network access.

Certificates

A public key is transmitted as part of a certificate. The certificate assigned through this icon is used to ensure that the submitted public key is, in fact, the public key that belongs to the submitter. The client checks that the certificate has been digitally signed by a certification authority that the client explicitly trusts. “Certificate Assignment” on page 110 directs you to the appropriate setup information.

Date/Time

Allows you to set the current Month, Date, Time and Time Zone on your unit.

Dialing

Specifies dialing settings, including area code, country code, dial type and the code to disable call waiting. You can store multiple patterns— for example, ‘Work’, ‘Home’, and so on using this dialog box.

Display

Changes the appearance (window colour scheme) on the unit desktop.

Input Panel

Provides the framework for a Soft Input Panel (SIP) should you need to design your own SIP, or change some soft keyboard options.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 83

Chapter 5: Configuration

Control Panel Icons

Internet Options

Provides options to configure your Internet browser. You can determine items such as the default and search page that the browser applies when connecting to the Internet, the cache size, the Internet connection options, and the security level that is applied when browsing.

IPv6 Support

Refers to a new Internet Protocol specification (version 6) that has been published to use 128-bit IP addresses (replacing version 4).

Keyboard

Toggles character repeat on and off and specifies delay and rate for repeated characters. It also allows you to adjust the keyboard backlight threshold and intensity.

Manage Triggers

Allows multiple-scanner trigger management, including the ability to configure each of the trigger buttons. You can configure the trigger ID for each trigger button for both single- and double-click, and the double-click time.

Network And Dial-up Connections

Displays a network window from which the WORKABOUT PRO G2

802.11g radio can be configured and an existing configuration can be executed. Refer to “Configuring Your Radio” on page 13 for details.

Owner

Provides fields in which you can specify owner information. A Notes tab allows additional information to be entered and displayed when the unit is powered up. Network ID tab information is used to access network resources.

(This information should be provided by your System Administrator.)

Password

Allows you to assign a password to restrict access to elements of the unit.

Once assigned, password access cannot be circumvented so it is important that you write down your password and keep it in a safe place. Refer to

“Security Settings” on page 64 for details.

84 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Control Panel Icons

PC Connection

Enables direct connections to a desktop computer. Selecting the Change

Connection button allows you to change the type of direct connect to your PC.

Power

Displays battery pack power status. (Alternately, battery status can be accessed through the taskbar.) Additional tabs allow you to determine suspend states, specify a suspend threshold and, when seated in either the

Combo Dock or Quad Dock, determine whether or not a battery that requires it can be recalibrated. This dialog box also allows you to activate card slots. (Refer to “Devices” on page 104 for details.)

RDC Licenses

The Terminal Services license server stores all license tokens that have been installed for a group of terminal servers and tracks licenses issued. The

Remote Desktop Licenses (RDC) application displays license ‘tokens’ for devices that connect to a Terminal Server.

Region & Language

Allows you to specify the local language that is to be displayed on the hand-held screen along with the format of numbers, currency, time and date for your region.

Remove Programs

Lists the programs that can be removed from your unit. To remove a program, select it and then click on the Remove button.

SNMP

SNMP (Simple Network Management Protocol) is the protocol used to monitor and manage devices attached to a TCP/IP network.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 85

Chapter 5: Configuration

Control Panel Icons

Storage Manager

Allows the user to view information about the storage devices that are present, such as SD-MMC flash cards. For details, see page 129.

S

tylus

Adjusts how Windows Embedded CE 5.0 recognizes your double-tap (as slow or rapid successive taps). In the Calibration tab, you can recalibrate your touchscreen by tapping on the Recalibrate button and following the directions on the screen.

System

Displays system and memory properties. In the Memory tab, you can allocate memory between storage memory and program memory.

Teklogix Scanners

Provides scanner parameters and the bar code symbologies that the WORK-

ABOUT PRO G2 scanner will successfully read.

Total Recall

Provides access to a backup and restore utility to maintain applications and settings over cold reboots.

TweakIT Settings

Allows you to change Advanced System Settings (interface, network, and servers), User System Settings (display font size), and provides the

Registry Editor.

Volume & Sounds

Allows you to adjust the volume of the sound emitted to indicate events like warnings, key clicks and screen taps.

Wireless WAN

Provides access to technology like GSM/GPRS, which allows wide area networking capability such as internet browsing via GSM/GPRS. For detailed information, see Appendix B: “Wireless WAN”.

86 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

5.6 Basic Setup

5.6.1 Display Properties

• In the Control Panel , choose the Display icon.

Chapter 5: Configuration

Basic Setup

Figure 5.2 Choosing The Display Icon

5.6.1.1

Display Backlight

The backlight is activated for a configurable amount of time when the

WORKABOUT PRO G2 is in use (key press, scanner trigger or data received from the host). The Display Properties dialog box in the Control Panel allows you to specify the intensity of the backlight along with how long the display will maintain the specified intensity.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 87

Chapter 5: Configuration

Display Properties

Note: Keep in mind that this option may be restricted to supervisory use only.

• In the Display Properties dialog box, open the Backlight tab.

Notes: Backlight changes take effect immediately. You do not need to reset the unit.

To maximize battery run time, keep the display backlight brightness and active durations as low as possible.

Intensity

This parameter is used to adjust the light intensity of the WORKABOUT PRO G2 backlight. Sliding the bar to the left lowers the light intensity, and sliding it to the right raises the intensity.

Bright For

The value chosen from this drop-down menu determines the duration of time that the backlight stays on at the configured intensity after the last user action (keypress, scan trigger).

88 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Display Properties

Dim For

The value chosen from this drop-down menu determines the duration of time that the backlight stays on at half the configured intensity (dimmed backlight) after expiration of the Bright For delay and as long as no user action takes place (such as a keypress or scan trigger). At the expiration of the Dim For duration, the display backlight shuts off.

External Power Checkbox

When you select the checkbox next to When using external power keep the backlight always ON

,

the backlight remains ON at the configured intensity when the WORKABOUT PRO G2 is operating with external power (not battery power).

If the WORKABOUT PRO G2 is drawing power from its battery, this option is ignored and the other parameters defined in Display Properties dialog box are used.

5.6.1.2

Display Appearance

• In the Display Properties dialog box, open the Appearance tab.

This dialog box allows you to customize the display colour scheme.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 89

Chapter 5: Configuration

Keyboard Properties

5.6.2 Keyboard Properties

This icon displays the Keyboard Properties dialog box in which you can adjust the repeat rate of the keys, the intensity of the keyboard backlight and the behaviour of the [BLUE] and [ORANGE] modifier keys. This dialog box also allows you to define macro keys and Unicode characters.

• In the Control Panel , choose the Keyboard icon.

Figure 5.3 Choosing The Keyboard Icon

5.6.2.1

Key Repeat

Note: These settings apply when a key is held down continuously.

• In the Keyboard Properties dialog box, open the Repeat tab.

90 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Keyboard Properties

Repeat Delay

The value assigned for this parameter determines the delay in milliseconds between repeat characters. Sliding the Repeat Delay bar to the left increases the delay between key repeats, and sliding the bar to the right shortens the repeat delay time.

Repeat Rate

The value assigned for the Repeat Rate parameter determines how quickly the key you press repeats and is measured in characters per second (cps). Sliding the bar to the left slows the repeat rate, and sliding the bar to the right increases the repeat rate.

Note: Use the field at the bottom of this dialog box to test the repeat delay and rate settings you’ve chosen.

5.6.2.2

Keyboard Backlight

• In the Keyboard Properties dialog box, open the Backlight tab.

This parameter is used to adjust the light intensity of the WORKABOUT PRO G2 keyboard backlight. Sliding the bar to the left darkens the keyboard backlight intensity, and sliding it to the right lightens the intensity.

ON For

The value chosen from this dropdown menu determines the duration of time that the keyboard backlight stays on when a unit is not in use.

Note: Tapping in the checkbox next to ‘When using external power, keep the backlight always ON’ forces the keypad backlight to remain on when the unit is operating with external power.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 91

Chapter 5: Configuration

Keyboard Properties

5.6.2.3

Keyboard One Shot Modes

• In the Keyboard Properties dialog box, open the One Shots tab.

The options in this tab allow you to determine how modifier keys on your

WORKABOUT PRO G2 behave. For each modifier key

[ALT], [SHIFT],

[CTRL], [ORANGE] and [BLUE]

you have the following options in the drop-down menu: Lock, OneShot, and OneShot/Lock.

Note: Keep in mind that checking the taskbar lets you know whether or not these keys are locked on. For example, if the [FN/ORANGE] key is locked

‘on’, the taskbar at the bottom of the screen displays it in uppercase characters,

ORANGE KEY.

If this key is displayed in lowercase characters in the taskbar, you’ll know that the

orange key

is not locked. It will become inactive following a key press.

Important: Once you’ve assigned a One Shot mode to a modifier key, you need to tap on the OK button at the top of the tab to activate your selection.

Lock

If you choose Lock from the drop-down menu, pressing a modifier key once locks it

‘on’ until you press the modifier key a second time to unlock or turn it off.

92 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Keyboard Properties

OneShot

If you choose OneShot , the modifier key remains active only until the next key is pressed.

OneShot/Lock

OneShot/Lock allows you to combine these functions. When you choose this option and you press the modifier key once , it remains active only until the next key is pressed.

If you press the modifier key twice , it is locked ‘on’, remaining active until the modifier key is pressed a third time to turn it ‘off’.

5.6.2.4

Keyboard Macro Keys

• In the Keyboard Properties dialog box, open the Macros tab.

A macro has 200 programmable characters (or “positions”). The macro keys can be programmed to replace frequently used keystrokes, along with the function of executable keys including [ENTER], [BKSP] and [DEL] ([FN/BLUE]-[BKSP]), function keys and arrow keys.

Recording And Saving A Macro

You can program up to 12 macro keys on a 58-key WORKABOUT PRO G2. On a

36-key WORKABOUT PRO G2, you can program a maximum of 6 macro keys.

• In the Macro menu highlight a macro key number, for example macro

1,

to assign a macro to macro key [M1]

.

Choose the Record button.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 93

Chapter 5: Configuration

Keyboard Properties

A message screen is displayed instructing you to Enter Key Strokes to Record

• Type the macro sequence you want to assign to the Macro key. You can type text and numbers, and you can program the function of special keys into a macro.

• When you’ve finished recording your macro sequence, press the key sequence: [CTRL] [ALT] [ENTER], or choose the Stop Recording button.

A new screen called ‘Verify Macro’ displays the macro sequence you created.

The Save button is highlighted.

• Press [ENTER] to save your macro, or highlight CANCEL and press

[ENTER] to discard it.

Executing A Macro

To execute a macro:

• Press the macro key to which you’ve assigned the macro. For example, if you created a macro for macro key 1 , press [M1] to execute the macro.

Deleting A Macro

To delete a macro:

• In the Macros tab, highlight the macro number you want to delete.

• Choose the Delete button.

94 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Keyboard Properties

5.6.2.5

Unicode Mapping

• In the Keyboard Properties dialog box, open the Unicode Mapping tab.

The Unicode Mapping tab is used to map combinations of virtual key values and

[CTRL] and [SHIFT] states to Unicode™ values. This tab shows the configured

Unicode character along with the Unicode value. For example, the sample screen above shows “a (U+0061)” indicating that the character “a” is represented by the

Unicode value “0061”, and so on. Keep in mind that Unicode configurations are represented as hexadecimal rather than decimal values.

All user-defined Unicode mappings are listed in the Unicode Mapping tab in order of virtual key value, and then by order of the shift state. If a Unicode mapping is not listed, the Unicode mapping is mapped to the default Unicode value.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 95

Chapter 5: Configuration

Keyboard Properties

Adding And Changing Unicode Values

Important: Changes to Unicode mappings are not saved until you exit the

Keyboard Properties dialog box.

• Choose the Add/Change button.

Figure 5.4 Adding And Change Unicode Values

• Highlight a value in the Unicode mapping list. In the sample screen above, a value will be assigned to virtual key 0 (VK 0).

• Position the cursor in the Unicode Mapping field, and type a Unicode value for the highlighted key.

Note: To add a shifted state, [SHIFT] and/or [CTRL], press [TAB] to position the cursor in the checkbox next to ‘SHIFT Pressed’ and/or ‘CTRL

Pressed’. Press [SPACE] to select the shift state you want to assign.

Removing Unicode Values

• In the Unicode Mapping tab, highlight the item you want to delete, and choose the Remove button.

96 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Keyboard Properties

5.6.2.6

Scancode Remapping

A scancode is a number that is associated with a physical key on a keyboard. Every key has a unique scancode that is mapped to a virtual key, a function or a macro.

Scancode Remapping allows you to change the functionality of any key on the keyboard. A key can be remapped to send a virtual key (e.g. VK_F represents the

‘F’ key; VK_RETURN represents the [ENTER/ON] key, etc.), perform a function

(e.g. turn the scanner on, change volume/contrast, etc.) or run a macro.

There are three different tables of scancode mappings: the Normal table, the Blue table and the Orange table. The Normal table defines unmodified key presses; the

Blue table defines key presses that occur when the [FN/BLUE] modifier is on; the

Orange table defines key presses that occur when the [FN/ORANGE] modifier is on. The default mappings of these scancodes can be overwritten for each of these three tables using the Scancode Remapping tab accessed from the Keyboard

Properties dialog box.

The first column in the Scancode Remapping tab displays the scancodes in hexadecimal. If the scancode is remapped to a virtual key, that virtual key is displayed in the next column labelled ‘V-Key’. A virtual key that is ‘Shifted’ or

‘Unshifted’ is displayed in the third column labelled ‘Function’.

If the scancode is remapped to a function or a macro, the first and second columns remain blank while the third column contains the function name or macro key number (e.g., Macro 2).

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 97

Chapter 5: Configuration

Keyboard Properties

Adding A Remap

To add a new remapping:

• Choose the Add button at the bottom of the dialog box.

The Remap Scancode dialog box is displayed.

• Type the scan code in hexadecimal in the field labelled Scancode

Note: The Label field displays the default function of the scancode you are remapping.

Virtual Key, Function And Macro

The radio buttons at the bottom of the dialog box allow you to define to what the scan code will be remapped: Virtual Key, Function or Macro.

When Virtual Key is selected, you can choose to force [SHIFT] to be on or off when the virtual key is sent. If No Force is selected, the shift state is dependent on whether the shift state is on or off at the time the virtual key is sent.

When Function is selected, a list of valid functions appears in the dialog box.

When Macro is selected, the macro keys available on your unit are listed in the dialog box.

• Choose Virtual Key , Function or Macro

.

• Choose a function from the Function list in the dialog box, and tap on OK .

98 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Volume And Sound Properties

Editing A Scancode Remap

To edit a scancode:

• In the Scancode Remapping tab, tap the stylus on the remap you want to edit.

• Tap on the Edit button, and make the appropriate changes.

• Tap on OK to save your changes.

Removing A Remap

To delete a remap:

• In the

Scancode Remapping

tab, highlight the scancode you want to delete, and tap on the Remove button.

• Tap on OK .

5.6.3 Volume And Sound Properties

• In the Control Panel , choose the Volume & Sounds icon.

Figure 5.5 Choosing The Volume Icon

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 99

Chapter 5: Configuration

Power Management Properties

5.6.3.1

Volume Adjustments

• Slide the volume button to the left to lower the beeper volume or to the right to increase the beeper volume.

• Under the heading Enable sounds for , enable the conditions under which you want the WORKABOUT PRO G2 to emit a beep.

5.6.4 Power Management Properties

This icon displays a Power Properties dialog box that indicates the unit’s battery capacity and allows you to manage battery use.

• In the Control Panel , choose the Power icon.

100 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Power Management Properties

5.6.4.1

Battery Capacity

• In the Power Properties dialog box, open the Battery tab to view battery details.

5.6.4.2

Power Saving Suspend

• In the Power Properties dialog box, open the Suspend tab.

Power Source

This drop-down menu allows you to specify whether the unit is using AC Power or

Battery Power .

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 101

Chapter 5: Configuration

Power Management Properties

Suspend Timeout

Important: Psion Teklogix recommends setting the Suspend value to 10 minutes. To further reduce power consumption, carefully consider the duration of time that the display backlight is ‘on’ (see “Display

Backlight” on page 87).

When the WORKABOUT PRO G2 is idle—not receiving any user input (a key touch, a scan, and so on) or system activity (serial data, an activity initiated by an application, and so on)—the hand-held uses the value assigned in the Suspend

Timeout field to determine when the unit will go to sleep (appear to be off).

When the time in the Suspend Timeout field elapses without any activity, the unit enters suspend state. In suspend state, the WORKABOUT PRO G2 CPU enters a sleep state, and the radio is shut off. The state of the device (RAM contents) is preserved. Pressing [ENTER] wakes the system from suspend state. When the

WORKABOUT PRO G2 is in suspend state, the network connection will not be broken immediately. If the connection is dropped, you must re-establish the network connection.

5.6.4.3

Suspend Threshold

The Suspend Threshold adjustment tells the system when to shut down when the battery drains. If you choose Maximum Operating Time , the unit will run until the battery is completely empty; the RAM is only backed up for a short period of time.

If you choose Maximum Backup Time , the hand-held shuts off with more energy left in the battery so RAM can be backed up for a longer period of time.

102 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Power Management Properties

Important: Selecting Maximum backup time will reserve approximately 20% of the battery capacity for memory backup. Once the battery is drained, the system RAM memory is lost and the unit must cold boot.

In most real-time transaction environments this is not a problem

(it only takes a few seconds to cold boot). Batch transaction environments, where data is not saved to a non-volatile memory (such as an SD FLASH card), may need to pay particular attention to this parameter. Psion Teklogix does not recommend the storage of any valuable data in system RAM.

The WORKABOUT PRO G2 normal Windows Embedded CE 5.0 environment does not store any critical data in RAM (such as the registry or file system).

If the user's application does not save data to RAM, Psion Teklogix recommends keeping the Suspend Threshold setting as low as possible to maximize battery run time.

5.6.4.4

Advanced

Allow Suspend With:

This tab allows you to specify whether or not your unit will enter Suspend state while it is operating with an active PPP connection, network interface or active

TCP/IP connection.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 103

Chapter 5: Configuration

Stylus Properties

Low Power Warnings

The sliding scale at the bottom of this tab allows you to specify the remaining battery capacity at which a warning message is displayed on the WORKABOUT

PRO G2 screen, from 0% to 20%.

5.6.4.5

Devices

This tab controls power to individual CF and SDIO slots, and built-in devices.

Enable or disable the checkboxes as needed, then tap on OK to save your changes.

5.6.5 Stylus Properties

Note: Touchscreen calibration may not be enabled on your unit. If your screen appears to require recalibration, contact your supervisor.

• In the Control Panel , choose the Stylus icon.

104 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Stylus Properties

5.6.5.1

Double-Tap

• In the Double-Tap tab, follow the directions to tailor the sensitivity of the stylus when you tap on the touchscreen.

5.6.5.2

Calibration

Touchscreens rarely require recalibration. However, if your touchscreen has never been calibrated or if you find that the stylus pointer is not accurate when you tap on an item, follow the directions below.

• Choose the Calibration tab, and then tap on the Recalibrate button.

• Follow the directions in the

Calibration

tab to recalibrate the screen.

5.6.5.3

Touch

This tab allows you to disable the touchscreen.

• Choose the Touch tab. Select the checkbox next to

Disable the touch panel

.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 105

Chapter 5: Configuration

Manage Triggers

5.6.6 Manage Triggers

This option allows you to configure how bar code scanners and other devices such as RFID readers are triggered. You can configure the trigger ID for each trigger button for both single- and double-click, and the double-click time.

• In the Control Panel , choose the Manage Triggers icon.

Figure 5.6 Manage Triggers Icon

• In the Manage Triggers screen you’ll see a list of trigger mappings.

106 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Manage Triggers

5.6.6.1

Trigger Mappings

A trigger mapping is an association between a particular key on the keyboard and a driver or application, the “owner(s)” of the trigger source. When the specified key is pressed, the owner (for example, a decoded scanner) is sent a message.

Important: It is not possible to have two or more identical mappings—for example [F1] cannot be mapped to the Non-Decoded Scanner twice—even if the trigger type is different.

A keyboard key that is used as a trigger source will no longer generate key data, or perform its normal function. For example, if the space button is used as a trigger source, it will not be able to send space characters to applications.

Double-Click

When a key is pressed and released, then pressed again within the configured time

(between 0 to 1000 milliseconds), a double-click occurs. See also “Trigger-Press

Type” on page 109.

Show All

By default, the trigger mapping list only shows active mappings. Mappings for drivers or applications that are not currently active are not normally displayed. By checking this checkbox, all mappings, both active and inactive, are displayed.

Add

Tapping this button brings up the Add mapping dialog (see page 108), so that you can add new trigger mappings.

Edit

Tapping this button brings up the Edit mapping dialog (see page 108), so that you can edit existing trigger mappings.

Remove

Tapping this button removes an existing mapping.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 107

Chapter 5: Configuration

Manage Triggers

OK

The OK button in the top right of the Manage Triggers screen saves all changes made. If the cancel button X is tapped instead, or the [ESC] key is pressed, all changes made will be discarded.

5.6.6.2

Add And Edit Trigger Mapping

These dialogs allow the user to add and edit trigger mappings.

Trigger Key

This dropdown list allows you to specify the source of the trigger events, such as the

Grip Trigger, Left Scan, etc., for the trigger module selected.

Notes: It is possible to map the same source to different modules (trigger consumers)—for example, to both the Imager and Non-Decoded Scanner. If so, both devices/operations will occur simultaneously. This is not recommended in most cases, especially with devices such as Imagers or RFID

Readers.

It is also possible to map different sources to the same module (trigger consumer)—for example, two different trigger keys can be mapped to the

RFID File System.

108 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Manage Triggers

Add Key

Only existing trigger sources are shown in the Source combo-box. To add a new source to this list, tap on the Add Key button. A dialog will pop up and allow you to select the keyboard key to use as a trigger source.

Trigger-Press Type

You can enable either an Up/Down or Double Click response to a trigger press.

Normally, when a trigger (keyboard key, etc.) is pressed and released, a “trigger down” event is sent to the “owner”—that is, the application receiving the trigger press information—followed by a “trigger up”. If Double Click is chosen in this menu, when the trigger is pressed, released, and then pressed again, a “double-click” event will have occurred. If a mapping with the type Up/down has also been configured for the same source, it will only receive the first set of trigger events.

Module Trigger

This identifies the driver or application receiving the trigger presses.

Show All Modules

By default, inactive owners are not shown. By checking this checkbox, all owners, both active and inactive, are displayed.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 109

Chapter 5: Configuration

Certificate Assignment

5.6.7 Certificate Assignment

• In the Control Panel , choose the Certificate icon.

Figure 5.7 Certificates Icon

This option is used in conjunction with 802.1x authentication to enhance

WORKABOUT PRO G2 security.

For a detailed description about

Certificate

setup for both the server and client-side devices (WORKABOUT PRO G2s), refer to the following website:

http://www.microsoft.com/windowsserver2003/techinfo/overview/security.mspx

Note: When importing certificates, the WORKABOUT PRO G2 only recognizes

.cer files.

110 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Bluetooth Setup

5.7 Bluetooth Setup

Bluetooth is a global standard for wireless connectivity for digital devices and is intended for Personal Area Networks (PAN). The technology is based on a short-range radio link that operates in the ISM band at 2.4 GHz. When two

Bluetooth-equipped devices come within a 5 meter range of each other, they can establish a connection. Because Bluetooth utilizes a radio-based link, it does not require a line-of-sight connection in order to communicate.

Note: The Bluetooth radio uses an internal antenna.

• In the Control Panel , choose the Bluetooth Device Properties icon to display the

Bluetooth Control

screen.

Figure 5.8 Bluetooth Icon

The

Bluetooth Control

dialog box is used to display the other Bluetooth devices with which you can communicate.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 111

Chapter 5: Configuration

The Devices Tab

5.7.1 The Devices Tab

If you intend to configure Bluetooth communication with specific devices (a scanner or printer for example), power on and bring the devices within 5 m (16.4 ft.) of the hand-held before proceeding with the discovery process described below.

Scan

• Click on the Scan button to list available devices.

Figure 5.9 Available Bluetooth Devices

Wait for the WORKABOUT PRO G2 to complete its scan (approximately 20 seconds). When scanning starts, the Scan button will change to Stop

if necessary, you can tap on this button to stop the process. Once scanning is complete, all discovered devices will be displayed in the list box, with Name, Address, Active status, and PIN information.

112 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

The Devices Tab

Note: During the scanning process, addresses are located first, followed by names. Only the names of devices that are within the Bluetooth radio coverage range will be retrieved.

The Active column indicates whether any service is activated for that device. When a service is activated, the device is displayed in the list even when it is not detected during the scan.

The PIN column indicates whether you have a PIN (password) set for the device.

At this point you can either query for services or set the PIN for each device. Once you highlight a device in the list box, both the

Services

and

Set PIN

buttons become available.

Services

A discovered device may display several service profiles that it can use to communicate, and you will want to activate the type you need. Supported profiles that can be activated include: DUN (Dial-Up Networking service), Printer (serial service), and LANPPP (LANAccessUsingPPP service). ASync (ActiveSync) is another available profile.

• To start the service scan, highlight a device in the

Devices

tab list, and then click on the Services button or double-click on the device entry.

Note: If the remote device is out of reach or turned off, it can take a considerable amount of time for the Services dialog box to appear—it may appear to be frozen.

Once the device’s service profiles are displayed in the Services list box:

• Highlight the service to be activated.

• Press [SPACE] or right-click to display the Activation menu.

The Activation menu contains four options: Activate, Authenticate, Outgoing, and Encrypt.

Once the service is successfully activated, the assigned port (if applicable) will appear in the Port column of the Services list box. You can choose to use BSP or

COM as the port name. BSP is the latest Microsoft Bluetooth stack standard, but older applications assume serial ports are COM. When using COM as the port name, the Bluetooth manager will try to find and use a free port between COM7 and

COM9. When using BSP as the port name, BSP2 to BSP9 are available for use. The port is available as soon as it is activated.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 113

Chapter 5: Configuration

The Devices Tab

Note: The CH column shows the RFCOMM channel of the service if the service is RFCOMM-based. This information is not generally needed except for debugging purposes.

To add a service to the Outgoing port, an active service must first be deactivated.

Then you can choose the ‘Outgoing’ option from the Activation menu (highlight a service, right-click or press the [SPACE] bar to display the Activation menu).

The Authentication and Encryption options can be changed only before activation.

To change these after activation, deactivate the service first, then change the options.

Once a service is activated, all the information regarding the service, including the

RFCOMM channel number, is saved in the registry. (Some remote devices may change their RFCOMM channel numbers when they reboot, so your saved setting may not work when the remote device is rebooted. In that case, you must deactivate the service and reactivate it to detect the current RFCOMM channel.)

Set PIN

PINs can be set for each device by pressing the Set PIN button in the Devices tab, or you can skip this step and try to connect to the device first.

Important: The remote device must have authentication enabled, otherwise the

PIN authentication will fail.

• Highlight a device, click on the Set Pin button, and type the PIN .

You will receive a message, either that the PIN has been successfully validated or that it has been rejected.

If the PIN has been validated, an asterisk (*) appears in the PIN column in the

Devices list box, indicating that this device has a PIN set. Once a PIN is entered, it is saved in the registry.

To remove the PIN:

• Choose Set PIN

,

and press [ ENTER ] .

If the WORKABOUT PRO G2 attempts to connect to a remote device that has

Authentication enabled and does not have a required PIN set, an Authentication

Request dialog box appears.

• Enter the PIN , and tap on OK to connect the devices.

114 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

The Servers Tab

5.7.2 The Servers Tab

The Bluetooth connection is initiated from your WORKABOUT PRO G2 to the remote device. Therefore the WORKABOUT PRO G2 is called the ‘client’ and the remote is called the ‘server’. The

Servers

tab displays the server profiles that can be activated in your WORKABOUT PRO G2. There is currently one server profile available: Serial.

• Tap on the checkbox to activate the server, and it will display the associated port name beside the server name.

Once you activate a server profile, it is recommended that the WORKABOUT PRO

G2 be rebooted before you try to bond from a server.

Note: You do not need to reboot if you are deactivating a server.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 115

Chapter 5: Configuration

Outgoing Tab

5.7.3 Outgoing Tab

Outgoing Port acts as a serial port that can be used to connect to a list of Bluetooth devices (one at a time), but you have the freedom to switch on-the-fly .

The

Outgoing Port

checkbox allows you to create the Outgoing port. When the port is created, the Outgoing tab lists the port name.

The Outgoing list dialog box displays a list of services marked as ‘Outgoing’. The

*

column indicates the currently selected service. You can tap on

Unselect

to reset the current selection, or you can tap on

Select

to make a selection. The

Remove

button deletes the service from the outgoing list.

The Prompt menu determines the behaviour of the pop-up Selection menu.

Choosing Everytime causes the Selection menu to be displayed each time an outgoing port is created. If you choose Once , the menu is displayed only when a partner service is not selected.

To display the Selection menu at any time:

• Press [CTRL] [ALT] [F1], and switch the partner Bluetooth device.

If a connection to a partner device already exists, the connection is dropped and another connection to the newly selected device is created instantly without disrupting the application that has opened the outgoing port.

Note: To add a service to the Outgoing port, an active service must first be deactivated. Then you can choose the ‘Outgoing’ option from the Activation menu (highlight a service, right-click or press the [SPACE] bar to display the Activation menu).

116 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Active Conn. Tab

5.7.4 Active Conn. Tab

The Active Conn . tab lists the Name , Address , and Type of the currently active connections. The table is periodically updated, but it can take a few seconds before it reflects the actual list of connections. The Type column of the table shows ‘ACL’ or ‘SCO’. The Connection list table shows the connections for scanning as well as the service connections.

Note: You can change the device-name and description of your radio by clicking on the System icon in Control Panel, which will open the System Properties dialog box. Click on the Device Name tab to access the menu and change your settings. Then click on OK.

Although the name will have changed in the Properties menu in Bluetooth

Controls, the radio only reads it on boot-up. For the changes to take effect, you must cold reset the WORKABOUT PRO G2 (for cold reset instructions, see “Resetting The Hand-Held” on page 31).

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 117

Chapter 5: Configuration

The Properties Tab

5.7.5 The Properties Tab

The

Properties

tab displays information about your WORKABOUT PRO G2, and provides some port options.

The Device Name field shows the device name of your WORKABOUT PRO G2.

This name can be changed (see the Note on the previous page for details).

Device Class shows the Class of Device (e.g. desktop, hand-held), which is always set to Handheld .

Local Bluetooth Address shows the address of your WORKABOUT PRO G2 radio.

Port Prefix is used to set the port name to either BSP or COM . When the name is set to BSP , BSP2 to BSP9 are available for activated services (including the server).

When COM is chosen, COM7 to COM9 are available.

NQuery Retry (Name Query Retry) governs the number of times the hand-held will attempt to query the names of other Bluetooth devices if the first attempt fails.

(When the WORKABOUT PRO G2 scans for other devices, it sometimes fails to scan names.)

Note: Keep in mind that setting this parameter to a higher value will lengthen the scan time.

5.7.6 The Bluetooth GPRS WAN Connection

The following steps describe how to set up an internet data connection using a GSM cellular telephone with Bluetooth. The WORKABOUT PRO G2 communicates via

Bluetooth to the cell phone, which then accesses a WAN (Wide Area Network) and transfers data using GPRS.

118 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

The Bluetooth GPRS WAN Connection

1.

To set up the internet parameters, choose the Network And Dial-up

Connections icon from the Control Panel

.

Figure 5.10 Network And Dial-up Connection Icon

2.

Choose the Make New Connection icon.

Figure 5.11 Creating A GPRS Connection

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 119

Chapter 5: Configuration

The Bluetooth GPRS WAN Connection

3.

In the Make New Connection dialog box, choose Dial-Up Connection .

Enter a name for your GPRS network connection.

4.

Choose the Next button to display the Modem dialog box.

5.

In the drop-down menu labelled Select a modem , choose the name of the modem with which you want to connect, and then choose the

Configure button to display the

Device Properties

dialog box.

120 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

The Bluetooth GPRS WAN Connection

The WORKABOUT PRO G2 communicates via Bluetooth to your Bluetooth-equipped cellular telephone and retrieves the parameters for the

Device Properties dialog box. The WORKABOUT PRO G2 then disconnects.

6.

Under the Call Options tab, turn off Cancel the call if not connected within, and press [ENTER] to save your changes.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 121

Chapter 5: Configuration

The Bluetooth GPRS WAN Connection

7.

In the Modem dialog box, choose the Next button to display the Phone

Number dialog box.

The phone number you enter is network carrier dependent. Once you’ve specified all the necessary information, choose the Finish button.

8.

In the Control Panel , choose the Dialing icon.

9.

The values in the Dialing Properties dialog box need to be edited according to your network carrier specifications.

122 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

The Bluetooth GPRS WAN Connection

Once you’ve edited this dialog box to reflect your network carrier requirements, press [ENTER] to save your changes.

10. At this point, you’ll need to return to the Control Panel, and choose the

Network and Dial-up Connections icon.

11. In the network connection window, the new network configuration, in this case GPRS Network is displayed. Tap on the new icon.

When you tap on your new connection, an onscreen message indicates the status of your connection: connected, disconnected, error messages, and so on.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 123

Chapter 5: Configuration

Total Recall

5.8 Total Recall

Total Recall

is a Psion Teklogix utility developed to back up/restore applications and settings. Keep in mind that to protect your data from erasure during a ‘clean start’, the Total Recall profile must be stored on a SD/MMC card or externally to the device on a USB memory stick or on a PC.

Note: In Windows Embedded CE 5.0, the registry and installed programs are stored in the Flash file system and are not lost on reset. However, a clean start will reset not only the registry settings to factory defaults, but will also erase any files or applications stored or installed on the built-in

Flash file system, including any Total Recall profiles. This is why any data that needs to be protected must be stored on a SD/MMC card or externally to the device on a USB memory stick or on a PC.

• In the Control Panel , choose the Total Recall icon

Figure 5.12 Total Recall Icon

124 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

5.8.1 Creating A Backup Profile

Chapter 5: Configuration

Creating A Backup Profile

In the drop-down menu, you can choose from four options: Create Backup Profile,

View Selected Profile, Restore Selected Profile and Delete Selected Profile. Keep in mind however that until a profile is created, the only available option is Create

Backup Profile

.

• Choose the Next button to begin the process.

Profile Information

This dialog box lists the possible storage destinations for the profile file.

• To begin, type a name for the profile in the field labelled Profile Name.

• Next, choose the Profile Type you want to create:

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 125

Chapter 5: Configuration

Creating A Backup Profile

For this device only

creates a backup that is manually restored by the operator.

AutoRestore for this device only

creates a profile that automatically restores itself following a clean start.

AutoRestore for this and other devices

creates a profile that automatically restores after resuming from a clean start, but it will not contain the touchscreen calibration coordinates or the Wireless radio settings.

• Finally, choose a Profile Location – The location for the profile is either

\Flash Disk or \SD-MMC Card .

• Tap on the Next button to display the next dialog box Add Files

.

Add Files

Figure 5.13 Adding Files

By default, All Files is selected so that all installed or copied files, database entries, and the Registry will be saved. You can, however, limit the backup to databases, and/or the registry only. By tapping the checkbox next to these items, you can add or remove a check mark to enable or disable the option.

126 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Creating A Backup Profile

The Select Files option allows you to select predefined file types.

• Remove the check mark next to All Files . You’ll notice the checkbox next to Select Files changes , indicating that additional options are available.

• Choose this icon next to Select Files to view your options.

Figure 5.14 By File Type

Choosing By Individual File displays a pop-up menu where you can tailor the list of files you want to back up.

Figure 5.15 Add Files

To add a file to your backup list:

• Choose Add Files . Browse to and choose the files you want to add to your list.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 127

Chapter 5: Configuration

Creating A Backup Profile

To remove a file from your backup list:

• Choose Remove Files —a dialog box is displayed listing the files that will be backed up.

• Highlight the item you want to remove from the list, and tap on the

Remove button.

Choosing By File Type allows you to select the file types that you want backed up.

Figure 5.16 Adding Files By File Type

View Selections

Depending on what you have selected for inclusion in your profile, you can view a list of the selected files, databases and/or registry.

• Choose the Next button to perform the operation.

128 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Restoring A Profile

Perform The Operation

Figure 5.17 Performing The Backup

• Choose the Backup button to start the process, and create a profile.

5.8.2 Restoring A Profile

To manually restore a profile:

• Choose Restore Selected Profile from the drop-down menu, and choose the Profile Name displayed in the drop-down menu.

Note: You can also manually restore an auto restore profile located in flash or a storage device.

5.9 The Storage Manager

The Storage Manager allows the user to view information about the storage devices that are present in the WORKABOUT PRO G2, such as SD-MMC flash cards and

Compact Flash cards.

5.9.1 Formatting A Memory Card

Formatting a memory card bulk-erases it. Once a card is erased, partitions may be created in it, similarly to those on a hard drive. Memory-card devices are normally

‘mounted’ (made available to the system) automatically when they are inserted.

They must be dismounted before they can be formatted.

To format an entire memory card:

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 129

Chapter 5: Configuration

Creating Partitions

1.

Select Start > Settings > Control Panel .

2.

In Control Panel , double-click on the Storage Manager icon.

The Storage Manager menu opens:

3.

Select the memory card from the drop-down list.

4.

Press the Dismount button to dismount the memory card. All partitions on the card will be dismounted.

5.

Press the Format button to format the memory card.

Warning: All partitions and information on the card will be erased during the formatting process.

5.9.2 Creating Partitions

Once the card is formatted, new partitions can be created in it. The default is to create one partition that occupies the whole card, but a card can be divided into more than one partition if desired. Each partition appears as a separate folder in

Windows Explorer.

To create new partitions:

130 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Creating Partitions

1.

Press the New button next to the Partitions list box. The New Partition dialog appears:

2.

Enter a name for the partition.

3.

If more than one partition is desired, uncheck the Use All Available

Disk Space checkbox, then specify the desired number of sectors to be used by the partition:

Note: The sector size of the card is given on the left-hand side of the Storage

Properties dialog.

4.

Press OK . The new partition appears in the Partitions list:

The new partition is automatically mounted. This is indicated by an asterisk (*) next to its name in the partition list. Any unallocated space on the card is indicated at the left, and additional partitions can be created in it.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 131

Chapter 5: Configuration

Partition Management

5.9.3 Partition Management

Partitions can be individually dismounted, mounted, deleted, or formatted as well.

These and additional tasks are available from the Partition Properties dialog:

To dismount a partition:

1.

Select the desired partition.

2.

Press the Properties button. The Partition Properties dialog appears.

3.

Press the Dismount button. The partition is dismounted. The asterisk disappears next to its name in the partitions list.

To delete a partition:

1.

Select the desired partition.

2.

Press the Delete button. A warning dialog appears.

3.

Press the OK button. The partition is deleted.

To format a partition:

1.

Select the desired partition.

2.

Press the Properties button. The Partition Properties dialog appears.

3.

Press the Dismount button. The partition is dismounted. The asterisk disappears next to its name in the partitions list.

132 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

4.

Press the Format button. The Format dialog appears:

Chapter 5: Configuration

Partition Management

5.

Choose your format options. These options include:

• Version of file system (FAT-16, for devices holding up to 4 GB; or

FAT-32, for devices containing up to 32 GB).

• Number of FATs (File-Allocation Tables).

• Number of entries allowed in the root directory.

• Cluster size (.5 KB to 64 KB).

There are also two checkboxes, which govern:

• Whether to use the transaction-safe FAT file system (TFAT). This file system keeps multiple copies of the file-allocation table, changing one while maintaining another as a backup.

• Whether to perform a quick format. Quick formatting removes all reference to data in the partition without erasing the actual partition. The partition will be treated as empty, and new data will overwrite it.

6.

Press Start . The partition is formatted.

To mount a partition:

1.

Select the desired partition.

2.

Press the Properties button. The Partition Properties dialog appears.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 133

Chapter 5: Configuration

IPv6 Support

3.

Press the Mount button. The partition is mounted. The asterisk appears next to its name in the partitions list.

The Partition Properties dialog has buttons for additional functions. Partitions can be defragmented, and their file structure can be scanned.

5.10 IPv6 Support

The IPv6 Support icon in the Control Panel allows you to activate IPv6 network support on your unit if your network setup requires this. This internet protocol specification (version 6) supports 128-bit IP addresses, replacing version 4.

Figure 5.18 IPv6 Support Icon

• Choose the IPv6 Support icon to display the associated dialog box.

• Choose the checkbox next to Enable IPv6 Network Support to enable this internet protocol.

134 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Scanner Settings

5.11 Scanner Settings

The Teklogix Scanners icon in the Control Panel provides dialog boxes in which you can tailor bar code options and choose the bar codes your scanner will recognize. The parameters are preset with the default settings of the decoded scanner installed in the unit.

If you wish to recover the factory defaults after making changes, the defaults can be applied to a selected parameter, sub-tree of parameters, or all scanner parameters.

Using the stylus, holding on a symbology will pop up a menu to default the sub-tree, or all settings. Holding on an individual setting will pop up a menu to default that setting, or all settings. This option cannot be accessed without a touchscreen.

For a listing of available scanners and their specifications, please refer to Chapter 7:

“Specifications”.

Figure 5.19 Teklogix Scanners Icon

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 135

Chapter 5: Configuration

Bar Codes

5.11.1 Bar Codes

5.11.1.1 Scanner

The dropdown menu to the right of the Scanner option allows you to choose from one of the following scanner types used with your hand-held: Decoded (internal),

Decoded (HHP), Decoded (Intermec ISCP) and Imager.

The symbologies listed change to reflect the scanner you choose and the bar codes it supports.

Important: To improve the decode speed and performance, enable only those codes that are required by the application.

Keep in mind that some bar code types are only available when an internal imaging scanner is installed. All internal scanners can be configured using the Barcode dialog boxes.

136 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

5.11.2 Decoded (Internal) Scanners

Chapter 5: Configuration

Decoded (Internal) Scanners

• Tap on the Scanner drop-down menu, and choose Decoded (internal) .

5.11.2.1 Options

Note: Some options are available only for specific scanners. Refer to the option names in this section for scanner model identification.

Dot Time (msec)

The value selected for “Dot Time (msec)” determines (in milliseconds) how long the targeting dot remains on before the scanner switches to a normal scan sweep.

When you double-tap on this parameter, a dialog box is displayed in which you can enter a value of 0 msec, 200 msec or 400 msec. A value of 0 (zero) disables the target dot.

Aim Duration

This parameter determines the total time the aiming pattern appears before the scanner laser begins sweeping. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value from 0 to 30 (0 to 3 sec.). A value of 0

(zero) disables the aiming-dot.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 137

Chapter 5: Configuration

Decoded (Internal) Scanners

Laser On Time

The value assigned to this parameter determines how long the laser will remain on when the scan button or trigger is pressed.Double-tapping on this parameter displays a dialog box in which you can enter a value between 5 and 99 , each number representing 0 .

1 seconds.

5.11.2.2 Decoded (Internal) Advanced Options

Continuous Scan Mode

Setting this parameter to ‘on’ keeps the laser on and continuously decoding as long as the scanner button is pressed and held down.

Minimum Cancel Time

The value assigned to this parameter determines the time delay before the scanner is turned off, once the scanner trigger or button is released. This gives the scanner a minimum amount of time to complete its current decode before the scan is cancelled when the user quickly triggers on/off.

Low Power Timeout

To extend laser life, you can select the time the scanner remains active following a successful decode. The scanner wakes from low power mode when a bar code is scanned—a successful decode restores normal blinking.

This is only used if the unit’s Trigger Mode has been changed to Continuous On. If the unit is used in a fixed mount this parameter might be used, but not if the unit is used as a hand-held.

When you double-tap on this parameter, a dialog box is displayed in which you can choose a value of 30 sec., 1 min., 2 min. or 3 min.

Parameter Scanning

Setting this parameter to ON enables decoding of parameter bar codes.

Linear Security Level

This parameter allows you to select the security level appropriate for your bar code quality. There are four levels of decode security for linear code types (e.g., Code 39,

Interleaved 2 of 5). Higher security levels should be selected for decreasing levels of bar code quality. As security levels increase, the scanner’s decode speed decreases.

138 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Internal) Scanners

Double-tapping on this parameter displays a dialog box in which you can enter a value from 1 to 4.

Linear security level 1 specifies that the following code types must be successfully read twice before being decoded:

Code Type

Codabar

MSI Plessey

D 5 of 5

I 2 of 5

Length

All

4 or less

8 or less

8 or less

“Linear security level 2” specifies that all types of codes must be successfully read twice before being decoded.

“Linear security level 3” specifies that code types other than the following must be successfully read twice before being decoded. The following codes must be read three times:

Code Type

MSI Plessey

D 2 of 5

I 2 of 5

Length

4 or less

8 or less

8 or less

“Linear security level 4” requires that all code types be successfully read three times before being decoded.

Bi-Direction Redundancy

Note: This parameter is only valid if a” Linear Security Level” is enabled.

When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.

5.11.2.3 Decoded (Internal) 2D Scanning Options

Scanning Mode

When you double-tap on this parameter, a dialog box is displayed in which you can choose one of the following scanning modes: Smart Raster, Always Raster,

Programmable Raster, Slab Pattern, Cyclone Pattern or Semi-Omni Pattern.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 139

Chapter 5: Configuration

Decoded (Internal) Scanners

Raster Height And Raster Expand Rate

These parameter determine the laser pattern’s height and rate of expansion.

Note: These parameters are only used when either Programmable Raster or

Always Raster is assigned to the “2D Scanning Mode” parameter.

“2D Raster Height” and “2D Raster Expand Rate” are intended for very specific applications and are usually not required for normal scanning purposes.

Double-tapping on this parameter displays a dialog box in which you can enter a value from 1 to 15 .

5.11.2.4 Decoded (Internal) 2D Scanning Options

Transmit Code ID Char

A code ID character identifies the scanned bar code type. In addition to any single character prefix already selected, the code ID character is inserted between the prefix and the decoded symbol.

When you double-tap on this parameter, a dialog box is displayed in which you can choose a transmit code: None , AIM or Symbol .

Scan Data Format

This parameter allows you to change the scan data transmission format.

Double-tapping on “Scan Data Format” displays the following options from which you can choose a data format: data (as-is), data [S1], data [S2], data [S1][S2],

[P] data, [P] data [S1], [P] data [S2] and [P] data [S1][S2].

Prefix [P], Suffix [S1] And Suffix [S2]

A prefix and/or one or two suffixes may be appended to scan data for use in data editing.

When you double-tap on these parameters, a dialog box is displayed in which you can enter a value from 0 to 255.

Delete Char Set ECIs

Setting this parameter to on enables the scanner to delete any escape sequences representing Character Set ECIs – Extended Channel Interpretations (also known as

GLIs) from its buffer before transmission.

140 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Internal) Scanners

When this parameter is enabled, the scanner transmits data from PDF417 and

MicroPDF417 bar codes containing Character Set ECIs, even when the ECI

Protocol is disabled.

ECI Decoder

Setting this parameter to on enables the scanner to interpret any Extended Channel

Interpretations (ECIs) supported by the scanner. This parameter has no effect on symbols that were not encoded using ECIs.

If this parameter is set to off and a symbol that was encoded using an ECI escape is scanned, the scanner transmits the ECI escape followed by the data that was not interpreted.

5.11.2.5 Code 39

Enabled

Setting this parameter to on enables “Code 39”.

Enable Trioptic Code 39

Note: “Trioptic Code 39” and “Full ASCII” should not be enabled simultaneously. The scanner does not automatically discriminate between these two symbologies.

Trioptic Code 39 symbols always contain six characters. Setting this parameter to on allows this type of symbology to be recognized.

Convert To Code 32

Note: “Code 39” must be enabled in order for this parameter to function.

Setting this parameter to on allows the scanner to convert the bar code from “Code

39” to “Code 32”.

Code 32 Prefix

Note: “Convert to Code 32” must be enabled in order for this parameter to function.

When this parameter is enabled, the prefix character “A” is added to all “Code 32” bar codes.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 141

Chapter 5: Configuration

Decoded (Internal) Scanners

Set Length L1 And Set Length L2

Lengths for “Code 39” can be set for Any length , Length within a range , One discrete length or Two discrete lengths . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be decoded by your scanner

Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 1 to 55.

Check Digit Verification

When this parameter is enabled (set to on ), the integrity of a “Code 39” symbol is checked to ensure that it complies with specified algorithms.

Note: Only those “Code 39” symbols that include a Mod 43 check digit are decoded when this parameter is enabled.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must to enabled.

Full ASCII

If this parameter is enabled, the characters +, %, and / are used as escape characters.

The combination of an escape character and the next character is converted to an equivalent ASCII character.

Decode Performance

If this parameter is enabled, one of three decode levels can be chosen in the “Decode

Performance Level” parameter.

142 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Internal) Scanners

Decode Perf. Level

This parameter provides three levels of decode performance or “aggressiveness” for

Code 39 symbols. Increasing the performance level reduces the amount of required bar code orientation – this is useful when scanning very long and/or truncated bar codes. Keep in mind that increased levels reduce decode security.

When you double-tap on this parameter, a dialog box is displayed in which you can enter a decode performance level of between 1 and 3.

Field Size/Chars

Field Size

The field size is the length of the field after the first character is stripped and the prefix and suffix characters are added. If the field size is non-zero, only bar codes of that length are passed through.

Prefix Char

This character, if non-zero, is added before a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The

ASCII/Unicode key value of the keypress is displayed.

Suffix Char

This character, if non-zero, is added after a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The

ASCII/Unicode key value of the keypress is displayed.

Strip Leading

This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added.

Note: For Code 39 bar codes, the “AIAG Strip” is performed before the

“Strip Leading”.

Strip Trailing

The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 143

Chapter 5: Configuration

Decoded (Internal) Scanners

5.11.2.6 Code 128

Enabled

Set this parameter to on to enable “Code 128”.

Enable GS1-128/GS1 US

Previously UPC/EAN and

UCC

, these types of bar codes include group separators and start codes.

Enable ISBT 128

To successfully scan this variation, “Enable ISBT 128” must be set to on .

Decode Performance

If this parameter is set to on , one of three decode levels assigned to the “Decode

Performance Level” parameter can be selected.

Decode Perf. Level

This parameter provides three levels of decode performance or “aggressiveness” for

Code 128 symbols. Increasing the performance level reduces the amount of required bar code orientation – this is useful when scanning very long and/or truncated bar codes. Keep in mind that increased levels reduce decode security.

When you double-tap on this parameter, a dialog box is displayed in which you can enter a decode performance level of between 1 and 3 .

Field Size/Chars

Refer to page 143 for details.

5.11.2.7 EAN 13

Enabled

Set this parameter to on to enable “EAN 13”.

Prefix/Suffix

Prefix Char

This character, if non-zero, is added before a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The

ASCII/Unicode key value of the keypress is displayed.

144 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Internal) Scanners

Suffix Char

This character, if non-zero, is added after a successfully decoded bar code. Press the key you want to insert in the dialog box attached to this parameter. The

ASCII/Unicode key value of the keypress is displayed.

Strip Leading

This parameter determines the number of characters that will be removed from the beginning of the bar code before the prefix character is added.

Note: The appended character is treated as any other keyboard character.

For example, if [BKSP] is pressed, the usual action for that key is performed.

Strip Trailing

The value entered in this parameter determines the number of characters that will be removed from the end of the bar code before the suffix character is added.

5.11.2.8 EAN 8

Enabled

Set this parameter to ON to enable “EAN 8”.

EAN-8 Zero Extend

When this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols, making them compatible in format to EAN-13 symbols. Disabling this parameter returns EAN-8 symbols to their normal format.

Prefix/Suffix

See “Prefix/Suffix” beginning on page 144.

5.11.2.9 UPC A

Enabled

Set this parameter to ON to enable “UPC A”.

UPC-A, Check Digit

If you enable this parameter, the check digit is included with the decoded bar code data.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 145

Chapter 5: Configuration

Decoded (Internal) Scanners

UPC-A, Preamble

When you double-tap on this parameter, a dialog box is displayed where you can choose one of three options for lead-in characters for UPC-A symbols transmitted to the host device:

System Char – system character transmitted with the data,

Country Code and System Char – both the country code (“0” for USA) and system character are transmitted with the data, or

None – no preamble is transmitted. The lead-in characters are considered part of the symbol.

Prefix/Suffix

See “Prefix/Suffix” beginning on page 144.

5.11.2.10 UPC E

Enabled UPC-E

Set this parameter to ON to allow “UPC E” bar code scans.

Enabled UPC-E1

Set this parameter to ON to allow “UPC-E1” (zero suppressed) bar code scans.

UPC-E And UPC-E1 Check Digit

If you enable one or both of these parameters, a check digit is included with the decoded bar code data.

UPC-E And UPC-E1 Preamble

When you double-tap on one of these parameters, a dialog box is displayed where you can choose one of three options for lead-in characters for UPC-E and UPC-E1 symbols transmitted to the host device:

System Char – system character transmitted with the data,

Country code and System Char – both the country code (“0” for USA) and system character are transmitted with the data, or

None – no preamble is transmitted. The lead-in characters are considered part of the symbol.

146 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Internal) Scanners

Conv. UPC-E To UPC-A

This parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).

Conv. UPC-E1 To UPC-A

This parameter converts UPC-E1 (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).

Prefix/Suffix

Refer to “Prefix/Suffix” beginning on page 144.

5.11.2.11 UPC/EAN Shared Settings

The parameters you set here are a shared across all available UPC and EAN bar codes.

Enable Bookland EAN

Setting this parameter to ON allows your scanner to recognize Bookland EAN bar codes.

Supplementals

'Supplementals” are additionally appended characters (2 or 5).

Double-tapping this parameter displays a list of options. If Ignore is chosen,

UPC/EAN is decoded and the supplemental characters are ignored. If Decode is chosen, UPC/EAN symbols are decoded with supplementals. Autodiscriminate works in conjunction with the Supp. Redundancy parameter.

Supp. Redundancy

With “Autodiscriminate” selected in the “Supplementals” parameter, “Supp.

Redundancy” adjusts the number of times a symbol without supplementals is decoded before transmission.

When you double-tap on this parameter, a dialog is displayed in which you can enter a value between 2 and 20. A value of 5 or above is recommended when

Autodiscriminate is selected and you are decoding a mix of UPC/EAN symbols with and without supplementals.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 147

Chapter 5: Configuration

Decoded (Internal) Scanners

Security Level

This parameter controls the tolerance for decoding edge-to-edge UPC/EAN bar codes. Double-tapping on this parameter displays a dialog box in which you can choose a level from 0 to 3. Lower values have a lower tolerance for misreads, but they also increase the time it takes to decode the bar code.

Linear Decode

“Linear Decode” applies to code types containing two adjacent blocks (e.g.,

UPC-A, EAN-8, EAN-13). When enabled (set to on ), a bar code is transmitted only when both the left and right blocks are successfully decoded within one laser scan.

This option should be enabled when bar codes are in proximity to each other.

2D UPC Half Block Stitching

Setting this parameter to ON enables “UPC Half Block Stitching” for the SE 3223 omnidirectional engine only.

5.11.2.12 Code 93

Enabled

Set this parameter to on to enable “Code 93” or off to disable it.

Set Length L1 And Set Length L2

Lengths for “Code 93” can be set for Any length , Length within a range , One discrete length or Two discrete lengths . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner.

Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 4 to 55.

Field Size/Char

Refer to page 143 for details.

148 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Internal) Scanners

5.11.2.13 Codabar

Enabled

Set this parameter to ON to enable “Codabar”.

Set Length L1 And Set Length L2

Lengths for “Codabar” can be set for Any length , Length within a range , One discrete length or Two discrete lengths . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner.

Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 5 to 55.

CLSI Editing

When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol.

Note: Symbol length does not include start and stop characters.

NOTIS Editing

When enabled, this parameter strips the start and stop characters from decoded

Codabar symbol.

Field Size/Chars

Refer to page 143 for details.

5.11.2.14 MSI Plessey

Enabled

Set this parameter to on to enable “MSI Plessey”.

Set Length L1 And Set Length L2

Lengths for “MSI Plessey” can be set for Any length , Length within a range , One discrete length or Two discrete lengths . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 149

Chapter 5: Configuration

Decoded (Internal) Scanners

Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner.

Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 6 to 55.

Check Digits

Double-tapping on this parameter displays a dialog box in which you can choose

One or Two check digit(s).

If this parameter is set to One , it is assumed that the last digit is a check digit. If

“Check Digits” is set to Two , it is assumed that the last two digits are check digits.

Note: If Two check digits is selected, an MSI Plessey “Check Digit Algorithm: must also be selected. See below for details.

Transmit Check Digit

If this parameter is enabled, the check digit is included with the bar code data.

Check Digit Algorithm

When the Two MSI Plessey check digits option is selected, an additional verification is required to ensure integrity. Double-tapping on this parameter displays a dialog box n which you can choose the algorithm to be used: MOD 10/MOD 11 or

MOD 10/MOD 10.

Field Size/Chars

Refer to page 143 for details.

5.11.2.15 Interleaved 2 of 5

Enabled

Set this parameter to ON to enable “Interleaved 2 of 5”.

Set Length L1 And Set Length L2

Lengths for “Interleaved 2 of 5” can be set for Any length , Length within a range ,

One discrete length or Two discrete lengths . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

150 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Internal) Scanners

Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner.

Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 4 to 14.

Check Digit Verification

When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm – either USS (Uniform Symbology

Specification) or OPCC (Optical Product Code Council).

Transmit Check Digit

If this parameter is enabled, the check digit is included with the bar code data.

Convert To EAN 13

If this parameter is enabled, the I 2 of 5 bar code is converted to EAN 13.

Field Size/Char

Refer to page 143 for details.

5.11.2.16 Discrete 2 of 5

Enabled

Set this parameter to on to enable “Discrete 2 of 5”.

Set Length L1 And Set Length L2

Lengths for “Discrete 2 of 5” can be set for Any length , Length within a range , One discrete length or Two discrete lengths . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner.

Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 1 to 12.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 151

Chapter 5: Configuration

Decoded (Internal) Scanners

Field Size/Char

Refer to page 143 for details.

5.11.2.17 RSS Code

Enable

Setting this parameter to on enables “2D RSS Code” scanning capability.

Enable RSS-14 (Reduced Space Symbology)

RSS-14 code can be either purely linear or split in half with one half stacked on top of the other half. Stacking the code reduces the bar code length, and providing the nominal height of the code is maintained, it can be omni-directionally scanned.

Enable RSS Limited

“RSS-Limited” is restricted, in that it can only encode 14 digit GTINs (global trade item number) that begin with either a 0 or a 1 . It is not stackable and is not designed to be read omni-directionally.

Enable RSS Expanded

“RSS Expanded” uses the same application identifiers as UCC/EAN-128 codes but it can be split into sections and stacked several rows high, reducing the length of the symbol, while increasing the capacity of data that can be stored. “RSS Expanded” code can be omni-directionally scanned

.

Field Size/Char

Refer to page 143 for details.

5.11.2.18 Composite

Important: To successfully read this type of bar code, the two types of symbologies included in a composite bar code must be enabled.

In addition, “Center Bar Code Only” must be disabled.

A composite symbol includes multi-row 2D components making it compatible with linear and area CCD scanners along with linear and rastering laser scanners.

The options available for this parameter represent multi-level components of a composite symbol.

152 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Internal) Scanners

Enable CC-C And Enable CC-AB

To activate these components, set these parameters to on .

Enable TLC-39

This composite component integrates MicroPDF417 with the linear code. Setting this parameter to on enables this parameter.

5.11.2.19 PDF-417

Enable

Setting this parameter to on enables PDF-417 two dimensional (2D) coding.

Field Size/Char

Refer to page 143 for details.

5.11.2.20 Micro PDF-417

Enable

Setting this parameter to on enables “Micro PDF-417” bar code scanning. Micro

PDF-417 is a multi-row symbology that is useful for applications requiring greater area efficiency but lower data capacity than PDF-417.

Code 128 Emulation

When this parameter is enabled, the scanner transmits data from certain Micro

PDF-417 symbols as if it was encoded in Code 128 symbols.

If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are transmitted with one of the following prefixes:

]C1if the first codeword is 903-907, 912, 914, 915

]C2if the first codeword is 908 or 909

]C0if the first codeword is 910 or 911

If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted with one of the following prefixes:

]L3if the first codeword is 903-907, 912, 914, 915

]L4if the first codeword is 908 or 909

]L5if the first codeword is 910 or 911

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 153

Chapter 5: Configuration

Decoded (HHP)

Field Size/Char

Refer to page 143 for details.

5.11.3 Decoded (HHP)

5.11.3.1 Decoded (HHP) Scanner Options

Laser On Time

The value assigned to this parameter determines how long the laser will remain on when the scan button or trigger is pressed.

Double-tapping on this parameter displays a dialog box in which you can enter a value from 1 to 10 .

5.11.3.2 Decoded (HHP) Advanced Options

Continuous Scan Mode

Setting this parameter to on keeps the laser on and continuously decoding as long as the scanner button is pressed and held down.

Minimum Cancel Time

The value assigned to this parameter determines the time delay before the scanner is turned off, once the scanner trigger or button is released. This gives the scanner a minimum amount of time to complete its current decode before the scan is cancelled when the user quickly triggers on/off.

154 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (HHP)

Low Power Timeout

To extend laser life, you can select the length of time the scanner remains active following a successful decode. The scanner wakes from low power mode when a bar code is scanned – a successful decode restores normal blinking.

When you double-tap on this parameter, a dialog box is displayed in which you can choose a value of 30 sec, 1 min, 2 min or 3 min.

Note: This parameter is only used if the Trigger Mode has been set to Continuous On and the hand-held is mounted in a fixed position; otherwise, ‘Low

Power Timeout’ is not used.

5.11.3.3 Code 39

Enabled

Setting this parameter to on enables “Code 39”.

Strip Start/Stop Chars

Codabar uses the characters A, B, C, and D as start and stop characters. Thus, the first and last digits of a Codabar message must be A, B, C, or D, and the body of the message should not contain these characters. Setting this parameter to on strips the start and stop characters from this bar code.

Check Char

When this parameter is set to Validate only , the integrity of a “Code 39” symbol is checked to ensure that it complies with specified algorithms.

If “Check Char” is set to Validate and Transmit , the check character is validated and transmitted with the data.

Setting this parameter to None disables this function.

Minimum And Maximum Length

Minimum and Maximum lengths for the bar code can be set from 0 to 48 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 155

Chapter 5: Configuration

Decoded (HHP)

Append

If this parameter enabled, any Code 39 bar code that contains a space as the first character will be “stored in memory”. Once a Code 39 barcode containing a non-space first character is scanned, this bar code will be appended to the bar codes containing the spaces and the imager will transmit the ALL the data. The spaces are then removed.

Pharmaceutical

This is a numeric (0-9) fixed length barcode used by Italian pharmacies. It is also referred to as Code 32 Pharmacode and is a form of Code 39.

Full ASCII

If this parameter is enabled, the characters +, %, and / are used as escape characters.

The combination of an escape character and the next character is converted to an equivalent ASCII character.

Field Size/Char

Refer to page 143 for details.

5.11.3.4 Trioptic Code

This code is used for labeling magnetic storage media.

Note: If you are scanning Code 32 Pharmaceutical codes, Trioptic Code must be off.

5.11.3.5 Code 128

Enabled

Setting this parameter to on enables “Code 128”.

ISBT Concatenation

These codes are not concatenated by default. You need to set this parameter to on to send concatenated code.

156 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (HHP)

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 0 to 80.

Field Size/Char

Refer to page 143 for details.

5.11.3.6 EAN 13 Settings

Enabled

Set this parameter to on to enable “EAN 13”.

Check Digit

If you enable this parameter, a check digit is included with the decoded bar code data.

Addendum Add-on 2 And Addendum Add-on 5

An addendum is a separate bar code, supplementary to the main bar code.

Enabling these parameters defines the length of the addendum bar code to either 2 or 5 characters.

Addendum Required

When this parameter is set to on , the scanner does not accept the main bar code without an addendum.

Addendum Separator

“Addendum Separator” is a space that is added between the EAN 13 bar code and the Add-on code/Addenda . When this parameter is set to on , the scanner does not accept the main bar code without an addendum.

ISBN Translate

When this parameter (International Standard Book Number) is enabled, the first 3 characters (‘978’) are ignored and the checksum (0.9, ‘X’) is calculated on the remaining characters.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 157

Chapter 5: Configuration

Decoded (HHP)

Prefix/Suffix

Refer to “Prefix/Suffix” beginning on page 144.

5.11.3.7 EAN 8

Enabled

Set this parameter to on to enable “EAN 8”.

Check Digit

If you enable this parameter, a check digit is included with the decoded bar code data.

Addendum Add-on 2 And Addendum Add-on 5

An addendum is a separate bar code, supplementary to the main bar code.

Enabling these parameters defines the length of the addendum bar code to either

2 or 5 characters.

Addendum Required

When this parameter is set to on , the scanner does not accept the main bar code without an addendum.

Addendum Separator

Addendum Separator is a space that is added between the EAN 13 bar code and the

Add-on code/Addenda . When this parameter is set to on , the scanner does not accept the main bar code without an addendum.

Prefix/Suffix

Refer to “Prefix/Suffix” beginning on page 144.

5.11.3.8 UPC A Settings

Enabled

Set this parameter to on to enable “UPC A” bar code scanning recognition.

Check Digit

If you enable this parameter, a check digit is included with the decoded bar code data.

158 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (HHP)

Transmit Number System

If this parameter is enabled, the number system digit is transmitted with the decoded bar code data.

Addendum Add-on 2 And Addendum Add-on 5

An addendum is a separate bar code, supplementary to the main bar code.

Enabling these parameters defines the length of the addendum bar code to either

2 or 5 characters.

Addendum Required

When this parameter is set to on , the scanner does not accept the main bar code without an addendum.

Addendum Separator

“Addendum Separator” is a space that is added between the UPC A bar code and the

Add-on code/Addenda . When this parameter is set to on , the scanner does not accept the main bar code without an addendum.

Prefix/Suffix

Refer to “Prefix/Suffix” beginning on page 144.

5.11.3.9 UPC E Settings

Enabled

Set this parameter to on to enable “UPC E”.

Enabled UPC-E1

Set this parameter to on to allow “UPC-E1” (zero suppressed) bar code scans.

Expand

This parameter expands the UPC E code to a 12 digit UPC-A format.

Check Digit

If you enable this parameter, a check digit is included with the decoded bar code data.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 159

Chapter 5: Configuration

Decoded (HHP)

Transmit Number System

If this parameter is enabled, the number system digit is transmitted with the decoded bar code data.

Addendum Add-on 2 And Addendum Add-on 5

An addendum is a separate bar code, supplementary to the main bar code.

Enabling these parameters defines the length of the addendum bar code to either

2 or 5 characters.

Addendum Required

When this parameter is set to on , the scanner does not accept the main bar code without an addendum.

Addendum Separator

“Addendum Separator” is a space that is added between the UPC E bar code and the

Add-on code/Addenda . When this parameter is set to on , the scanner does not accept the main bar code without an addendum.

Prefix/Suffix

Refer to “Prefix/Suffix” beginning on page 144.

5.11.3.10 UPC/EAN Shared Settings

Extended Coupon Code

This parameter specifies whether or not the imager will read only UPC-A/EAN-13 bar codes that have addenda.

Note: The 2 or 5 digit addenda must be turned on/off, depending on the desired behavior.

5.11.3.11 Code 93

Enabled

Set this parameter to on to enable “Code 93”.

160 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (HHP)

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 0 to 80.

Field Size/Char

Refer to page 143 for details.

5.11.3.12 Codabar

Enabled

Set this parameter to on to enable “Codabar”.

Start/Stop Transmit

Codabar can use the following sets of characters as start and stop characters: a, b, c, d

A, B, C, D a, b, c, d, /, t, n, *, e

DC1, DC2, DC3, DC4

Thus, when a set is chosen, the first and last digits of a Codabar message must be one of those characters and the body of the message should not contain these characters. Setting this parameter to off strips the start and stop characters from this bar code.

Check Char

When this parameter is set to Validate only , the integrity of a “Code 39” symbol is checked to ensure that it complies with specified algorithms.

If “Check Char” is set to Validate and Transmit , the check character is validated and transmitted with the data.

Setting this parameter to None disables this function.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 161

Chapter 5: Configuration

Decoded (HHP)

Concatenation

“Codabar” supports symbol concatenation. When you enable Concatenation , the imager looks for a Codabar symbol with a “D” start character that is adjacent to a symbol with a “D” stop character. In this case, the two messages are concatenated into one with the “D” characters omitted.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 2 to 60.

Field Size/Char

Refer to page 143 for details.

5.11.3.13 MSI Plessey

Enabled

Set this parameter to on to enable MSI .

Enable Plessey

Set this parameter to on to enable Plessey .

Check Char

When this parameter is set to Validate only , the integrity of the symbol is checked to ensure that it complies with specified algorithms.

If “Check Char” is set to Validate and Transmit , the check character is validated and transmitted with the data.

Setting this parameter to None disables this function.

Minimum And Maximum Length

These parameters apply to MSI bar codes. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 4 to 48.

162 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (HHP)

Plessey Minimum And Plessey Maximum Length

These parameters apply to Plessey bar codes.The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 4 to 48.

Field Size/Char

Refer to page 143 for details.

5.11.3.14 Code 11

Enabled

Set this parameter to on to enable “Code 11”.

Check Digits

Double-tapping on this parameter displays a dialog box in which you can choose

One Check Digit or Two check digits .

If this parameter is set to One Check Digit , it is assumed that the last digit is a check digit. If it is set to Two Check Digits , it is assumed that the last two digits are check digits.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 80.

Field Size/Char

Refer to page 143 for details.

5.11.3.15 Interleaved 2 of 5

Enabled

Set this parameter to on to enable “Interleaved 2 of 5”.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 163

Chapter 5: Configuration

Decoded (HHP)

Check Digit

When this parameter is set to Validate only , the integrity of a symbol is checked to ensure that it complies with specified algorithms.

If “Check Digit” is set to Validate and Transmit , the check digit is validated and transmitted with the data.

Setting this parameter to None disables this function.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 80.

Field Size/Char

Refer to page 143 for details.

5.11.3.16 Matrix 2 of 5

Enabled

Set this parameter to on to enable “Matrix 2 of 5”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 80.

Field Size/Char

Refer to page 143 for details.

5.11.3.17 IATA 2 of 5

Enabled

Set this parameter to on to enable “IATA 2 of 5”.

164 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (HHP)

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 48.

Field Size/Char

Refer to page 143 for details.

5.11.3.18 Discrete 2 of 5

Enabled

Set this parameter to on to enable “Discrete 2 of 5”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 48.

Field Size/Char

Refer to page 143 for details.

5.11.3.19 Telepen

Enabled

Set this parameter to on to enable “Telepen”.

Output

If you choose AIM Output, the imager reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). If you choose Original

Output, the imager reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2).

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 165

Chapter 5: Configuration

Decoded (HHP)

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 60.

Field Size/Char

Refer to page 143 for details.

5.11.3.20 RSS Code (Reduced Space Symbology)

Enable

Setting this parameter to on enables “RSS Code” scanning capability.

Enable RSS Limited

‘RSS-Limited” is restricted, in that it can only encode 14 digit GTINs (global trade item number) that begin with either a 0 or a 1. It is not stackable and is not designed to be read omni-directionally.

Enable RSS Expanded

“RSS Expanded” uses the same application identifiers as UCC/EAN-128 codes but they can be split into sections and stacked several rows high, reducing the length of the symbol, while increasing the capacity of data that can be stored. “RSS

Expanded” code can be omni-directionally scanned

.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 74.

Field Size/Char

Refer to page 143 for details.

166 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (HHP)

5.11.3.21 PosiCode (Reduced Space Symbology)

Enable

Setting this parameter to on enables “PosiCode” scanning capability.

PosiCode

“PosiCode” is a “position” based symbology. A position based symbology de-couples the widths of the bars from their positions. The centers of the bars are specified to be laid out on a grid of equally spaced parallel lines. The distance between these grid lines is called the G-dimension and is analogous to the

X-dimension of conventional bar codes.

There are two variations of this code: PosiCode A, and PosiCode B. The options available with this parameter allow to choose A and B , A and B and Limited A or A and B and Limited B .

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 80.

Field Size/Char

Refer to page 143 for details.

5.11.3.22 Composite

Important: To successfully read this type of bar code, the two types of symbologies included in a composite bar code must be enabled.

A composite symbol includes multi-row 2D components making it compatible with linear and area CCD scanners along with linear and rastering laser scanners.

The options available for this parameter represent multi-level components of a composite symbol.

GS1 128

“GS1 128” is the GS1 implementation of the Code 128 barcode specification. The former correct name was UCC/EAN-128.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 167

Chapter 5: Configuration

Decoded (HHP)

“GS1-128” uses a series of Application Identifiers to include additional data such as best before dates, batch numbers, quantities, weights and many other attributes needed by the user.

EAN/UCC 128 Emulation

The options in this parameter allow you to turn this emulation on or off , or to enable

RSS Emulation .

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 2435.

5.11.3.23 TLC-39

This composite component integrates MicroPDF417 with the linear code.

Enabled

Setting this parameter to on enables this parameter.

Field Size/Char

Refer to page 143 for details.

5.11.3.24 PDF-417

Enabled

Set this parameter to on to enable “PDF-417”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 2750.

Field Size/Char

Refer to page 143 for details.

168 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (HHP)

5.11.3.25 Micro PDF-417

Enabled

Set this parameter to on to enable “Micro PDF-417”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 366.

Field Size/Char

Refer to page 143 for details.

5.11.3.26 Code 16K

The “Code 16K” bar code is a multiple-row bar code that can encode the full ASCII character set below ASCII 128. It uses existing UPC and Code 128 character set patterns. Up to 77 full ASCII characters or 154 numeric characters can be encoded into 2 to 16 rows. Each row is divided by a separator bar. The top and bottom of the symbol also have separator bars that extend to the ends of the minimum quiet zones.

Enabled

Set this parameter to on to enable “Code 16K”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 160.

Field Size/Char

Refer to page 143 for details.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 169

Chapter 5: Configuration

Decoded (HHP)

5.11.3.27 Code 49

The “Code 49” bar code is a multiple-row bar code that can encode the full ASCII character set below ASCII 128. Up to 49 alphanumeric characters or 81 numeric characters can be encoded into two to eight rows. Each row is divided by a separator bar. The top and bottom of the symbol also have separator bars that extend to the ends of the minimum quiet zones.

Enabled

Set this parameter to on to enable “Code 49”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 81.

Field Size/Char

Refer to page 143 for details.

5.11.3.28 Codablock

Enable

Set this parameter to on to enable “Codablock”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 2048.

Field Size/Char

Refer to page 143 for details.

5.11.3.29 2D Data Matrix

Enable

Set this parameter to on to enable “2D Data Matrix”.

170 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (HHP)

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 1500.

Field Size/Char

Refer to page 143 for details.

5.11.3.30 2D QR Code

Enabled

Set this parameter to on to enable “2D QR Code”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 3500.

Field Size/Char

Refer to page 143 for details.

5.11.3.31 2D Maxicode

Enabled

Set this parameter to on to enable “2D Maxicode”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 150.

Field Size/Char

Refer to page 143 for details.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 171

Chapter 5: Configuration

Decoded (HHP)

5.11.3.32 2D Aztec

Enabled

Set this parameter to on to enable “2D Aztec”.

Aztec Runes

Aztec Runes , the smallest type of Aztec Code symbol, has the ability to encode a very short license plate message.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 3750.

Field Size/Char

Refer to page 143 for details.

5.11.3.33 Postal: PlaNET

Enabled

Set this parameter to on to enable “Postal: PlaNET”.

Check Digit

If enabled, the check digit will be transmitted at the end of the scanned data.

Field Size/Char

Refer to page 143 for details.

5.11.3.34 Postal: PostNET

Enabled

Set this parameter to on to enable “Postal: PostNET”.

Check Digit

If enabled, the check digit will be transmitted at the end of the scanned data.

172 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (HHP)

Field Size/Char

Refer to page 143 for details.

5.11.3.35 Postal: Australian

Enabled

Set this parameter to on to enable “Postal: Australian”.

Field Size/Char

Refer to page 143 for details.

5.11.3.36 Postal: Canadian

Enabled

Set this parameter to on to enable “Postal: Canadian”.

Field Size/Char

Refer to page 143 for details.

5.11.3.37 Postal: China

Enabled

Set this parameter to on to enable “Postal: China”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 2 to 80.

Field Size/Char

Refer to page 143 for details.

5.11.3.38 Postal: Japanese

Enabled

Set this parameter to on to enable “Postal: Japanese”.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 173

Chapter 5: Configuration

Decoded (HHP)

Field Size/Char

Refer to page 143 for details.

5.11.3.39 Postal: Kix

Enabled

Set this parameter to on to enable “Postal: Kix”.

Field Size/Char

Refer to page 143 for details.

5.11.3.40 Postal: Korean

Enabled

Set this parameter to on to enable “Postal: Korean”.

Minimum And Maximum Length

The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 2 to 48.

Field Size/Char

Refer to page 143 for details.

5.11.3.41 Postal: Royal

Enabled

Set this parameter to on to enable “Postal: Royal”.

Field Size/Char

Refer to page 143 for details.

174 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

5.11.4 Decoded (Intermec ISCP)

Chapter 5: Configuration

Decoded (Intermec ISCP)

• Tap on the Scanner drop-down menu, and choose Decoded (Intermec

ISCP).

5.11.4.1 Decoded (Intermec ISCP) Options

Laser On Time

The value assigned to this parameter determines how long the laser will remain on when the scan button or trigger is pressed.

Double-tapping on this parameter displays a dialog box in which you can enter a value between 1 and 10 seconds.

5.11.4.2 Decoded (Intermec ISCP) Advanced Options

Continuous Scan Mode

Setting this parameter to ‘on’ keeps the laser on and continuously decoding as long as the scanner button is pressed and held down.

Minimum Cancel Time

The value assigned to this parameter determines the time delay before the scanner is turned off, once the scanner trigger or button is released. This gives the scanner a minimum amount of time to complete its current decode before the scan is cancelled when the user quickly triggers on/off.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 175

Chapter 5: Configuration

Decoded (Intermec ISCP)

Low Power Timeout

To extend laser life, you can select the length of time the scanner remains active following a successful decode. The scanner wakes from low power mode when a bar code is scanned – a successful decode restores normal blinking.

When you double-tap on this parameter, a dialog box is displayed in which you can choose a value of 30 sec, 1 min, 2 min or 3 min.

Note: This parameter is only used if the Trigger Mode has been set to Continuous On and the hand-held is mounted in a fixed position; otherwise, ‘Low

Power Timeout’ is not used.

Parameter Scanning

Setting this parameter to Enabled allows decoding of parameter bar codes.

Same Read Validate

The data is only transmitted after repeated reads give the same result. The value assigned at this parameter determines the number of reads required, from

0 to 10 times.

Same Read Timeout

Prevents the same bar code from being read more than once. The value assigned determines after what time period the scanner will timeout, from 0 to 2550 msec.

Diff Read Timeout

Prevents unwanted reading of other bar codes on the same label. The value assigned determines after what time period the scanner will timeout, from 0 to 2550 msec.

5.11.4.3 Code 39

Enable

Setting this parameter to on enables “Code 39”.

Full ASCII

If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character.

176 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Intermec ISCP)

Reading Range

Determines the reading distance from which a bar code can be successfully scanned.

The default setting, Extended , allows for increased reading distance.

Start/Stop Transmit

Setting this parameter to on enables the transmission of start and stop characters, which are usually not transmitted. Code 39 can start and end with either a * or a $ character (see also next parameter Accepted Start Char ).

Accepted Start Char

This parameter allows the user the option of using one of the two start/stop characters or both ($ char, * char, $ and * char).

Check Digit Verification

Uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. The available options are: Disabled, MOD 43 Check, French

CIP, or Italian CIP.

Notes: French CIP (French pharmaceutical) is only used with bar codes containing 7 characters.

Italian CIP (Italian pharmaceutical) is also known as Code 32. It is transmitted as a standard Code 39 if checksum is not validated.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Char

Refer to page 143 for details.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 177

Chapter 5: Configuration

Decoded (Intermec ISCP)

5.11.4.4 Code 128

Enable

Setting this parameter to on enables “Code 128”.

GS1-128

“GS1-128” is the GS1 implementation of the Code 128 barcode specification. The former correct name was UCC/EAN-128.

GS1-128 Identifier

“GS1-128 Identifier” allows the AIM ID " ]C1" for EAN 128 to be transmitted or removed. By default, this identifier is transmitted if EAN 128 is enabled.

GTIN Compliant

GTIN (global trade item number) processing transmits EAN 128 as the 14-character

EAN/UCC GTIN. To use GTIN processing, you must activate the EAN 128 symbology.

Important: When EAN 128 and GTIN processing are both activated, it is not possible to read normal EAN 128 Codes.

FNC

1

Conversion

“FNC1 Conversion” allows the embedded FNC1 character to be converted to another character for applications that cannot use the default <GS> Group Separator or hex (1d).

Double-tapping on this option displays a dialog box listing the allowable range

– 0 to 255.

Enable ISBT 128

To successfully scan this type of bar code (International Society of Blood

Transfusion), this option must be set to on . If you enable this type of bar code, Code

128/EAN 128 is deactivated to avoid any confusion.

ISBT Concat Transmit

The codes are not concatenated by default. You need to choose one of the options provided for this parameter to send concatenated code. Choosing Only

Concatenated Codes transmits only concatenated codes—single codes will not be

178 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Intermec ISCP) transmitted. Choosing Concatenated or Single transmits single codes or concatenated codes. If only one code of a pair is read, that code will be transmitted as a single code. If both codes in a pair are detected, they will be concatenated provided that ISBT Concat Any Pair (see below) is enabled.

ISBT Concat Any Pair

Enabling this parameter causes all code pairs that can be, to be concatenated even if they do not comply with Section 4.1 of the “ISBT 128 Bar Code Symbology and

Application Specification for Labeling of Whole Blood and Blood Components”

(June 2000, Version 1.2.1).

Reading Range

Determines the reading distance from which a bar code can be successfully scanned.

The default setting Extended , allows for increased reading distance.

Check Digit Verification

The available options for this parameter are Disabled or French CIP. This parameter uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted.

Note: French CIP (French pharmaceutical) is only used with bar codes containing 7 characters.

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Char

Refer to page 143 for details.

5.11.4.5 EAN 13 Settings

Enabled

Set this parameter to on to enable “EAN 13”.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 179

Chapter 5: Configuration

Decoded (Intermec ISCP)

ISBN Conversion

When this parameter (International Standard Book Number) is enabled, the first 3 characters (‘978’) are ignored and the checksum (0.9, ‘X’) is calculated on the remaining characters.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Prefix/Suffix

Refer to “Prefix/Suffix” beginning on page 144.

5.11.4.6 EAN 8

Enabled

Set this parameter to on to enable “EAN 8”.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Convert To EAN 13

If this parameter is enabled, an EAN 8 bar code is converted to EAN 13.

Prefix/Suffix

Refer to “Prefix/Suffix” beginning on page 144.

5.11.4.7 UPC A Settings

Enabled

Set this parameter to on to enable “UPC A” bar code scanning recognition.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Transmit Number System

If this parameter is enabled, the number system digit is transmitted with the decoded bar code data.

180 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Intermec ISCP)

Convert To EAN 13

If this parameter is enabled, a UPC A bar code is converted to EAN 13.

Prefix/Suffix

Refer to “Prefix/Suffix” beginning on page 144.

5.11.4.8 UPC E Settings

Enabled

Set this parameter to on to enable “UPC E”.

Enable UPC-E1

Set this parameter to on to allow “UPC-E1” (zero suppressed) bar code scans.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Transmit Number System

If this parameter is enabled, the number system digit is transmitted with the decoded bar code data.

Convert To UPC-A

This parameter converts UPC E (zero suppressed) decoded data to UPC A format before transmission. After conversion, data follows UPC A format and is affected by UPC A programming selections (e.g. Check Digit).

Prefix/Suffix

Refer to “Prefix/Suffix” beginning on page 144.

5.11.4.9 UPC/EAN Shared Settings

The setting assigned to the “Addendum” parameter associated with this option is shared across all UPC and EAN bar codes.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 181

Chapter 5: Configuration

Decoded (Intermec ISCP)

Addendum

An addendum is a separate bar code, supplementary to the main bar code.

This parameter provides two options: Not Required but Transmitted if Read or

Required and Transmitted .

• Double-tap on Addendum to display a dialog box listing your options.

• Highlight an item, and tap on OK .

When “Addendum” is set to Not Required but Transmitted if Read , the scanner searches for an addendum and if one exists, appends it to the main bar code. When the parameter is set to Required and Transmitted , the scanner does not accept the main bar code without an addendum.

Addendum Add-on 2 And Addendum Add-on 5

Enabling these parameters sets the length of the addendum bar code to either 2 or

5 characters.

GTIN Compliant

GTIN (global trade item number) processing transmits EAN 128 as the 14-character

EAN/UCC GTIN. To use GTIN processing, you must activate the EAN 128 symbology.

Important: When EAN 128 and GTIN processing are both activated, it is not possible to read normal EAN 128 Codes.

Reading Range

This parameter determines the reading distance from which a bar code can be successfully scanned. The default setting, Extended , allows for increased reading distance.

5.11.4.10 Code 93

Enabled

Set this parameter to on to enable “Code 93”.

182 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Intermec ISCP)

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Char

Refer to page 143 for details.

5.11.4.11 Codabar

Enabled

Set this parameter to on to enable “Codabar”.

Start/Stop Transmit

Codabar can use the following sets of characters as start and stop characters: a, b, c, d

A, B, C, D a, b, c, d, /, t, n, *, e

DC1, DC2, DC3, DC4

Thus, when a set is chosen, the first and last digits of a Codabar message must be one of those characters and the body of the message should not contain these characters. Setting this parameter to Not Transmitted strips the start and stop characters from this bar code.

CLSI Library System

When enabled, spaces are inserted after characters 1, 5, 10 in the 14-character label

(used in the USA by libraries using the CLSI system).

Check Digit Verification

When enabled, this parameter checks the integrity of a symbol to ensure it complies with a specified algorithm – either USS (Uniform Symbology Specification) or

OPCC (Optical Product Code Council).

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 183

Chapter 5: Configuration

Decoded (Intermec ISCP)

Set Length L1, Set Length L2, And Set Length L3

Lengths for “Codabar” can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner.

Length Mode

You can choose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length.

Field Size/Char

Refer to page 143 for details.

5.11.4.12 MSI Plessey

Enabled

Set this parameter to on to enable “MSI”.

Enable Plessy

Set this parameter to on to enable “Plessy”.

Check Digit Verification

The available options for this parameter are MOD 10 Check and Double MOD 10

Check . This parameter uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Plessy Transmit Check Digit

If the check digit is to be transmitted with the Plessy data, this parameter must be enabled.

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

184 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Intermec ISCP)

Plessy Minimum Length

Minimum lengths for the Plessy bar code can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Char

Refer to page 143 for details.

5.11.4.13 Code 11

Enabled

Set this parameter to on to enable “Code 11”.

Check Digit Verification

The available options for this parameter are MOD 10 Check and Double MOD 10

Check .This parameter uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Char

Refer to page 143 for details.

5.11.4.14 Interleaved 2 of 5

Enabled

Set this parameter to on to enable “Interleaved 2 of 5”.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 185

Chapter 5: Configuration

Decoded (Intermec ISCP)

Reading Range

This parameter determines the reading distance from which a bar code can be successfully scanned. The default setting, Extended , allows for increased reading distance.

Check Digit Verification

The available options for this parameter are Disabled , MOD 10 Check and French

CIP . “Check Digit Verification” uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted.

Note: French CIP (French pharmaceutical) is only used with bar codes containing 7 characters.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Set Length L1, Set Length L2, And Set Length L3

Lengths for “Interleaved 2 of 5” can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner.

Length Mode

You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length.

Field Size/Char

Refer to page 143 for details.

5.11.4.15 Matrix 2 of 5

Enabled

Set this parameter to on to enable “Matrix 2 of 5”.

186 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Intermec ISCP)

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Char

Refer to page 143 for details.

5.11.4.16 Discrete 2 of 5

Enabled

Set this parameter to on to enable “Discrete 2 of 5”.

Standard 2 of 5 Format

This parameter allows you to choose a standard format – either Identicon (6 start/stop bars) or Computer Identics (4 start/stop bars) .

Check Digit Verification

The available options for this parameter are Disabled and MOD 10 Check . “Check

Digit Verification” uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Set Length L1, Set Length L2, And Set Length L3

Lengths for “Discrete 2 of 5” can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner.

Length Mode

You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length .

Field Size/Char

Refer to page 143 for details.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 187

Chapter 5: Configuration

Decoded (Intermec ISCP)

5.11.4.17 Telepen

Enabled

Set this parameter to on to enable “Telepen”.

Format

This parameter allows you to set the bar code character format to either ASCII or Numeric .

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255 . The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Field Size/Char

Refer to page 143 for details.

5.11.4.18 RSS Code (Reduced Space Symbology)

Enable

Setting this parameter to on enables “RSS Code” scanning capability.

Enable RSS-14

RSS-14 code can be either purely linear or split in half with one half stacked on top of the other half. Stacking the code reduces the bar code length, and providing the nominal height of the code is maintained, it can be omni-directionally scanned.

Enable RSS Limited

“RSS-Limited” is restricted, in that it can only encode 14 digit GTINs (global trade item number) that begin with either a 0 or a 1. It is not stackable and is not designed to be read omni-directionally.

Enable RSS Expanded

“RSS Expanded” uses the same application identifiers as UCC/EAN-128 codes but they can be split into sections and stacked several rows high, reducing the length of the symbol, while increasing the capacity of data that can be stored. “RSS

Expanded” code can be omni-directionally scanned

.

188 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Decoded (Intermec ISCP)

Field Size/Char

Refer to page 143 for details.

5.11.4.19 PDF-417

Enabled

Set this parameter to on to enable “PDF-417”.

Field Size/Char

Refer to page 143 for details.

5.11.4.20 Micro PDF-417

Enabled

Set this parameter to on to enable “Micro PDF-417”.

Code 128 Emulation

When this parameter is enabled, the scanner transmits data from certain Micro

PDF-417 symbols as if it was encoded in Code 128 symbols.

If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are transmitted with one of the following prefixes:

]C1if the first codeword is 903-907, 912, 914, 915

]C2if the first codeword is 908 or 909

]C0if the first codeword is 910 or 911

If Code 128 Emulation is set to off , the Micro PDF-417 symbols are transmitted with one of the following prefixes:

]L3if the first codeword is 903-907, 912, 914, 915

]L4if the first codeword is 908 or 909

]L5if the first codeword is 910 or 911

Field Size/Char

Refer to page 143 for details.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 189

Chapter 5: Configuration

Imager

5.11.4.21 Codablock

Enable Codablock A

Set this parameter to on to enable “Codablock type A”.

Enable Codablock F

Set this parameter to on to enable “Codablock type F”.

Field Size/Char

Refer to page 143 for details.

5.11.5 Imager

• Tap on the Scanner drop-down menu, and choose Imager .

5.11.5.1 Imager Options

Tek I mager Enabled

Setting this option to on enables the imager installed in your hand-held.

Continuous Scan Mode

Setting this parameter to on keeps image capture active and continuously decoding as long as the scanner button is pressed and held down.

Center Bar Code Only

Note: This parameter must be disabled when reading Composite bar codes.

190 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

Chapter 5: Configuration

Imager

When more than one bar code is visible in a single snap shot, this parameter allows you to specify that only the centre image within the imager framing marker be read.

When this parameter is set to on , the target dot is pointed at the centre image and only that image is returned.

Max Number Barcodes

This parameter specifies the maximum number of bar codes the imager will attempt to decode in an image. A maximum of 6 bar codes can be decoded at one time.

Barcodes Must Decode

This parameter specifies the minimum number of bar codes that the imager must decode in order to report success.

Note: This number must be less than the number of bar codes assigned to

“Max Number Barcodes”. The driver validates and reassigns the value if necessary.

Window Width

“Window Width” determines the width of the captured image in pixels.

Note: The driver will validate and reassign the value assigned to this parameter, if necessary; the driver will also use the Window Width value to horizontally center the image in the field of view.

Window Height

This parameter determines the height of the captured image in pixels.

Note: The driver will validate and reassign the value assigned to this parameter, if necessary; the driver will also use “Window Height” value to vertically center the image in the field of view.

Dot Time (msec)

The value selected for “Dot Time (msec)” determines (in milliseconds) how long the targeting dot remains on before the scanner begins capturing images. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value of between 0 and 3000. A value of 0 disables the target dot.

WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual 191

Chapter 5: Configuration

Imager

5.11.5.2 Imager Advanced Options

Important: Do not adjust the advanced options without first consulting Psion

Teklogix technical support.

Factory Defaults On Reboot

The value assigned to this parameter determines whether or not the driver will restore the factory defaults to the imager device on the next reboot.

Note: The driver will default the imager device on a ‘clean’ reset, regardless of the value of this parameter.

Min Scan Duration

This parameter defines the minimum amount of time in seconds that the imager will scan when the trigger is pressed and held down without successful decode.

Note: The actual scan duration when the trigger is pressed relies on the value assigned to Captures Per HW Trigger , below.

Captures Per HW Trigger

The value assigned to this parameter determines the number of captures the imager device will take while the imager's internal hardware trigger is held down.

Note: This parameter, together with “Min Scan Duration”, determines the actual scan duration. When the scan trigger is pressed and held down, the driver starts a timer based on the value of “Min Scan Duration” and also sends a command to emulate the hardware trigger. When completed, if the time has not yet expired, it will send another command to the imager device, forcing the imager to flash again using the value assigned to

“Captures Per HW Trigger”.

Auto Exposure

Important: This parameter value should only be changed by qualified Psion

Teklogix personnel. It should be left at the default value – ‘on’.

192 WORKABOUT PRO G2 Hand-Held With Windows Embedded CE 5.0 User Manual

advertisement

Related manuals

advertisement

Table of contents