Puls PIC480.241C is a compact and reliable power supply unit designed for industrial applications. With a 24V output and 20A current, it can deliver up to 480W of continuous power. It features active PFC, high efficiency of 95.7%, and a wide input voltage range of AC 200-240V. The unit is protected against short circuit, overload, and overvoltage, and comes with a 3-year warranty. Ideal for use in process control, automation, and other critical applications where preventive function monitoring is crucial.
advertisement
![Environment. Puls PIC480.241C-C1, PIC480.241C | Manualzz Environment. Puls PIC480.241C-C1, PIC480.241C | Manualzz](http://s3.manualzz.com/store/data/064994568_1-2fd873415b91ae3f554dbcf06cda69b6-360x466.png)
PIC480.241C, PIC480.241C-C1
24V, 20A, 480W, S
INGLE
P
HASE
I
NPUT PIANO-Series
15.
E
NVIRONMENT
Operational temperature *) -25°C to +70°C (-13°F to 158°F)
Storage temperature -40°C to +85°C (-40°F to 185°F)
Output de-rating 8W/°C
Humidity **)
Vibration sinusoidal
Shock
Altitude
5 to 95% r.h.
2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g ***)
2 hours / axis ***)
30g 6ms, 20g 11ms ***)
3 bumps / direction, 18 bumps in total
0 to 2000m (0 to 6 560ft)
2000 to 6000m (6 560 to 20 000ft)
Altitude de-rating
Over-voltage category
Degree of pollution
LABS compatibility
30W/1000m or 5°C/1000m
reduce output power according Fig. 15-1
for storage and transportation
55°C to 70°C (131°F to 158°F)
IEC 60068-2-30
IEC 60068-2-6
IEC 60068-2-27 without any restrictions reduce output power or ambient temperature,
IEC 62103, EN 50178, overvoltage category II
> 2000m (6500ft), see Fig. 15-2
III
II
IEC 62477-1, altitudes up to 2000m altitudes from 2000m to 6000m
2 IEC 62477-1, not conductive
The unit does not release any silicone or other LABS-critical substances and is suitable for use in paint shops.
*) Operational temperature is the same as the ambient or surrounding temperature and is defined as the air temperature 2cm below the unit.
**) Do not energize while condensation is present
***) Tested on a DIN-Rail with a thickness of 1.3mm.
Fig. 15-1 Output current vs. ambient temp.
Allowable Output Current at 24V
20A
15A
10A
5A
0
-25 -10 0
Ambient Temperature
+20 +40 +55 +70°C
Fig. 15-2 Output current vs. altitude
Allowed Output
Current at 24V
24A
20A
16A
12A
8A
4A
0
0
A... Tamb < 55°C
B... Tamb < 45°C
C... Tamb < 35°C
2000 4000
C
B
A
Altitude
6000m
Mar. 2021 / Rev. 1.2 DS-PIC480.241C-EN
All parameters are typical values specified at 24V, 20A output, 230Vac input , 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany
12/19
advertisement
Related manuals
advertisement
Table of contents
- 3 Intended Use
- 3 Installation Instructions
- 4 AC-Input
- 5 DC-Input
- 5 Input Inrush Current
- 6 Output
- 7 Hold-up Time
- 7 DC-OK Relay Contact
- 8 Efficiency and Power Losses
- 8 Lifetime Expectancy and MTBF
- 9 Functional Diagram
- 9 Terminals and Wiring
- 10 Front Side and User Elements
- 12 Environment
- 13 Safety and Protection Features
- 14 Dielectric Strength
- 15 Approvals and Fulfilled Standards
- 15 Regulatory Compliance
- 16 Physical Dimensions and Weight
- 17 Accessory
- 17 YR40.242 Redundancy Module
- 17 PIRD20.241 Redundancy Module
- 18 Application Notes
- 18 Back-feeding Loads
- 18 External Input Protection
- 18 Parallel Use to Increase Output Power
- 18 Parallel Use for 1+1 Redundancy
- 19 Series Operation
- 19 Inductive and Capacitive Loads
- 19 Charging of Batteries
- 19 Operation on Two Phases
- 19 Use in a Tightly Sealed Enclosure