Figure 4-61
4.8.3.4 Alarm
Before operation, please make sure you have properly connected alarm devices such as buzzer. The input mode includes local alarm, network alarm, and IPC external alarm and IPC offline alarm.
4.8.3.4.1 Local Alarm
From main menu->Setup->Event->Alarm->Local alarm, the local alarm interface is shown as in Figure
4-62. It refers to alarm from the local device.
159
Figure 4-62
Figure 4-63
160
Figure 4-64
Please refer to the following sheet for detailed information.
Parameter Function
Enable
Period
You need to check the box to enable this function.
Please select a channel from the dropdown list.
This function becomes activated in the specified periods.
There are six periods in one day. Please draw a circle to enable corresponding period.
Select date. If you do not select, current setup applies to today only. You can select all week column to apply to the whole week.
Click OK button, system goes back to local alarm interface, please click save button to exit.
Anti-dither
Sensor type
System only memorizes one event during the anti-dither period. The value ranges from 5s to 600s.
There are two options: NO/NC.
Record channel System auto activates motion detection channel(s) to record once an alarm occurs. Please note you need to set alarm record period and go to Storage-> Schedule to set current channel as schedule record.
161
Parameter
Record Delay
Alarm out
Latch
Show message
Buzzer
Alarm upload
Send Email
Function
System can delay the record for specified time after alarm ended. The value ranges from 10s to 300s.
Enable alarm activation function. You need to select alarm output port so that system can activate corresponding alarm device when an alarm occurs.
System can delay the alarm output for specified time after an alarm ended. The value ranges from 1s to 300s.
System can pop up a message to alarm you in the local host screen if you enabled this function.
Check the box here to enable this function. The buzzer beeps when an alarm occurs.
System can upload the alarm signal to the centre
(Including alarm centre).
If you enabled this function, System can send out an email to alert you when an alarm occurs.
Tour You need to click setup button to select tour channel.
System begins 1-wiindow or multiple-window tour display among the channel(s) you set to record when an alarm
occurs. See Figure 4-54.
PTZ Activation Here you can set PTZ movement when an alarm occurs.
Such as go to preset X. See Figure 4-64.
Snapshot
Click setup button to select snapshot channel. See Figure
4-55.
4.8.3.4.2 Net Alarm
From main menu->Setup->Event->Alarm->Net alarm, the network alarm interface is shown as in Figure
4-65.
Network alarm refers to the alarm signal from the network. System does not anti-dither and sensor type
setup. For setup information, please refer to chapter 4.8.3.4.1.
162
Figure 4-65
4.8.3.4.3 IPC external alarm
From main menu->Setup->Event->Alarm->IPC external alarm, the IPC external alarm interface is shown
as in Figure 4-66.
Network alarm refers to the alarm signal from the network. System does not support anti-dither and
sensor type setup. For setup information, please refer to chapter 4.8.3.4.1.
Figure 4-66
4.8.3.4.4 IPC Offline Alarm
From main menu->Setup->Event->Alarm->IPC offline alarm, the IPC offline alarm interface is shown as
163