GoodWe ESA Series User Manual
PDF
เอกสาร
โฆษณา
โฆษณา
V1.3 2025-10-31 Copyright Statement Copyright©GoodWe Technologies Co., Ltd. 2025. All rights reserved. No part of this manual can be reproduced or transmitted to the public platform in any form or by any means without the prior written authorization of GoodWe Technologies Co., Ltd. Trademarks GOODWE and other GOODWE trademarks are trademarks of GoodWe Technologies Co.,Ltd. All other trademarks or registered trademarks mentioned in this brochure are the property of their respective owners. NOTICE The information in this document is subject to change due to product updates or other reasons. This document cannot replace the product labels or the safety precautions unless otherwise specified. All descriptions in the manual are for guidance only. 1 Table of Contents 1 About This Manual 12 1.1 Overview 12 1.2 Applicable Model 12 1.3 Symbol Definition 13 2 Safety Precautions 14 2.1 General Safety 14 2.2 Personnel Requirements 14 2.3 System Safety 15 2.3.1 PV String Safety 16 2.3.2 Inverter Safety 16 2.3.3 Battery Safety 17 2.3.4 Smart Meter Safety 20 2.4 Safety Symbols and Certification Marks 20 2.5 EU Declaration of Conformity 22 2.5.1 Equipment with Wireless Communication Modules 22 2.5.2 Devices without Wireless Communication Modules (Excluding Batteries) 22 2.5.3 Battery 23 3 System Introduction 24 3.1 System Overview 24 3.2 Product Overview 38 2 3.2.1 Residential All-In-One Energy Storage System 38 3.2.2 Smart Meter 43 3.2.3 Smart Dongle 44 3.3 Supported Grid Types 45 3.4 System Modes 45 3.5 Functional Features 55 4 Check and Storage 58 4.1 Check Before Receiving 58 4.2 Deliverables 58 4.2.1 Inverter Deliverables 58 4.2.2 Battery Deliverables 60 4.2.3 Smart Meter Deliverables 61 4.2.3.1 Smart Meter Deliverables (GMK110) 61 4.2.3.2 Smart Meter Deliverables (GM330) 62 4.3 Storage 62 5 Installation 65 5.1 Installation Requirements 65 5.1.1 Installation Environment Requirements 65 5.1.2 Installation Space Requirements 66 5.1.3 Tool Requirements 67 5.2 Equipment Handling 69 5.3 Equipment Installation 70 3 5.4 Installing the Smart Meter 74 6 System Wirings 76 6.1 System Wiring Electrical Block Diagram 76 6.2 Detailed System Wiring Diagram 79 6.2.1 Detailed System Wiring Diagram for Single Inverter 80 6.2.2 Detailed System Wiring Diagram for Parallel System 88 6.3 Preparing Materials 92 6.3.1 Preparing Breakers 93 6.3.2 Preparing Cables 95 6.4 Connecting the PE Cable 97 6.5 Connecting the PV cable 98 6.6 Connecting the AC Cable 100 6.7 Connecting the Meter Cable 103 6.8 Connecting the Inverter Communication Cable 106 7 System Commissioning 111 7.1 Check Before Power ON 111 7.2 Power ON 111 7.3 Installing Protective Cover 114 7.4 Indicators 114 7.4.1 Inverter Indicators 114 7.4.2 Battery Indicators 117 7.4.3 Smart Meter Indicator 118 4 7.4.4 Smart Dongle Indicator 119 8 Rapid System Configuration 122 8.1 Downloading the App 122 8.1.1 Downloading SolarGo App 122 8.1.2 Downloading SEMS+ APP 122 8.2 Connecting the Energy Storage Inverter (Bluetooth) 123 8.3 Connect the Smart Dongle 124 8.4 Setting Communication Parameters 125 8.4.1 Setting Privacy and Security Parameters 126 8.4.2 Setting the WLAN/LAN Parameters 129 8.4.3 Setting RS485 Communication Parameters 131 8.5 Quick System Setup 131 8.5.1 Quick System Setup (Type I) 133 8.6 Power Plant Creation 137 9 System Commissioning 139 9.1 Commissioning Method Overview 139 9.2 SolarGo APP 139 9.2.1 APP Introduction 139 9.2.1.1 Downloading and Installing the App 139 9.2.1.2 Connection Method 140 9.2.1.3 Introduction of Interface 141 9.2.2 Connecting the Energy Storage Inverter (Bluetooth) 5 142 9.2.3 Connect the Smart Dongle 144 9.2.4 Introduction of the Energy Storage Inverter Interface 145 9.2.5 Setting Communication Parameters 147 9.2.5.1 Setting Privacy and Security Parameters 147 9.2.5.2 Setting the WLAN/LAN Parameters 150 9.2.5.3 Setting RS485 Communication Parameters 152 9.2.6 Setting Up the RS485 Parallel System 152 9.2.7 Quick System Setup 153 9.2.7.1 Quick System Setup (Type I) 9.2.8 Setting the Basic Information 155 159 9.2.8.1 Setting up Lightning Protection Alarm Function 160 9.2.8.2 Setting Backup Power Parameters 160 9.2.8.3 Setting up Shadow Scanning Function 162 9.2.8.4 Setting Power Adjustment Parameters 162 9.2.9 Setting Advanced Parameters 165 9.2.9.1 Setting DRED/Remote Shutdown/RCR/EnWG 14a Function 165 9.2.9.2 Setting BACK- UP N and PE Relay Switches 166 9.2.9.3 Setting the On-Grid Power Limit 167 9.2.9.3.1 Setting the On-Grid Power Limit (General) 167 9.2.9.3.2 Setting the On-Grid Power Limit (Australia) 168 9.2.9.4 Setting the AFCI Function 170 9.2.9.5 Set Battery Function 170 6 9.2.9.5.1 Setting the Lithium Battery Parameters 9.2.9.6 Setting PV Connect Mode 170 174 9.2.10 Setting Customized Safety Parameters 175 9.2.10.1 Setting Reactive Curve 176 9.2.10.2 Setting Active Curve 180 9.2.10.3 Setting Grid Protection Parameters 187 9.2.10.4 Setting Grid Connection Parameters 188 9.2.10.5 Setting Voltage Fault Ride through Parameters 190 9.2.10.6 Setting Frequency Fault Ride through Parameters 191 9.2.11 Exporting Parameters 192 9.2.11.1 Exporting Safety Parameters 192 9.2.11.2 Exporting Log Parameters 192 9.2.12 Setting Smart Meter Parameters 193 9.2.12.1 Binding/Unbinding Smart Meter 193 9.2.12.2 Meter/ CT Assisted Test 195 9.2.13 Setting Generator/Load Control Parameters 195 9.2.13.1 Setting Load Control Parameters 196 9.2.13.2 Setting Generator Parameters 198 9.2.13.3 Setting Microgrid Parameters 201 9.2.14 Equipment Maintenance 203 9.2.14.1 View Firmware Information/Firmware Upgrade 9.2.14.1.1 Regular Firmware Upgrades 7 203 203 9.2.14.1.2 One-click Firmware Upgrade 204 9.2.14.1.3 Automatic Firmware Upgrade 205 9.2.14.2 Changing Login Password 205 10 Power Plant Monitoring 208 10.1 APP Introduction 208 10.1.1 Complementary Products 208 10.1.2 Downloading and Installing the App 208 10.1.3 Connection Method 209 10.1.4 Setting Language and Server 209 10.1.5 Setting Communication Parameters 210 10.2 Account Management 210 10.2.1 Registering 210 10.2.2 Account Login 211 10.2.3 Account Switch 212 10.2.4 Account Canceling 212 10.2.5 Account Permissions 213 10.3 Setting Communication Parameters 217 10.3.1 Setting Communication Parameters via Bluetooth 217 10.3.2 Setting Communication Parameters via WiFi 220 10.4 Viewing Power Plant Information 222 10.4.1 View All Power Plant Overview Information 222 10.4.2 Viewing Monopower Plant Details 224 8 10.4.2.1 Viewing Power Plant Details (Traditional Mode) 10.4.3 Viewing Alarm Information 225 226 10.4.3.1 Viewing Alarm Information for All Power Plants 226 10.4.3.2 Viewing Alarm Information for the Current Power Plant (Traditional Mode) 227 10.4.3.3 Viewing the Current Device’s Alarm Information 228 10.4.4 Viewing Power Plant Report Information 229 10.5 Power Plant Management 231 10.5.1 Power Plant Creation 231 10.5.2 Configuring Power Plant Information 232 10.5.3 Power Plant Visitors Management 233 10.5.4 Power Plant Photos Management 234 10.5.5 Adjusting the Information Displayed on the Power Station Details Page 235 10.5.6 Setting PV Component Layout 236 10.5.7 Deleting Power Plant 237 10.5.8 Collecting Power Plant 238 10.6 Managing the Equipment in the Power Plant 238 10.6.1 Additional Equipment 239 10.6.2 Editing Device Information 240 10.6.3 Deleting Device 241 10.6.4 Upgrading Device Firmware Version 242 10.7 Remote Management Device 243 10.7.1 Setting Energy Storage Inverter Parameters 9 244 11 System Maintenance 250 11.1 Power Off the System 250 11.2 Removing the Equipment 251 11.3 Disposing of the Equipment 252 11.4 Routine Maintenance 252 11.5 Fault 253 11.5.1 Viewing Fault/Alarms Information 253 11.5.2 Fault Information and Troubleshooting 254 11.5.2.1 Inverter Troubleshooting 256 11.5.2.2 Battery Failure 326 11.5.3 Operation After Fault Clearance 344 11.5.3.1 AFCI Fault Clearance Alarm 344 12 Technical Parameters 346 12.1 Inverter Parameters 346 12.2 Technical Data 364 12.3 Smart Meter Technical Data 367 12.3.1 GMK110 367 12.3.2 GM330 367 12.4 Smart Dongle Technical Parameters 368 12.4.1 WiFi/LAN Kit-20 368 12.4.2 4G Kit- CN-G20 369 13 Appendix 371 10 13.1 FAQ 371 13.1.1 How to Conduct Auxiliary Detection for Smart Meters/ CT? 371 13.1.2 How to Upgrade the Device Version 371 13.2 Abbreviations 372 13.3 Explanation of Terms 375 13.4 Battery SN Code Meaning 376 13.5 Safety Country 377 13.6 Australia Safety Regulations 381 14 Contact Details 386 11 1 About This Manual 1.1 Overview The energy storage system consists of inverter, battery system, and smart meter. This manual describes the product information, installation, electrical connection, commissioning, troubleshooting and maintenance of the system. Read through this manual before installing and operating the products to understand product safety information and familiarize yourself with functions and features of the product. This manual is subject to update without notice. For more product details and latest documents, visit https://en.goodwe.com/. 1.2 Applicable Model The energy storage system consists the following products: Product Type Product information Description Inverter GW3K-EHA-G20 GW3.6K-EHA-G20 GW5K-EHA-G20 GW6K-EHA-G20 GW8K-EHA-G20 GW9.999K-EHA-G20 GW10K-EHA-G20 Rated output power: 3kW-10kW GW5.1-BAT-D-G20 Battery system GW5.1-BAT-D-G21 GW8.3-BAT-D-G20 GW8.3-BAT-D-G21 Smart Meter GMK110 GM330 Nominal Energy 5.12kWh Nominal Energy 8.32kWh Monitors and detects running data in the energy storage system, such as voltage, current, etc. 12 Product Type Commun ication Module Product information Description WiFi/LAN Kit-20 System operation information can be uploaded to monitoring platform through WiFi or LAN signals. 4G Kit-CN-G20 (Only for China) System operation information can be uploaded to monitoring platform through 4G signals. 1.3 Symbol Definition DANGER Indicates a high-level hazard that, if not avoided, will result in death or serious injury. WARNING Indicates a medium-level hazard that, if not avoided, could result in death or serious injury. CAUTION Indicates a low-level hazard that, if not avoided, could result in minor or moderate injury. NOTICE Highlights key information and supplements the texts. Or some skills and methods to solve product-related problems to save time. 13 2 Safety Precautions Please strictly follow these safety instructions in the user manual during the operation. WARNING The products are designed and tested strictly to comply with related safety rules. Follow all the safety instructions and cautions before any operations. Improper operation might cause personal injury or property damage as the products are electrical equipment. 2.1 General Safety NOTICE • The information in this document is subject to change due to product updates or other reasons. This document cannot replace the product labels or the safety precautions unless otherwise specified. All descriptions in the manual are for guidance only. • Before installations, read through the user manual to learn about the product and the precautions. • All operations should be performed by trained and knowledgeable technicians who are familiar with local standards and safety regulations. • Use insulating tools and wear personal protective equipment when operating the equipment to ensure personal safety. Wear anti-static gloves, wrist strips, and cloths when touching electronic devices to protect the equipment from damage. • Unauthorized dismantling or modification may damage the equipment, and the damage is not covered under the warranty. • Strictly follow the installation, operation, and configuration instructions in this manual or the user manual. The manufacturer shall not be liable for equipment damage or personal injury if you do not follow the instructions. For more warranty details, please visit https://www.goodwe.com/warrantyrelated.html. 2.2 Personal Requirements 14 NOTICE • Personnel who install or maintain the equipment must be strictly trained, learn about safety precautions and correct operations. • Only qualified professionals or trained personnel are allowed to install, operate, maintain, and replace the equipment or parts. 2.3 System Safety DANGER • Disconnect the upstream switches to power off the equipment before any electrical connections. Do not work with power on. Otherwise, an electric shock may occur. • Install a breaker at the voltage input side of the equipment to prevent personal injury or equipment damage caused by energized electrical work. • All operations such as transportation, storage, installation, use and maintenance shall comply with applicable laws, regulations, standards and specifications. • Perform electrical connections in compliance with local laws, regulations, standards and specifications, including cables and component specifications. • Use the connectors included in the package to connect cables. The manufacturer shall not be liable for the equipment damage if connectors of other models are used. • Ensure all cables are connected correctly, tightly, and securely. Inappropriate wiring may cause poor connection and damage the equipment. • The PE cables must be connected and secured properly. • To protect the equipment and components from damage during transportation, ensure that the transportation personnel are professionally trained. All operations during the transportation have to be recorded. The equipment shall be kept in balance to avoid falling down. • The equipment is heavy. Please equip the corresponding personnel according to its weight, so that the equipment does not exceed the maximum weight that the personnel can carry to avoid personnel injuries. • Keep the equipment stable to avoid dumping, which can result in equipment damage and personal injuries. 15 WARNING • Do not apply mechanical load to terminals, otherwise the terminals may be damaged. • If the cable bears too much tension, the connection may be poor. Reserve a certain length of the cable before connecting it to corresponding ports. • Tie the cables of the same type together, and place cables of different types at least 30mm apart. Do not place the cables entangled or crossed. • Place the cables at least 30mm away from the heating components or heat sources, otherwise the insulation layer of the cables may be aging or broken due to high temperature. 2.3.1 PV String Safety WARNING • Ensure the PV module frames and the bracket system are securely grounded. • Ensure the DC cables are connected tightly, securely and correctly. Inappropriate wiring may cause poor contacts or high impedances, and damage the inverter. • Measure the positive and negative terminals of the DC cable using a multimeter to avoid reverse polarity connection. Also, the voltage should be within the permissible range. • Measure the DC cable using the multimeter to avoid reverse polarity connection. Also, the voltage should be under the max DC input voltage. The manufacturer shall not be liable for the damage caused by reverse connection and extremely high voltage. • The PV strings cannot be grounded. Ensure the minimum insulation resistance of PV string to the ground meets the minimum insulation resistance requirements before connecting the PV string to the inverter (R=maximum input voltage (V)/ 30mA). • Do not connect the same PV string to multiple inverters at the same time. Otherwise, the inverters may be damaged. • PV modules used with inverters must comply with IEC 61730 Class A standard. 2.3.2 Inverter Safety 16 WARNING • The voltage and frequency at the connecting point should meet the on-grid requirements. • Additional protective devices like circuit breakers or fuses are recommended on the AC side. Specification of the protective device should be at least 1.25 times the maximum AC output current. • The arc fault alarms will be cleared automatically if the alarms are triggered less than 5 times in 24 hours. The inverter will shutdown for protection after the 5th electric arc fault. The inverter can operate normally after the fault is solved. • BACK-UP is not recommended if the PV system is not configured with batteries. Otherwise, there may be a risk of system power outage. 2.3.3 Battery Safety DANGER 17 • Keep Power Off before any operations to avoid danger of electric shock. Strictly follow all safety precautions outlined in this manual and safety labels on the equipment during the operation. • Do not disassemble, modify, or replace any part of the battery without official authorization from the manufacturer. Otherwise, it will cause electrical shock or damages to the equipment, which shall not be borne by the manufacturer. • Do not hit, pull, drag, squeeze or step on the equipment or put the battery into fire. Otherwise, the battery may explode. • Do not place the battery in a high temperature environment. Make sure that there is no direct sunlight and no heat source near the battery. When the ambient temperature exceeds 60 ℃, it will cause fire. • Do not use the battery if it is defective, broken, or damaged. Damaged battery may leak electrolyte. • Do not move the battery system while it is working. Contact after-sales service if the battery shall be replaced or added. • A short circuit in the battery may cause personal injury. The instantaneous high current caused by a short circuit can release a large amount of energy and may cause a fire. • To protect the equipment and components from damage during transportation, ensure that the transportation personnel are professionally trained. All operations during the transportation have to be recorded. The equipment shall be kept in balance to avoid falling down. • Battery The equipment is heavy. Please equip the corresponding personnel according to its weight, so that the equipment does not exceed the maximum weight that the personnel can carry to avoid personnel injuries. WARNING 18 • Factors such as temperature, humidity, weather conditions, etc. may limit the battery's current and affect its load. • Contact after-sale service immediately if the battery is not able to be started. Otherwise, the battery might be damaged permanently. • Inspect and maintain the battery regularly according to the maintenance requirements of the battery. • Ensure that the battery system is not damaged during transportation and storage. Keep the equipment stable to avoid dumping, which can result in equipment damage and personal injuries. Emergency Measures • Battery Electrolyte Leakage If the battery module leaks electrolyte, avoid contact with the leaking liquid or gas. The electrolyte is corrosive. It will cause skin irritation or chemical burn to the operator. Anyone contact the leaked substance accidentally has to act/respond as following: Breath in the leaked substance: Evacuate from the polluted area, and seek immediate medical assistance. Eye contact: Rinse your eyes for at least 15 minutes with clean water and seek immediate medical assistance. Skin contact: Thoroughly wash the touch area with soap and clean water, and seek immediate medical assistance. Ingestion: Induce vomiting, and seek immediate medical assistance. ○ ○ ○ ○ • Fire The battery may burn when the ambient temperature exceeds 150℃. Poisonous and hazardous gas may be released if the battery is on fire. In the event of a fire, please make sure that the carbon dioxide extinguisher or water extinguishing device is nearby. The fire cannot be put out by ABC dry powder extinguisher. Firefighters are required to wear full protective clothing and self-contained breathing apparatus. • Battery triggers fire protection For batteries with fire protection functions, perform the following operations after the fire protection function is triggered: Immediately cut off the main power switch to ensure that no current passes through the battery system. Conduct a preliminary inspection of the appearance of the battery to determine ○ ○ ○ ○ ○ 19 ○ ○ if there is any damage, deformation, leakage, or odor. Check the battery casing, connectors, and cables. Use temperature sensors to detect the temperature of the battery and its environment, ensuring there is no risk of overheating. Isolate and label damaged batteries, and handle them properly in accordance with local regulations. 2.3.4 Smart Meter Safety WARNING If the voltage of the power grid fluctuates, resulting in the voltage over 265V. In this case, long-term overvoltage operation may cause damage to the meter. It is recommended to add a fuse with a rated current of 0.5A on the voltage input side of the meter to protect it. 2.4 Safety Symbols and Certification Marks DANGER • All labels and warning marks should be visible after the installation. Do not cover, scrawl, or damage any label on the equipment. • The following descriptions are for reference only. Please refer to the actual labeling of the equipment. No. Symbol Descriptions 1 Potential risks exist. Wear proper PPE before any operations. 2 High voltage hazard. High voltage exists. Disconnect all incoming power and turn off the product before working on it. 3 High-temperature hazard. Do not touch the product under operation to avoid being burnt. 20 No. Symbol Descriptions 4 Operate the equipment properly to avoid explosion. 5 Batteries contain flammable materials, beware of fire. 6 The equipment contains corrosive electrolytes. In case of a leak in the equipment, avoid contacting the leaked liquid or gas. 7 Delayed discharge. Wait 5 minutes after power off until the components are completely discharged. 8 Install the equipment away from fire sources. 9 Keep away from children. 10 Do not pour with water. 11 Read through the user manual before any operations. 12 Wear PPE during installation, operation and maintaining. 13 Do not dispose of the System as household waste. Deal with it in compliance with local laws and regulations, or send it back to the manufacturer. 14 Grounding point. 21 No. Symbol Descriptions 15 Recycle regeneration mark. 16 CE Mark. 17 TUV mark. 18 RCM mark. 2.5 EU Declaration of Conformity 2.5.1 Equipment with Wireless Communication Modules The equipment with wireless communication modules sold in the European market meets the requirements of the following directives: • Radio Equipment Directive 2014/53/EU (RED) • Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS) • Waste Electrical and Electronic Equipment 2012/19/EU • Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH) 2.5.2 Equipment without Wireless Communication Modules (Except Battery) The equipment without wireless communication modules sold in the European market meets the requirements of the following directives: • Electromagnetic compatibility Directive 2014/30/EU (EMC) • Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD) • Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS) 22 • Waste Electrical and Electronic Equipment 2012/19/EU • Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH) 2.5.3 Battery The batteries sold in the European market meets the requirements of the following directives: • Electromagnetic compatibility Directive 2014/30/EU (EMC) • Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD) • Battery Directive 2006/66/EC and Amending Directive 2013/56/EU • Waste Electrical and Electronic Equipment 2012/19/EU • Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH) You can download the EU Declaration of Conformity from our official website at: https://en.goodwe.com. 23 3 System Introduction 3.1 System Overview Residential all-in-one energy storage system solution consists of inverter, battery system, smart meter, smart dongle, etc. In the PV system, solar energy can be converted to electric energy for household needs. The Software & Accessories in the system controls the electrical equipment by recognizing the overall power consumption situation. So that the power will be managed in a smart way, deciding whether the power is to be used by the loads, stored in batteries, or exported to the grid, etc. WARNING • If the system is in a high temperature or BMS current limiting situation, it may cause the battery charging power to be limited, which may lead to high system voltage triggering over-voltage protection. • In microgrid scenarios, the PV open-circuit voltage of the residential all-in-one energy storage system is recommended to be < 500V to avoid the system voltage becoming too high and triggering overvoltage protection under adverse conditions. • In microgrid scenarios, make sure that the overfrequency derating point of the on-grid inverter is the same as that of the residential all-in-one energy storage system. • If output power limitation is required for the on-grid inverter, please connect a separate device such as a smart meter or CT. • Make sure that the overfrequency derating curve of the on-grid inverter is set according to the following via SolarGo: Set the End Power to 0% Pn ○ ○ Set the response delay time to 0, and disable the hysteresis function • Due to product upgrades or other reasons, the document content may be updated irregularly. The matching relationship between inverters and Software & Accessories products can refer to: https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_Compatibilitylist-of-GoodWe-inverters-and-IoT-products-EN.pdf • For the detailed network configuration and wiring schemes for various scenarios, please refer to: 6.2.System Wiring Detail Diagram(Page 79). 24 When the energy storage system is in the off-grid state, the following loads can be used normally: Description for Off-Grid Load-Carrying Capacity of the Inverter Load Type ESA 3-10kW Rated Power of Single Generator Load (kVA) 0.3*Pn Total Rated Power of Generator Loads (kVA) 0.3*Pn Capacitive Load (kVA) 0.33*Pn Note: • Pn: Rated Output Power of the inverter. • For 2 or more units operating in parallel, the allowable total generator load nominal power = Single generator load nominal power * Number of parallel units * 80%. • Half-wave Load: Some older or non-EMC-compliant appliances( such as hair dryers or small heaters using half-wave rectification). General Scenarios 25 Product Type Energy Storage Inverter Model Discription GW3K-EHA-G20 GW3.6K-EHA-G20 GW5K-EHA-G20 GW6K-EHA-G20 GW8K-EHA-G20 GW9.999K-EHAG20 26 Product Type Model Discription • Compatible with GoodWe AC charging stations. GW10K-EHA-G20 • Generator control and generator-to-battery charging are only supported in the single inverter scenario. • The system supports a maximum of 6 inverters to form a parallel system, and enables on/offgrid hybrid parallel inverters with different power ranges. • In a parallel system, if the GW3K/3.6K/5K/6K models are mixed with the GW8K/9.999K/10K models, please set the GW8K/9.999K/10K model as the master inverter. • If it is necessary to connect a generator or build a parallel system, please use the GMK110 or GM330 smart meter; if the number of parallel inverters exceeds 2, please use the GM330 smart meter. • In a parallel system, each inverter must be equipped with a WiFi/LAN Kit-20. The software version requirements are V2.5 or above. • Requirements for parallel system: The ARM software version of the inverter is 02.99 and above. The DSP software version of the inverter is 02.2024 and above. The SolarGo software version is 6.8.0 and above. ○ ○ ○ Battery System GW5.1-BAT-D-G20 GW5.1-BAT-D-G21 GW8.3-BAT-D-G20 27 Product Type Model Discription GW8.3-BAT-D-G21 • Battery of different models can be mixed for use. It meets the requirements of matching use with different powers and capacities. • The maximum available power of a single cluster is 48kWh. • When GW5.1-BAT-D-G20 and GW8.3-BAT-D-G20 are mixed with GW5.1-BAT-D-G21 and GW8.3BAT-D-G21, the running ambient temperature requirements shall be based on those of GW5.1-BAT-D-G21 and GW8.3-BAT-D-G21. Built-in Smart Meter (shipped with inverter) • Built-in Smart Meter: Connect the inverter using the delivered CT. The default CT ratio is 120A : 40mA. ○ GMK110 (purchase from GoodWe) Smart Meter GM330 (purchase from GoodWe) When the built-in smart meter of the inverter fails to meet usage requirements, contact the dealers to purchase the GMK110 or GM330 smart meter. • GMK110: It is not supported to change the CT to other type, CT ratio is 120A: 40mA. • GM330: CTs are supported to be sourced either from GoodWe or purchased independently, the default CT ratio is nA : 5A. • If the inverter need to connect a generator, please use the GMK110 or GM330 smart meter. ○ 28 Product Type Model Discription WiFi/LAN Kit-20 • Applicable for single inverter scenario and parallel scenario. • Device parameters can be configured and device operating information can be viewed locally via Bluetooth signals, while system operating information can be uploaded to the monitoring platform via WiFi or LAN. • If the functions such as one-click upgrade and operation log export are required, please ensure that the software version of WiFi/LAN Kit-20 is V2.3 or above. Smart Dongle • Only applicable for single inverter scenario. 4G Kit-CN-G20 (Only for China) • Device parameters can be configured and device operation information can be viewed locally via Bluetooth signals, while system operation information can be uploaded to monitoring platform through 4G signals. • If the functions such as one-click upgrade and operation log export are required, please ensure that the software version of 4G Kit-CNG20 is 05 or above. Microgrid Scenarios When the grid-tied inverter is connected to the BACK- UP port of the hybrid inverter, it is a microgrid scenarios. 29 Product Type Model Discription GW3K-EHA-G20 GW3.6K-EHA-G20 Energy Storage Inverter GW5K-EHA-G20 GW6K-EHA-G20 GW8K-EHA-G20 • In microgrid scenarios, only one energy storage inverter is supported for use in the system. • In microgrid scenarios, connection to a generator is not supported. GW9.999K-EHA-G20 GW10K-EHA-G20 Battery System GW5.1-BAT-D-G20 GW5.1-BAT-D-G21 GW8.3-BAT-D-G20 30 Product Type Model Discription GW8.3-BAT-D-G21 • Battery of different models can be mixed for use. It meets the requirements of matching use with different powers and capacities. • The maximum available power of a single cluster is 48kWh. • When GW5.1-BAT-D-G20 and GW8.3-BAT-D-G20 are mixed with GW5.1-BAT-D-G21 and GW8.3BAT-D-G21, the running ambient temperature requirements shall be based on those of GW5.1BAT-D-G21 and GW8.3-BAT-D-G21. Built-in Smart Meter • Built-in Smart Meter: Connect the inverter using (shipped with the delivered CT. inverter) The default CT ratio is 120A : 40mA GMK110 (purchase When the built-in smart meter of the inverter from GoodWe) fails to meet usage requirements, contact the ○ ○ Smart Meter GM330 (purchase from GoodWe) dealers to purchase the GMK110 or GM330 smart meter. • GMK110: It is not supported to change the CT to other type, CT ratio is 120A: 40mA. • GM330: CTs are supported to be sourced either from GoodWe or purchased independently, CT turns ratio requirement: nA : 5A 31 Product Type Model Discription WiFi/LAN Kit-20 • Applicable for single inverter scenario and parallel scenario. • Device parameters can be configured and device operating information can be viewed locally via Bluetooth signals, while system operating information can be uploaded to the monitoring platform via WiFi or LAN. • If the functions such as one-click upgrade and operation log export are required, please ensure that the software version of WiFi/LAN Kit-20 is V2.3 or above. Smart Dongle • Only applicable for single inverter scenario. • Device parameters can be configured and device operation information can be viewed locally via Bluetooth signals, while system 4G Kit-CN-G20 (Only operation information can be uploaded to for China) monitoring platform through 4G signals. • If the functions such as one-click upgrade and operation log export are required, please ensure that the software version of 4G Kit-CNG20 is 05 or above. 32 Product Type Model Discription • It’s recommended to use on-grid inverter sold in GOODWE, and is supported to use the thirdparty on-grid inverter. • In microgrid scenarios, make sure that the nominal output power of the on-grid inverter is <= the nominal output power of the hybrid inverter. • When the microgrid system is grid connected, if power limit is required, make sure: The hybrid inverter should be set in the power limit interface of the SolarGo APP, and the on-grid inverter should be set according to the actual tools used. In order to ensure that the on-grid inverters can continue to generate power, the output power of the hybrid inverters must be adjusted in the microgrid mode interface of the SolarGo APP. ○ On-Grid Inverter - ○ Note: The output power control precision of different on-grid inverters varies. Please set the on-grid power limit control parameter value according to the actual situation. Coupled Scenario When the grid-tied inverter is connected to the ON- GRID port of the hybrid inverter, it is a coupled scenario. 33 Product Type Energy Storage Inverter Model Discription GW3K-EHA-G20 GW3.6K-EHA-G20 GW5K-EHA-G20 GW6K-EHA-G20 GW8K-EHA-G20 GW9.999K-EHAG20 34 Product Type Model Discription GW10K-EHA-G20 • Generator control and generator-to-battery charging are only supported in the single inverter scenario. • The system supports a maximum of 6 inverters to form a parallel system, and enables on/offgrid hybrid parallel inverters with different power ranges. • In a parallel system, if the GW3K/3.6K/5K/6K models are mixed with the GW8K/9.999K/10K models, please set the GW8K/9.999K/10K model as the master inverter. • If it is necessary to connect a generator or build a parallel system, please use the GMK110 or GM330 smart meter; if the number of parallel inverters exceeds 2, please use the GM330 smart meter. • In a parallel system, each inverter must be equipped with a WiFi/LAN Kit-20. The software version requirements are V2.5 or above. • The following version requirements must be met when operating in parallel for grid connection: The ARM software version of the inverter is 02.99 and above. The DSP software version of the inverter is 02.2024 and above. The SolarGo software version is 6.8.0 and above. ○ ○ ○ Battery System GW5.1-BAT-D-G20 GW5.1-BAT-D-G21 GW8.3-BAT-D-G20 35 Product Type Model Discription GW8.3-BAT-D-G21 • Battery of different models can be mixed for use. It meets the requirements of matching use with different powers and capacities. • The maximum available power of a single cluster is 48kWh. • When GW5.1-BAT-D-G20 and GW8.3-BAT-D-G20 are mixed with GW5.1-BAT-D-G21 and GW8.3BAT-D-G21, the running ambient temperature requirements shall be based on those of GW5.1-BAT-D-G21 and GW8.3-BAT-D-G21. Built-in Smart Meter (shipped with inverter) • Built-in Smart Meter: Connect the inverter using the delivered CT. The default CT ratio is 120A : 40mA ○ GMK110 (purchase from GoodWe) Smart Meter GM330 (purchase from GoodWe) When the built-in smart meter of the inverter fails to meet usage requirements, contact the dealers to purchase the GMK110 or GM330 smart meter. • GMK110: It is not supported to change the CT to other type, the default CT ratio is 120A : 40mA. • GM330: CTs are supported to be sourced either from GoodWe or purchased independently, the default CT ratio is nA : 5A. • If the inverter need to connect a generator, please use the GMK110 or GM330 smart meter. ○ 36 Product Type Model Discription WiFi/LAN Kit-20 • Applicable for single inverter scenario and parallel scenario. • Device parameters can be configured and device operating information can be viewed locally via Bluetooth signals, while system operating information can be uploaded to the monitoring platform via WiFi or LAN. • If the functions such as one-click upgrade and operation log export are required, please ensure that the software version of WiFi/LAN Kit-20 is V2.3 or above. Smart Dongle • Only applicable for single inverter scenario. 4G Kit-CN-G20 (Only for China) • Device parameters can be configured and device operation information can be viewed locally via Bluetooth signals, while system operation information can be uploaded to monitoring platform through 4G signals. • If the functions such as one-click upgrade and operation log export are required, please ensure that the software version of 4G Kit-CNG20 is 05 or above. 37 Product Type On-Grid Inverter Model - Discription • It’s recommended to use on-grid inverter sold in GOODWE, and is supported to use the thirdparty on-grid inverter. • In AC coupled scenarios, make sure that the nominal output power of the on-grid inverter is <= the nominal output power of the hybrid inverter. • When the coupled system is in on-grid mode, If power limitation control is required, the hybrid inverter should be set in the export power limit interface of the SolarGo APP, and the on-grid inverter should be set according to the actual tools used. Note: The output power control precision of different on-grid inverters varies. Please set the on-grid power limit control parameter value according to the actual situation. 3.2 Product Overview 3.2.1 Residential All-In-One Energy Storage System (Single Phase) Residential All-In-One Energy Storage System (Single Phase): Residential All-In-One Energy Storage System (Single Phase), which integrates batteries and inverters through modular design and adopts a blind plug stacking connection method. 38 Floor-mounted installation Ground installation supports stacking up to 6 batteries. Wall-mounted Installation The maximum quantity of stacked units for wall-mounted installation is as follows: 39 Inverter: Inverters control and optimize the power in PV systems through an integrated energy management system. The electricity generated in the photovoltaic system can be used for loads, stored in batteries, output to the power grid, etc. No. Components / Silk Screen Printing Description 1 Indicator Indicating the working status of the inverter and the SOC of the battery. 2 Heat Sink Uses for heat dissipation of the inverter. 3 Connector Power and Communication Ports for Inverter-Battery Connection. 40 Components / Silk Screen Printing Description 4 Smart Dongle Port • Connecting the Smart Dongle, such as WiFi/LAN Kit-20 or 4G Kit-CN-G20 and select the type of the Smart Dongle according to actual needs. • Supporting connection with USB flash drive for local software upgrading. 5 Lifting Rod Mounting Hole (Optional) Used to install lifting rod. Used when handling inverters. 6 DC Switch Controlling the connection or disconnection of DC input. 7 ON-GRID Port Connecting the AC cables and connect the inverter to the utility grid. 8 BACK-UP Port Connecting the AC cables and connect important loads or on-grid inverter. 9 Battery Mounting Holes Secure the inverter and battery 10 Communication Port Connecting communication cables for load control, CT, RS485, remote shutdown/rapid shutdown, DRED (Australia) /RCR (Europe) etc. No. Used to connect the PV module DC input cables. PV Input Terminal Quantity: 11 PV Input Terminal 12 Ventilation valve • GW3K-EHA-G20, GW3.6K-EHA-G20, GW5K-EHA-G20, GW6K-EHA-G20 : 2 • GW8K-EHA-G20, GW9.999K, EHA-G20, GW10K-EHAG20: 4 - 41 No. Components / Silk Screen Printing Description 13 Protective Grounding Terminal Connects the grounding cable of the inverter. Batteries: The battery system stores and releases electricity based on the requirements of a PV energy storage system. The input and output ports of the energy storage system are both high-voltage direct current. No. Component Description 1 Connector Power and Communication Ports for Battery-Battery and Inverter-Battery Connection. 2 Anti-tip Bracket Fixing Hole Used for securing the battery to the wall. 42 No. Component Description • Indicator STS work state. • Battery black start function: When there is no PV power generation in the photovoltaic system and the grid is abnormal, if the inverter cannot operate normally, the battery black start function can be used to force the battery to discharge and start the inverter. The inverter can then enter off-grid mode and operate, with the battery supplying power to the load. • Battery Power-Off Function: Press and hold the multifunction button for more than 5 seconds to power off the battery system. 3 Multi-function Button Indicator Light 4 Battery Isolator Switch Battery Power Input/Output Switch 5 Battery Mounting Holes Used for securing two batteries together. 6 Heat Sink Battery Heating 7 Battery Lifting Hole Used for installing batteries. When stacking more than three batteries, a hoisting tool must be used for hoisting and installation. 8 Battery/Inverte r Mounting Holes Battery/Inverter Mounting Holes 9 Lifting Rod Mounting Hole (Optional) Used to install lifting rod. Used when handling inverters. 3.2.2 Smart Meter The smart meter can measure and monitor the data in the photovoltaic energy storage system, such as voltage, current, frequency, power factor, and power, etc. 43 GMK110 No. Model 1 GMK110 2 GM330 CT GM330 Applicable scenarios It is not supported to change the CT to other type, CT ratio: 120A: 40mA Supports purchasing from GOODWE or third-party, CT ratio requirement: nA: 5A • nA: CT Primary side input current, the range of n is 200-5000 • 5A: CT Secondary side output voltage. 3.2.3 Smart Dongle The smart dongle can transmit various power generation data to the remote monitoring platform, in real time, and can communicate with the SolarGo App to complete the near-end equipment commissioning. 44 No. Model Signal Applicable scenarios 1 WiFi/LAN Kit-20 WiFi, LAN, Bluetooth Single inverter scenario, multi inverter scenario 2 4G Kit- CN-G20 (Only for China) 4G、Bluetooth Single inverter scenario 3.3 Supported Grid Types 45 3.4 System Working Mode Self-use Mode • Self-use mode is the basic working mode of the system. • The power generated by the PV system supply the loads in priority; the excess power will charge the batteries, and then the remaining power will be sold to the utility grid. When the power generated in the PV system is insufficient, the battery will supply the loads in priority. If the battery power is insufficient, the load will be powered by the utility grid. BACK-UP Mode • The BACK-UP mode is mainly applied to the scenario where the grid is unstable. • When the grid is disconnected, the inverter turns to off-grid mode and the battery will supply power to the BACK-UP loads; when the grid is restored, the inverter switches to on-grid mode. • To ensure that the battery SOC is sufficient to maintain normal operation of the 46 system when it is off grid, the battery will be charged to the backup power SOC using PV or grid power during on-grid operation. If you need to purchase electricity from the power grid to charge the battery, please confirm compliance with local power grid laws and regulations. 47 TOU Mode It is recommended to use TOU mode in scenarios when the peak-valley electricity price varies a lot. Select TOU mode only when it meets the local laws and regulations. For example, set the battery to charge mode during Valley period to charge battery with grid power. And set the battery to discharge mode during Peak period to power the load with the battery. 48 49 Delayed Charging Mode • Suitable for areas with on-grid power output restrictions. • Setting a peak power limit allows the PV power that exceeds the on-grid limit to be used to charge the battery; or setting a PV charging time period, during which the PV power is utilized to charge the battery. 50 51 52 Demand Management Model • It is mainly applicable to industrial and commercial scenarios. • When the total power consumption of the load exceeds the power quota within a short period of time, battery discharge can be used to reduce the amount of power consumption exceeding the quota. • When the battery SOC is below the reserved SOC for demand management, the system buys power from the grid based on the time period, load power usage, and the peak power buy limit. 53 Off-grid Mode NOTICE Please do not operate the energy storage system in pure off-grid mode for long periods of time, otherwise there is a risk of over-discharge when the battery cannot be charged in low temperature or low light conditions. Do not operate in pure off-grid mode when the inverter is not connected to the battery system. When the power grid fails, the inverter switches to off-grid mode. • During the day, PV power generation is prioritized for supplying power to loads, and excess power is used to charge batteries. • Nighttime battery discharge powers the load to ensure uninterrupted power supply to the backup load. 54 3.5 Features Notice Please refer to the actual product configuration for specific functional features. AFCI The inverter is integrated with an AFCI (Arc-Fault Circuit Interrupter) protection device used to detect arc faults and rapidly disconnect the circuit to avoid electrical fires. Reason to occur electric arcs: • Damaged connectors in PV or battery system. • Wrong connected or broken cables. 55 • Aging of connectors and cables. Troubleshooting: 1. When the inverter detects an arc, the type of fault can be viewed through the display screen of the inverter or App. 2. The alarm can be cleared automatically in 5 minutes if the inverter triggers a fault for less than 5 times within 24 hours. The inverter will shutdown for protection after the 5th electric arc fault. The inverter can operate normally after the fault is solved. For more details, refer to the SolarGo APP User Manual. Model GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 GW8K-EHAG20 GW9.999KEHA-G20 GW10K-EHAG20 Label Description AFCI: F-I-AFPE-1-21 F: Full coverage I: Integrated AFPE: Detection and interruption capability provided 1: 1 monitored string per input port 2: 2 input ports per channel 1: 1 monitored channel AFCI: F-I-AFPE-12/2-2 F: Full coverage I: Integrated AFPE: Detection and interruption capability provided 1: 1 monitored string per input port 2/2: 2/2 input ports per channel(AFD1: 2: AFD2: 1) 2: 2 monitored channels Load Control The inverter has a dry contact controlling port, which supports connecting additional contactors to enable/disable the load. It supports domestic loads, heat pumps, etc. Load control methods are as follows: • Time control: Set the time to turn the load on or off, and the load will automatically turn on or off within the set time period. 56 • Switch control: When the control mode is set to ON, the load turns on; when set to OFF, the load turns off. • BACK-UP load control: The inverter is equipped with a built-in relay dry contact control port, which enables load on/off control via the relay. In off-grid mode, if the BACK-UP terminal is detected to be overloaded and the battery SOC is lower than the set value for battery off-grid protection, the load connected to the relay port can be turned off. Rapid Shutdown (RSD) In the rapid shutdown system, the receiver and transmitter work together to shutdown the PV system rapidly. The receiver maintains the modules working by continuously receiving a heartbeat signal from a transmitter. The transmitter can be external or integrated into the inverter. In case of an emergency, you can enable the external initiator to shut down the transmitter, by which the RSD will stop working and the modules be shut down. • External Transmitter Transmitter Model: GTP-F2L-20, GTP-F2M-20 https://admin.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_RSD-20Transmitter_User-Manual-EN.pdf" Receiver Model: GR-B1F-20, GR-B2F-20 https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_RSD-20_QuickInstallation-Guide-POLY.pdf • Integrated Transmitter External initiator: external Switch ○ ○ ○ ○ Receiver Model: GR-B1F-20, GR-B2F-20 https://en.goodwe.com/Ftp/EN/Downloads/User%20Manual/GW_RSD-20_QuickInstallation-Guide-POLY.pdf 57 4 Check and Storage 4.1 Check Before Receiving Check the following items before accept. 1. Check the outer packing box for damage, such as holes, cracks, deformation, and other signs of equipment damage. Do not unpack the package and contact the supplier as soon as possible if any damage is found. 2. Check the product model. If the product model is not what you requested, do not unpack the product and contact the supplier. 4.2 Deliverables WARNING Check the deliverables for correct model, complete contents, and intact appearance. Contact the supplier as soon as possible if any damage is found. 4.2.1 Inverter Deliverables Component Description Component Description Inverter x 1 Decorative cover x 1 Left decorative cover x1 Right decorative cover x1 58 Component or Description Component Description AC terminal x 2 Handle x 2 OT grounding terminal x 1 6PIN Communication terminal x 2 2PIN Communication terminal x 2 PIN terminal x 16 CT connection cable x1 CT x 1 Battery Base x 1 Adjustable feet x 4 Anti-tip bracket x 4 M5*16 bolt x 9 59 Component Description Component M5*60 Expansion bolt x 4 or PV terminal and PV terminal tamperproof cover x N GW3K-EHA-G20, GW3.6K-EHA-G20, GW5K-EHA-G20, GW6K-EHA-G20 : 4 GW8K-EHA-G20, GW9.999K-EHA-G20, GW10K-EHA-G20 : 8 Note: There is no PV terminal tamperproof cover in the China region. Description Punch-marked paper x 2 PV terminal unlocking tool x 1 N: China Region x 0; Other Regions x 1 or Smart dongle x1 Manual switch (only for Australia) x 1 Note: Only for single inverter scenario. Documents x 1 4.2.2 Batteries Deliverables Component Description Component Battery x1 Description M5*16 bolts x 2 60 Component Description Component Description Silicone cap x 2 - - Component Description Hanger installation (optional) Component Description M10 Expansion bolts x 6 Bracket x 2 M10 bolts x 4 - - 4.2.3 Smart Meter Deliverables 4.2.3.1 GMK110 Compone nt Description Compone nt Description RS485 communication terminals x 1 Smart Meter and CT x 1 61 Compone nt Compone nt Description Description Voltage input side terminal x 1 PIN terminal x 4 Screw driver x 1 Documents x 1 4.2.3.2 GM330 Component Description Component Description Smart Meter x1 2 PIN terminal x1 PIN terminal x 6 7 PIN terminal x1 Screw driver x 1 Documents x 1 4.3 Storage • If the inverter has been stored for more than two years or has not been in operation for more than six months after installation, it is recommended to be inspected and tested by professionals before being put into use. • To ensure good electrical performance of the internal electronic components of the inverter, it is recommended to power it on every 6 months during storage. If it has not been powered on for more than 6 months, it is recommended to be inspected and tested by professionals before being put into use. • In order to protect the performance and service life of the battery, it is recommended to avoid unused storage for a long period of time. Prolonged storage may cause deep discharging of the battery, resulting in irreversible 62 chemical loss, leading to capacity degradation or even complete failure, timely use is recommended. If the battery needs to be stored for a long period of time, please maintain it according to the following requirements: Notice [1] The storage time starts from the SN date on the outer packaging of the battery and requires charging and discharging maintenance after the storage cycle is exceeded. (Battery maintenance time = SN date + charging/discharging maintenance cycle). For SN date, refer to14.4.Battery SN Code Meaning(Page 376) [2] After passing the charging/discharging maintenance, if there is a Maintaining Label attached to the outer box, then please update the maintenance information on the Maintaining Label. if there is no Maintaining Label, please record the maintenance time and SOC of the batteries and keep the data to facilitate the keeping of maintenance records. Battery type Initial SOC Range for Battery Storage Storage Temper ature (℃) Charge and Discharge Maintaining [1] Period Battery Maintenance [2] Method 0~35℃ -20~35℃, 12months 35~45℃, 6 months Contact the dealer or the after-sales service for maintenance method. GW5.1-BAT-D-G20 GW8.3-BAT-D-G20 GW5.1-BAT-D-G21 GW8.3-BAT-D-G21 35~45% Packing requirements: Do not unpack the outer package or throw the desiccant away. Environment Requirements: 1. Place the equipment in a cool place where away from direct sunlight. 2. Store the equipment in a clean place. Make sure the temperature and humidity are appropriate and no condensation. Do not install the equipment if the ports or terminals are condensed. Battery storage temperature range: 5%-95% 63 3. Keep the equipment away from flammable, explosive, and corrosive matters. Stacking requirements: 1. The height and direction of the stacking inverter should follow the instructions on the packing box. 2. The inverter must be stacked with caution to prevent them from falling. 64 5 Installation DANGER Install and connect the equipment with the deliverables included in the package. Otherwise, the manufacturer shall not be liable for the damage. 5.1 Installation Requirements 5.1.1 Installation Environment Requirements 1. Do not install the equipment in a place near flammable, explosive, or corrosive materials. 2. The temperature and humidity at the installation site should be kept within the appropriate range. 3. Keep away from children. 4. High temperatures may exist on the surface of the equipment during operation to prevent burns. 5. Install the equipment in a sheltered place to avoid direct sunlight, rain, and snow. Build a sunshade if it is needed. 6. The place to install the equipment shall be well-ventilated for heat radiation and large enough for operations. 7. Check the protection rating of the equipment and ensure that the installation environment meets the requirements. The inverter, battery system, and smart dongle can be installed both indoors and outdoors, but the smart meter can only be installed indoors. 8. Install the equipment at a height that is convenient for operation and maintenance, electrical connections, and checking indicators and labels. 9. The altitude to install the inverter shall be lower than the maximum working altitude of the system. 10. Consult the manufacturer before installing the equipment outdoors in salt affected areas. A salt-affected area refers to the region within 500 meters offshore, and will be related to the sea wind, precipitation and topography. 11. This inverter has not been tested and verified in accordance with the AS/NZS 4777.2:2020 standard for combinations of multiple inverters and/or multi-phase inverter combinations. Therefore, such combination schemes should not be used. 12. Install the equipment away from electromagnetic interference. If there is any radio or wireless communication equipment below 30MHz near the equipment, you have 65 to: • Inverter: add a multi-turn winding ferrite core at the AC output cable of the inverter, or add a low-pass EMI filter. Or the distance between the inverter and the wireless EMI equipment should be more than 30m. • Other equipment: the distance between the equipment and the wireless EMI equipment should be more than 30m. NOTICE • Inverter Operating Temperature Range: -35℃-60℃. • GW5.1-BAT-D-G20, GW8.3-BAT-D-G20: Charging temperature range: -18℃-55°C; Discharging temperature range: -20℃-55°C. If installed in an environment below -18℃, the battery will not be able to continue charging to restore energy after being discharged, resulting in undervoltage protection. • GW5.1-BAT-D-G21, GW8.3-BAT-D-G21: Charging temperature range: 2℃-55°C; Discharging temperature range: -20℃-55°C. If installed in an environment below 2℃, the battery will not be able to continue charging to restore energy after being discharged, resulting in undervoltage protection. 5.1.2 Installation Space Requirements 66 Reserve enough space for operations and heat dissipation when installing the system. • When using CAT 7E communication cables among inverters, the maximum distance can reach 10 meters, while using CAT 5E or CAT 6E communication cables, the maximum distance can reach 5 meters. The length of the communication cable should not exceed 10 meters; otherwise, it may cause communication abnormality. • For the installation of the CT, a shielded network cable of CAT 5E or higher grade must be used, and the cable length should not exceed 30 meters. • For the RS485 twisted-pair shielded cable used for communication between the inverter and the smart meter, the cable length should not exceed 100 meters. 67 5.1.3 Tool Requirements NOTICE The following tools are recommended when installing the equipment. Use other auxiliary tools on site if necessary. Installation Tools Tool Type Description Tool Type Description Diagonal pliers RJ45 crimping tool Wire stripper Level ruler Adjustable wrench PV connector tool PV-CZM-61100 Impact drill (drill bits Φ12mm) Torque wrench M4, M5, M6, M10 Rubber hammer Socket wrench set Marker Multimeter Range<=600V Heat shrink tube Heat gun 68 Tool Type Description Tool Type Cable tie (Only for China) PV Unlocking tool x1 Description Vacuum cleaner - - Personal Protective Equipment Tool Type Description Tool Type Description Insulating gloves, protective gloves Dust mask Goggles Safety shoes 5.2 Equipment Handling 69 CAUTION • Operations such as transportation, turnover, installation and so on must meet the requirements of the laws and regulations of the country or region where inverters are installed. • Move the equipment to the site before installation. Follow the instructions below to avoid personal injury or equipment damage. 1. Consider the weight of the equipment before moving it. Assign enough personnel to move the equipment to avoid personal injury. 2. Wear safety gloves to avoid personal injury. 3. Keep balance to avoid falling down when moving the equipment. 4. The battery system can be transported to the installation site by crane. 5. When moving equipment using a hoisting method, please use flexible slings or straps. The load-bearing capacity of a single strap must meet the following requirements: GW5.1-BAT-D-G20, GW5.1-BAT-D-G21≥180KG ○ ○ GW8.3-BAT-D-G20, GW8.3-BAT-D-G21 ≥240KG 5.3 Equipment Installation 70 CAUTION • Avoid the water pipes and cables buried in the wall when drilling holes to avoid risks. • Wear goggles and a dust mask to prevent the dust from being inhaled or contacting eyes when drilling holes. • Install the inverter above the battery, do not install the battery above the inverter. • Ensure that the battery system is installed vertically and securely. Ensure that the holes of the upper and lower layers are aligned when placing the battery base, battery, and inverter. The anti-tip bracket should be vertically attached to the ground, wall, or battery system surface. • Cover the equipment with a cardboard to prevent foreign matters when drilling holes. Otherwise, the system may be damaged. Notice • The battery must be installed on the base, which can be installed on the ground or on a hanging bracket. • When using the base for installation, up to six batteries can be stacked. • The maximum stacking quantity when using a mounting bracket is specified as follows: Identical Energy Stack: GW5.1-BAT-D-G20, GW5.1- BAT-D-G21: Maximum of 3 pieces. ○ ■ ■ GW8.3-BAT-D-G20, GW8.3- BAT-D-G21: Maximum of 2 pieces. Energy Overlap: When GW5.1-BAT-D-G20, GW5.1-BAT-D-G21 are stacked, GW8.3-BAT-D-G20, and GW8.3-BAT-D-G21, a maximum of two units can be stacked. • The base, bracket, and top battery must be secured to the wall with anti-tip brackets. • When marking the drilling positions for the hanger installation, one person should hold the base firmly, while the other uses a marker pen to mark the drilling positions. • When installing the battery and inverter, remove the protective cover from the blind mating connector before stacking. ○ ■ 71 Installing the brackets Step 1: Install the base on the hanger. Step 2: Hang the hanger close to the wall. Ensure that the hanger is securely in place and check the level bubble in the center of the base. Step 3: After adjusting the position and level of the hanger, use a marker pen to mark the drilling positions. Once marking is done, remove the hanger. (A: PACK fixing holes; B: Bracket fixing holes.) Step 4: Drill holes and install expansion screws. Step 5 Secure the mounting plate using the expansion bolts. 1. Drill holes with the impact drill. 2. Clean the holes. 3. Use a rubber mallet to install the expansion screws into the holes. 4. Use an Allen wrench to tighten the nut clockwise to expand the screw. 5. Remove the nut by turning it counterclockwise. 6. Use a torque screwdriver to secure the anti-tip bracket to the wall. Installation base Step 1: Install the adjustable feet on the bottom of the base and secure the anti-tip bracket to the base. Step 2: Place the base 35-55mm away from the wall, keeping it parallel to the wall. Observe the level bubble in the center of the base. If the bubble is not centered, use the adjustable feet to level the base. Step 3: After adjusting the position and level of the base, use the hole marking paper 72 to mark the hole positions. Once the marking is complete, remove the base. (A: PACK fixing holes; B: Bracket fixing holes.) Step 4: Use an impact drill to drill holes and clean them. Step 5: Use a Phillips screwdriver to secure the anti-tip bracket to the wall. a: Fixed to the base; b: Fixed to the wall. Installing the Battery and the Inverter Step 1: Install the handle (optional), remove the protective cover from the battery blind mating connector, and stack the batteries on the base. If installing more than three battery, please use lifting equipment. Step 2: Tighten the screws securing the battery to the base or between batteries.If you need to install multiple batteries, repeat step 1 and step 2 to complete the installation of all batteries. Do not stack more than 6 batteries in a single group. Step 3: The base, bracket, and top battery must be secured to the wall with anti-tip brackets. Step 4: Remove the protective cover from the blind mating connector at the bottom of the inverter. Step 5: Lift the inverter and stack it on top of the battery, then tighten the screws between the inverter and the battery. a: Fixed to PACK; b: Fixed to the wall. 73 5.4 Installing the Smart Meter WARNING In areas at risk of lightning, if the meter cable exceeds 10m and the cables are not wired with grounded metal conduits, you are recommended to use an external lightning protection device. GMK110 GM330 74 75 6 System Wirings DANGER • The erection, routing, and connection of cables must be in compliance with local laws and regulations. • Perform electrical connections in compliance with local laws and regulations, including operations, cables, and component specifications. • Disconnect the DC switches and the AC output switches to power off the equipment before any electrical connections. Do not work with power on. Otherwise, an electric shock may occur. • Tie the same type cables together, and place them separately from cables of different types. Do not place the cables entangled or crossed. • If the cable bears too much tension, the connection may be poor. Reserve a certain length of the cable before connecting it to the inverter cable port. • Make sure that the cable conductor is in full contact with the terminal and the cable insulation part is not crimped with the terminal when crimping the terminal. Otherwise, the device may not be able to work properly, or the connection may be unreliable during working, which may cause terminal block damage, etc.. NOTICE • Wear personal protective equipment like safety shoes, safety gloves, and insulating gloves during electrical connections. • All electrical connections should be performed by qualified professionals. • Cable colors in this document are for reference only. The cable specifications shall meet local laws and regulations. 6.1 System Wiring Electrical Block Diagram 76 NOTICE • N and PE wiring of ON-GRID and BACK-UP ports of the inverter are different according to the regulation requirements of different regions. Refer to the specific requirements of local regulations. • The inverter has a built-in electric meter that can be directly connected to a CT for use. The CT network cable included in the box is 10 meters long. If you need a longer cable, you can use a CAT5E or higher shielded network cable to extend it to 30 meters. • When the length of the connection between the CT and the inverter exceeds 30 m, accuracy will decrease. If high accuracy is required, an external smart meter can be connected. • The inverter features built-in relays for the ON_GRID and BACK_UP AC ports. When the inverter is in off-grid mode, the built-in ON_GRID state relay is disconnected; when the inverter is in on-grid operation mode, the built-in ONGRID relay is connected. • When the inverter is powered on, the BACK-UP AC port is energized. Power off the inverter first if maintenance is required on the BACK-UP loads. Otherwise, it may cause electric shock. N and PE cables are connected together in the Main Panel. NOTICE • To maintain neutral integrity, the neutral lines on the grid-connected side and the off-grid side must be connected together, otherwise the off-grid function will not work properly. • The figure below shows a schematic diagram of the power grid systems in Australia, New Zealand, and other regions: 77 N and PE cables are separately wired in the Main Panel. NOTICE • Ensure that the grounding of BACK-UP is correctly tightened. Otherwise, the BACK-UP function may be abnormal in case of grid failure. • The following diagram is applicable to areas except Australia or New Zealand. 78 6.2 Detailed System Wiring Diagram When all loads in a photovoltaic system are unable to consume the electricity generated by the system, the remaining electricity is fed into the grid. At this point, a smart meter or a CT can be used in conjunction to monitor the system's power generation and control the amount of electricity fed into the grid. • Connecting a smart meter enables the functions of output power limitation and load monitoring. • After connecting a smart meter, please enable the on-grid power limitation function via the SolarGo App. In the single-unit system wiring diagram, only some models of equipment are used for wiring demonstration. Please perform wiring according to the actual equipment in use and refer to the corresponding wiring guide chapter. 79 Notice • When implementing load monitoring functions in microgrids and coupled scenarios, a dual-meter network must be used. Electric meter 1 or built-in electric meter is used for system output power limitation. Electricity meter 2 is used for load monitoring. ○ ○ By integrating the data from Meter 1 and Meter 2, the monitoring platform can realize real-time monitoring of the load's power consumption. • In microgrid scenarios, only one energy storage inverter is supported for use in the system. • If output power limitation is required for the grid-connected inverter, please connect a separate device such as a smart meter or CT. • Microgrid scenarios and coupled scenarios are paired with dual electricity meters, and the wiring methods for the meters are consistent. • When not using integrated smart meter, do not connect the CT port of the inverter. • Manual conversion switches are optional. Please choose whether to install them based on the actual usage scenario. If you have your own ATS or STS switch, this switch must have an interlock function. ○ Dual electricity meter pairing scenario Smart Meter 1 (Grid end) Smart Meter 2 (AC side of on-grid Inverter) Integrated Meter (Single inverter) GMK110 Integrated Meter (Single inverter) GM330 GMK110 GMK110 GM330 GM330 GMK110 GM330 GM330 GMK110 6.2.1 Detailed System Wiring Diagram for Single Inverter 80 General Scenario With integrated smart meter scenarios Connection to a generator is not supported. With GMK110 Smart Meter 81 With GM330 Smart Meter 82 Microgrid Scenario • In microgrid scenarios, connection to a generator is not supported. • Manual conversion switches are optional. Please choose whether to install them based on the actual usage scenario. Integrated Smart Meter+GM330 Smart Meter Networking Diagram 83 GMK110+GMK110 Networking Diagram 84 Microgrid Scenario. On-grid Inverter Power Limitation Networking Diagram If output power limitation is required for the on-grid inverter, please connect a separate device such as a smart meter or CT. 85 Coupled Scenario. Dual Smart Meter Networking Diagram • Manual conversion switches are optional. Please choose whether to install them based on the actual usage scenario. • Connection to a generator is not supported. Integrated Smart Meter+GMK110 Smart Meter Networking Diagram 86 GM330+GM330 Networking Diagram 87 Coupled Scenario. On-grid Inverter Power Limitation Networking Diagram In the coupled scenario, if output power limitation is required for the on-grid inverter, please connect a separate device such as a smart meter or CT. 6.2.2 Detailed System Wiring Diagram for Parallel System 88 NOTICE • If devices such as DRED equipment, RCR equipment, remote shutdown equipment, NS Protection, and SG Ready heat pumps need to be connected in the system, please connect them to the main inverter. • Remote shutdown/NS Protection Function: please connect the communication cable to the master inverter. Rapid shutdown function: please connect the communication cable to each inverter respectively. If the rapid shutdown function and remote shutdown/NS protection function need to be used at the same time, please contact the after-sales service center. • The GM330 Smart Meter is standard for 2 or more inverters are paralleled. • In a parallel operation system, if you need to disconnect the circuit breaker of any port on a slave inverter, please disconnect the circuit breakers of other ports on this inverter simultaneously; otherwise, it may cause abnormal system operation. • In a parallel system, connection to a generator is not supported. • The following diagram mainly introduces parallel connections. For other port connections, refer to the single system. In parallel scenarios, the inverter connected to the smart meter isconsidered as the master inverter, while all the others are slavery inverters.The master inverter must be set as the master unit through the parallel system settings in the “SolarGo App”. For specific settings, please refer to 9.2.6."Setting Up .the RS485 Parallel System"(Page 152) General Scenarios With GMK110 scenarios 89 With GM330 scenarios 90 Coupled Scenarios GM330+GM330 Networking Diagram 91 In the coupled system scenarios, the paralleling wiring method for the configuration with GMK110 can refer to the scenario of configuring GMK110 in the general paralleling scenario; the wiring method for the grid-connected inverter can refer to the single-unit coupling scenario for wiring. 6.3 Preparing Materials WARNING 92 • Do not connect loads between the inverter and the AC switch directly connected to the inverter. • Install one AC output circuit breaker for each inverter. Multiple inverters cannot share one AC circuit breaker. • An AC circuit breaker shall be installed on the AC side to make sure that the inverter can safely disconnect the grid when an exception happens. Select the appropriate AC circuit breaker in compliance with local laws and regulations. • When the inverter is powered on, the BACK-UP AC port is charged. Power off the inverter first if maintenance is required on the BACK-UP loads. Otherwise, it may cause electric shock. • For cables used in the same system, it is recommended that the conductor material, cross sectional area, length, etc. of the cables should be consistent. The AC cable for BACK-UP port of each inverter ○ ○ The AC cable for ON-GRID port of each inverter • In single inverter scenario, the inverter supports connection to a generator via an ATS switch, enabling switching between grid and generator power supply. The ATS switch is connected to the power grid by default. 6.3.1 Preparing Breakers No. Circuit breaker Recommended specifications Acquisitio n method Comment Prepared by customers When selecting a circuit breaker, you can also choose one that meets local installation regulations based on the actual working current. The partial power scenario are recommended as follows: • Nominal Voltage>=230Vac 1 ON-GRID circuit breaker BACK-UP circuit breaker • The rated current requirements are as follows: GW3K-EHA-G20 : 20A ○ ○ GW3.6K-EHA-G20 : 20A ○ GW5K-EHA-G20 : 32A ○ GW6K-EHA-G20 : 40A ○ GW8K-EHA-G20 : 50A ○ GW9.999K-EHA-G20 : 63A 93 No. Circuit breaker Recommended specifications ○ Acquisitio n method Comment Prepared by customers Single inverter only GW10K-EHA-G20 : 63A The whole-house backup power scenario are recommended as follows: • Nominal Voltage≥230Vac • The rated current requirements are as follows: GW3K-EHA-G20 : 40A ○ ○ GW3.6K-EHA-G20 : 40A ○ GW5K-EHA-G20 : 63A ○ GW6K-EHA-G20 : 63A ○ GW8K-EHA-G20 : 63A ○ GW9.999K-EHA-G20 : 63A ○ GW10K-EHA-G20 : 63A Note: If the inverter's BACKUP port is not used, the ONGRID circuit breaker can be selected according to the maximum grid-connected current. 2 ATS switch The load breaker specifications for the ATS and ON-GRID for one inverter model shall be the same. 94 No. Circuit breaker 3 Residual Current Protector (RCD) 4 (Optional) Manual conversion switch Recommended specifications RCD device installation and RCD specification selection: It is recommended to connect an A-type RCD with a residual current trip threshold of >= 300mA to the AC output side of the inverter (for inverters with a capacity <30kVA, the residual current trip threshold should be selected as 300mA; for inverters with a capacity >= 30kVA, the residual current trip threshold should be selected as 10mA/kVA). Alternatively, the appropriate RCD specifications may be selected in accordance with local regulatory requirements. • Nominal Voltage>=230Vac • Nominal Current: 63A 6.3.2 Preparing Cables 95 Acquisitio n method Comment Prepared by customers - Prepared by customers Shipped with inverter. (Only for Australia) Integrated Meter (Single inverter) No. Cable 1 Inverter PE cable 2 PV DC cable Recommended specifications • Single-core outdoor copper cable • Cross-sectional area: S=5.2mm²6mm² • Commonly used outdoor photovoltaic cable • Cross-sectional area: 4mm²-6mm² Acquisition method Prepared by customers Prepared by customers • Outer diameter: 5.9mm-8.8mm • AC input and output cables of inverter (BACK UP/ ON GRID): • Cross-sectional area: 4mm²-16mm² GW3K-EHA-G20, GW3.6K- EHAG20: 4mm²-6mm² GW5K-EHA-G20, GW6K-EHA-G20: 6mm²-10mm² GW8K-EHA-G20, GW9.999K, EHAG20, GW10K-EHA-G20: 10mm²-16mm² • Outer diameter of multi-core outdoor copper cable: 10mm-21mm ○ 3 AC cable ○ Prepared by customers ○ 4 Smart meter power cable 5 Smart meter RS485 communicatio n cable • Outdoor copper cable • Conductor Cross-sectional area: 1mm² • Shielded twisted pair cable • Cross-sectional area: 0.2mm²0.4mm² 96 Prepared by customers Prepared by customers No. 6 7 8 9 10 Cable EMS or charging pile RS485 communicatio n port Remote shutdown and NS Protection communicatio n line Load control and generator control DO communicatio n cable RCR/DRED signal cable CT communicatio n cable Recommended specifications Acquisition method • Shielded cable that meets local standards • Cross-sectional area: 0.2mm²0.4mm² • Outer diameter: 5mm-8mm Prepared by customers Standard Network Cable: CAT 5E or higher specification standard network cable and RJ45 connectors Prepared by customers • RJ45 crimping tool 11 Communicatio n cable for parallel connected inverters • Straight-through network cable of CAT 5E or higher specification The recommended length for CAT 5E or CAT 6E shall not exceed 5 meters. The recommended length for CAT 7E shall not exceed 10 meters. ○ ○ 6.4 Connecting the PE Cable WARNING 97 Prepared by customers • The PE cable connected to the enclosure of the inverter cannot replace the PE cable connected to the AC output port. Make sure that both of the two PE cables are securely connected. • To improve the corrosion resistance of the terminal, you are recommended to apply silica gel or paint on the ground terminal after installing the PE cable. • Connect the PE cable first before installing the equipment. Disconnect the PE cable before dismantling the equipment. • The battery grounding is integrated into the blind-plug connector connected to the inverter. The system is uniformly grounded through the inverter, eliminating the need for separate battery grounding during installation. 6.5 Connecting the PV cable DANGER • Do not connect the same PV string to multiple inverters at the same time. Otherwise, the inverters may be damaged. • Confirm the following information before connecting the PV string to the inverter. Otherwise, the inverter may be damaged permanently or even cause fire and cause personal and property losses. 1. Make sure that the max short circuit current and the maximum input voltage per MPPT are within the permissible range. 2. Make sure that the positive pole of the PV string connects to the PV+ of the inverter. And the negative pole of the PV string connects to the PV- of the inverter. WARNING 98 • The PV strings cannot be grounded. Ensure the minimum insulation resistance of PV string to the ground meets the minimum insulation resistance requirements before connecting the PV string to the inverter (R=maximum input voltage/30mA). • Ensure the DC cables are connected tightly, securely and correctly. • Measure the positive and negative terminals of the DC cable using a multimeter to avoid reverse polarity connection. Also, the voltage should be within the permissible range. NOTICE • The two input strings per MPPT should be of the same type, the same number of PV panels, the same tilt and angle to ensure the best efficiency. Type I: If disassembly of the PV terminal is required, please refer to the following steps: 99 Type II: If disassembly of the PV terminal is required, please refer to the following steps: 6.6 Connecting the AC Cable WARNING 100 • The residual current monitoring unit (RCMU) is integrated into the inverter to avoid the residual current exceeds the limit. The inverter will disconnect the utility grid quickly once it found the residual current exceeds the limit. • Connect the AC cables to the corresponding terminals such as “BACKUP”, “ONGRID” correctly. Otherwise it will cause damage to the inverter. • Ensure that the whole cable cores are inserted into the terminal holes, and no part of the cable core can be exposed. • Ensure that the insulation board is inserted into the AC terminal tightly. • Ensure that the cables are connected securely. Otherwise it will cause damage to the inverter due to overheat during its operation. A: GW3K-EHA-G20, GW3.6K-EHA-G20 B: GW5K-EHA-G20, GW6K-EHA-G20 C: GW8K-EHA-G20, GW9.999K-EHA-G20, GW10K-EHA-G20 Type I: If disassembly of the AC terminal is required, please refer to the following steps: 101 Type II: If disassembly of the AC terminal is required, please refer to the following steps: 102 (Optional) Connect manual Changeover switch 6.7 Connecting the Meter Cable 103 NOTICE • Contact the manufacturer for additional smart meters if multiple inverters are connected. • Ensure that the CT is connected in the correct direction and phase sequences, otherwise the monitoring data will be incorrect. • Ensure all cables are connected tightly, securely, and correctly. Inappropriate wiring may cause poor contacts or high impedances, and damage the inverter. • In areas at risk of lightning, if the meter cable exceeds 10m and the cables are not wired with grounded metal conduits, you are recommended to use an external lightning protection device. Wiring of GMK110 NOTICE • Outer diameter of the AC cable should be smaller than the holes diameter of the CT, so that the AC cable can be routed through the CT. • To ensure accurate current detection, the CT cable is recommended to be shorter than 30m. • Do not use network cable as the CT cable, otherwise the smart meter may be damaged due to high current. • The CTs vary slightly in dimensions and appearance depending on the model, but they are installed and connected in the same way. Connection steps 104 Wiring of GM330 smart meter Connection steps Installing the CT (Type I) 105 Installing the CT (Type II) 6.8 Connecting the Inverter Communication Cable 106 NOTICE • When using the built-in smart meter, please use the delivered CT. • If you need to use the DRED, RCR or remote shutdown function, turn it on in the SolarGo App after wiring. • Do not turn on the remote shutdown function in the SolarGo App if the inverter is not connected to a DRED device, otherwise the inverter will be unable to operate on-grid. • In a parallel system, please connect the DRED, RCR communication cable to the master inverter to achieve the DRED、RCR function. • To ensure the inverter's waterproof rating, do not remove the waterproof plugs from the unused communication ports on the inverter. • For the DO signal communication port of the inverter, which connect dry contact signals, the specification are as follows: Max <= 24Vdc, 1A. • The communication functions are optional. Connect the cables based on actual needs. • The inverter supports parameter setting via Bluetooth nearby. It also supports connecting to mobile phones or WEB interfaces through communication modules such as WiFi and LAN to set device-related parameters, view device operation information and error messages, and keep abreast of the system status in a timely manner. • In the single inverter system, installation of the WiFi/LAN Kit-20 or 4G Kit-CN-G20 smart dongle is supported. • In a parallel system, both the master and slave inverters must be installed with the WiFi/LAN Kit-20 smart dongle for networking. • When using the 4G Kit- CN-G20: If parallel operation and networking are required, please contact GoodWe to purchase the WiFi/LAN Kit-20. The built-in SIM card of the 4G smart dongle is a mobile communication card, please confirm whether the device is installed in an area covered by mobile 4G signals. If the installation area is not covered by mobile signal, please contact the operator to optimize the signal. It supports connection to a third-party monitoring platform via the MQTT communication protocol. • 4G Kit-CN-G20 is an LTE single-antenna device, suitable for application scenarios with low requirements for data transmission rate. ○ ○ ○ Communication Function Description 107 Port (Silk screen printing) A PAR1 B PAR2 C CT Function Description Parallel Communication Port 1 Parallel Communication Port 2 Parallel communication port. Please use CAT 5E and above standard network cable and RJ45 connector CT connection port CT communication cables only need to be connected when using the inverter's built-in meter. 108 Port (Silk screen printing) DRM/RCR Function RCR, DREDorEnWG 14afunctional connection port D E Description • RCR (Ripple Control Receiver): It provides an RCR signal control port to meet the grid dispatching requirements in Europe. • DRED (Demand Response Enabling Device): It provides an DRED signal control port to meet DERD certification requirements in Australia and other regions.. METER Smart Meter Connection Port DI • External remote shutdown or local NS protection devices are turned off by default. • In a rapid shutdown system, the rapid shutdown transmitter and receiver work together to achieve rapid system Remote shutdown. The receiver maintains the shutdown /NS modules output by continuously receiving protection/Rapid a heartbeat signal from a transmitter. The shutdown transmitter can be external or integrated into the inverter. In case of an emergency, you can enable the external initiator to shut down the transmitter, by which the RSD will stop working and the modules be shut down. F LOAD Load Control Use RS485 communication to connect external smart meters. • Support connecting dry contact signals to achieve load control and other functions. DO contact capacity is 12V DC@1A, NO/COM normally open contact. • Support SG Ready heat pump connection, control the heat pump through dry contact signal to control the heat pump. 109 Port (Silk screen printing) GEN G EMS H SW1 I SW2 Function Generator Control Port Description A single unit in the network supports accessing the generator control signal to control the generator's start and stop. In microgrid scenarios, connection to a generator is not supported. EMS/Charging Pile Communication Port Connecting to a third-party EMS device for energy control or connect to a GoodWe charging pile. Parallel DIP Switches In a multi-inverter parallel operation scenario, set the parallel DIP switches of the first and last inverters to the ON position, and set those of the other inverters to the OFF position. Method to connect the communication cable 110 7 System Commissioning 7.1 Check Before Power ON No. Check Item 1 The inverter is firmly installed in a clean place where is well-ventilated and easy to operate. 2 The PE, DC, AC, communication cables are connected correctly and securely. 3 The cable binding shall comply with routing requirements, with reasonable distribution and no damage. 4 Unused wire holes and ports should connect with reliable terminals provided with the accessories and be sealed up. 5 The used cable holes are sealed. 6 The voltage and frequency at the connection point meet the inverter grid connection requirements. 7.2 Power ON 111 WARNING • Battery Black Start Function: When there is no PV power generation in the photovoltaic system and the grid is abnormal, if the inverter cannot operate normally, the battery black start function can be used to force the battery to discharge and start the inverter. The inverter can then enter off-grid mode and operate, with the battery supplying power to the load. • After the battery system is started, please ensure that the communication between the inverter and the battery system is normal within 15 minutes. If the inverter cannot communicate normally with the battery system, the battery system switch will be automatically disconnected, and the battery system will be powered off. • When the inverter is operating normally, set the manual transfer switch to position B to supply power to the load via the inverter's BACK-UP port. During inverter shutdown maintenance or in the event of a fault, to ensure uninterrupted load operation, switch the manual transfer switch to position A to supply power to the load from the utility grid. Power on 112 1. Turn on the ON-GRID circuit breaker. 2. Turn on the BACK-UP circuit breaker, and (optionally) set the manual switch to the B position. 3. Turn the battery power switch to the ON position and briefly press the battery multifunction button. When there are multiple batteries in the system, turn all the battery power switch to the ON position. Briefly press the battery multifunction button. 4. (optional) Turn on the circuit breaker between the PV module and the inverter. 5. (optional) Turn on the DC switch of the inverter. Battery Black Start: 1. Turn on the ON-GRID circuit breaker. 2. Turn on the BACK-UP circuit breaker. 3. Turn on the battery system switch. 113 4. Turn on the DC switch of the inverter. 5. Press and hold any battery multi-function button for 2 seconds to start the battery system, and the battery will discharge to activate the inverter. 7.3 Installing Protective Cover 7.4 Indicators 7.4.1 Inverter Indicator Breathing light: 114 • When the system is in the upgrade state: the breathing light is a green marquee; the marquee is brightest at the beginning and darkest at the end. The length of the marquee light and the upgrade percentage are affected by the SEMS+ APP settings and the device operating status.SEMS+ APP SettingsDevice Status • The breathing light status is affected by the settings on the SEMS+ APP except for the inverter upgrade, system failure and inverter power-off status. If you need to set it, please refere to the 11.7.1.“Setting Energy Storage Inverter Parameters”(Page 244) Indicat or Indicator status Breathing Light Status • 3min/normal on: bluepurple running light is steady on • normal off: off Description The inverter is power on and in the standby mode. The inverter is starting and in self-test mode. • 3min: Blue-purple breathing turns off after 3 minutes • APP normal on: bluepurple running light is steady on • APP normal off: off The inverter is in normal operation under grid-tied or off-grid mode. Blinking red System Failure Off The inverter is powered off. / The monitoring module of the inverter is resetting. The inverter fails to connect with the communication termination. 115 Indicat or Indicator status Breathing Light Status Description Communication fault between the communication Termination and Server. The monitoring of the inverter operates well. The monitoring module of the inverter has not been started yet. The grid is abnormal, and the power supply to the BACK-UP port of the inverter is normal. The grid is normal, and the power supply to the BACK-UP port of the inverter is normal. The BACK-UP port has no power supply. System Updating System Failure The battery has no power Steady on: Charging Flashing: Discharging Battery SOC: 0%<SOC≤25% 116 Indicat or Indicator status Breathing Light Status Description Steady on: Charging Flashing: Discharging Battery SOC: 25%<SOC≤50% Steady light: Charging Flash: Discharging Battery Battery SOC: 50%<SOC≤75% Steady on: Charging Flashing: Discharging Battery SOC: 75%<SOC≤100% 7.4.2 Battery Indicators Button Indicator No. Green light 1 On Blinks 1 time/S. 2 3 Blinks 3 time/S. Blinks 1 time/ 2S. Red light -- -- -- Battery system Description The system is working normally. Run The system is ready. Standby The PCScommunication is lost. -- System Alarm When there is an undervoltage fault of level 2, 3, or 4, the indicator flashes. For other level 2 faults, the indicator flashes. 117 No. 4 Green light Red light -- On Battery system Description System Failure Fault list showing faults of level 3 or higher (undervoltage faults remain ON when at level 5) 7.4.3 Smart Meter Indicator GM330 Type Power light Communication indicator Importing or exporting indicator Status On Blinks. Off Off Description Power on, no RS485 communication. Power on, RS485 communication works properly. The smart meter has been powered off. Reserved Blinks. Press the Reset button for more than 5 seconds, power light, buying or selling electricity indicator light flash: Reset the meter. On Blinks. Importing from the grid. Exporting to the grid. Off Do not import from and export to the grid. Reserved GMK110 Type Power light Status On Description The smart meter is power on. Off The smart meter has been powered off. Blinks. Meter communication is normal. 118 Type Status Communication indicator Off Description Meter communication is abnormal or has no communication. 7.4.4 Smart Dongle Indicator • WiFi/LAN Kit-20 Note • After double press the Reload button to turn on Bluetooth, the communication indicator light will switch to single flash. Please connect to the SolarGo App within 5 minutes or Bluetooth will turn off automatically. • The single flash status of the communication indicator only appears after doublepress the Reload button to turn on Bluetooth. Indicator Power Communi cation indicator Status Description Power On: The smart dongle is powered on. Power Off: The smart dongle is powered off. Power On: The WiFi or LAN communication is working well. Blinks 1 time: The Bluetooth signal is on and waiting for connection to the SolarGo app. Blinks 2 times: The Smart Dongle is not connected to the router. Blinks 4 times: The Smart Dongle is communicating with the router but not connected to the server. Blinks 6 times: The Smart Dongle is identifying the connected device. Power Off: The software of the Smart Dongle is in reset or not powered on. 119 Indicator Communic ation indicator in LAN Port Color Green Status On Description The 100Mbps wired network is normally connected. • The Internet cable is not connected. Off On Yellow Blinks Off Button • The 100Mbps wired network is abnormally connected. • The 10Mbps wired network is normally connected. The10/100Mbps wired network is normally connected, but no communication data is received or transmitted. The communication data is being transmitted or received. The Internet cable is not connected. Description Press and hold for 0.5 to 3 seconds to reset the Smart Dongle. Press and hold for 6 to 20 seconds to restore the Smart Dongle to factory settings. Reload Double press quickly to activate Bluetooth signal (only lasts for 5 minutes). • 4G Kit-CN-G20 Indicator Status Description Power On: The Smart Dongle is powered on. Off The Smart Dongle is powered off. Power On: The Smart Dongle is connected to the server and the communication is normal. Blinks 2 times: The Smart Dongle is not connected to the foundation. 120 Indicator Status Description Blinks 4 times: The Smart Dongle is connected to the foundation but disconnected to the server. Blinks 6 times: The Smart Dongle is not connected to the inverter. Power Off: The software of the Smart Dongle is in reset or not powered on. Button RELOAD Description Press and hold for 0.5 to 3 seconds to reset the Smart Dongle. Press and hold for 6 to 20 seconds to restore the Smart Dongle to factory settings. 121 8 Rapid System Configuration 8.1 Downloading the App 8.1.1 Downloading SolarGo App Make sure that the mobile phone meets the following requirements: • Mobile phone operating system: Android 5.0 or later, iOS 13.0 or later. • The mobile phone can access the Internet. • The mobile phone supports WLAN or Bluetooth. NOTICE Once the SolarGo App has been installed, you will receive automatic notifications when updates are available. Method 1: Search SolarGo in Google Play (Android) or App Store (iOS) to download and install the app. Method 2: Scan the QR code below to download and install the App. 8.1.2 Downloading SEMS+ APP Make sure that the mobile phone meets the following requirements: • Mobile phone operating system: Android 6.0 or later, iOS 13.0 or later. • The mobile phone can access the Internet. • The mobile phone supports WLAN or Bluetooth. 122 Download Method: Method 1: Search SEMS+ in Google Play (Android) or App Store (iOS) to download and install the App. Method 2: Scan the QR code below to download and install the App. 8.2 Connecting the Hybrid Inverter (Bluetooth) Step 1 Ensure that the inverter is power on, both the inverter and the communication module are working properly. Step 2 Select Bluetooth tab on the SolarGo app hompage. Step 3 Pull down or tap Search Device to refresh the device list. Find the device by the the inverter serial number. Tap the device name to log into the Home page. Select the device by checking the serial number of the master inverter when multi inverters are parallel connected. Step 4 For first connection with the equipment via Bluetooth, there will be a Bluetooth pairing prompt, tap Pair to continue the connection. Step 5 Log in as an Owner or an Installer. Initial password: 1234. Default password: 1234. Step 6 (Optional): If connecting via WLA-*** or WFA-***, enable Bluetooth Stays On following the prompts as entering the device details page. Otherwise, the bluetooth signal of the device will be off after disconnection. 123 8.3 Connect the Smart Dongle When connecting to an inverter via the SolarGo App, if the inverter signal cannot be detected, the device list interface will display the signal of the smart dongle connected to the inverter. 124 Supported Smart Dongle types: • WiFi/LAN Kit-20 • Ezlink3000 • 4G Kit-CN-G20 ; 4G Kit-CN-G21 ; 4G Kit-G20 Step 1: On the homepage of the SolarGo App, find the grayed-out SN number of the smart dongle and click to enter the settings interface. Step 2: Set or query parameter information according to actual needs. • Communication Configuration: Click to set WLAN/LAN parameters and connect the module to the router. • Communication Module Logs: Click to enter the module log download interface. • Device Information: Click to view the firmware version of the smart dongle. If a version update is available, you can refer to the on-screen prompts to complete the update. 8.4 Setting Communication Parameters 125 NOTICE The communication configuration interface may be different if the inverter uses different communication modes or connects different communication modules. Please refer to the actual interface. 8.4.1 Setting Privacy and Security Parameters Type I Step 1 : Tap Home > Settings > Communication Setting > Privacy & Security to set the parameters. Step 2 : Set the new password for the WiFi hotspot of the communication module, and tap Save. Step 3 Open the WiFi settings of your phone and connect to the inverter’s WiFi signal (Solar WiFi***) with the new password. 126 Type II Step 1 : Tap Home > Settings > Communication Setting > Privacy & Security to set the parameters. Step 2 Enable Bluetooth Stays On or WLAN Control based on actual needs. 127 No. Parameters Description Bluetooth Stays On Disabled by default. Enable the function, the bluetooth of the device will be contentious on to keep connected to SolarGo. Otherwise, the bluetooth will be off in 5 minutes, and the device will be disconnected from SolarGo. WLAN Control Disabled by default. Enable the function, the device and the SolarGo can be connected through the WLAN when they are on the same LAN. Otherwise, they cannot be connected even if they are on the same LAN. 3 Modbus-TCP Enable the function, the third party monitoring platform can access inverter through Modbus-TCP communication protocol. 4 SSH control Ezlink After enabling this function, third-party platforms can connect to and control EzLink's Linux system. 1 2 Type III Step 1 : Tap Home > Settings > Communication Setting > Privacy & Security to set 128 the parameters. Step 2 : Enable Bluetooth Stays On or Login Password based on actual needs. No. 1 2 Parameters Description Bluetooth Stays On Disabled by default. Enable the function, the bluetooth of the device will be contentious on to keep connected to SolarGo. Otherwise, the bluetooth will be off in 5 minutes, and the device will be disconnected from SolarGo. Password Disabled by default. Enable the function, you will be prompted to enter the login password when connecting the device to SolarGo. Use the initial password and change it at the first login prompt. 8.4.2 Setting WLAN/LAN Parameters 129 NOTICE When the inverter is connected to different communication modules, the communication configuration interface may be different. Please refer to the actual interface. Step 1 : Tap Home > Settings > Communication Setting > WLAN/LAN to set the parameters. Step 2 : Configure the WLAN or LAN parameters based on actual needs. No. Parameters Description 1 Network Name Only for WLAN. Select WiFi based on the actual connecting. 2 Password Only for WLAN. WiFi password for the actual connected network. 3 DHCP Enable DHCP when the router is in dynamic IP mode. Disable DHCP when a switch is used or the router is in static IP mode. 130 No. Parameters 4 IP Address 5 Subnet Mask 6 Gateway Address 7 DNS Server Description Do not configure the parameters when DHCP is enabled. Configure the parameters according to the router or switch information when DHCP is disabled. 8.4.3 Configuring RS485 Parameters NOTICE Set the communication address of the inverter. For a single inverter, the address is set based on actual needs. For multi connected inverters, the address of each inverter should be different while cannot be 247. Step 1: Tap Home > Settings > Communication Settings > RS485 to set the parameters. Step 2 : Set the Modbus Address And Baud Rate base on actual situation. 131 8.5 Quick Setting the Basic Information 132 NOTICE • The setting page varies depending on inverter model. • The parameters will be configured automatically after selecting the safety country/region, including overvoltage protection, undervoltage protection, overfrequency protection, underfrequency protection, voltage/frequency connection protection, cosφ curve, Q(U) curve, P(U) curve, FP curve, HVRT, LVRT, etc. Tap Home > Settings > Advanced Settings > Safety Parameters to check the parameters after selecting the safety country. • The power generation efficiency is different in different working modes. Set the working mode according to the local requirements and situation. Self-use mode: The basic working mode of the system. PV power generation is used to supply power to the load first, the excess power is used to charge the battery, and the remaining power is sold to the grid. When PV power generation cannot meet the load's power demand, the battery will supply power to the load; when the battery power also cannot meet the load's power demand, the grid will supply power to the load. Back-up mode: The back-up mode is mainly applied to the scenario where the grid is unstable. When the grid is disconnected, the inverter turns to off-grid mode and the battery will supply power to the load; when the grid is restored, the inverter switches to grid-tied mode. Economic mode: It is recommended to use economic mode in scenarios when the peak-valley electricity price varies a lot. Select Economic mode only when it meets the local laws and regulations. Set the battery to charge mode during Vally period to charge battery with grid power. And set the battery to discharge mode during Peak period to power the load with the battery. Off-grid mode: suitable for areas without power grid. PV and batteries form a pure off-grid system. PV generates electricity to power the load and excess electricity charges the battery. When PV power generation cannot meet the power demand of the load, the battery will supply power to the load. Smart charging: In some countries/regions, the PV power feed into the utility grid is limited. Select Smart Charging to charge the battery using the surplus power to minimize PV power waste. Peak shaving mode: Peak shaving mode is mainly applicable to peak power limited scenarios. When the total power consumption of the load exceeds the power consumption quota in a short period of time, battery discharge can be used to reduce the power exceeding the quota. ○ ○ ○ ○ ○ ○ 133 8.5.1 Quick Setting the Basic Information(Type I) Step 1: Tap Home > Settings > Quick Settings to set the parameters. Step 2 : Enter the password for quick settings. Contact the supplier or after sales service for password. Password for professional technicians only. Step 3 : Some models support one-click configuration. Select Guided Mode to quickly configure the system. Step 4: Select Grid Code(Safety Code)accordingly. Tap Next to set the Working Mode. Step 5: Set the working mode based on actual needs. Tap Next to set the Working Mode. For some models, after the working mode configuration is completed, it will automatically enter the CT/meter self-test state. At this time, the inverter will temporarily disconnect from the grid and then automatically reconnect. Step 6 : Select the battery based on actual situation whether it is First Installation, Routine Operation or Replacement Installation. 134 No. Parameters Description Back-up mode 1 Charging Power Enable Charging Power From Grid to allow power From Grid purchasing from the utility grid. 2 Charging Power The percentage of the purchasing power to the rated power of the inverter. TOU mode 135 No. Parameters Description 3 Start Time Within the Start Time and End Time, the battery is charged or discharged according to the set Battery Mode as well as the Rated Power. 4 End Time 5 Charge Discharge Mode Charge or discharge according to actual needs. 6 Rated Power The percentage of the charging/discharging power to the rated power of the inverter. 7 Charge Cut-off SOC The battery stop charging/discharging once the battery SOC reaches Charge Cut-off SOC. Peakshaving 8 9 10 Reserved SOC For Peakshaving In Peak Shaving mode, the battery SOC should be lower than Reserved SOC For Peakshaving. Once the battery SOC is higher than Reserved SOC For Peakshaving, the peak shaving mode fails. Peak Power Purchase Limit Set the maximum power limit allowed to purchase from the grid. When the loads consume power exceed the sum of the power generated in the PV system and Peak Power Purchase Limit, the excess power will be made up by the battery. Time for Charging From Grid The utility grid will charge the battery between Start Time and End Time if the load power consumption do not exceed the power quota. Otherwise, only PV power can be used to charge the battery. Otherwise, only PV power can be used to charge the battery. Smart charging Set the Peak Power Sales Limit in compliance with local laws and regulations. The Peak Limiting Power shall be lower then the output power limit specified by local requirements. 11 Peak Power Sales Limit 12 PV Prioritizes During charging time, the PV power will first charge the Charing Battery battery. 136 No. 13 Parameters Description Start Charging Time Step 7 : For devices that support one-click configuration, a template can be generated based on the completed configuration. Step 8: If you already have a one-click configuration template, you can use the existing template direct import mode to quickly complete the configuration. 137 8.6 Creating a Station Step 1: Tap on overview or station page, or tap Create Station on service page. Step 2: Enter station information on theCreat Station page. Step 3: Tap Save&Exit to complete creating a station, without devices added. Or tap Save&Continue to add devices. Support adding multiple devices. 138 9 System Commissioning 9.1 Commissioning Method Overview Please use the SolarGo App to configure the parameters. 9.2 SolarGo APP 9.2.1 Product Introduction NOTICE • All the user interface (UI) screenshots or words in this document are based on SolarGo app V6.6.0. The UI may be different due to the version upgrade. The screenshots, words or data are for reference only. • The method to set parameters is the same for all inverters. But the parameters displayed varies based on the equipment model and safety code. Refer to the actual interface display for specific parameters. • Before setting any parameters, read through user manual of the App and the inverter or charger to learn the product functions and features. When the inverter parameters are set improperly, the inverter may fail to connect to the utility grid or fail to connect to the utility grid in compliance with related requirements and damage the battery, which will affect the inverter’s power generation. SolarGo App is a mobile application that communicates with the inverter via Bluetooth, WIFi, 4G, or GPRS. Commonly used functions are as follows: • Check the operating data, software version, alarms of the inverter, etc. • Set grid parameters and communication parameters of the inverter. • Set charging mode of the charger. • Maintain the equipment. 9.2.1.1 Downloading and Installing the App Make sure that the mobile phone meets the following requirements: 139 • Mobile phone operating system: Android 5.0 or later, iOS 13.0 or later. • The mobile phone can access the Internet. • The mobile phone supports WLAN or Bluetooth. NOTICE After installing the app, it can automatically prompt users to update the app version. Method 1: Search SolarGo in Google Play (Android) or App Store (iOS) to download and install the app. Method 2: Scan the QR code below to download and install the app. 9.2.1.2 App Connection Connect as the following shows after powering on the equipment. NOTICE The connection distance varies depending on smart dongles. Refer to the actual used smart dongles. 140 9.2.1.3 GUI Introductions to Login Page No. 1 Name/Icon Description Tap the icon to open the page downloading the SEMS Portal app. 141 No. Name/Icon 2 Description Tap to read the connection guide. Not found 3 • Check information such as app version, local contacts, etc. • Other settings, such as update date, switch language, set temperature unit, etc. 4 Select based on actual communication method. If you have Bluetooth/Wi any problems, tap or NOT Found to read the connection Fi/4G guides. • The list of all devices. The last digits of the device name are normally the serial number of the device. • Select the device by checking the serial number of the master inverter when multi inverters are parallel connected. • The device name varies depending on the inverter model or smart dongle model: Wi-Fi/LAN Kit, Wi-Fi Kit, Wi-Fi Box: Solar-WiFi*** ○ 5 6 Device List Search Device ○ External or integrated bluetooth mudule:Solar-BLE*** ○ WiFi/LAN Kit-20: WLA-*** ○ WiFi Kit-20: WFA-*** ○ Ezlink3000:CCM-BLE***;CCM-***;*** ○ 4G Kit-CN-G20/4G Kit-CN-G21: GSA-***; GSB-*** ○ 4G Kit-G20:GSC-*** ○ Micro inverter: WNN*** ○ AC Charger: *** Tap Search Device if the device is not found. 142 9.2.2 Connecting the Hybrid Inverter (Bluetooth) Step 1 Ensure that the inverter is power on, both the inverter and the communication module are working properly. Step 2 Select Bluetooth tab on the SolarGo app hompage. Step 3 Pull down or tap Search Device to refresh the device list. Find the device by the the inverter serial number. Tap the device name to log into the Home page. Select the device by checking the serial number of the master inverter when multi inverters are parallel connected. Step 4 For first connection with the equipment via Bluetooth, there will be a Bluetooth pairing prompt, tap Pair to continue the connection. Step 5 Log in as an Owner or an Installer. Initial password: 1234. Default password: 1234. Step 6 (Optional): If connecting via WLA-*** or WFA-***, enable Bluetooth Stays On following the prompts as entering the device details page. Otherwise, the bluetooth signal of the device will be off after disconnection. 143 9.2.3 Connect the Smart Dongle When connecting to an inverter via the SolarGo App, if the inverter signal cannot be detected, the device list interface will display the signal of the smart dongle connected to the inverter. 144 Supported Smart Dongle types: • WiFi/LAN Kit-20 • Ezlink3000 • 4G Kit-CN-G20 ; 4G Kit-CN-G21 ; 4G Kit-G20 Step 1: On the homepage of the SolarGo App, find the grayed-out SN number of the smart dongle and click to enter the settings interface. Step 2: Set or query parameter information according to actual needs. • Communication Configuration: Click to set WLAN/LAN parameters and connect the module to the router. • Communication Module Logs: Click to enter the module log download interface. • Device Information: Click to view the firmware version of the smart dongle. If a version update is available, you can refer to the on-screen prompts to complete the update. 9.2.4 GUI Introductions to Hybrid Inverters 145 No. Name/Icon Description 1 Serial Number Serial number of the connected inverter. 2 Device Status Indicates the status of the inverter, such as Working,Fault, etc. 3 Energy Flow Chart Indicates the energy flow chart of the PV system. The actual page prevails. 4 Indicates the system status, such as Safety Code, Working System Status Mode, Battery Model, Battery Status, Power Limit, ThreePhase Unbalanced Output, etc.. 5 Home. Tap Home to checkSerial Number, Device Status, Energy Flow Chart, System Status, etc. 6 Parameters. Tap Parameters to check the inverter Data. 146 No. 7 Name/Icon Description • Settings Tap to perform quick settings, basic settings, advanced settings, etc. on the inverter. • Login required to access Quick Setup and Advanced Setting. Contact the supplier or after sales service for password. Password for professional technicians only. 9.2.5 Setting Communication Parameters NOTICE The communication configuration interface may be different if the inverter uses different communication modes or connects different communication modules. Please refer to the actual interface. 9.2.5.1 Setting Privacy and Security Parameters Type I Step 1 : Tap Home > Settings > Communication Setting > Privacy & Security to set the parameters. Step 2 : Set the new password for the WiFi hotspot of the communication module, and tap Save. Step 3 Open the WiFi settings of your phone and connect to the inverter’s WiFi signal (Solar WiFi***) with the new password. 147 Type II Step 1 : Tap Home > Settings > Communication Setting > Privacy & Security to set the parameters. Step 2 Enable Bluetooth Stays On or WLAN Control based on actual needs. 148 No. Parameters Description Bluetooth Stays On Disabled by default. Enable the function, the bluetooth of the device will be contentious on to keep connected to SolarGo. Otherwise, the bluetooth will be off in 5 minutes, and the device will be disconnected from SolarGo. WLAN Control Disabled by default. Enable the function, the device and the SolarGo can be connected through the WLAN when they are on the same LAN. Otherwise, they cannot be connected even if they are on the same LAN. 3 Modbus-TCP Enable the function, the third party monitoring platform can access inverter through Modbus-TCP communication protocol. 4 SSH control Ezlink After enabling this function, third-party platforms can connect to and control EzLink's Linux system. 1 2 Type III Step 1 : Tap Home > Settings > Communication Setting > Privacy & Security to set 149 the parameters. Step 2 : Enable Bluetooth Stays On or Login Password based on actual needs. No. 1 2 Parameters Description Bluetooth Stays On Disabled by default. Enable the function, the bluetooth of the device will be contentious on to keep connected to SolarGo. Otherwise, the bluetooth will be off in 5 minutes, and the device will be disconnected from SolarGo. Password Disabled by default. Enable the function, you will be prompted to enter the login password when connecting the device to SolarGo. Use the initial password and change it at the first login prompt. 9.2.5.2 Setting WLAN/LAN Parameters 150 NOTICE When the inverter is connected to different communication modules, the communication configuration interface may be different. Please refer to the actual interface. Step 1 : Tap Home > Settings > Communication Setting > WLAN/LAN to set the parameters. Step 2 : Configure the WLAN or LAN parameters based on actual needs. No. Parameters Description 1 Network Name Only for WLAN. Select WiFi based on the actual connecting. 2 Password Only for WLAN. WiFi password for the actual connected network. 3 DHCP Enable DHCP when the router is in dynamic IP mode. Disable DHCP when a switch is used or the router is in static IP mode. 151 No. Parameters 4 IP Address 5 Subnet Mask 6 Gateway Address 7 DNS Server Description Do not configure the parameters when DHCP is enabled. Configure the parameters according to the router or switch information when DHCP is disabled. 9.2.5.3 Configuring RS485 Parameters NOTICE Set the communication address of the inverter. For a single inverter, the address is set based on actual needs. For multi connected inverters, the address of each inverter should be different while cannot be 247. Step 1: Tap Home > Settings > Communication Settings > RS485 to set the parameters. Step 2 : Set the Modbus Address And Baud Rate base on actual situation. 152 9.2.6 Setting Up the RS485 Parallel System NOTICE • When paralleling hybrid inverters via RS485, you must set each inverter as the master or slave inverter individually using the SolarGo App. • When an inverter in a parallel system needs to be used as a single unit, it must be set to standalone inverter via the SolarGo App. • Please set the inverter connected to the meter as the master. • Please first set the slave inverter address, then set the parallel network through the master. Step 1: Go to the settings interface via Settings > Parallel System Settings . Step 2: Set the inverter to Master, Slave, or Stand-alone based on its actual wiring. • If the inverter is the master, set it to Master and then exit the connection. After setting the slave inverter address, return to this interface, click Parallel Networking, set the number of inverters in the parallel system, and then click Network. • If the inverter is the slave, set the Inverter Address and click √. 153 9.2.7 Quick Setting the Basic Information 154 NOTICE • The setting page varies depending on inverter model. • The parameters will be configured automatically after selecting the safety country/region, including overvoltage protection, undervoltage protection, overfrequency protection, underfrequency protection, voltage/frequency connection protection, cosφ curve, Q(U) curve, P(U) curve, FP curve, HVRT, LVRT, etc. Tap Home > Settings > Advanced Settings > Safety Parameters to check the parameters after selecting the safety country. • The power generation efficiency is different in different working modes. Set the working mode according to the local requirements and situation. Self-use mode: The basic working mode of the system. PV power generation is used to supply power to the load first, the excess power is used to charge the battery, and the remaining power is sold to the grid. When PV power generation cannot meet the load's power demand, the battery will supply power to the load; when the battery power also cannot meet the load's power demand, the grid will supply power to the load. Back-up mode: The back-up mode is mainly applied to the scenario where the grid is unstable. When the grid is disconnected, the inverter turns to off-grid mode and the battery will supply power to the load; when the grid is restored, the inverter switches to grid-tied mode. Economic mode: It is recommended to use economic mode in scenarios when the peak-valley electricity price varies a lot. Select Economic mode only when it meets the local laws and regulations. Set the battery to charge mode during Vally period to charge battery with grid power. And set the battery to discharge mode during Peak period to power the load with the battery. Off-grid mode: suitable for areas without power grid. PV and batteries form a pure off-grid system. PV generates electricity to power the load and excess electricity charges the battery. When PV power generation cannot meet the power demand of the load, the battery will supply power to the load. Smart charging: In some countries/regions, the PV power feed into the utility grid is limited. Select Smart Charging to charge the battery using the surplus power to minimize PV power waste. Peak shaving mode: Peak shaving mode is mainly applicable to peak power limited scenarios. When the total power consumption of the load exceeds the power consumption quota in a short period of time, battery discharge can be used to reduce the power exceeding the quota. ○ ○ ○ ○ ○ ○ 155 9.2.7.1 Quick Setting the Basic Information(Type I) Step 1: Tap Home > Settings > Quick Settings to set the parameters. Step 2 : Enter the password for quick settings. Contact the supplier or after sales service for password. Password for professional technicians only. Step 3 : Some models support one-click configuration. Select Guided Mode to quickly configure the system. Step 4: Select Grid Code(Safety Code)accordingly. Tap Next to set the Working Mode. Step 5: Set the working mode based on actual needs. Tap Next to set the Working Mode. For some models, after the working mode configuration is completed, it will automatically enter the CT/meter self-test state. At this time, the inverter will temporarily disconnect from the grid and then automatically reconnect. Step 6 : Select the battery based on actual situation whether it is First Installation, Routine Operation or Replacement Installation. 156 No. Parameters Description Back-up mode 1 Charging Power Enable Charging Power From Grid to allow power From Grid purchasing from the utility grid. 2 Charging Power The percentage of the purchasing power to the rated power of the inverter. TOU mode 157 No. Parameters Description 3 Start Time Within the Start Time and End Time, the battery is charged or discharged according to the set Battery Mode as well as the Rated Power. 4 End Time 5 Charge Discharge Mode Charge or discharge according to actual needs. 6 Rated Power The percentage of the charging/discharging power to the rated power of the inverter. 7 Charge Cut-off SOC The battery stop charging/discharging once the battery SOC reaches Charge Cut-off SOC. Peakshaving 8 9 10 Reserved SOC For Peakshaving In Peak Shaving mode, the battery SOC should be lower than Reserved SOC For Peakshaving. Once the battery SOC is higher than Reserved SOC For Peakshaving, the peak shaving mode fails. Peak Power Purchase Limit Set the maximum power limit allowed to purchase from the grid. When the loads consume power exceed the sum of the power generated in the PV system and Peak Power Purchase Limit, the excess power will be made up by the battery. Time for Charging From Grid The utility grid will charge the battery between Start Time and End Time if the load power consumption do not exceed the power quota. Otherwise, only PV power can be used to charge the battery. Otherwise, only PV power can be used to charge the battery. Smart charging Set the Peak Power Sales Limit in compliance with local laws and regulations. The Peak Limiting Power shall be lower then the output power limit specified by local requirements. 11 Peak Power Sales Limit 12 PV Prioritizes During charging time, the PV power will first charge the Charing Battery battery. 158 No. 13 Parameters Description Start Charging Time Step 7 : For devices that support one-click configuration, a template can be generated based on the completed configuration. Step 8: If you already have a one-click configuration template, you can use the existing template direct import mode to quickly complete the configuration. 159 9.2.8 Setting the Basic Information 9.2.8.1 Setting the SPD After enabling SPD, when the SPD module is abnormal, there will be SPD module abnormal alarm prompt. Step 1 : Tap Home > Settings > Basic Settings > SPD, to set the parameters. Step 2 : enable or disable the function based on actual needs. 9.2.8.2 Setting the Back-up Power Parameters After enabling Backup, the battery will power the load connected to the backup port of the inverter to ensure Uninterrupted Power Supply when the power grid fails. Step 1 : Tap Home > Settings > Basic Settings > Backup, to set the parameters. Step 2 : Set the backup supply function based on actual needs. 160 No. Parameters Description 1 UPS Mode- Full Wave Detection Check whether the utility grid voltage is too high or too low. 2 UPS Mode- Half Wave Detection Check whether the utility grid voltage is too low. 3 EPSmode-with LVRT support. Stop detecting utility grid voltage. 4 First Cold Start (Off-grid) It will only take effect once. In off-grid mode, enable First Cold Start (Off-grid) to output backup supply with battery or PV. 5 Take effect multiple times. In off-grid mode, enable First Cold Start Holding Cold Start (Off-grid) to output backup supply with (Off-grid) battery or PV. 161 No. 6 Parameters Description Clear Overload History Once the power of loads connected to the inverter BACK-UP ports exceeds the rated load power, the inverter will restart and detect the power again. The inverter will perform restart and detection several times until the overloading problem is solved. Tap Clear Overload History to reset the restart time interval after the power of the loads connected to the BACK-UP ports meets the requirements. The inverter will restart immediately. 9.2.8.3 Setting the Shadow Scan Enable Shadow Scan when the PV panels are severely shadowed to optimize the power generation efficiency. Step 1 : Tap Home > Settings > Basic Settings> Shadow Scan, to set the parameters. Step 2: Enable or disable the function based on actual needs. Set the Shadow Scan interval and MPPT shadow scan if the inverter supports. 162 9.2.8.4 Setting Power Adjustment Parameters Step 1: Go to the settings interface via Home > Settings > Basic Settings > Power Scheduling. Step 2: Set the active power dispatch or reactive power dispatch parameters according to the actual situation. 163 No. Parameter Description Active Scheduling 1 2 Active Scheduling Mode According to the requirements of the power grid company in the country/region where the inverter is located, control the active power according to the selected dispatch mode. Supports: • Disabled: Disables active scheduling. • Fixed value reduction: Dispatch according to a fixed value. • Percentage reduction: Dispatch based on a percentage of the rated power. Active Power • When the active power dispatch mode is set to fixed value derating, the active power is set to a fixed value. • When the active power dispatch mode is set to percentage derating, the active power is set as a percentage of the rated power. ⽐。 Reactive Scheduling 3 4 Reactive Scheduling Mode According to the requirements of the power grid company in the country/region where the inverter is located, control the reactive power according to the selected dispatch mode. Supports: • Disabled: Disables reactive scheduling. • Fixed value compensation: Dispatch according to a fixed value. • Percentage compensation: Dispatch based on a percentage of the rated power. • PF compensation. Status Set the power factor as lagging or leading based on actual needs and local grid standards and requirements. 164 No. Parameter Description 5 Reactive Power • When the reactive power dispatch mode is set to fixed value derating, the reactive power is set to a fixed value. • When the reactive power dispatch mode is set to percentage derating, the reactive power is set as a percentage of the rated power. 6 Power Factor When the reactive power dispatch mode is set to PF compensation, set the power factor. 9.2.9 Setting Advanced Parameters NOTICE Contact the supplier or after sales service for Advanced Setting password. Password for professional technicians only. 9.2.9.1 Setting DRED/Remote Shutdown/RCR/EnWG 14a Enable DRED/Remote Shutdown/RCR before connecting the third party DRED, remote shutdown, or RCR device to comply with local laws and regulations. Step 1 : Tap Home > Settings > Advanced Settings > DRED/Remote Shutdown/RCR to set the parameters. Step 2 : Enable or disable the function based on actual needs. Step 3 : For areas where the EnWG 14a regulation applies, when enabling the RCR function, you need to select the RCR mode according to the actual device type and set the DI port power. 165 9.2.9.2 Setting the Backup N and PE Relay Switch To comply with local laws and regulations, ensure that the relay inside the back-up 166 port remains closed and the N and PE wires are connected when the inverter is working off-grid. Step 1 : Tap Home > Settings > Advanced Settings > Backup N and PE Relay Switch to set the parameters. Step 2 : Enable or disable the function based on actual needs. 9.2.9.3 Setting the Power Limit Parameters Step 1: Tap Home > Settings > Advanced Settings > Power Limit to set the parameters. Step 2 : Turn on or off the power limit function according to actual needs. Step 3 : After turning on the function, enter the parameter value according to actual needs and tap "√" to successfully set the parameter. 9.2.9.3.1 Set the grid-connected power limit parameters (general) 167 No. Parameters Description 1 Power Limit Turn on this function when output power needs to be limited according to the grid standards of some countries or regions. 2 Export Power Set according to the maximum power that can be input to the grid. 3 External Meter Set the ratio of the primary current to the secondary current of CT ratio the external CT. 9.2.9.3.2 Setting the Power Limit Parameters (Australia) 168 No. Parameter s Description 1 Software Power Limit When output power needs to be limited according to grid standards in some countries or regions, turn on this function. Limit Setting • Set according to the maximum power that can be actually input to the grid. • Supports setting of fixed power value or percentage. The set percentage is the percentage of the limit power to the rated power of the inverter. • After setting the fixed value, the percentage changes automatically; after setting the percentage, the fixed value changes automatically. 2 169 No. Parameter s Description 3 Hardware Power Limit After enabling this function, when the amount of electricity fed into the grid exceeds the limit value, the inverter will automatically disconnect from the grid. 4 External Meter CT Ratio Set the ratio of the primary current to the secondary current of the external CT. 9.2.9.4 Setting the AFCI Detection Step 1 : Tap Home > Settings > Advanced Settings > AFCI Test to set the parameters. Step 2 : Enable AFCI Test, Clear AFCI Alarm and Self-Check based on actual needs. No. Parameters Description 1 AFCI Test Enable or disable AFCI accordingly. 2 AFCI Test Status The detection status like Not Self-checking. 3 Clear AFCI Alarm Clear ARC Faulty alarm records. 4 Self-check Tap to check whether the AFCI function works normally. 9.2.9.5 Setting the Battery 170 9.2.9.5.1 Set Parameters for Lithium Battery Step 1: Tap Home > Settings> Advanced Settings > Battery Function Settings to set the parameters. Step 2: Set the parameters based on actual needs. No. Parameter Description Parameter Settings 1 Max. Charging Current Only applicable to certain models. Set the maximum charging current based on actual needs. 2 Max. Discharging Current Only applicable to certain models. Set the maximum discharging current based on actual needs. 171 No. Parameter Description Optional. This option is displayed on the interface when a battery that supports heating is connected. After the battery heating function is turned on, when the temperature is below the value that starts up the battery, PV power or electricity from the grid will be used to heat the battery. Heating Mode: • GW5.1-BAT-D-G20/GW8.3-BAT-D-G20 Low Power Mode: Maintains minimum battery power input capacity, turns on when the temperature is below -9℃, and turns off when the temperature is above or equal to -7℃. Medium Power Mode: to maintain the moderate power input capacity of the battery. It will be turned on when the temperature is less than 6℃, and turned off when it is greater than or equal to 8℃. High Power Mode: to maintain the higher power input capacity of the battery. It will be turned on when the temperature is less than 11℃, and turned off when it is greater than or equal to 13℃. • GW14.3-BAT-LV-G10 Low Power Mode: Maintains minimum battery power input capacity, turns on when the temperature is below 5℃, and turns off when the temperature is above or equal to 7℃. Medium Power Mode: to maintain the moderate power input capacity of the battery. It will be turned on when the temperature is less than 10℃, and turned off when it is greater than or equal to 12℃. High Power Mode: to maintain the higher power input capacity of the battery. It will be turned on when the temperature is less than 20℃, and turned off when it is greater than or equal to 22℃. ○ ○ 3 Battery Heating ○ ○ ○ ○ 172 No. Parameter Description 4 • After being turned on, the battery can be awakened when it shuts down due to undervoltage protection. Battery Wake-up • Only applicable to lithium batteries without circuit breakers. After being turned on, the output voltage of the battery port is about 60V. Limit Protection 5 SOC Protection Start battery protection when the battery capacity is lower than the Depth of Discharge. 6 SOC Limit The upper limit value for battery charging. Charging stops when the battery SOC reaches the SOC upper limit. 7 Discharge Depth The maximum discharge value allowed for the battery (On-grid) when the inverter is in the on-grid scenario. To ensure that the battery SOC is sufficient to maintain normal operation when the system is off-grid, the battery will purchase electricity from the grid and charge to the set SOC protection value when the system is connected to the grid. 8 Backup Power SOC Maintenance 9 Discharge Depth The maximum discharge value allowed for the battery (Off-grid) when the inverter is in the off-grid scenario. 10 Off-grid SOC Recovery When the inverter is operating off-grid, if the battery SOC drops below the lower limit, the inverter stops outputting power and only charges the battery until the battery SOC returns to the off-grid recovery SOC value. If the SOC lower limit value is higher than the off-grid recovery SOC value, charge to SOC lower limit +10%. Immediate Charging 11 Immediate Charging Enable to charge the battery by the grid immediately. This takes effect once. Enable or Disable based on actual needs. 173 No. Parameter Description 12 SOC for Stopping Charging Stop charging the battery once the battery SOC reaches SOC For Stopping Charging. 13 Immediate Charging Power Indicates the percentage of the charging power to the inverter rated power when enabling Immediate Charging. For example, for an inverter with a rated power of 10kW, when set to 60, the charging power is 6kW. 14 Start Start charging immediately. 15 Stop Immediately stop the current charging task. 9.2.9.6 Setting PV Connect Mode Select the PV connect mode based on the actual connections between the PV strings and MPPT ports of the inverter. Step 1 : Tap Home > Settings > Advanced Settings > PV Connect Mode to set the parameters. Step 2 : Set the connect mode to Independent Access, Partial Parallel Connect or Parallel Connection based on actual connections. 174 No. Parameters Description 1 Stand-alone Connect The external PV string is connected to multi MPPT terminals of the inverter. Partial Parallel Connect The PV strings are connected to the inverter in both stand-alone and parallel connection. For example, one PV string connect to MPPT1 ad MPPT2, another PV string connect to MPPT3. Parallel Connect When an external PV string is connected to the PV input port on the inverter side, one PV string is connected to multiple PV input ports. 2 3 9.2.10 Setting Safety Parameters 175 NOTICE Set the custom safety parameters in compliance with local requirements. Do not change the parameters without the prior consent of the grid company. 9.2.10.1 Setting the Reactive Power Mode Step 1 : Tap Home > Settings > Advanced Settings > Safety Parameter Setting > Reactive Power Mode Settings to set the parameters. Step 2 :Set the parameters based on actual needs. Q(U) Curve 176 Cosφ Curve No. Parameters Description 1 Fix PF Enable Fix PF when it is required by local grid standards and requirements. After the parameters are set successfully, the power factor remains unchanged during the operation of the inverter. 2 Under-excited 3 Over-excited 4 Power Factor Fix PF Set the power factor as lagging or leading based on actual needs and local grid standards and requirements. Set the power factor based on actual needs. Range: 0-~0.8, or +0.8~+1. Fix Q 177 No. Parameters Description 1 Fix Q Enable Fix Q when it is required by local grid standards and requirements. 2 Overexcited/Underexcited Set the reactive power as inductive or capacitive reactive power based on actual needs and local grid standards and requirements. 3 Reactive Power Set the ratio of reactive power to apparent power. Q(U) Curve 1 Q(U) Curve Enable Q(U) Curve when it is required by local grid standards and requirements. 2 Mode Selection Set Q(U) curve mode, supporting basic mode and slope mode. Vn Voltage The percentage of actual voltage to the rated voltage at Vn point, n=1, 2, 3, 4. When set to 90, it means: V/Vrated% = 90%. 4 Vn Reactive Power The percentage of the reactive output power to the apparent power at Vn point, n=1, 2, 3, 4. For example, setting Vn Reactive Power to 48.5 means Q/Srated%=48.5%。 5 Voltage Deadband Width When Q(U) curve mode is set to slope mode, this parameter defines the voltage deadband range where no reactive power output is required. 6 Over-excitation Slope 7 Underexcitation Slope 3 8 Vn Reactive Power (In Q(U) slope mode) Sets the positive or negative slope for reactive power variation during over-voltage conditions. The percentage of the reactive output power to the apparent power at Vn point, n=1, 2, 3, 4. For example, setting Vn Reactive Power to 48.5 means Q/Srated%=48.5%。 178 No. Parameters Description 9 Q(U) Curve Response Time Constant The reactive power must reach 95% of the target value within 3 time constants, following a first-order low-pass filter curve. 10 Extended Function Enable the extended function and configure the corresponding parameters. 11 Lock-In Power 12 Lock-out Power When the inverter output reactive power to the rated power ratio is between the Lock-in power and Lock-out power, the ratio meets Q(U) curve requirements. Cosφ(P) Curve 1 Cosφ(P) Curve Enable Cosφ Curve when it is required by local grid standards and requirements. 2 Mode Selection Set cosφ(P) Curve Mode and support basic mode and slope mode configurations. 3 N-point Power The percentage of inverter output active power relative to rated power at the N-point. N=A, B, C, D, E。 4 N-point cosφ Value N-point Power Factor N=A, B, C, D, E。 5 Over-excitation Slope 6 Underexcitation Slope 7 N-point Power The percentage of inverter output active power relative to rated power at the N-point. N=A, B, C。 8 N-point cosφ Value N-point Power Factor N=A, B, C。 9 cosφ(P) Curve Response Time Constant The reactive power must reach 95% of the target value within 3 time constants, following a first-order low-pass filter curve. 10 Extended Function Enable the extended function and configure the corresponding parameters. When cosφ(P) curve mode is set to slope mode, configures the power variation slope as either positive or negative. 179 No. Parameters Description 11 Lock-in Voltage 12 Lock-out Voltage When the grid voltage is between Lock-in Voltage and Lock-out Voltage, the voltage meets Cosφ curve requirements. Q(P) Curve 1 Q(P) Curve Function Enable Q(P) Curve when it is required by local grid standards and requirements. 2 Mode Selection Set Q(P) curve mode, supporting basic mode and slope mode. 3 Pn-point Power The percentage of the output reactive power to the rated power at Pn point, n=1, 2, 3, 4, 5, 6. For example, setting to 90 means Q/Prated%=90%. 4 Pn-point Reactive Power The percentage of the output active power to the rated power at Pn point, n=1, 2, 3, 4, 5, 6. For example, When set to 90, it means: P/Prated% = 90%. 5 Over-excitation Slope 6 Underexcitation Slope When the Q(P) curve mode is set to slope mode, configure the power variation slope as either a positive or negative value. 7 Pn-point Power Ratio of reactive power to rated power at Pn points (n=1, 2, 3). For example, setting to 90 means Q/Prated%=90%. 8 Pn-point Reactive Power Ratio of active power to rated power at Pn points (n=1, 2, 3). For example, When set to 90, it means: P/Prated% = 90%. Time Constant The reactive power must reach 95% of the target value within 3 time constants, following a first-order low-pass filter curve. 9 180 9.2.10.2 Setting the Active Power Mode Step 1: Tap Home > Settings > Advanced Settings > Safety Parameter Settings > Active Power Mode Settings to set the parameters. Step 2: Set the parameters based on actual needs. P(F) Curve P(U) Curve 181 No. Parameter Explanation s 1 Generation Power Limit Set the change slope when the active output power increases or decreases. 2 Power Gradient Set the active power change slope. Overfrequency Unloading Enable P(F) Curve when it is required by local grid standards and requirements. 1 P(F) Curve 2 OverFrequency Load Shedding Mode 3 The inverter output active power will decrease when the utility Overfreque grid frequency is too high. The inverter output power will ncy decrease when the utility grid frequency is higher than Threshold Overfrequency Threshold. Set the overfrequency unloading mode based on actual needs. • Slope mode: adjusts power based on the over frequency point and load reduction slope. • Stop mode: adjusts the power based on the over-frequency start point and over-frequency end point. 182 No. Parameter Explanation s 4 Import/Exp ort When the set frequency value is reached, the system switches Electricity from selling electricity to buying electricity. Conversion Frequency 5 The inverter output active power will decrease when the utility Overfreque grid frequency is too high. The inverter output power will stop ncy decreasing when the utility grid frequency is higher than Endpoint Overfrequency Endpoint. 6 OverFrequency Power Slope Reference Power 7 Power response to The inverter output active power will increase when the utility overfreque grid frequency is too high. Indicates the slope when the ncy inverter output power decreases. gradient 8 Tentional Delay Ta Indicates the delayed response time when the inverter output power is higher than the Overfrequency Threshold. 9 Hysteretic Function Enable the hysteretic function. 10 Frequency Hysteresis Point During over-frequency load reduction, if the frequency decreases, the power output is based on the lowest point of the load reduction power until the frequency is less than the hysteresis point and the power is restored. 11 Hysteresis Waiting Time For over-frequency load reduction and frequency decrease, when the frequency is less than the hysteresis point, the power recovery waiting time, that is, it takes a certain amount of time to recover the power. Adjust the inverter output power based on Apparent Active Power, Rated Active Power, Momentary Active Power, Or Max. Active Power. 183 No. Parameter Explanation s 12 Hysteresis Power Recovery Slope Reference Power For over-frequency load reduction and frequency decrease, when the frequency is less than the hysteresis point, the power recovery benchmark, that is, the power recovery is based on the recovery slope * the rate of change of the reference power. Support: Pn rated power, Ps apparent power, Pm current power, Pmax maximum power, power difference (△P). 13 Hysteretic Power Recovery Slope For over-frequency load reduction and frequency reduction, when the frequency is less than the hysteresis point, the power change slope when the power is restored. Underfrequency Loading 1 P(F) Curve Enable P(F) Curve when it is required by local grid standards and requirements. Set the underfrequency unloading mode based on actual needs. 2 Underfrequ • Slope mode: adjusts power based on the underfrequency ency Load point and load increase slope. Mode • Stop mode: adjusts the power based on the underfrequency start point and underfrequency end point. 3 The inverter output active power will increase when the utility Underfrequ grid frequency is too low. The inverter output power will ency increase when the utility grid frequency is lower than Threshold Underfrequency Threshold. 4 Import/Exp ort When the set frequency value is reached, the system switches Electricity from selling electricity to buying electricity. Conversion Frequency 184 No. Parameter Explanation s 5 The inverter output active power will increase when the utility Underfrequ grid frequency is too low. The inverter output power will stop ency increasing when the utility grid frequency is lower than Endpoint Underfrequency Endpoint. 6 OverFrequency Power Slope Reference Power Adjust the inverter output power based on Apparent Active Power, Rated Active Power, Momentary Active Power, Or Max. Active Power. 7 UnderFrequency Power Slope The inverter output active power will increase when the utility grid frequency is too low. The slope of the inverter output power when it rises. 8 Tentional Delay Ta Indicates the delayed response time when the inverter output power is lower than the Underfrequency Threshold. 9 Hysteretic Function Enable the hysteretic function. 10 Frequency Hysteresis Point During underfrequency loading, if the frequency increases, the power is output according to the lowest point of the loaded power until the frequency is higher than the hysteresis point and the power is restored. 11 Hysteresis Waiting Time For underfrequency loading, the frequency increases, when the frequency is higher than the hysteresis point, the waiting time for power recovery, that is, it takes a certain amount of time to recover the power. 185 No. Parameter Explanation s 12 Hysteresis Power Recovery Slope Reference Power For underfrequency loading, the frequency increases, when the frequency is higher than the hysteresis point, the benchmark for power recovery, that is, the power recovery is carried out according to the recovery slope * the rate of change of the benchmark power. Support: Pn rated power, Ps apparent power, Pm current power, Pmax maximum power, power difference (△P). 13 Hysteretic Power Recovery Slope For under-frequency loading, frequency increase, when the frequency is higher than the hysteresis point, the power change slope when power is restored. 14 P(U) Curve Enable P(U) Curve when it is required by local grid standards and requirements. Vn Voltage The percentage of actual voltage to the rated voltage at Vn point, n= 1, 2, 3, 4. For example, setting Vn Voltage to 90 means V/Vrated%=90%. Vn Active Power The percentage of the output active power to the apparent power at Vn point, (n= 1, 2, 3, 4). For example, setting Vn Reactive Power to 48.5 means P/Prated%=48.5%. 17 Output Response Mode Set the active power output response mode. Supports: • PT-1 Behavior, realize active scheduling based on the firstorder LPF curve within the response time constant. • Gradient Control, realize active scheduling based on the power change slope. 18 Power Gradient When the output response mode is set to Gradient Control, active power scheduling is achieved according to the power change gradient. 15 16 186 No. Parameter Explanation s 19 First-order Low-pass Filter Time Parameter Set the time constant within which the active power changes based on the first order LPF curve when the Output Response Mode is set to be First-order Low-pass Filter Time Parameter. 20 Overload Function Switch When enabled, the maximum active power output is 1.1 times the rated power; otherwise, the maximum active power output is consistent with the rated power value. 9.2.10.3 Setting Protection Parameters Step 1 : Tap Home > Settings > Advanced Settings > Safety Parameter Settings > Protection Parameters to set the parameters. Step 2: Set the parameters based on actual needs. No. Parameters Description 1 OV Stage n Trip Value Set the grid overvoltage protection threshold value, n=1,2,3,4. 2 OV Stage n Trip Time Set the grid overvoltage protection tripping time, n=1,2,3,4. 3 UV Stage n Trip Value Set the grid undervoltage protection threshold value, n=1,2,3,4. 4 UV Stage n Trip Time Set the grid undervoltage protection tripping time. 5 10min Overvoltage Trip Set the 10min overvoltage protection threshold Threshold value. 6 10min Overvoltage Trip Set the 10min overvoltage protection tripping Time time. 7 OF Stage n Trip Value Set the grid overfrequency triggering n-th order protection point, n=1,2,3,4. 8 OF Stage n Trip Time Set the grid overfrequency trigger n-th order trip time, n=1,2,3,4. 187 No. Parameters Description 9 UF Stage n Trip Value Set the grid underfrequency triggering n-th order protection point, n=1,2,3,4. 10 UF Stage n Trip Time Set the grid underfrequency trigger n-th order trip time, n=1,2,3,4. 9.2.10.4 Setting Connection Parameters Step 1 : Tap Home > Settings > Advanced Settings > Safety Parameter Settings > Protection Parameters to set the parameters. Step 2: Set the parameters based on actual needs. No. Parameters Description Ramp Up 1 Upper Voltage The inverter cannot connect to the grid if it is powered on for the first connection and the grid voltage is higher than the Upper Voltage. 2 Lower Voltage The inverter cannot connect to the grid if it is powered on for the first connection and the grid voltage is lower than the Lower Voltage. 3 Upper Frequency The inverter cannot connect to the grid if it is powered on for the first connection and the grid frequency is higher than the Upper Frequency. 188 No. Parameters Description 4 Lower Frequency The inverter cannot connect to the grid if it is powered on for the first connection and the grid frequency is lower than the Lower Frequency. 5 Observation Time The waiting time for connecting the inverter to the grid when meeting the following requirements. 1. The inverter is powered on for the first connection. 2. The utility grid voltage and frequency meet certain requirements. 6 Soft Ramp Up Enable the start up power slope. Gradient 7 Indicates the percentage of incremental output power per Soft Ramp Up minute based on the local requirements when the inverter is Gradient powered on for the first time. Reconnection 8 Upper Voltage The inverter cannot connect to the grid if it is reconnecting due to a fault and the grid voltage is higher than the Upper Voltage. 9 Lower Voltage The inverter cannot connect to the grid if it is reconnecting due to a fault and the grid voltage is lower than the Lower Voltage. 10 Upper Frequency The inverter cannot connect to the grid if it is reconnecting due to a fault and the grid frequency is higher than the Upper Frequency. 11 Lower Frequency The inverter cannot connect to the grid if it is reconnecting due to a fault and the grid frequency is lower than the Lower Frequency. 12 Observation Time The waiting time for connecting the inverter to the grid when meeting the following requirements. 1. The inverter is reconnecting to the grid due to a fault. 2. The utility grid voltage and frequency meet certain requirements. 13 Reconnection Enable the start up power slope. Gradient 189 No. Parameters Description 14 Indicates the percentage of incremental output power per minute based on the local requirements when the inverter is Reconnection powered on for the first time. For example, setting Gradient Reconnection Gradient to 10 means the reconnect slope is 10%P/Srated/min. 9.2.10.5 Setting Voltage Ride Through Parameters Step 1 : Tap Home > Settings > Advanced Settings > Safety Parameter Settings > Voltage Ride Through to set the parameters. Step 2 : Set the parameters based on actual needs. No. Parameters Description LVRT 1 UVn Voltage The ratio of the ride through voltage to the rated voltage at UVn point during LVRT. n=1,2,3,4,5,6,7。 2 UVn Time The ride through time at UVn point during LVRT. n=1,2,3,4,5,6,7 3 Enter Into LVRT Threshold 4 Exit LVRT Endpoint 5 Slope K2 K-factor for reactive power during LVRT. 6 Zero Current Mode The system outputs zero current during LVRT. 7 Entry Threshold Set the entry threshold of zero current mode. The inverter will not be disconnected from the utility grid immediately when the grid voltage is between Enter Into LVRT Threshold and Exit LVRT Endpoint. HVRT 190 No. Parameters Description 1 OVn Voltage The ratio of the ride through voltage to the rated voltage at OVn point during HVRT. n=1,2,3,4,5,6,7。 2 OVn Time The ride through time at OVn point during HVRT. n=1,2,3,4,5,6,7。 3 Enter High Crossing Threshold 4 Exit High Crossing Threshold 5 Slope K2 K-factor for reactive power during HVRT. 6 Zero Current Mode The system outputs zero current during HVRT. 7 Entry Threshold Set the entry threshold of zero current mode. The inverter will not be disconnected from the utility grid immediately when the grid voltage is between Enter High Crossing Threshold and Exit High Crossing Threshold. 9.2.10.6 Setting Frequency Ride Through Parameters Step 1 : Tap Home > Settings > Advanced Settings > Safety Parameter Settings > Frequency Ride Through to set the parameters. Step 2 : Set the parameters based on actual needs. No. Parameters Description 1 UFn Frequency The frequency at the UFn point during frequency ride through. 2 UFn Frequency The frequency at the UFn point during frequency ride through. n=1,2,3。 3 UFn Time The ride through duration at the UFn point during frequency ride through. n=1,2,3。 191 No. Parameters Description 4 OFn Frequency The frequency at the OFn point during frequency ride through. n=1,2,3。 5 OFn Time The ride through duration at the OFn point during frequency ride through. n=1,2,3。 9.2.11 Exporting Parameters 9.2.11.1 Exporting Safety Parameters After selecting the safety code, some models support exporting safety parameter files. Step 1 : Tap Home > Settings > Advanced Settings > Export to export the parameters. Step 2 : Select Safety Parameters, and tap Export to start downloading the current safety parameter file. When the export is complete, tap Share and choose how you want to open the exported file. 192 9.2.11.2 Exporting Log Parameters Step 1 : Tap Home > Settings > Advanced Settings > Export. Step 2 : Select the device type to export logs, such as inverter logs, communication module logs, etc. Step 3: Select the log type to export, download and export the log file. After the export is complete, tap Share and choose how to open the exported file according to actual needs. 9.2.12 Setting the Meter Parameters 9.2.12.1 Bind/Unbind Meter 193 NOTICE • When the PV system uses both the grid-connected inverter and the energy storage inverter to achieve coupling or microgrid functions, dual meters may be used in the system. Please set the meter binding information according to the actual usage. • Applicable only to GoodWe meters. Step 1 : Tap Home > Settings > Meter Function > Meter Binding to enter the binding interface. Step 2 : Tap Quantity/Location of Meters to select the actual application scenario. Supported options: Meter 1 (built-in) No Meter 2; Meter 1 (external) No Meter 2; Meter 1 (built-in) Meter 2 (external); Meter 1 (external) Meter 2 (external). the interface of Meter 1 (built-in) Meter 2 (external) is used as an example to explain how to bind the meter. Step 3 : As shown in the figure below, when you choose to use an external meter, you need to manually add the external meter information. Tap to bind the meter by manually entering the meter SN or scanning the meter SN QR code. When the bound meter model is GM330, please set the meter CT ratio according to the actual situation and click √ to complete the setting. If you use other meters, you do not need to set the meter CT ratio. Step 4 : (Optional) If you need to unbind the external meter, please tap Remove Binding. 194 9.2.12.2 Meter/CT-Assisted Test Meter/CT-Assisted Test is used to auto-check if the Smart Meter and CT are connected in the right way and their working status. Step 1 : Tap Home > Settings > Meter/CT Assisted Test to set the function. Step 2 : Tap Start Test to start test. Check Test Result after test. 195 9.2.13 Setting Generator/Load Control 9.2.13.1 Setting Load Control NOTICE • Loads and generators can be controlled by SolarGo app when the inverter supports load control function. • For ET40-50kW series inverters, the load control function is supported only when the inverter is used with STS. The inverter supports load control of the GENERATOR port or the BACKUP LOAD port. Step 1: Tap Home > Settings > Port Connection to set the parameters. Step 2: Select Generator Control or Load Control based on actual needs. • Dry Contact Mode: when the switch is ON, the loads will be powered; when the switch is OFF, the power will be cut off. Turn on or off the switch based on actual needs. • Time Mode: set the time to enable the load, and the load will be powered automatically within the setting time period. Select standard mode or intelligent mode. 196 No. Parameters Description 1 Standard The loads will be powered within the setting time period. 2 Intelligent Once the excess energy of the photovoltaic exceeds the load nominal power within the time period, the loads will be powered. 3 Start Time 4 End Time The time mode will be on between the Start Time and End Time. 5 Repeat The repeat days. 6 The shortest load working time after the loads been Load Consumption powered. The time is set to prevent the loads be turned Time on and off frequently when the PV power fluctuates greatly. Only for Intelligent mode. 7 The loads will be powered when the excess energy of the Load Rated Power photovoltaic exceeds the nominal power of load. Only for Intelligent mode. • SOC Mode: the inverter has integrated dry contact controlling port, which can control whether the load is powered or not by contactor. In off-grid mode, the load connected to the port will not be powered if the BACKUP overload is detected or 197 the battery SOC value is lower than the Off-grid battery protection value. Set Offgrid Battery Protection Value based on actual needs. 9.2.13.2 Setting the Generator Parameters NOTICE • When the inverter supports the generator control function, the generator can be controlled through the SolarGo App. • For ET40-50kW series inverters, the generator can be connected and controlled only when the inverter is used with STS. Step 1 : Tap Home > Settings > Port Connection to set the parameters. Step 2: Select Generator Connection or Load Connection based on actual needs. Step 3 : When setting the generator control function, select the generator type according to the actual access situation. Currently supported:Not Installed, Manual Control Of Generator or Automatic Control Generator. And set the parameters according to the selected generator type. • Not Installed: If no generator is connected in the system, select Not Installed. • Manual Control Of Generator(Doesn’t Support Dry Node Connection): Start or stop the generator manually. The inverter cannot control the generator when Manual Control Of Generator(Doesn’t Support Dry Node Connection) is selected. 198 • Automatic control generator (Supports dry node connection): If the generator has dry contact port and is connected to the inverter, set the generator control mode to Switch Control Mode or Automatic Control Mode based on actual needs. Switch Control Mode: The generator will start working when the Generator Dry Node Switch is on, and stop automaticallly after reaching Run Time. Automatic Control Mode: The generator will work during Run Time, but stop working during Prohibited Working Hours. ○ ○ No. Parameters Description 1 Startup Mode Switch Control Mode/Automatic Control Mode Switch Control Mode 199 No. Parameters Description 2 Generator Dry Node Switch Only for Switch Control Mode. 3 Run Time Set the generator’s continuous runtime, after which the generator will be turned off. Automatic Control Mode Prohibited Working Hours Set the time period during which the generator cannot work. 5 Run Time Set the generator’s continuous runtime, after which the generator will be turned off. If the generator start-up operation time includes prohibited working time, the generator will stop running during this time period; after the prohibited working time, the generator will restart running and timing. No. Parameters Description 4 Generator Information Settings 1 Rated Power Set the rated power of the generator. 2 Run Time Set the continuous running time of the generator. The generator will be shut down after the continuous running time ends. 3 Upper Voltage 4 Lower Voltage 5 Frequency Cap 6 Lower Frequency 7 Preheating time Set the operation voltage range of the generator. Set the operation frequency range of the generator. Set the generator no-load preheating time. Parameter settings for generator charging batteries 8 Switch Select whether to use the generator to generate electricity to charge the battery. 200 No. Parameters Description 9 Max.charging power (‰) The charging power when the generator generates electricity to charge the battery. 10 Start charging SOC When the battery SOC is lower than this value, the generator generates electricity to charge the battery. 11 Stop charging SOC When the battery SOC is higher than this value, stop charging the battery. 9.2.13.3 Setting Microgrid Parameters NOTICE When the inverter supports microgrid function, you can set microgrid parameters through SolarGo App. Step 1 : Tap Home > Settings > Port Connection to set the parameters. Step 2 : According to the actual interface prompts, enter the microgrid control interface and set the microgrid parameters according to actual needs. 201 No. Parameters Description 1 Maximum SOC for Charging Set the upper limit of charging SOC, and stop charging when the upper limit is reached. Manual wake-up • When the grid fails, if the battery power is low, the energy storage inverter cannot be supported to work off the grid. Click this button to force the energy storage inverter to output voltage to the grid-connected inverter, thereby starting the gridconnected inverter. • Single effect. 2 202 No. Parameters Description 3 Automatic wakeup • When the grid fails, if the battery power is low, the energy storage inverter cannot be supported to work off the grid. After enabling this function, the system will force the energy storage inverter to output voltage to the grid-connected inverter at a fixed time, thereby starting the grid-connected inverter. • Multiple effect. 4 Grid Import Power Limit Offset Set the adjustable range of the maximum power that the device can actually buy from the grid. 9.2.14 Equipment Maintenance 9.2.14.1 Checking Firmware Information/Upgrading Firmware Version Upgrade the DSP version, ARM version, BMS version, AFCI version, or STS version of the inverter, or firmware version of the communication module. Some devices do not support upgrading the firmware version through SolarGo app. NOTICE If the Firmware Upgrade dialog box pops up once logging into the app, click Firmware Upgrade to directly go to the firmware information page. 9.2.14.1.1 Regular Upgrade 203 NOTICE • When there is a red dot on the right side of the firmware information, please click to view the firmware update information. • During the upgrade process, please ensure that the network is stable and the device is connected to SolarGo, otherwise the upgrade may fail. Step 1 : Tap Home > Settings > Firmware Information to check the firmware version. If the firmware upgrade dialog box pops up, tap Firmware Upgrade and turn to the upgrade interface. Step 2 : (Optional) Tap Check For Update to confirm whether the latest firmware version is available for updating. Step 3: Tap Firmware Upgrade to enter the firmware upgrade interface. Step 4 : (Optional) Tap Learn More to view firmware-related information, such as the current version, the latest version, firmware update records, etc. Step 5 : Tap Upgrade and complete the upgrade according to the prompts on the interface. 204 9.2.14.1.2 One-click Upgrade NOTICE • When there is a red dot on the right side of the firmware information, please click to view the firmware update information. • During the upgrade process, please ensure that the network is stable and the device is connected to SolarGo, otherwise the upgrade may fail. Step 1 : Tap Home > Settings > Firmware Information. Tap Firmware Information as prompted to enter the firmware upgrade page. Step 2 : Tap Upgrade and follow the prompts to complete the upgrading. If you only need to upgrade a specific firmware version, tap Learn More to check the firmware related information and tap Firmware Upgrade below the firmware version you want to upgrade, and follow the on-screen prompts to complete the operation. Step 3 : Tap Learn More to view all current firmware version information. Step 4: (Optional)Tap ,to view the version upgrade record. 9.2.14.1.3 Automatic Upgrade NOTICE • When using WiFi/LAN Kit-20 or WiFi Kit-20 module communication and the module firmware version is V2.0.1 or above, the device automatic upgrade function can be enabled. • After the device automatic upgrade function is enabled, if the module version is updated and the device has been connected to the network, the corresponding firmware version can be automatically upgraded. Step 1 : Tap Home > Settings > Firmware Information. Step 2 : Enable or disable the automatic device upgrade function according to actual needs. 9.2.14.2 Change the Login Password 205 NOTICE The login password can be changed. Keep the changed password in mind after changing it. Contact the after-sales service if you forget the password. Step 1 : Tap Home > Settings > Change Login Password to change the password. Step 2 : Change the password based on actual needs. 206 207 10 Station Monitoring NOTICE The parameters may vary depending on the account type or power station type. The actual interface takes precedence. 10.1 Product Introduction SEMS+ App is a monitoring platform to manage power plants and devices, and check the operating data and alarming information of the power plant. 10.1.1 Applicable Product Model SEMS+ App can be used to monitor and manage GoodWe products, such as inverters, smart meters, smart loggers,chargers, batteries and so on. 10.1.2 Downloading and Installing the App Make sure that the mobile phone meets the following requirements: • Operating system: Android 6.0 or later, iOS 13.0 or later. • Internet connection via browser. • WLAN/Bluetooth capabilities. Download Methods: Method I Search SEMS+ on Google Play (Android) or App Store (iOS) to download and install the App. Method II Scan the QR code below to download and install the App. 208 10.1.3 App Connection 10.1.4 Setting Language and Server NOTICE The server is automatically matched based on login account information. To set it manually, ensure that the selected region matches the region of the account. Otherwise, login may fail. Select the language and the server based on the actual situation. 209 10.1.5 Setting the Network Information The SEMS+ App allows connecting devices via Bluetooth or WiFi and configuring network parameters to realize remote monitoring or management. NOTICE The device name varies depending on the inverter model or smart dongle model. • Wi-Fi/LAN Kit, Wi-Fi Kit, Wi-Fi Box: Solar-WiFi*** • WiFi/LAN Kit-20: WLA-*** • WiFi Kit-20: WFA-*** • Ezlink3000: CCM-BLE***, CCM-***, *** • 4G Kit-CN-G20/4G Kit-CN-G21: GSA-***; GSB-*** • AC Charger:*** 10.2 Managing the Account 210 10.2.1 Registering an Account Step 1: Tap Register to enter the account registration interface. Step 2: Select the account type based on your actual needs and tap Next. Step 3: Enter your account information based on the actual situation and tap Register to complete the registration. 10.2.2 Logging in to the App NOTICE • Register an account or obtain an account from your dealer before logging in. • Check and manage power station after logging in. The actual interface takes precedence. Step 1: Enter the username and password, read, and agree to the login agreement. Tap Log In. 211 10.2.3 Switching Accounts Step 1: Go to My tab, and tap Log Out > Log with Another Account. Step 2: Select an already added account or add a new account based on actual needs. 10.2.4 Deleting an Account 212 Step 1: Go to My tab and tap Account&Security. Step 2: Tap Close Account, input the account password, and Submit. 10.2.5 Account Permission Descriptions The SEMS+ App supports various types of accounts with different permissions. Refer to the table below for details. Primary menu Login & Register Submenu Third-Level Fourth-Level Fifth-Level Menu Menu Menu Permissions Administrator, - - - - Technician, Browser, End User, Visitor Monitoring Information Administrator, - - - Technician, Browser, End User, Visitor Overview Administrator, Create Station - - - Technician, End User and Visitor 213 Station Administrator, Station List - - - Technician, Browser, End User, Visitor Administrator, Monitoring - - Technician, Browser, End User, Visitor Add Device - Search Device Device List Station Details Administrator, Technician, Browser, End User, Visitor Administrator, Device Technician, End User Administrator, Technician, End User Delete Administrator, Device Technician, End User Device Administrator, Monitoring Technician, Browser, Info End User, Visitor Device Device Details Technician, End User Replace Edit Device Device Administrator, Remote Control Device Remote Upgrade Administrator, Technician, End User Administrator, Technician Administrator, Alarms - - Technician, Browser, End User, Visitor Station Edit Station Configuratio Delete n Station Replacement 214 - - Administrator, Technician, End User Administrator, Technician, End User Administrator, History Technician, Browser, End User User Information - Home Configuratio Administrator, Technician, End User Administrator, - n Technician, Browser, End User, Visitor Administrator, Create Station - - - Technician, End User and Visitor Alarm - - - - Administrator, Technician, Browser Administrator, Warranty - - Technician, Browser, End User, Visitor Report Center Services GoodWe News Announceme nts Services Administrator, - - Technician, Browser, End User Administrator, - - Technician, Browser, End User, Visitor Administrator, - - Technician, Browser, End User, Visitor Administrator, Community - - Technician, Browser, End User, Visitor Create Station Administrator, - - Technician, End User and Visitor Tools Administrator, Network Link - - Technician, Browser, End User, Visitor DNSP - - 215 Administrator, Technician, Browser, End User, Visitor Administrator, Help - - - Technician, Browser, End User, Visitor Administrator, User Profile - - - Technician, Browser, End User, Visitor User Information Administrator, - - - Technician, Browser, End User, Visitor Administrator, Setting - - - Technician, Browser, End User, Visitor Administrator, Email - - Technician, Browser, End User, Visitor Administrator, My Account Security Password Secondary Close Account Remote Management - Technician, Browser, End User, Visitor Account Auth - Control Auth Monitoring Auth - - Administrator, Technician, Browser Administrator, - - Technician, Browser, End User, Visitor Administrator, - - Technician, Browser, End User, Visitor - - End User Administrator, Apps - - - Technician, Browser, End User, Visitor About - - - 216 Administrator, Technician, Browser, End User, Visitor Administrator, Logout - - Technician, Browser, End User, Visitor Logout Login anther Account Administrator, - - Technician, Browser, End User, Visitor 10.3 Setting the Network Information The SEMS+ App allows connecting devices via Bluetooth or WiFi and configuring network parameters to realize remote monitoring or management. NOTICE The device name varies depending on the inverter model or smart dongle model. • Wi-Fi/LAN Kit, Wi-Fi Kit, Wi-Fi Box: Solar-WiFi*** • WiFi/LAN Kit-20: WLA-*** • WiFi Kit-20: WFA-*** • Ezlink3000: CCM-BLE***, CCM-***, *** • 4G Kit-CN-G20/4G Kit-CN-G21: GSA-***; GSB-*** • AC Charger:*** 10.3.1 Connecting via Bluetooth NOTICE • Before connecting, ensure: Your phone’s Bluetooth is enabled. The device is powered on and communicating properly. • The App interface and parameters may vary depending the device type or smart dongle model. The actual interface takes precedence. Step 1: Open the app and select Network Link on the homepage or in the Service interface. Step 2: Tap Bluetooth and select the device by the serial number. 217 Step 3 : If prompted, log into the App according to your role and enter the password. Default password: 1234. If no login prompt appears, you will directly enter the communication settings interface. Step 4: (Optional) Enable Bluetooth Stays ON if required. Otherwise, the Bluetooth signal will turn off after the connection. Step 5: Set the WLAN or LAN parameters based on actual situation. Tap Save to complete the settings. Tap WLAN Detetion to check the communication status. Step 6: (Optional) Tap Login Password Change to input a new password, and Save. 218 219 No. Parameters Privacy&Security 1 Bluetooth Stays ON Description Enable the function, the bluetooth of the device will be contentious on to keep connected to SEMS+. Otherwise, the bluetooth will be off in 5 minutes. WLAN/LAN 2 WLAN 3 Name 4 Encryption Method 5 Password 6 DHCP Automatic Obtain 7 IP Address 8 Subnet Mask 9 Gateway Address 10 DNS Server Enable or disable WLAN. Select the name of the router network to be used. Enable DHCP when the router is in dynamic IP mode. Disable DHCP when a switch is used or the router is in static IP mode. Do not configure the parameters when DHCP is enabled. Configure the parameters according to the router or switch information when DHCP is disabled. 10.3.2 Connecting via WiFi NOTICE • Before connecting, ensure: Your phone’s Bluetooth is enabled. The device is powered on and communicating properly. • The App interface and parameters may vary depending the device type or smart dongle model. The actual interface takes precedence. Step 1: Open the WiFi setting on the phone and connect to the inverter’s WiFi signal (Solar-WiFi***). Default password: 12345678 Step 2: Open the app and select Network Link on the homepage or in the Service interface. Step 3: Tap WLAN and select the device by the serial number. Step 4: Modify the WiFi hotspot password if needed. If changed, reconnect to the inverter’s WiFi signal using the new password. Step 5: Set the WLAN or LAN parameters based on actual situation. Tap Save to complete the settings. Tap WLAN Detetion to check the communication status. 220 No. Parameters Privacy&Security Login 1 Password Change WLAN/LAN 2 Internet Access Port Description Modify the WiFi hotspot password if needed. If changed, reconnect to the inverter’s WiFi signal using the new password. Set the communication mode as Wi-Fi or LAN based on actual needs. 221 No. 3 Parameters Name 4 Encryption Method 5 Password 6 DHCP Automatic Obtain 7 IP Address 8 Subnet Mask 9 Gateway Address 10 DNS Server Description Select the name of the router network to be used. Enable DHCP when the router is in dynamic IP mode. Disable DHCP when a switch is used or the router is in static IP mode. Do not configure the parameters when DHCP is enabled. Configure the parameters according to the router or switch information when DHCP is disabled. 10.4 Checking Station Information 10.4.1 Checking Overview Information of All Stations After logging in, you can view an overview of all stations linked to your account from the homepage. Or sort the list of all power stations through different sorting and filtering conditions on the power station page to view the detailed information of the power stations. 222 No. Description Displays the overall generation information of all stations, including: Generation 1 Today, Generation This Month, Generation This Year, and Generation Lifetime. Generation This Year will not be displayed if the station amount exceeds 10. Displays the total installed capacity and the working status of the stations. Working 2 status: Running, Waiting, Offline, and Faulted. The stations status is running only when all the devices of the station are working properly. Displays statistical chart of Generation Today, This Year, and Lifetime.Or displays 3 comparison chart comparing current and past generation. Tap to expand the chart. 4 5 Displays environmental contributions like CO₂ Reduction, Trees Stationed Equivalent, and Standard Coal Saved. Creating a New Station 223 No. Description 6 Searching Stations Enter the device SN, power station name or email address to quickly search for the corresponding power station. 7 Power station operation status. Display the current operation status of power stations and the number of power stations operating in each status. Tap the operation status to filter power stations in the corresponding operation status. 8 • Set KPI indicators displayed in the power station list: Current Power, Rev. Today, Rev. Total, Gen. Today, Gen. Total • Set the sorting method of the power station list: By Default, By Capacity • Set the display mode of the power station list: Station Card, Station List • Set the filtering conditions for the power station list: Scope, Category, Capacity 9 Power station list. Tap the power station name to view the detailed information of the power station. The displayed content varies depending on the station type. The actual interface takes precedence 10.4.2 Checking Detailed Information of Single Station Step 1: Enter the device SN, power station name or email address to quickly search for the corresponding power station. Step 2: Tap the power station name to enter the power station details page. 224 10.4.2.1 Checking Detailed Information of Power Station (Traditional Mode) 225 No. Description 1 The current name of the power station. 2 Favoriting a Station 3 Configuring Station Information. Supported functions: Configure basic information of the power station, modify user information, add power station photos, set PV module layout, etc. 4 Displays current power station operation information in chart form, such as energy flow diagrams, power generation, load power consumption, AC output, and other information. 5 • Device List Displays devices in the current power station, such as inverters, batteries, data collectors, charging piles, etc. • Tap the device card to view detailed device information. 6 Alarm information. 10.4.3 Checking Alarm Information 10.4.3.1 Checking Alarm Information of All Power Stations Step 1 Tap Alarms tab to enter the alarm page. Step 2 (optional) Use the search bar to locate alarms by station name or device serial number. Step 3 Select the alarm to view detailed information. 226 10.4.3.2 Checking Detailed Information of Current Power Station (Traditional Mode) Step 1: If there are multiple power stations, tap the power station name to enter the power station details page. Step 2: Tap Alarms to enter the alarm page to view alarm details. Tap alarm information based on actual needs. 227 to filter 10.4.3.3 Checking Alarm Information of Current Devices Step 1: If there are multiple power stations, tap the power station name to enter the power station details page. Step 2:Select a device from the device list and enter the device details page. If there are alarms, the device details page allows direct viewing of the 10 latest ongoing alarms. 228 10.4.4 Checking Station Reports Viewing Reports Step 1: Tap Service > Report Center. Step 2: Select a time period, search for the desired station, and tap the station name to view the report center. Tap > Export to download the report if needed. 229 Viewing Bills Step 1: Tap Service > Report Center. 230 Step 2: Search for the desired station. Find the station, swipe left and tap billing details of the month. to view 10.5 Managing Stations 10.5.1 Creating a Station Step 1: Tap on overview or station page, or tap Create Station on service page. Step 2: Enter station information on theCreat Station page. Step 3: Tap Save&Exit to complete creating a station, without devices added. Or tap Save&Continue to add devices. Support adding multiple devices. 231 10.5.2 Configuring Station Information NOTICE The configuration information of the station can be updated as needed. When the information filled in is inconsistent with the actual situation of the power station, the actual situation of the power station shall prevail. 232 Step 1: (Optional) Select the station to be updated from the station list. Step 2: Tap > Basic Information to check the basic information. Step 3: Tap to modify the information, and tap Confirm to save the changes. 10.5.3 Managing Station Visitors SEMS+ App allows users to add visitors to the power station and view basic information. Visitors have limited access and cannot view all information. Step 1: (Optional) Select the station to be updated from the station list. Step 2: Tap > User Information > Add. Step 3: Input the visitor's information and tap Confirm. 233 To delete a visitor, go to the User Information page, select the visitor, and tap Delete. 10.5.4 Managing Station Photos Adding photos to a station helps users find what they need faster. Step 1: (Optional) Select the station to be updated from the station list. Step 2: Tap > Station Photos > Add. Step 3: Follow the prompts to add photos by Take a Photo or Choose from Album. 234 To delete a photo, follow the steps below. 10.5.5 Configuring the Page Information Change what's shown on the station details page, such as showing, hiding, or repositioning the Energy Flow Chart. Step 1: (Optional) Select the station to be updated from the station list. Step 2: Tap > Home Configuration on the station page. Step 3: Refer to the on-screen prompts to select the information content to be displayed, or adjust the display order of various information based on actual needs. 235 10.5.6 Set PV Module Layout Set the PV Layout Design parameters based on the actual conditions of PV modules. Step 1: (Optional) Select the station to be updated from the station list. 236 Step 2: Tap > PV Layout Design to enter the interface. Step 3: Tap Row/Column ,and set the arrangement of modules in each row and each column based on the actual installation of PV modules. Step 4: Tap Array Name to enter the Array Settings interface, and set the name, angle, and orientation information of the PV array based on the actual situation. 10.5.7 Deleting a Station NOTICE For station visitors, deleting a station means unbinding it from their account. Step 1:(Optional) If there are multiple power stations, tap he power station name to enter the power station details page. Step 2:Tap on the station page. Step 3: TapDelete and Confirm to delete the station. 237 10.5.8 Favoriting a Station To favorite a station, tap the star icon to unfavorite it. next to the station name. Tap the icon again Tap and Select Favorited in the filtering Scope to display all the favorited power stations. 238 10.6 Managing Devices 10.6.1 Adding a Device NOTICE • Supported device types may vary based on the station type. • If the environmental monitor is connected to a smart logger, add the environmental monitor to the station and view the its data. Step 1: Select a station from the station list. Step 2: Tap Device > to enter the device addition interface. Step 3:Select the type of device to add. Step 4: Follow the instructions to scan or manually input device information. To add the scanned devices, choose devices from the scanned device list. To manually add a device, scan the device SN code or input required device information. To add multiple devices, repeat the steps as needed. Step 5: When manually adding devices, if you need to add multiple devices, return to the power station details page and repeat steps 3 and 4. 239 240 10.6.2 Editing Device Information The device name can be modified. Step 1:(Optional) If there are multiple power stations, tap he power station name to enter the power station details page. Step 2:Tap Device to enter the device page. Select the device and swipe left, tap . Step 3: Input new device name and tap Submit. 10.6.3 Deleting a Device Step 1:(Optional) If there are multiple power stations, tap he power station name to enter the power station details page. Step 2:Tap Device to enter the device page. Select the device and swipe left, tap . Step 3:: Read the prompt and tap OK to delete the device. 241 10.6.4 Upgrade the Firmware Step 1: (Optional) Select the station to be updated from the station list. Step 2: Tap Device to open the device details page and select the device to be upgraded. Step 3:Tap the device serial number to enter the Firmware Version page. If the upgrade is available, tap Upgrade and follow the instructions. Tap to find the upgrade history. 242 10.7 Managing Device Remotely 243 NOTICE • Set the device parameters via SEMS+ App after creating a plant and adding devices to it. • Before setting any parameters, read through user manual of the App and the inverter or charger to learn the product functions and features. Incorrectly configured parameters, such as grid settings or start/stop commands, may result in devices failing to connect to the grid, potentially affecting power generation. • lOnly trained professionals familiar with local regulations and electrical systems should perform parameter settings. • Different account permissions allow for remote setting of different parameters. The interface will be displayed based on the actual account in use, and please refer to the actual interface. • The setting page varies depending on accounts type and device model. 10.7.1 Configuring Hybrid Inverter Parameters Step 1: (Optional) Select the station to be updated from the station list. Step 2: Tap Device to enter the device page and choose the device to be configured. Step 3: Tap , read the prompts and set parameters as needed. 244 No. Parameters Description 1 Safety Set the safety country in compliance with local grid standards and application scenario of the inverter. 2 Battery Model Set the model of the connected battery. 3 Depth of Discharge (OnGrid) The maximum depth of discharge of the battery when the system is working on-grid. Battery 245 No. Parameters Description 4 Depth of Discharge (OffGrid) The maximum depth of discharge of the battery when the system is working off-grid. 5 Backup SOC Holding 6 SOC Protection The battery will be charged to preset SOC protection value by utility grid or PV when the system is running on-grid. So that the battery SOC is sufficient to maintain normal working when the system is off-grid. Start battery protection when the battery capacity is lower than the Depth of Discharge. 246 No. Parameters Description When a battery with heating function is connected, this option will be displayed on the interface. After enabling the battery heating function, when the battery temperature does not support battery startup, PV power generation or purchased electricity will be used to heat the battery. Heating modes: • GW5.1-BAT-D-G20/GW8.3-BAT-D-G20 Low-power mode: Maintain the minimum power input capability of the battery. It turns on when the temperature is below -9℃ and turns off when the temperature is -7℃ or higher. Medium-power mode: Maintain moderate power input capability of the battery. It turns on when the temperature is below 6℃ and turns off when the temperature is 8℃ or higher. High-power mode: Maintain high power input capability of the battery. It turns on when the temperature is below 11℃ and turns off when the temperature is 13℃ or higher. • GW14.3-BAT-LV-G10 Low-power mode: Maintain the minimum power input capability of the battery. It turns on when the temperature is below 5℃ and turns off when the temperature is 7℃ or higher. Medium-power mode: Maintain moderate power input capability of the battery. It turns on when the temperature is below 10℃ and turns off when the temperature is 12℃ or higher. High-power mode: Maintain high power input capability of the battery. It turns on when the temperature is below 20℃ and turns off when the temperature is 22℃ or higher. ○ ○ 7 Battery Heating ○ ○ ○ ○ 8 Daily Heating Period Set the battery heating time period based on actual needs. 247 No. Parameters 9 Battery Wake-up After being enabled, the battery can be woken up when it shuts down due to undervoltage protection. Battery Breathing Light • Only applicable to the ESA 3-10kW inverter series. Set the blinking duration of the device's breathing light. Options available: Always on, Always off, 3min. • The default mode is to stay on for three minutes after power-on and then turn off automatically. 10 Description Mode Set the working mode based on actual needs. • Self-use mode: Back-up mode: The back-up mode is mainly applied to the scenario where the grid is unstable ¡When the grid is disconnected, the inverter turns to offgrid mode and the battery will supply power to the load; when the grid is restored, the inverter switches to on-grid mode. Eco mode: It is recommended to use economic mode in scenarios when the peak-valley electricity price varies a lot. Select Economic mode only when it meets the local laws and regulations. Set the battery to charge mode during Vally period to charge battery with grid power. And set the battery to discharge mode during Peak period to power the load with the battery. • Smart charging: In some countries/regions, the PV power feed into the utility grid is limited. Select Smart Charging to charge the battery using the surplus power to minimize PV power waste. • Peak shaving mode:Peak shaving mode is mainly applicable to peak power limited scenarios. When the total power consumption of the load exceeds the power consumption quota in a short period of time, battery discharge can be used to reduce the power exceeding the quota. ○ ○ 11 Working Mode 248 No. Parameters Description 12 On-Grid Power Limitation Enable On-Grid Power Limitation when power limiting is required by local grid standards and requirements. 13 Maximum OnGrid Output Power Set the value based on the actual maximum power feed into the utility grid. 14 Power Factor 15 Q(U) 16 COS(φ) 17 P(F) Set the power factor based on actual needs. Enable Q(U) Curve when it is required by local grid standards and requirements. Enable Cosφ Curve when it is required by local grid standards and requirements. Enable P(F) Curve when it is required by local grid standards and requirements. Others 18 Backup Supply 19 Shadow Scan After enabling Backup Supply, the battery will power the load connected to the BACK-UP port of the inverter to ensure Uninterrupted Power Supply when the power grid fails. Enable Shadow Scan when the PV panels are severely shadowed to optimize the power generation efficiency. 249 11 Maintenance 11.1 Power Off the System DANGER • Power off the equipment before operations and maintenance. Otherwise, the equipment may be damaged or electric shocks may occur. • Delayed discharge. Wait until the components are discharged after power off. • Push the air switch to restart the battery. • Strictly follow the power off requirements to avoid damaging the system. NOTICE To ensure effective protection, the cover of the battery system switch should remain closed. Fasten the cover with screws if the switch is not to be used for a long-term period. Power down 250 1. Turn off the ON-GRID circuit breaker. 2. Turn off the BACK-UP circuit breaker. 3. Press and hold any battery multifunction button for 5 seconds to power down the battery system. If the system contains multiple batteries, this operation will power down all batteries simultaneously, eliminating the need for individual operations. Finally, turn the battery system switch to the OFF position. 4. Turn off the DC switch of the inverter. (Optional) Set the manual switch to position A. 11.2 Removing the Equipment DANGER 251 • Make sure that the equipment is powered off. • Wear proper PPE during operations. • Please use standard disassembly tools when removing wiring terminals to avoid damaging the terminals or equipment. • Unless otherwise specified, the dismantling process of the equipment is in reverse order to the installation process, and it will not be further elaborated in this document. 1. Power off the System. 2. Label the cables connected in the system with tags indicating the cable type. 3. Disconnect the connecting cables of the inverter, battery, and smart meter in the system, such as DC cables, AC cables, communication cables, and PE cables. 4. Remove equipment such as the smart dongle, inverter, battery, and smart meter. 5. Properly store the equipment and ensure that the storage conditions meet the requirements if it needs to be put into use later. 11.3 Disposing of the Equipment If the equipment cannot work anymore, dispose of it according to the local disposal requirements for electrical equipment waste. The equipment cannot be disposed of together with household waste. 11.4 Routine Maintenance WARNING • Contact after-sales service for help if you find any problems that may influence the battery or the hybrid inverter. Disassemble without permission is strictly forbidden. • Contact after-sales service for help if the copper conductor is exposed. Do not touch or disassemble privately because high voltage danger exists. • In case of other emergencies, contact the after-sales service as soon as possible. Operate following the instructions or wait for the after-sales service personnel. 252 Maintainin g Item Maintaining Method Maintainin g Period Maintaining Purpose System Cleaning Check the heat sink, air intake, and air outlet for foreign matter or dust. Check whether the installation space meets requirements and whether there is any debris around the device. Once 6 months Prevent heat dissipation failures. Once 6-12 months Ensure that the equipment is installed securely. Once 6-12 months Confirm the reliability of electrical connections. Once a year Confirm that the machine seal and waterproof performance are intact. Once/15 days Protect the battery's lifespan. System installation Electrical connection Sealing Battery maintenanc e Check whether the equipment are installed securely and whether the screws are installed tightly. Check whether the equipment is damaged or deformed. Check whether the cables are securely connected. Check whether the cables are broken or whether there is any exposed copper core. Check whether all the terminals and ports are properly sealed. Reseal the cable hole if it is not sealed or too big. If the battery is not used for a long time or is not fully charged, it is recommended to charge the battery regularly. 11.5 Fault 11.5.1 Viewing Fault/Alarms Information All fault and alarm details for the energy storage system are displayed in the [SolarGo App]and [SEMS+ APP].If your product malfunctions and you do not see the relevant fault information in the [SolarGo App]and [SEMS+ APP].Please contact the after-sales service center. 253 • SolarGo App Through[Home] > [Parameters] > [Alarms], View the alarm information of the energy storage system. • SEMS+ APP 1. Open the SEMS+ App and log in with any account. 2. All power station fault information can be viewed through the Power Plant >Alarm. 3. Click on the specific fault name to view detailed information about the fault: [time of occurrence], [possible cause], and [solution]. 11.5.2 Fault Information and Troubleshooting Perform troubleshooting according to the following methods. Contact the after-sales service if these methods do not work. Collect the information below before contacting the after-sales service, so that the problems can be solved quickly. 1. Product information like serial number, software version, installation date, fault time, fault frequency, etc. 2. Installation environment, including weather conditions, whether the PV modules are sheltered or shadowed, etc. It is recommended to provide some photos and videos to assist in analyzing the problem. 3. Utility grid situation. If unlisted problems occur in the system, or if following the instructions does not stop the problem or abnormality, stop operating the system immediately and contact your dealer immediately. 254 No. 1 Fault Unable to search for the wireless signal of the smart dongle. Solutions/measures to address the issue 1. Please ensure that no other devices are connected to the smart dongle's wireless signal. 2. Please ensure that the SolarGo app has been updated to the latest version. 3. Please ensure that the smart dongle is powered on properly, and the blue indicator light is blinking or steady on. 4. Ensure that the smart device is within the communication range of the smart dongle. 5. Refresh the device list in the app. 6. Restart the inverter. 2 Unable to connect to the wireless signal of the smart dongle. 1. Please ensure that no other devices are connected to the smart dongle's wireless signal. 2. Restart the inverter or smart dongle, and try to reconnect to the wireless signal of the smart dongle again. 3. Ensure successful pairing of Bluetooth. 3 Cannot find router SSID. 1. Put the router nearer to the Smart Dongle. Or add a WiFi relay device to enhance the WiFi signal. 2. Reduce the number of devices connected to router. 4 After completing all configurations, the Smart Dongle fails connecting to the router. 1. Restart the inverter. 2. Check if the SSID, encryption method and password on WiFi configuration page are the same with that of Router. 3. Restart the router. 4. Put the router nearer to the Smart Dongle. Or add a WiFi relay device to enhance the WiFi signal. 255 No. 5 Fault After completing all configurations, the Smart Dongle fails connecting to the router. Solutions/measures to address the issue Restart the router and the inverter. 11.5.2.1 Inverterfault No. 1 2 fault name GridPower Outage Grid Overvoltage fault cause 1. Utility grid power outage. 2. AC line or AC Switch disconnected. Utility gridvoltage exceeds the allowable range, or the high voltage duration surpasses the high voltage ride-through setting. Troubleshooting recommendation 1. The alarm automatically disappears after Grid connected recovery. 2. Check if the AC line or AC Switch is disconnected. 1. If it occurs occasionally, it may be due to a temporary abnormality in Utility grid. Inverter will resume normal operation after detecting that Utility grid is functioning properly, without requiring manual intervention. 2. If it occurs frequently, check whether Utility gridvoltage is within the allowable range. • If Utility gridvoltage exceeds the permissible range, please contact the 256 No. fault name fault cause Troubleshooting recommendation local power operator. • If the Utility gridvoltage is within the allowable range, it is necessary to modify the InverterUtility grid overvoltage Protection point after obtaining consent from the local power operator.HVRTEnable or disable the Utility grid overvoltage Protection function. 3. If the issue persists for an extended period, please check whether the breaker on the AC side and the output cables are properly connected. 257 No. fault name fault cause Troubleshooting recommendation 1. If it occurs occasionally, it may be due to a temporary abnormality in Utility grid. Inverter will resume normal operation after detecting that Utility grid is normal, without requiring manual intervention. 2. If it occurs frequently, check whether the Utility gridvoltage is within the allowable range. 3 Grid Undervoltage Utility gridvoltage is below the permissible range, or the duration of low voltage exceeds the low voltage ridethrough setting. • If Utility gridvoltage exceeds the permissible range, please contact the local power operator. • If the Utility gridvoltage is within the allowable range, it is necessary to modify the InverterUtility grid undervoltage Protection point after obtaining consent from the local power operator.LVRTEnable or disable the Utility grid under-voltage Protection function. 3. If the issue persists for an extended period, please check whether the breaker on the AC side and the output cables are properly connected. 258 No. fault name fault cause Troubleshooting recommendation 1. If it occurs occasionally, it may be due to a temporary abnormality in Utility grid. Inverter will resume normal operation after detecting that Utility grid is functioning properly, without requiring manual intervention. 2. If it occurs frequently, check whether Utility gridvoltage is within the allowable range. 4 Grid Rapid Overvoltage Utility gridvoltage detection shows abnormality or ultrahigh voltage triggers fault. • If Utility gridvoltage exceeds the permissible range, please contact the local power operator. • If the Utility gridvoltage is within the allowable range, it is necessary to modify the InverterUtility grid undervoltage Protection point after obtaining consent from the local power operator.LVRTEnable or disable the Utility grid under-voltage Protection function. 3. If the issue persists for an extended period, please check whether the AC-side breaker and output cables are properly connected. 259 No. 5 fault name Grid 10min Overvoltage fault cause In10minThe sliding average of Utility gridvoltage exceeds the safety regulation limits. 260 Troubleshooting recommendation 1. If it occurs occasionally, it may be due to a temporary anomaly in Utility grid. Inverter will resume normal operation upon detecting that Utility grid is functioning properly, without requiring manual intervention. 2. Check if Utility gridvoltage is operating at a high voltage for an extended period. If this occurs frequently, verify whether Utility gridvoltage is within the permissible range. • If Utility gridvoltage exceeds the permissible range, please contact the local power operator. • If the Utility gridvoltage is within the allowable range, it is necessary to obtain approval from the local power operator before modifying the Utility grid.10minOvervoltage Protection point. No. 6 fault name Grid Over frequency fault cause Utility grid anomaly: Utility grid actual Frequency exceeds local Utility grid standard requirements. 261 Troubleshooting recommendation 1. If it occurs occasionally, it may be due to a temporary abnormality in Utility grid. Inverter will resume normal operation after detecting that Utility grid is functioning properly, without requiring manual intervention. 2. If it occurs frequently, check whether Utility grid Frequency is within the allowable range. • If the Utility gridFrequency exceeds the permissible range, please contact the local power operator. • If the Utility gridFrequency is within the allowable range, it is necessary to modify the Utility grid over-frequency Protection point after obtaining consent from the local power operator. No. 7 fault name Grid Underfrequency fault cause Utility grid anomaly: Utility grid actual Frequency is lower than local Utility grid standard requirement. 262 Troubleshooting recommendation 1. If it occurs occasionally, it may be due to a temporary abnormality in Utility grid. Inverter will resume normal operation after detecting that Utility grid is functioning properly, without requiring manual intervention. 2. If it occurs frequently, please check whether Utility grid and Frequency are within the allowable range. • If Utility gridFrequency exceeds the permissible range, please contact the local power operator. • If the Utility gridFrequency is within the allowable range, it is necessary to modify the Utility grid over-frequency Protection point after obtaining consent from the local power operator. No. 8 fault name Grid Frequency Unstable fault cause Troubleshooting recommendation 1. If it occurs occasionally, it may be due to a temporary abnormality in Utility grid. Inverter will resume normal operation after detecting that Utility grid is functioning properly, without requiring manual intervention. 2. If it occurs frequently, check whether Utility grid and Frequency are within the allowable range. Utility grid anomaly: The actual Frequency variation rate does not comply with the local Utility grid standard. • If the Utility grid Frequency exceeds the permissible range, please contact the local power operator. • If the Utility gridFrequency is within the allowable range, please contact your dealer or after-sales service center. 263 No. 9 fault name Grid Phase Unstable fault cause Utility grid anomaly: Utility grid voltage phase change rate does not comply with local Utility grid standard. 264 Troubleshooting recommendation 1. If it occurs occasionally, it may be due to a temporary abnormality in Utility grid. Inverter will resume normal operation after detecting that Utility grid is functioning properly, without requiring manual intervention. 2. If it occurs frequently, check whether the Utility grid Frequency is within the allowable range. • If Utility gridFrequency exceeds the permissible range, please contact the local power operator. • If Utility gridFrequency is within the allowable range, please contact your dealer or after-sales service center. No. 10 11 fault name Anti-islanding Protection LVRT Undervoltage fault cause Utility grid has been disconnected, maintaining Utility grid voltage due to the presence of load. According to safety regulation Protection, on-grid has been stopped. Utility grid anomaly: Utility gridvoltage anomaly duration exceeds the specified high-low transition time. 265 Troubleshooting recommendation 1. If it occurs occasionally, it may be due to a temporary abnormality in Utility grid. Inverter will resume normal operation after detecting that Utility grid is functioning properly, without requiring manual intervention. 2. If it occurs frequently, check whether Utility gridFrequency is within the allowable range. • If Utility gridFrequency exceeds the allowable range, please contact the local power operator. • If Utility gridFrequency is within the allowable range, please contact your dealer or after-sales service center. No. 12 13 fault name HVRT Overvoltage Grid Wave form Abnormal Grid Phase Loss 14 fault cause Troubleshooting recommendation Utility grid anomaly: Utility gridvoltage anomaly duration exceeds the specified high-low transition time. 1. If it occurs occasionally, it may be due to a temporary abnormality in Utility grid. Inverter will resume normal operation after detecting that Utility grid is normal, without requiring manual intervention. 2. If it occurs frequently, please check whether Utility grid, voltage, and Frequency are within the allowable range and stable. If not, please contact the local power operator; if yes, please contact your dealer or after-sales service center. Utility grid anomaly: Utility gridvoltage detection triggered fault due to abnormality. Utility grid anomaly: Utility gridvoltage has a single-phase dip. 266 No. 15 16 17 fault name Grid Voltage Imbalance Grid Phase Sequence Abnormal Grid Rapid Shutdown Protection fault cause Troubleshooting recommendation Phase Utility grid has excessive deviation from voltage. 1. If it occurs occasionally, it may be due to a temporary abnormality in Utility grid. Inverter will resume normal operation after detecting that Utility grid is normal, without requiring manual intervention. 2. If it occurs frequently, please check whether Utility grid, voltage, and Frequency are within the allowable range and stable. If not, please contact the local power operator; if yes, please contact your dealer or after-sales service center. Inverter and Utility grid wiring abnormality: wiring not in positive sequence 1. Check whether the wiring of Inverter and Utility grid is in positive sequence. After the wiring is corrected (e.g., by swapping any two live wires), fault will automatically disappear. 2. If the fault persists after correct wiring, please contact the distributor or GoodWe Customer Service Center. Quickly shut down the output upon detecting the Grid disconnected operating condition. 1. Grid connected automatically disappears after fault is restored 267 No. 18 fault name Neutral LineLoss (Split Grid) Troubleshooting recommendation fault cause Phase separation Utility grid neutral line loss 1. The alarm automatically disappears after Grid connected recovery. 2. Check if the AC line or AC Switch is disconnected. Enable off-grid function 19 EMS/Forced off-grid EMSIssue forced offgrid command, but the off-grid function is not enabled. 20 Passive Islanding Detection/Passive Anti-islanding Protection - - Grid Type Abnormal Actual Grid type (two-phase or splitphase) does not match the set safety regulations. Switch the corresponding safety regulations according to the actual Grid type. During operation, the input-to-ground insulation resistance becomes low. 1. If it occurs occasionally, it may be caused by temporary abnormalities in the external circuit. It will return to normal operation after fault is cleared, without requiring manual intervention. 2. If it occurs frequently or cannot be restored for a long time, please check whether the PV String ground impedance is too low. 21 22 GFCI Protection (30mA) 268 No. 23 24 fault name GFCI Protection (60mA) GFCI Protection (150mA) fault cause Troubleshooting recommendation During operation, the input-to-ground insulation resistance becomes low. 1. If it occurs occasionally, it may be caused by temporary abnormalities in the external circuit. It will return to normal operation after fault is cleared, without requiring manual intervention. 2. If the issue occurs frequently or persists for an extended period, check whether the PV String ground impedance is too low. During operation, the input-to-ground insulation resistance becomes lower. 1. If it occurs occasionally, it may be caused by temporary abnormalities in the external circuit. It will return to normal operation after fault is cleared, without requiring manual intervention. 2. If the issue occurs frequently or cannot be resolved for an extended period, please check whether the PV String ground impedance is too low. 269 No. 25 26 fault name GFCI Protection (300mA) DCI Protection Level 1 fault cause Troubleshooting recommendation During operation, the input-to-ground insulation resistance becomes low. 1. If it occurs occasionally, it may be caused by temporary abnormalities in the external circuit. The system will resume normal operation after fault is cleared, without requiring manual intervention. 2. If the issue occurs frequently or cannot be resolved for an extended period, please check whether the PV String ground impedance is too low. The DC component of the inverter output current exceeds the safety regulations or the default allowable range of the machine. 1. If the abnormality is caused by an external fault, the Inverter will automatically resume normal operation after the fault disappears, without requiring manual intervention. 2. If this alarm occurs frequently and affects the normal power generation of the power station, please contact the dealer or GoodWe after-sales service center. 270 No. 27 28 fault name DCI Protection Level 2 Low Insulation Resistance fault cause Troubleshooting recommendation The DC component of the inverter output current exceeds the safety regulations or the default allowable range of the machine. 1. If the abnormality is caused by an external fault, the Inverter will automatically resume normal operation after the fault disappears, without requiring manual intervention. 2. If this alarm occurs frequently and affects the normal power generation of the power station, please contact the dealer or GoodWe after-sales service center. 1. PV String is shortcircuited to ground with Protection. 2. The environment of PV StringInstallation is consistently humid, and the line-toground insulation is poor. 3. Batteryport lineto-ground insulation resistance is low. 1. Check the impedance between PV String/Battery port and ground Protection. A resistance greater than 50kΩ is normal. If the measured resistance is less than 50kΩ, locate and rectify the short circuit point. 2. Check if the Inverter's PE cable is properly connected. 3. If it is confirmed that the impedance is indeed lower than the default value in rainy weather conditions, please reset the Inverter "insulation resistanceProtection point" via the SolarGo App. 271 No. fault name fault cause Troubleshooting recommendation In the Australian and New Zealand markets, when insulation resistancefault occurs, the following methods can also be used for alarm: Inverter. 1. Inverter is equipped with a buzzer, which will sound continuously for 1 minute when a fault occurs; if the fault is not resolved, the buzzer will sound again every 30 minutes. 2. If Inverter is added to the monitoring platform and the alarm notification method is configured, the alarm information can be sent to customers via email. 29 Grounding Abnormal 1. The PE cable of Inverter is not connected. 2. When the output of PV String is grounded, the output side of Inverter is not connected to an isolation transformer. 272 1. Please confirm whether the Inverter of PE cable is not properly connected. 2. In the scenario where the output of PV String is grounded, please confirm whether the output side of Inverter is connected to an isolation transformer. No. fault name L-PE Short Circuit 30 31 DCV Protection Level 1 fault cause Troubleshooting recommendation Output phase line toPELow impedance or short circuit Detect output phase line pairPEImpedance, find out Locations with low impedance and repair them. Abnormal load fluctuation 1. If the abnormality is caused by an external fault, the Inverter will automatically resume normal operation after the fault disappears, without requiring manual intervention. 2. If this alarm occurs frequently and affects the normal power generation of the power station, please contact the distributor or GoodWe after-sales service center. 273 No. 32 33 fault name DCV Protection Level 2 Hard Export Limit Protection fault cause Troubleshooting recommendation Abnormal load fluctuation 1. If the abnormality is caused by an external fault, the Inverter will automatically resume normal operation after the fault disappears, without requiring manual intervention. 2. If this alarm occurs frequently and affects the normal power generation of the power station, please contact the dealer or GoodWe after-sales service center. Abnormal load fluctuation 1. If the abnormality is caused by an external fault, the Inverter will automatically resume normal operation after the fault disappears, without requiring manual intervention. 2. If this alarm occurs frequently and affects the normal power generation of the power station, please contact the distributor or GoodWe after-sales service center. 274 No. 34 35 36 fault name Internal Comm Loss Multiple GFCI Failures Multiple AFCI Failures fault cause Reference specific subcode reason Troubleshooting recommendation Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. North American safety regulations require that after multiple fault, the system must not 1. Please check if the PV recover String ground impedance automatically and is too low. requires manual intervention or waiting.24hPostrecovery North American 1. After the machine is safety regulations reconnected, check if the require that after voltage current of each multiple fault, it circuit is abnormally reduced cannot automatically to zero. recover and must be manually restored or 2. Check if the DC-side terminal is securely wait.24hPostconnected. recovery 275 No. 37 38 39 fault name External Comm Loss Back-up Overload Output Back-up Output Overvoltage fault cause Troubleshooting recommendation Inverter external device communication lost, possibly due to peripheral power supply issues, Communication Protocols mismatch, or unconfigured corresponding peripherals. Judgment is made based on the actual model and detection enable bits; peripherals not supported by certain models will not be detected. 1. Prevent Inverter from continuous overload output. 1. Disconnect some off-grid loads to reduce the off-grid output Power of Inverter. 2. Prevent damage to the load caused by Inverter output overvoltage. 1. If it occurs occasionally, it may be caused by load switching and does not require manual intervention. 2. If it occurs frequently, please contact the dealer or GoodWe after-sales service center. 276 No. 40 41 fault name On-grid PWM Sync Fault External Box Failure fault cause Troubleshooting recommendation Abnormal occurrence in carrier synchronization ongrid 1Check if the synchronization line connection is normal. 2Check if the master-slave settings are normal. 3Disconnect the AC output side switch and the DC input side switch.5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Waiting for grid disconnectionBoxExc essive relay switching time 277 1. InspectionBoxIs it functioning properly; 2. InspectionBoxIs the communication wiring correct; No. fault name fault cause Troubleshooting recommendation 1. When the generator is not connected, ignore this fault; 42 Generator Failure 1. This fault will always be displayed when the generator is not connected. 2. During generator operation, failure to meet generator safety regulations will trigger this fault. 2. This fault is normal when the generator experiences fault. After the generator recovers, wait for a period of time, and the fault will automatically clear. 3. The fault will not affect the normal operation of the off-grid mode. 4. The generator and Utility grid are connected simultaneously and meet safety requirements. Utility grid takes priority for ongrid and will operate in the Utility grid on-grid state. 43 Inverter andSTSAbnormal connection cable Check Inverter andSTSIs the wiring sequence of the harness connections one-toone and sequentially corresponding? 44 CTConnection wire disconnected (Japanese safety regulation requirement) InspectionCTIs the wiring correct. External STS Failure CT Loss 278 No. 45 46 47 fault name Export Limit Protection Bypass Over Load Black Start Failure ParalellI/O Check Abnormal 48 49 Paralell CAN Comm Abnormal Paralell Grid Line Reversed 50 Troubleshooting recommendation fault cause 1. Check if there are any other error messages in Inverter. If so, perform 1. Grid targeted troubleshooting. disconnection due to 2. InspectionmeterIs the Inverter alarm connection reliable? 2. meterUnstable 3. If this alarm occurs communication frequently and affects the 3. Reverse power normal power generation flow condition of the power station, occurs please contact the distributor or GoodWe after-sales service center. - - - - Parallel communication cable is not securely connected or parallel operation issue.IOChip damage Parallel communication cable is not securely connected or some units are offline. Check if the parallel communication cable is securely connected, and then recheck.IOIs the chip damaged? If yes, replace it.IOChip. Check whether all machines are power on and if the parallel communication cables are securely connected. Some machines have the Utility grid line Reconnect the Utility grid reversed with other line. connections. 279 No. fault name Paralell Back-up LineReversed 51 52 53 54 55 Inverter SoftStart Failure Off grid AC Ins Volt High AC HCT Check Abnormal AC HCT Failure Troubleshooting recommendation fault cause Partial machinesbackupLine and other connections reversed reconnectionbackupLine. Inverter soft start failure during offgrid cold start Check whether the inverter module of the machine is damaged. - - AC sensor sampling anomaly detected HCTSensor abnormality detected 280 Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. No. 56 57 58 fault name GFCI HCT Check Abnormal GFCI HCT Failure Relay Check Abnormal fault cause Leakage current sensor sampling anomaly detected. Leakage current sensor is abnormal Relay abnormality, cause: 1Relay abnormality (relay short circuit) 2Relay sampling circuit abnormality. 3Abnormal AC measurement wiring (possible loose connection or short circuit) 281 Troubleshooting recommendation Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. fault cause Troubleshooting recommendation 1Relay abnormality (relay short circuit) 2Relay sampling circuit abnormality. 3Abnormal AC side wiring (possible loose connection or short circuit) Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. 1DC side connection terminal loose; 2DC side connection terminal loose contact; 3Core damage and poor contact 1After the machine is reconnected, check whether the voltage current of each circuit is abnormally reduced to zero. 2Check if the DC side terminal is securely connected. 61 1DC side connection terminal loose; 2DC side connection terminal loose contact; 3Core damage and poor contact 1After the machine is ongrid, check whether the voltage current of each circuit is abnormally reduced to zero. 2Check if the DC-side terminal is securely connected. 62 Possible causes: flashContent has changed;flashEnd of life 1. Upgrade to the latest version of the program 2. Contact the distributor or GoodWe after-sales service center. No. 59 60 fault name Relay Failure AFCI Failure (String 17~32) AFCI Failure (String 33~48) Flash R/W Abnormal 282 No. 63 64 65 fault name AFCI Failure (String 1~16) AFCI Failure Check AC Terminal Overtemperature fault cause Troubleshooting recommendation 1DC side connection terminal loose; 2DC side connection terminal loose contact; 3Core damage and poor contact 1After the machine is reconnected, check whether the voltage current of each circuit is abnormally reduced to zero. 2Check if the DC side terminal is securely connected. During the arc selfcheck process, the arc module failed to detect the arc fault. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. AC terminal temperature too high, possible causes: 1Inverter Installation Location not ventilated. 2Ambient temperature is too high. 3Internal fan operation abnormal. 283 No. 66 67 fault name Cabinet Overtemperature Inv Module Overtemperature fault cause Cavity temperature too high, possible causes: 1InverterInstallation Location not ventilated. 2Ambient temperature is too high. 3Internal fan operation abnormal. Inverter module temperature too high, possible causes: 1InverterInstallation Location is not ventilated. 2Ambient temperature is too high. 3Internal fan operation abnormal. 284 Troubleshooting recommendation 1Check if the ventilation of InverterInstallation Location is adequate and if the ambient temperature exceeds the maximum allowable range. 2If there is no ventilation or the ambient temperature is too high, please improve the ventilation and heat dissipation conditions. 3If ventilation and ambient temperature are normal, please contact the dealer or GoodWe after-sales service center. No. 68 69 fault name Boost Module Overtemperature AC Capacitor Overtemperature fault cause BoostModule temperature too high, possible causes: 1InverterInstallation Location is not ventilated. 2Ambient temperature is too high. 3Internal fan operation abnormal. Output filter capacitor temperature too high, possible causes: 1Inverter Installation Location is not ventilated. 2Ambient temperature is too high. 3Internal fan operation abnormal. 285 Troubleshooting recommendation No. 70 71 72 fault name Relay Failure 2 PV IGBT Short Circuit PV IGBT Open Circuit fault cause Troubleshooting recommendation Relay abnormality, cause: 1Relay abnormality (relay short circuit) 2Relay sampling circuit abnormality. 3Abnormal AC side wiring (possible loose connection or short circuit) Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Possible causes: 1. IGBTshort circuit 2Inverter sampling circuit abnormality 1. Software issue causing no wave transmission. 2. Drive circuit abnormality: 3. IGBTOpen circuit 286 Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. No. 73 74 75 76 fault name NTC Abnormal PWM Abnormal CPU Interrupt Abnormal Microelectronic Failure fault cause NTCTemperature sensor abnormality detected. PWMAbnormal waveform detected CPUInterruption anomaly Functional safety detects an anomaly. 287 Troubleshooting recommendation Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. No. fault name fault cause PV HCT Failure boostcurrent sensor anomaly 78 1. 5V Ref Abnormal Reference circuit 79 0. 3V Ref Abnormal Reference circuit 77 CPLD Version Error 80 81 CPLD Comm Failure CPLDVersion identification error CPLDandDSPCommu nication content error or timeout 288 Troubleshooting recommendation Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. No. 82 83 84 fault name Model Type Error SVG Precharge Failure SVG Mode PID Prevention Failure fault cause Regarding the fault of model identification error SVGPrecharge hardware failure 86 87 88 Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Contact the distributor or GoodWe after-sales service center. PIDPrevent hardware anomalies Contact the distributor or GoodWe after-sales service center. DSPSoftware version identification error Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. DSP Version Error 85 Troubleshooting recommendation BUS Overvoltage P-BUS Overvoltage N-BUS ervoltage 289 No. fault name Overvoltage(Slave CPU 1) 89 90 P-BUS Overvoltage (SlaveCPU 1) N-BUS Overvoltage (SlaveCPU 1) 91 92 93 BUS Overvoltage (SlaveCPU 2) fault cause BUSOvervoltage, possible causes: 1. PVvoltage too high 2InverterBUSSampli ng anomaly 3The poor isolation effect of the rearend double splitting leads to mutual interference between the two Inverter on-grid, causing one of them to report a DC overvoltage when Inverter on-grid. P-BUS Overvoltage (SlaveCPU 2) N-BUS Overvoltage (SlaveCPU 2) 94 290 Troubleshooting recommendation Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. No. 95 96 97 98 fault name fault cause Troubleshooting recommendation 1. Software issue causes inverter drive to shut down earlier than flyback drive. 2. Inverter drive circuit abnormality causing failure to turn on. 3. PVvoltage too high 4. MosSampling anomaly Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. 1. Hardware damage In case of occurrenceBUSAfter a fault short circuit, the Inverter remains in an off-grid state. Please contact the dealer or GoodWe after-sales service center. P-BUS Overvoltage (CPLD) N-BUS Overvoltage (CPLD) MOS Continuous Overvoltage Bus Short Circuit 291 No. 99 100 101 fault name Bus Sample Abnormal DC Sample Abnormal PV Input Overvoltage fault cause 1. BusSampling hardware 1. Bus sampling hardware 2. Batteryvoltage Sampling Hardware fault 3. Dcrly relay PVInput voltage is too high, possible causes: Incorrect PV array configuration, with too many PV Battery panels connected in series in the string, resulting in the string's open-circuit voltage exceeding the maximum operating voltage of the Inverter. 292 Troubleshooting recommendation Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Check the series configuration of the corresponding PV array strings to ensure that the open-circuit voltage of the strings does not exceed the maximum working voltage of Inverter. Once the PV array is correctly configured, the Inverter alarm will automatically disappear. No. fault name fault cause 102 PV Continuous Hardware Overcurrent 1. Unreasonable module configuration 2. Hardware damage 103 PV Continuous Software Overcurrent 1. Unreasonable module configuration 2. Hardware damage 104 FlyCap Software Overvoltage Flying capacitor overvoltage, possible causes: 1. PVvoltage too high 2Inverter flying capacitor voltage sampling anomaly; 105 Flying capacitor overvoltage, possible causes: 1. PVvoltage too high 2Inverter flying capacitor voltage sampling anomaly; 106 Flying capacitor undervoltage, possible causes: 1. PVEnergy deficiency; 2Inverter flying capacitor voltage sampling anomaly; FlyCap Hardware Overvoltage FlyCap Undervoltage 293 Troubleshooting recommendation Disconnect the AC output side switch and DC input side switch,5After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. Disconnect the AC output side switch and DC input side switch,5After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. No. 107 108 109 fault name FlyCap Precharge Failure FlyCap Precharge Abnormal PV String Overcurrent (String1~16) PV StringOvercurrent (String17~32) 110 111 PV StringReversed (String 1~16) fault cause Troubleshooting recommendation Flying capacitor precharge failure, possible causes: 1. PVEnergy deficit; 2Inverter flying capacitor voltage sampling anomaly; 1. Unreasonable control loop parameters 2. Hardware damage Possible causes: 1. String overcurrent; 2. String current sensor anomaly PVString reverse connection 294 Check if the string is reversed. No. fault name PV StringReversed (String17~32) 112 113 114 115 PVString Loss (String1~16) PVString Loss(String 17~32) PVInput Mode Error fault cause Troubleshooting recommendation PVString reverse connection Check if the string is reversed. String fuse disconnected (if applicable) Check if the fuse is blown. String fuse disconnected (if applicable) Check if the fuse is blown. PVThere are three access modes in total, with four channels.MPPTFor example: 1. Parallel mode: that isAAAAMode(homolo gous mode),PV1PV4homologous4Ro adPVConnect the same photovoltaic panel 2. Partial Parallel Mode: i.e.AACCMode,PV1an 295 InspectionPVIs the access mode correctly set?ABCD、 AACC、AAAA), reset in the correct way.PVConnection mode. 1. Confirm the actual connected circuitsPVIs the connection correct. 2. IfPVCorrectly connected, passedAPPor screen check the current settingsPVWhether the "access mode" corresponds to the actual access mode. 3. If the currently setPVThe "connection mode" does not No. fault name fault cause dPV2Homologous connection,PV3andP V4homologous connection 3. Stand-alone mode: i.e.ABCDMode(nonhomologous),PV1、 PV2、PV3、 PV4Independent connection,4RoadPV Each connected to a photovoltaic panel IfPVThe actual connection mode and equipment configurationPVThis fault will be reported if the access mode does not match. PV StringReversed (String33~48) 116 117 PVString Loss(String 33~48) PVString reverse connection Troubleshooting recommendation match the actual connection mode and needs to be adjusted.APPor the screen willPVSet the "Connection Mode" to match the actual situation. After completing the settings,PVandACPower supply disconnection and restart. 4. After the setup is completed, if the currentPVThe access mode is consistent with the actual access mode, but this fault error is still reported. Please contact the dealer or GoodWe after-sales service center. Check if the strings are reverse connected. Check if the fuse is blown. String fuse disconnected (if applicable) 296 No. fault name PV StringOvercurrent (String33~48) 118 fault cause Possible causes: 1. String overcurrent; 2. String current sensor anomaly 297 Troubleshooting recommendation No. 119 fault name Multi-string PV Phase Mismatch Failure fault cause PV input mode setting error 298 Troubleshooting recommendation Check whether the PV connection mode is correctly set (ABCD, AACC, AAAA), and reset the PV connection mode according to the correct configuration. 1. Verify that each connected PV string is correctly wired. 2. If the PV is correctly connected, check via the APP or screen whether the currently set "PV Connection Mode" corresponds to the actual connection mode. 3. If the currently set "PV Connection Mode" does not match the actual connection mode, it is necessary to use the APP or screen to set the "PV Connection Mode" to the mode consistent with the actual situation. After completing the settings, disconnect the PV and AC power supply and restart. 4. After the setup is completed, if the current "PV Connection Mode" matches the actual connection mode but this fault still appears, please contact the dealer or GoodWe after-sales service center. No. 120 121 fault name BAT 1Precharge Failure BAT 1 Relay Failure BAT 1Overvoltage 122 123 BAT 2Precharge Failure fault cause Battery1Pre-Charge circuit fault (preCharge resistance burnout, etc.) Battery1The relay fails to operate properly. Troubleshooting recommendation Check if the pre-circuit is in good condition, and verify that the Battery power on post-Battery voltage matches the busbar voltage. If they do not match, please contact the distributor or GoodWe after-sales service center. After Batterypower on, check whether the Battery relay operates and if the closing sound is heard. If it does not function, please contact the dealer or GoodWe after-sales service center. Battery1The input voltage exceeds the rated range of the machine. Verify whether Batteryvoltage is within the machine's rated range. Battery2Pre-Charge circuit fault (such as pre-Charge resistor burnout, etc.) Check if the pre-Charge circuit is functioning properly. Only after Battery power on, verify whether the Battery voltage matches the busbar voltage. If they do not match, please contact the distributor or GoodWe after-sales service center. 299 No. 124 fault name BAT 2 Relay Failure BAT 2Overvoltage 125 126 BAT1 Reversed BAT 2Reversed 127 128 129 BATConnection Abnormal Bat Overtemperature fault cause Battery2The relay fails to operate properly. Battery2Input voltage exceeds the rated range of the machine. Battery1Reverse polarity of positive and negative terminals Battery2Reverse polarity connection Troubleshooting recommendation After Batterypower on, check if the Battery relay is functioning and if the closing sound is audible. If it does not operate, please contact the distributor or GoodWe after-sales service center. Verify whether Batteryvoltage is within the machine's rated range. Check whether the polarity of the Battery and machine terminals is consistent. Check whether the polarity of the Battery and machine terminals is consistent. Abnormal Access Battery temperature too high, possible causes: 1Inverter Installation Location is not ventilated. 2Ambient temperature is too high. 3Internal fan operation abnormal. 300 Check if the Battery is functioning properly. No. 130 fault name Ref Voltage Abnormal 131 Cavity Temperature Too Low 132 AC SPD Fault 133 DC SPD Fault 134 135 Internal Fan Abnormal External Fan Abnormal fault cause Reference circuit Cavity temperature too low, possible causes: 1. The ambient temperature is too low. ACFailure of the lateral lightning protection device DCFailure of lateral lightning protection device Internal fan abnormality, possible causes: 1Abnormal fan power supply; 2mechanical fault(Locked rotor); 3Fan aging and damage. External fan abnormality, possible causes: 1Fan power supply abnormality; 2Mechanical fault(Locked rotor); 3Fan aging and damage. 301 Troubleshooting recommendation Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. ReplacementACLateral lightning protection device. ReplacementDCLateral lightning protection device. Disconnect the AC output side switch and DC input side switch,5 After a few minutes, close the AC output side switch and the DC input side switch. If fault persists, please contact the dealer or GoodWe after-sales service center. No. 136 137 fault name PID Abnormal Trip-SwitchTrip Warning fault cause PIDHardware fault orPVvoltage too highPIDSuspend Possible causes: Overcurrent orPVReverse connection causes the trip switch to trip. 302 Troubleshooting recommendation PVOvervoltage caused by voltagePIDPause WARNING No action required,PIDHardware fault can be turned off.PIDSwitch reclosure clearingPIDfault, replacementPIDdevice Please contact the dealer or GoodWe after-sales service center. The reason for disconnection is due to an occurrence.PVShort circuit or reverse connection, need to check for historical records.PVShort circuit or historyPVReverse connection of WARNING. If present, maintenance personnel should inspect the corresponding issue.PVAfter confirming there is no fault, the tripping switch can be manually closed, and then activated viaAPPInterface Clear History fault Operation Clears This WARNING. No. 138 fault name PV IGBT ShortCircuit Warning PV String Reversed Warning(String 1~16) 139 fault cause Possible causes: Overcurrent caused the trip switch to open. Possible causes: occurrencePVRevers e connection causes the trip switch to trip. 303 Troubleshooting recommendation Please contact the distributor or GoodWe aftersales service center. Maintenance personnel should follow the historicalPVShort circuit WARNING subcode, check for short circuit occurrenceBoostCheck if there is any fault in the hardware and external string; After confirming no fault, it can pass.APPInterface Clear History fault Operation Clears This WARNING. Contact the dealer or GoodWe after-sales service center. The maintenance personnel must follow the historicalPVReverse the WARNING subcode and check whether the corresponding string is reversed.PVIs there a voltage difference in the panel configuration? After checking and confirming no fault, it can be passed.APPInterface Clear History fault Operation Clears This WARNING. No. 140 141 fault name PV String Reversed Warning(String 17~32) Flash R/W Error Meter CommLoss 142 fault cause Troubleshooting recommendation Possible causes: occurrencePVRevers e connection causes the trip switch to trip. Contact the distributor or GoodWe after-sales service center. Maintenance personnel must follow the historicalPVReverse connection WARNING subcode, check whether the corresponding string is reversed, checkPVIs there a voltage difference in the panel configuration? After checking and confirming no fault, it can proceed.APPInterface Clear History fault Operation Clears This WARNING. Possible causes: flashContent has changed;flashEnd of life 1. Upgrade to the latest version of the program. 2. Contact the distributor or GoodWe after-sales service center. This WARNING may only be reported after enabling the power limit function. Possible causes: 1. Meter not connected; 2. The communication line connecting the meter to the Inverter is wired incorrectly. Check the meter wiring and ensure it is correctly connected. If fault persists after inspection, please contact the dealer or GoodWe after-sales service center. 304 No. 143 144 145 146 147 148 149 fault name PV Type Identification Failure PV String Mismatch CT Loss CT Reversed PE Loss PVString Terminal Overtemperature(Stri ng 1~8) PVString Terminal Overtemperature(Stri ng 9~16) fault cause Troubleshooting recommendation PVPanel identification hardware anomaly Contact the distributor or GoodWe after-sales service center. PVString mismatch, same circuitMPPTThe configurations of the two open-circuit voltage strings below are different. Check the two strings opencircuit voltage, and configure the strings with the same open-circuit voltage to the same circuit.MPPTUnder prolonged string mismatch, there are potential safety hazards. CTUnconnected InspectionCTWiring. CTReverse connection InspectionCTWiring. Ground wire not connected Check the ground wire. 37176RegisterPVter minal temperature alarm subcode1Set - 37177RegisterPVter minal temperature alarm subcode2Set - 305 No. 150 151 152 153 154 155 fault name PVString Terminal Overtemperature(Stri ng 17~20) Troubleshooting recommendation fault cause 37178RegisterPVter minal temperature alarm subcode3Set position - PV String Reversed Warning(String 33~48) Possible causes: occurrencePVRevers e connection causes the trip switch to trip. Please contact the distributor or GoodWe aftersales service center; maintenance personnel must follow the historicalPVReverse polarity WARNING subcode, check whether the corresponding string has reverse polarity, checkPVIs there a voltage difference in the panel configuration? After checking and confirming no fault, it can proceed.APPInterface Clear History fault Operation Clears This WARNING. BAT1 Voltage Low BAT2 Voltage Low Batteryvoltage is below the set value - Batteryvoltage is below the set value - Battery non-Charge mode, voltage below shutdown voltage - - - Low Voltage ofBAT Power BAT1 Voltage High 306 No. 156 fault name BAT2 Voltage High Troubleshooting recommendation fault cause - - PV String is shortcircuited to the ground of Protection. 2. The environment of PV StringInstallation is consistently humid, and the line-toground insulation is poor. 1. Check the impedance between PV String and Protection to ground. If a short circuit is found, rectify the short circuit point. 2. Check if the Inverter's PE cable is properly connected. 3. If it is confirmed that the impedance is indeed lower than the default value in rainy weather, please reset the "insulation resistanceProtection point". 158 Microgrid Overload Warning Excessive input at backup terminal current Occasional occurrences require no action; if this alarm appears frequently, please contact the dealer or GoodWe after-sales service center. 159 Manual Reset - - 160 GeneratorPhase Order Error - - Reuse (Generator) port configured as microgrid or large load, but actually connected to generator Use the APP to modify the reuse (generator) port configuration. 157 161 Online Detection of Low Insulation Resistance Multiplexed Port Configuration Abnormal 307 Troubleshooting recommendation No. fault name 162 Parallel Communication Timeout Shutdown - - 163 One-click Remote Shutdown - - 164 One-click Remote Shutdown - - 165 One-click Remote Shutdown - - 166 Oneclick Remote Shutdown - - DG Communication Failure Abnormal communication link between the control board and the diesel generator 1. Check the link communication harness and observe whether fault is eliminated. 2. Attempt to restart the machine and observe whether the fault is eliminated; 3. If the fault persists after restarting, please contact GoodWe's after-sales service center. BatteryOver Voltage 1. Single cell voltage too high 2. voltage collection line anomaly - 167 168 fault cause 308 No. fault name 1. Battery total pressure too high 2. Abnormal voltage collection line 169 170 Battery Under Voltage BatteryOver Current Troubleshooting recommendation fault cause 1. Single cell voltage too low 2. voltage collection line abnormality 1. Battery Total pressure too low 2. Abnormal voltage collection line 1. Chargecurrent is too large, Battery current limiting is abnormal: temperature and voltage value mutation 2. Inverter response anomaly - - - Battery dischargecurrent is too large 171 BatteryOver Temperature 1. Ambient temperature too high 2. Temperature sensor abnormality 309 - No. fault name Troubleshooting recommendation fault cause 1. Ambient temperature too high 2. Temperature sensor abnormality 172 173 Battery Under Temperature 1. Ambient temperature is too low 2. Temperature sensor abnormality 1. The ambient temperature is too low. 2. Temperature sensor abnormality Battery Pole Over Temperature Pole temperature too high 310 - - No. 174 fault name Battery Imbalance fault cause 1. Excessive temperature difference at different stages, Battery will impose restrictions on BatteryPower, i.e., limit the charging Dischargecurrent. Therefore, this issue is generally unlikely to occur. 2. The capacity of the battery cell degrades, leading to excessive internal resistance, significant temperature rise during current, and consequently, a large temperature difference. 3. Poor welding of battery cell tabs, leading to excessive current and rapid temperature rise in the cell. 4. Temperature sampling issue; 5. power cable loose connection 311 Troubleshooting recommendation No. fault name fault cause 1. Inconsistent aging levels of battery cells 2. Issues with the tab chips can also lead to excessive voltage differences between cells. 3. Imbalance issues in the battery pack can also lead to excessive voltage differences between cells. 4. Harness issue causing 1. Inconsistent aging levels of battery cells 2. Issues with the board chips can also lead to excessive voltage differences between battery cells. 3. Imbalance issues in the battery pack can also lead to excessive voltage differences between cells. 4. Wiring harness issue causing 312 Troubleshooting recommendation No. 175 fault name Insulation Resistance 176 Precharge Failure 177 Collection Line Failure fault cause Troubleshooting recommendation Insulation resistance failure Check if the ground wire is properly connected and restart the Battery. If the issue persists after restarting, please contact GoodWe's after-sales service center. Precharge failure It indicates that during the precharge process, the voltage across the precharge MOS consistently exceeds the specified threshold. After restarting the system, observe whether this fault persists, and check if the wiring is correct and if the precharge MOS is damaged. Battery acquisition line poor contact or disconnected Check the wiring and restart the Battery. If the issue persists after restarting, please contact GoodWe's after-sales service center. Single PV module string harness disconnected Single temperature acquisition line poor contact or disconnected 313 Check the wiring and restart the Battery. If the issue persists after restarting, please contact GoodWe's after-sales service center. No. fault name fault cause Troubleshooting recommendation Dual-channel current comparison error is too large, or current acquisition line circuit is abnormal. Dual-channel voltage comparison error is too large, or MCU and AFE voltage comparison error is too large, or voltage acquisition line loop is abnormal. Temperature acquisition circuit loop abnormal or poor contact, disconnected 178 Relay or MOS Over Temperature Overvoltage level 5 or overtemperature level 5, fuse the three-terminal fuse To replace the three-section fuse, please contact GoodWe's after-sales service center to replace the main control board. Relay or MOSFET overtemperature The fault indicates that the MOSFET temperature has exceeded the specified threshold. Power off and let it stand for 2 hours to allow temperature recovery. 314 No. 179 180 fault name Shunt Over Temperature fault cause Troubleshooting recommendation Shunt Overtemperature The fault indicates that the bypass diode temperature has exceeded the specified threshold. Shut down and allow it to stand for 2 hours to wait for temperature recovery. Relay or MOS open circuit 1. Upgrade the software, power off and let it sit for 5 minutes, then check if fault persists after restarting. 2. If the issue persists, replace the Battery package. Relay or MOS short circuit 1. Upgrade the software, power off and let it sit for 5 minutes, then check if fault persists after restarting. 2. If the issue persists, replace the Battery package. Communication abnormality between the master cluster and slave cluster, or inconsistency of battery cells between clusters. 1. Check the Battery information and software version of the slave device, and verify whether the communication line connection with the master device is normal. 2. Upgrade the software BMS1 Other Failure 1 (RES) 315 No. fault name fault cause Troubleshooting recommendation Battery system circuit harness abnormality, resulting in interlocking signal not forming a loop. Check if Terminal resistorInstallation is correct BMS and PCS communication anomaly Abnormal communication harness between BMS master and slave control Communication loss between main and auxiliary chips 316 Verify whether the communication line interface definition between Inverter and Battery is correct; 2. Please contact GoodWe's after-sales service center to check the backend data and verify whether the Inverter and Battery software are correctly matched. Check the wiring and restart the Battery. 2. Upgrade the Battery. If the issue persists after restarting, please contact GoodWe's after-sales service center. No. fault name fault cause Troubleshooting recommendation Abnormal MCCB and shunt trip Let the system stand idle and shut down for 5 minutes, then restart to check if fault persists. 2. Check for any looseness or misalignment in the blindmating and communication pins at the bottom of the PACK and PCU. MCU self-test failed Upgrade the software and restart the Battery. If the issue persists after restarting, please contact GoodWe's after-sales service center. The software version is too low or the BMS board is damaged. 2. The number of Inverter parallel units is large, and the Battery experiences excessive impact during pre-charging. 1. Upgrade the software and observe whether fault persists. 2. In the case of parallel operation, perform a black start on Battery before starting Inverter. MCU internal fault Upgrade the software and restart the Battery. Generally, this is to detect whether the MCU or external components are damaged. If the issue persists after restarting, please contact GoodWe's after-sales service center. 317 No. fault name fault cause Troubleshooting recommendation Master control current exceeds the specified threshold 1. Let the system stand for 5 minutes, then restart and check if fault persists. 2. Check if the Inverter is set with an excessively large Power, causing it to exceed the bus load. Cell inconsistency in parallel clusters Confirm whether the cells in cluster Battery are consistent. Cluster Battery Check whether the positive reverse polarity of and negative poles of the positive and negative string Battery are reversed. terminals 181 Air Conditioner Failure Severe overheating or overvoltage triggering the fire protection system Contact GoodWe After-Sales Service Center. Abnormal failure of air conditioning Try restarting the system. If fault persists, please contact GoodWe Customer Service Center. Cabinet door not closed Check whether the cabinet door is properly closed. Power supply voltage Verify that the power supply too high voltage value meets the air conditioning input voltage Insufficient power requirements, and proceed supply with re-power on only after confirmation. No voltage Input 318 No. fault name fault cause Troubleshooting recommendation Unstable power supply voltage Compressor instability Sensor poor contact or damaged Abnormal air conditioning fan 181 BMS2 Other Failure 2 (RES) There is an abnormality in the voltage or current inside the DCDC. DCDC overload or heat sink temperature too high Try restarting the system. If the fault persists, please contact GoodWe Customer Service Center. Refer to the specific DCfault content for details. Abnormal cell acquisition or inconsistent aging levels Please contact the GoodWe After-Sales Service Center. Fan operation not executed properly Please contact GoodWe after-sales service center. 1. Battery Shut down, check wiring and output port screw status 2. After confirmation, restart Output port screw the Battery and observe loose or poor contact whether the fault persists. If it does, please contact GoodWe's after-sales service center. 319 No. fault name fault cause Troubleshooting recommendation Battery has been used for too long or the battery cell is severely damaged. Please contact GoodWe after-sales service center to replace the pack. The software version is too low or the BMS board is damaged. 2. The number of Inverter parallel units is large, and the Battery experiences excessive impact during pre-charging. 1. Upgrade the software and observe whether fault persists. 2. In the case of parallel operation, perform a black start on Battery before starting Inverter. Heating film damaged Please contact GoodWe After-Sales Service Center. The three-terminal fuse of the heating film is blown, rendering the heating function unusable. Please contact GoodWe After-Sales Service Center. Software model, Cell Type, hardware model mismatch Check whether the software model, serial number (SN), Cell Type, and hardware model are consistent. If they are inconsistent, please contact GoodWe after-sales service center. 320 No. fault name fault cause Troubleshooting recommendation Thermal management board communication disconnection Let the system stand idle and shut down for 5 minutes, then restart to check if fault persists. 2. If the fault is not restored, contact GoodWe after-sales service to replace the pack. Thermal management board communication disconnection Let the system stand idle and shut down for 5 minutes, then restart to check if fault persists. 2. If the fault is not restored, contact GoodWe after-sales service to replace the pack. Thermal management board communication disconnection Let the system stand idle and shut down for 5 minutes, then restart to check if fault persists. 2. If the fault is not restored, contact GoodWe after-sales service to replace the pack. Let the system stand idle and shut down for 5 Pack fan fault signal trigger 321 minutes, then restart to check if fault persists. 2. If the fault is not restored, contact GoodWe after-sales service to replace the pack. No. 182 fault name fault cause Troubleshooting recommendation Output portvoltage too high Check the output portvoltage. If the output portvoltage is normal and the fault still cannot be resolved after restarting Battery, please contact GoodWe after-sales service center. The DCDC module detected that the Batteryvoltage exceeded the maximum Chargevoltage. Stop Charge and Discharge when SOC drops below 90% or remains idle for 2 hours. If the issue persists and restarting fault does not resolve it, please contact GoodWe Customer Service Center. Radiator temperature too high Let the Battery stand for 1 hour until the radiator temperature drops. If the issue persists and fault still occurs after restarting, please contact GoodWe's after-sales service center. Battery dischargecurrent is too large Check if the load exceeds the Battery's Discharge capability. Turn off the load or stop the PCS for 60 seconds. If the issue persists after restarting the fault, please contact GoodWe's after-sales service center. DCDC Failure 322 No. 183 fault name Battery Rack Circulating Current Failure fault cause Troubleshooting recommendation The positive and negative terminals of the port power harness are reversed with the combiner box Battery or PCS. Turn off the Battery manual switch, check if the output port wiring is correct, and restart the Battery. The Power output relay cannot close. Check whether the output port wiring is correct and if there is a short circuit. If the issue persists after restarting fault, please contact GoodWe after-sales service center. Power device temperature too high Let the Battery stand for 1 hour to allow the temperature of internal Power components to decrease. If the issue persists and restarting the fault does not resolve it, please contact GoodWe Customer Service Center. Relay sticking Restart fault still exists. Please contact GoodWe after-sales service center. 1. Cell imbalance 2. First power on undercharge correction - 323 No. fault name 184 BMS1 Other Failure 3 (Utility-Scale Storage) / BMS2 Other Failure 3 (LES) fault cause Troubleshooting recommendation Communication exception with Linux module 1. Check if the communication link is functioning properly. 2. Upgrade the software and restart the Battery to observe if the fault persists. If it does, please contact GoodWe's after-sales service center. Excessive temperature rise in battery cells Abnormal battery cell, contact GoodWe after-sales service to replace the pack. SOC below 10% Perform Charge on Battery. SN writing does not comply with the rules Check if the SN digits are normal. If abnormal, please contact GoodWe after-sales service center. 1. Battery Daisy chain communication anomaly within the cluster 2. Inconsistent aging levels of cells between Battery clusters 1. Check the contact condition of the single cluster Battery pack. 2. Confirm the usage of each cluster Battery, such as cumulative charge Discharge capacity, cycle count, etc. 3. Please contact GoodWe After-Sales Service Center. High Humidity inside the pack - Fuse blown Contact GoodWe after-sales service to replace the pack. Low Battery power Perform Charge on Battery. 324 No. fault name 185 BMS2 OtherFailure 4 (LES) Troubleshooting recommendation fault cause Circuit breaker anomaly Contact GoodWe after-sales service to replace the pack. External device abnormality Contact GoodWe after-sales service to replace the pack. - - - - Continuous overload (exceeding 690KVA) for 10s Please contact GoodWe After-Sales Service Center. Overload Protection (SP)) Continuous overload (exceeding 690KVA) for 10s Please contact GoodWe After-Sales Service Center. 190 Communication abnormality between the host AC and the meter when AC is powered on in parallel system 1. The meter may not be connected to the host. 2. The meter communication cable may be loose. 1. Check if the meter is connected to the host. 2. Check if the meter communication cable is loose. 191 The slave power meter in the parallel system is abnormal The meter is connected to the slave unit. Set the meter connection machine as the master. 186 187 188 186 Contactor Fault1 Contactor Fault 2 Overload protection (Ksic) 325 No. 192 fault cause Troubleshooting recommendation 1. Incorrect slave address setting 2. Slave communication line is loose 1. Check if the slave address is duplicated 2. Check if the parallel communication cable is loose. Fault Cause Troubleshooting Suggestions: BMS1 RACK1 Total voltage is too high warning 1. Battery system voltage too high 2. Voltage collection line abnormal 1. Discharge the battery to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. fault name In aparallel system, theslave device has a communication timeout with the master device afterAC power-on for more than 10 minutes 11.5.2.2 Battery failure No. 1 326 No. 2 3 Fault BMS1 RACK1 Total voltage is too low warning BMS1 RACK1 Cell voltage is too high warning Cause Troubleshooting Suggestions: 1. Battery system voltage too low 2. Voltage collection line abnormal 1. Charge the battery and leave it to see if the fault persists. 2. Check the inverter operation to see if it is not charging the battery due to problems such as the operating mode. Try charging the battery through the inverter and see if the fault is resolved. 3. If the fault is not restored, please contact the after-sales service center. 1. Individual cell voltage is too high 2. Voltage collection line is abnormal 1. Discharge the battery and leave it idle to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. 327 No. 4 5 Cause Troubleshooting Suggestions: BMS1 RACK1 Cell voltage is too low warning 1. Individual cell voltage is too low 2. Voltage collection line is abnormal 1. Charge the battery and leave it to see if the fault persists. 2. Check the inverter operation to see if it is not charging the battery due to problems such as the operating mode. Try charging the battery through the inverter and see if the fault is resolved. 3. If the fault persists, contact GoodWe after-sales service. BMS1 RACK1 Charging temperature is too high warning 1. Environment temperature too high 2. Temperature sensor malfunction 1. Stop charging and discharging, and leave it idle to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. Fault 328 No. 6 7 Fault Cause Troubleshooting Suggestions: BMS1 RACK1 Discharging temperature is too high warning 1. Environment temperature too high 2. Temperature sensor malfunction 1. Stop charging and discharging, and leave it idle to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. BMS1 RACK1 Charging temperature is too low warning 1. Check the cell temperature in the background. If the lowest temperature is higher than -20°C, set the battery to discharge to raise the cell temperature. 1. Environment 2. If the temperature is below temperature too low -20°C, turn off the battery and 2. Temperature place it in a warm sensor malfunction environment. Wait until the battery temperature rises before using it. 3. If the fault is not restored, please contact the after-sales service center. 329 No. 8 9 Troubleshooting Suggestions: Fault Cause BMS1 RACK1 Discharging temperature is too low warning 1. Check the cell temperature in the background. If the lowest temperature is higher than -20°C, set the battery to discharge to raise the cell temperature. 1. Environment 2. If the temperature is below temperature too low -20°C, turn off the battery and 2. Temperature place it in a warm sensor malfunction environment. Wait until the battery temperature rises before using it. 3. If the fault is not restored, please contact the after-sales service center. BMS1 RACK1 Charge overcurrent warning 1. Stop charging and leave it 1. Excessive alone to see if the fault charging current, persists; abnormal battery 2. Check whether the inverter current limiting: is set to excessive power, sudden changes in causing it to exceed the rated temperature and working current of the voltage values battery; 2. Abnormal inverter 3. If the overcurrent persists, response contact the GoodWe aftersales service center. 330 No. 10 11 Fault BMS1 RACK1 Discharge overcurrent warning BMS1 RACK1 Insulation resistance is too low warning Troubleshooting Suggestions: Cause 1. Stop discharging and leave 1. Excessive it alone to see if the fault discharging current, persists; abnormal battery 2. Check whether the inverter current limiting: is set to excessive power, sudden changes in causing it to exceed the rated temperature and working current of the voltage values battery; 2. Abnormal inverter 3. If the overcurrent persists, response contact the GoodWe aftersales service center. Check whether the ground wire is properly connected, Insulation resistance restart the battery, and if the damage or problem persists after abnormal contact restarting, please contact GoodWe After-Sales Service Center. 331 No. 12 Fault Cause Troubleshooting Suggestions: BMS1 RACK1 Cell excessive temperature differentials warning 1. When the temperature difference is too large at different stages, the battery will limit the battery power, i.e., limit the charging and discharging current. Therefore, this problem generally does not occur. 2. Battery cell capacity depletion leads to excessive internal resistance, resulting in significant temperature rise during overcurrent conditions and a large temperature difference. 3. Poor welding of the cell tabs causes excessive current flow, resulting in rapid heating of the cell. 4. Temperature sampling issues; 5. Loose power line connections Turn off the device, restart the battery, and wait for 2 hours. If the problem persists, contact GoodWe After-Sales Service Center. 332 No. 13 14 15 16 Cause Troubleshooting Suggestions: BMS1 RACK1 Post temperature is too high warning Excessive pole temperature 1. Stop charging and discharging, and leave it idle to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. BMS1 RACK1 Cell excessive voltage differentials warning 1. Inconsistent battery cell aging 2. Board chip issues can also cause excessive battery cell pressure differences; 3. Board balancing issues can also cause excessive battery cell pressure differences 4. Wiring harness issues cause 1. Stop charging and discharging, and leave it idle to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. BMS and PCS communication error Check that the communication cable between the battery and the inverter is properly connected. Abnormal voltage or current exists inside the DCDC. Upgrade the software, restart the battery, and if the problem persists after restarting, please contact the Solid State After-Sales Service Center. Fault BMS1 RACK1 PCS communication loss warning BMS1 RACK1 DCDC warning 333 No. 17 18 19 20 21 Fault Cause Troubleshooting Suggestions: BMS1 RACK1 Heat film MOS adhesion warning Heating film MOS damaged Contact the after-sales service. BMS1 RACK1 Heat film MOS open warning Heating circuit malfunction Contact the after-sales service. 1. Battery system voltage too high 2. Voltage collection line abnormal 1. Discharge the battery to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. 1. Battery system voltage too low 2. Voltage collection line abnormal 1. Charge the battery and leave it to see if the fault persists. 2. Check the inverter operation to see if it is not charging the battery due to problems such as the operating mode. Try charging the battery through the inverter and see if the fault is resolved. 3. If the fault persists, please contact the GoodWe AfterSales Service Center. 1. Individual cell voltage is too high 2. Voltage collection line is abnormal 1. Discharge the battery and leave it to see if the fault persists. 2. If the fault persists, please contact the GoodWe AfterSales Service Center. BMS1 RACK1 Total voltage is too high fault BMS1 RACK1 Total voltage is too low fault BMS1 RACK1 Cell voltage is too high fault 334 No. 22 23 Fault BMS1 RACK1 Cell voltage is too low fault BMS1 RACK1 Charging temperature is too high fault Cause Troubleshooting Suggestions: 1. Individual cell voltage is too low 2. Voltage collection line is abnormal 1. Charge the battery and leave it to see if the fault persists. 2. Check the inverter operation to see if it is not charging the battery due to problems such as the operating mode. Try charging the battery through the inverter and see if the fault is resolved. 3. If the fault persists, please contact the GoodWe AfterSales Service Center. 1. Environment temperature too high 2. Temperature sensor malfunction 1. Place the battery in a cool place, turn off the device, and leave it for 30 minutes. Restart the device and check if the fault persists. 2. If the fault persists, please contact the Solid State Technology after-sales service center. 335 No. 24 25 Fault BMS1 RACK1 Discharging temperature is too high fault BMS1 RACK1 Charging temperature is too low fault Cause Troubleshooting Suggestions: 1. Environment temperature too high 2. Temperature sensor malfunction 1. Place the battery in a cool place, turn off the device, and leave it for 30 minutes. Restart the device and check if the fault persists. 2. If the fault persists, please contact the Solid State Technology after-sales service center. 1. Check the cell temperature in the background. If the lowest temperature is higher than -20°C, set the battery to discharge to raise the cell temperature. 1. Environment 2. If the temperature is below temperature too low -20°C, turn off the battery and 2. Temperature place it in a warm sensor malfunction environment. Wait until the battery temperature rises before using it. 3. If the fault is not restored, please contact the after-sales service center. 336 No. 26 27 Fault BMS1 RACK1 Discharging temperature is too low fault BMS1 RACK1 Charge temperature is too low fault Troubleshooting Suggestions: Cause 1. Check the cell temperature in the background. If the lowest temperature is higher than -20°C, set the battery to discharge to raise the cell temperature. 1. Environment 2. If the temperature is below temperature too low -20°C, turn off the battery and 2. Temperature place it in a warm sensor malfunction environment. Wait until the battery temperature rises before using it. 3. If the fault is not restored, please contact the after-sales service center. 1. Stop discharging and leave 1. Excessive it alone to see if the fault charging current, persists; abnormal battery 2. Check whether the inverter current limiting: is set to excessive power, sudden changes in causing it to exceed the rated temperature and working current of the voltage values battery; 2. Abnormal inverter 3. If the overcurrent persists, response contact the GoodWe aftersales service center. 337 No. 28 29 Fault BMS1 RACK1 Discharge overcurrent fault BMS1 RACK1 Insulation resistance is too low fault Troubleshooting Suggestions: Cause 1. Stop discharging and leave 1. Excessive it alone to see if the fault discharging current, persists; abnormal battery 2. Check whether the inverter current limiting: is set to excessive power, sudden changes in causing it to exceed the rated temperature and working current of the voltage values battery; 2. Abnormal inverter 3. If the overcurrent persists, response contact the GoodWe aftersales service center. 1. Check whether the ground wire is properly connected Insulation resistance and restart the battery. damage or 2. Upgrade the software. If abnormal contact the problem persists, please contact the GoodWe AfterSales Service Center. 338 No. 30 Fault BMS1 RACK1 Cell excessive temperature differentials fault Cause Troubleshooting Suggestions: 1. When the temperature difference is too large at different stages, the battery will limit the battery power, i.e., limit the charging and discharging current. Therefore, this problem generally does not occur. 2. Battery cell capacity depletion leads to excessive internal resistance, resulting in significant temperature rise during overcurrent conditions and a large temperature difference. 3. Poor welding of the cell tabs causes excessive current flow, resulting in rapid heating of the cell. 4. Temperature sampling issues; 5. Loose power line connections Turn off the device, restart the battery, and wait for 2 hours. If the problem persists, contact GoodWe After-Sales Service Center. 339 No. 31 32 33 Fault BMS1 RACK1 Post temperature is too high fault BMS1 RACK1 Cell excessive voltage differentials fault BMS1 RACK1 Relay or MOS short-circuit fault Cause Troubleshooting Suggestions: Excessive pole temperature 1. Shut down the device and leave it idle for 30 minutes, then restart it to see if the fault persists. 2. If the fault persists, please contact the GoodWe AfterSales Service Center. 1. Inconsistent battery cell aging 2. Board chip issues can also cause excessive battery cell pressure differences; 3. Board balancing issues can also cause excessive battery cell pressure differences 4. Wiring harness issues cause Turn off the device, restart the battery, and wait for 2 hours. If the problem persists, contact GoodWe After-Sales Service Center. MOS short circuit 1. Upgrade the software, shut down the device and leave it idle for 5 minutes, then restart it to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. 340 No. 34 35 36 Fault BMS1 RACK1 Relay or MOS open-circuit fault BMS1 RACK1 The precharge failed fault BMS1 RACK1 Acquisition line fault Cause Troubleshooting Suggestions: MOS open circuit 1. Upgrade the software, shut down the device and leave it idle for 5 minutes, then restart it to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. The voltage across the precharge MOS always exceeds the specified threshold. 1. Upgrade the software, shut down the device and leave it idle for 5 minutes, then restart it to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. Poor contact or disconnection of battery collection line. Shut down the device, check the wiring, restack the batteries, and restart the device. If the problem persists, please contact GoodWe After-Sales Service Center. 341 No. 37 38 39 40 Fault BMS1 RACK1 Relay or MOS temperature is too high fault BMS1 RACK1 Diverter temperature is too high fault BMS1 RACK1 Slave MCU communication fault BMS1 RACK1 BMU communication fault Cause Troubleshooting Suggestions: Relay or MOS over temperature 1. Upgrade the software, shut down the device and leave it idle for 30 minutes, then restart it to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. Diverter over temperature 1. Upgrade the software, shut down the device and leave it idle for 30 minutes, then restart it to see if the fault persists. 2. If the fault persists, contact the GoodWe After-Sales Service Center. Loss of communication between master and slave chips 1. Check the wiring and restart the battery. 2. Upgrade the battery. If the problem persists after restarting, please contact the GoodWe After-Sales Service Center. Abnormal communication wiring harness between BMS master control and slave control 1. Check the wiring and restart the battery. 2. Upgrade the battery. If the problem persists after restarting, please contact the GoodWe After-Sales Service Center. 342 No. 41 42 43 44 Fault BMS1 RACK1 Microelectronics fault BMS1 RACK1 Hardware overcurrent fault BMS1 RACK1 Application software fault BMS1 RACK1 Parallel RACK fault Cause Troubleshooting Suggestions: Internal MCU failure Upgrade the software, restart the battery, and if the problem persists after restarting, please contact the Solid State After-Sales Service Center. 1. Software version is too low or BMS board is damaged. 2. There are too many inverters connected in parallel, causing excessive impact on the battery during pre-charging. 1. Upgrade the software and observe whether the fault persists. 2. If multiple units are connected in parallel, start the battery first, then start the inverter. MCU self-test failed Upgrade the software, restart the battery, and if the problem persists after restarting, please contact the Solid State After-Sales Service Center. Communication abnormalities between the master cluster and slave cluster, or inconsistencies between the cells of different clusters. 1. Check the battery information and software version of the slave machine, and whether the communication line connection with the host machine is normal. 2. Upgrade the software. 343 No. 45 46 47 48 49 Fault BMS1 RACK1 DCDC fault BMS1 RACK1 Inconsistent cell fault BMS1 RACK1 The output port over temperature fault Cause Troubleshooting Suggestions: DCDC overload or excessive heat sink temperature, etc. Upgrade the software, restart the battery, and if the problem persists after restarting, please contact the Solid State After-Sales Service Center. 1. Battery cell identification error 2. Stacking of different types of battery cells Check the cell type. Loose screws or poor contact at the output port. 1. Turn off the battery, check the wiring and output port screws. 2. After confirmation, restart the battery and observe whether the fault persists. If it does, contact the GoodWe After-Sales Service Center. The battery has been used for too BMS1 RACK1 SOH too long or the battery low fault cell is severely damaged. BMS1 RACK1 Heating film MOS Threeterminal fault Heating film mos damaged Replace pack Contact the after-sales service. 11.5.3 Operation After Fault Clearance In the energy conservation system, after some fault clearances complete, further operations are needed for the system to restore normal work. 344 11.5.3.1 Clear AFCI Alarm [Software]: SolarGo App [Clearance method]: 1. Step 1: Go to the settings page via Home > Settings > Advanced Settings > DC AFCI to set up the AFCI detection function. 2. Tap [Clear AFCI Alarm]. 345 12 Technical Parameters 12.1 Inverter Parameters Technical Data GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 Battery Type Li-ion Li-ion Li-ion Li-ion Nominal Battery Voltage (V) 380 380 380 380 Battery Voltage Range (V) 350~550 350~550 350~550 350~550 Start-up Voltage (V)*1 380 380 380 380 Number of Battery Input 1 1 1 1 Max. Continuous Charging Current (A) 11.9 14.3 19.8 23.7 Max. Continuous Discharging Current (A) 8.7 10.5 14.5 17.4 Max. Charging Power (kW) 4.5 5.4 7.5 9 Max. Discharging Power (kW) 3.3 3.96 5.5 6.6 Battery Side 346 Technical Data GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 Max. Input Power (kW) 6 7.2 10 12 Max. Input Voltage (V)*2 600 600 600 600 MPPT Operating Voltage Range (V)*3 40~560 40~560 40~560 40~560 MPPT Voltage Range at Nominal Power (V) 150~500 150~500 170~500 210~500 Start-up Voltage (V) 50 50 50 50 Nominal Input Voltage (V) 400 400 400 400 Max. MPPT Current (A) 20 20 20 20 Max. MPPT Short Circuit Current (A) 26 26 26 26 Max. Backfeed Current to The Array (A) 0 0 0 0 Number of MPPTs 2 2 2 2 PV Side 347 Technical Data GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 Number of Strings per MPPT 1/1 1/1 1/1 1/1 Nominal Power (kW) 3 3.6 5 6 Nominal Apparent Power to Grid (kVA) 3 3.6 5 6 Max. Apparent Power to Grid (kVA) 3 3.6 5 6 Nominal Apparent Power from Grid (kVA) 3 3.6 5 6 Max. Apparent Power from Grid (kVA)*4 6 7.2 10 12 Nominal Voltage (V) 220/230/240, L/N/PE 220/230/240, L/N/PE 220/230/240, L/N/PE 220/230/240, L/N/PE Voltage Range (V) 170~280 170~280 170~280 170~280 Nominal Frequency (Hz) 50/60 50/60 50/60 50/60 Frequency Range (Hz) 45~55 / 55~65 45~55 / 55~65 45~55 / 55~65 45~55 / 55~65 AC Side (On-grid) 348 Technical Data GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 Max. Current to Grid (A) 13.7 at 220V 13.1 at 230V 12.5 at 240V 16.4 at 220V 15.7 at 230V 15 at 240V 22.8 at 220V 21.8 at 230V 20.9 at 240V 27.3 at 220V 26.1 at 230V 25 at 240V Max. Current From Grid(A) 27.3 at 220V 26.1 at 230V 25 at 240V 32.8 at 220V 31.4 at 230V 30 at 240V 45.5 at 220V 43.5 at 230V 41.7 at 240V 50 at 220V 50 at 230V 50 at 240V Nominal Current From Grid (A) 13.7 at 220V 13.1 at 230V 12.5 at 240V 16.4 at 220V 15.7 at 230V 15 at 240V 22.8 at 220V 21.8 at 230V 20.9 at 240V 27.3 at 220V 26.1 at 230V 25 at 240V Max. Output Fault Current (Peak and Duration) (A) 96 at 3μs 96 at 3μs 96 at 3μs 96 at 3μs Inrush Current (Peak and Duration) (A) 96 at 3μs 96 at 3μs 96 at 3μs 96 at 3μs Nominal Current (A) 13.7 at 220V 13.1 at 230V 12.5 at 240V 16.4 at 220V 15.7 at 230V 15 at 240V 22.8 at 220V 21.8 at 230V 20.9 at 240V 27.3 at 220V 26.1 at 230V 25 at 240V *4 349 Technical Data GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging) ~1 (Adjustable from 0.8 leading to 0.8 lagging) ~1 (Adjustable from 0.8 leading to 0.8 lagging) ~1 (Adjustable from 0.8 leading to 0.8 lagging) THDi <3% <3% <3% <3% Maximum Output Overcurrent Protection (A) 96 96 96 96 Type of Voltage a.c. a.c. a.c. a.c. Nominal Output Apparent Power (kVA) 3 3.6 5 6 Max. Output Apparent Power (kVA) 3.0 (6.0, 10s) 3.6 (7.2, 10s) 5.0 (10.0, 10s) 6.0(12.0, 10s) 7.2 10 12 16.4 at 220V 15.7 at 230V 15 at 240V 22.8 at 220V 21.8 at 230V 20.9 at 240V 27.3 at 220V 26.1 at 230V 25 at 240V Back-up Side Max. Output Apparent 6 Power (Bypass) (kVA) Nominal Output Current (A) 13.7 at 220V 13.1 at 230V 12.5 at 240V 350 Technical Data GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 Max. Output Current (A)*5 13.7 at 220V 13.1 at 230V 12.5 at 240V 16.4 at 220V 15.7 at 230V 15 at 240V 22.8 at 220V 21.8 at 230V 20.9 at 240V 27.3 at 220V 26.1 at 230V 25 at 240V Max. Output Current (Bypass) (A)*5 27.3 32.8 45.5 50 Max. Fault Current (Peak and Duration) (A) 96 at 3μs 96 at 3μs 96 at 3μs 96 at 3μs Inrush Current (Peak and Duration) (A) 96 at 3μs 96 at 3μs 96 at 3μs 96 at 3μs Max. Output Overcurrent Protection (A) 96 96 96 96 Nominal Output Voltage (V) 220/230/240, L/N/PE 220/230/240, L/N/PE 220/230/240, L/N/PE 220/230/240, L/N/PE Nominal Output Frequency (Hz) 50/60 50/60 50/60 50/60 THDv (@Linear Load) <3% <3% <3% <3% 97.60% 97.60% 97.60% 97.60% Efficiency Max. Efficiency 351 Technical Data GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 European Efficiency 96.50% 96.50% 96.80% 97.00% Max. Battery to AC Efficiency 98.00% 98.00% 98.00% 98.00% PV String Current Monitoring Integrated Integrated Integrated Integrated PV Insulation Resistance Detection Integrated Integrated Integrated Integrated Residual Current Monitoring Integrated Integrated Integrated Integrated PV Reverse Polarity Protection Integrated Integrated Integrated Integrated Battery Reverse Polarity Protection Integrated Integrated Integrated Integrated Anti-islanding Protection Integrated Integrated Integrated Integrated AC Overcurrent Protection Integrated Integrated Integrated Integrated AC Short Circuit Protection Integrated Integrated Integrated Integrated Protection 352 Technical Data GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 AC Overvoltage Protection Integrated Integrated Integrated Integrated DC Surge Protection Type II Type II Type II Type II AC Surge Protection Type II Type II Type II Type II RSD Optional Optional Optional Optional AFCI Integrated Integrated Integrated Integrated Remote Shutdown Integrated Integrated Integrated Integrated Operating Temperature Range (℃) -35~+60 (Derating at +40) -35~+60 (Derating at +40) -35~+60 (Derating at +40) -35~+60 (Derating at +40) Operating Environment Outdoor Outdoor Outdoor Outdoor Relative Humidity 0~95% 0~95% 0~95% 0~95% Max. Operating Altitude (m) 4000 (>2000 derating) 4000 (>2000 derating) 4000 (>2000 derating) 4000 (>2000 derating) Cooling Method Natural convection Natural convection Natural convection Natural convection User Interface LED, WLAN+APP LED, WLAN+APP LED, WLAN+APP LED, WLAN+APP General Data 353 Technical Data GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 Communicatio n with BMS CAN CAN CAN CAN Communicatio n RS485, RS485, RS485, RS485, WiFi+LAN+Blue WiFi+LAN+Blue WiFi+LAN+Blue WiFi+LAN+Blue tooth tooth tooth tooth Communicatio n Protocols Modbus-RTU, Modbus-TCP Modbus-RTU, Modbus-TCP Modbus-RTU, Modbus-TCP Modbus-RTU, Modbus-TCP Weight (kg) 24 24 24 24 Dimension (W×H×D mm) 800*300*270 800*300*270 800*300*270 800*300*270 Noise Emission ≤30 (dB) ≤30 ≤30 ≤30 Topology Non-isolated Non-isolated Non-isolated Non-isolated Power Selfconsumption at Night (W) ≤10 ≤10 ≤10 ≤10 Ingress Protection Rating IP66 IP66 IP66 IP66 DC Connector MC4 MC4 MC4 MC4 AC Connector plug & play terminal plug & play terminal plug & play terminal plug & play terminal Environmental Category 4K4H 4K4H 4K4H 4K4H 354 Technical Data Pollution Degree GW3K-EHAG20 GW3.6K-EHAG20 GW5K-EHAG20 GW6K-EHAG20 III III III III (Outside of the (Outside of the (Outside of the (Outside of the inverter) inverter) inverter) inverter) Overvoltage Category DC II / AC III DC II / AC III DC II / AC III DC II / AC III Protective Class I I I I Storage Temperature (℃) -40~+70 -40~+70 -40~+70 -40~+70 Decisive Voltage Class (DVC) Battery: A PV: C AC: C Com: A Battery: A PV: C AC: C Com: A Battery: A PV: C AC: C Com: A Battery: A PV: C AC: C Com: A Mounting Method Wall/Floor Mounted Wall/Floor Mounted Wall/Floor Mounted Wall/Floor Mounted Active Antiislanding Method SMS(Slip-mode SMS(Slip-mode SMS(Slip-mode SMS(Slip-mode frequency) frequency) frequency) frequency) +AFD +AFD +AFD +AFD Country of Manufacture China China China China Certification Grid Standard IEC/EN 61000-6-1/-2/-3/-4, IEC/EN 62920, CISPR 11, EN 55011, AS/NZS 61000.6.3/.4, AS 61000.6.4 Safety Regulation IEC62109-1/-2, IEC 63037 EMC IEC/EN 61000-6-1/-2/-3/-4 355 GW8K-EHA-G20 GW9.999K-EHAG20 GW10K-EHA-G20 Battery Type Li-ion Li-ion Li-ion Nominal Battery Voltage (V) 380 380 380 Battery Voltage Range (V) 350~550 350~550 350~550 Start-up Voltage (V)*1 380 380 380 Number of Battery Input 1 1 1 Max. Continuous Charging Current (A) 31.6 35.6 35.6 Max. Continuous Discharging Current (A) 23.2 29 29 Max. Charging Power (kW) 12 13.5 13.5 Max. Discharging Power (kW) 8.8 11 11 Max. Input Power (kW) 16 20 20 Max. Input Voltage (V)*2 600 600 600 Technical Data Battery Side PV Side 356 Technical Data GW8K-EHA-G20 GW9.999K-EHAG20 GW10K-EHA-G20 MPPT Operating Voltage Range (V)*3 40~560 40~560 40~560 MPPT Voltage Range at Nominal Power (V) 170~500 190~500 190~500 Start-up Voltage (V) 50 50 50 Nominal Input Voltage (V) 400 400 400 Max. MPPT Current 20 (A) 20 20 Max. MPPT Short Circuit Current (A) 26 26 26 Max. Backfeed Current to The Array (A) 0 0 0 Number of MPPTs 4 4 4 Number of Strings per MPPT 1/1/1/1 1/1/1/1 1/1/1/1 8 9.999 10 Nominal Apparent 8 Power to Grid (kVA) 9.999 10 Max. Apparent 8 Power to Grid (kVA) 9.999 10 AC Side (On-grid) Nominal Power (kW) 357 Technical Data GW8K-EHA-G20 GW9.999K-EHAG20 GW10K-EHA-G20 Nominal Apparent Power from Grid (kVA) 8 9.999 10 Max. Apparent Power from Grid (kVA)*4 14.5 14.5 14.5 Nominal Voltage (V) 220/230/240,L/N/ PE 220/230/240,L/N/ PE 220/230/240,L/N/ PE Voltage Range (V) 170~280 170~280 170~280 Nominal Frequency (Hz) 50/60 50/60 50/60 Frequency Range (Hz) 45~55 / 55~65 45~55 / 55~65 45~55 / 55~65 Max. Current to Grid (A) 36.4 at 220V 34.8 at 230V 33.4 at 240V 43.5 at 220V 43.5 at 230V 41.7 at 240V 43.5 at 220V 43.5 at 230V 41.7 at 240V Max. Current From Grid (A)*4 63 at 220V 63 at 230V 60.5 at 240V 63 at 220V 63 at 230V 60.5 at 240V 63 at 220V 63 at 230V 60.5 at 240V Nominal Current From Grid (A) 36.4 at 220V 34.8 at 230V 33.4 at 240V 45.5 at 220V 43.5 at 230V 41.7 at 240V 45.5 at 220V 43.5 at 230V 41.7 at 240V 358 Technical Data GW8K-EHA-G20 GW9.999K-EHAG20 GW10K-EHA-G20 Max. Output Fault Current (Peak and Duration) (A) 120 at 3μs 120 at 3μs 120 at 3μs Inrush Current (Peak and Duration) (A) 120 at 3μs 120 at 3μs 120 at 3μs Nominal Current (A) 36.4 at 220V 34.8 at 230V 33.4 at 240V 43.5 at 220V 43.5 at 230V 41.7 at 240V 43.5 at 220V 43.5 at 230V 41.7 at 240V Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging) ~1 (Adjustable from 0.8 leading to 0.8 lagging) ~1 (Adjustable from 0.8 leading to 0.8 lagging) THDi <3% <3% <3% Maximum Output Overcurrent Protection (A) 120 120 120 Type of Voltage a.c. a.c. a.c. Nominal Output Apparent Power (kVA) 8 10 10 Max. Output Apparent Power (kVA) 8.0(16.0, 10s) 10.0(20.0, 10s) 10.0(20.0, 10s) Back-up Side 359 Technical Data GW8K-EHA-G20 GW9.999K-EHAG20 GW10K-EHA-G20 Max. Output Apparent Power (Bypass) (kVA) 14.5 14.5 14.5 Nominal Output Current (A) 36.4 at 220V 34.8 at 230V 33.4 at 240V 43.5 at 220V 43.5 at 230V 41.7 at 240V 43.5 at 220V 43.5 at 230V 41.7 at 240V Max. Output Current (A)*5 36.4 at 220V 34.8 at 230V 33.4 at 240V 43.5 at 220V 43.5 at 230V 41.7 at 240V 43.5 at 220V 43.5 at 230V 41.7 at 240V Max. Output Current (Bypass) (A)*5 63 63 63 Max. Fault Current (Peak and Duration) (A) 120 at 3μs 120 at 3μs 120 at 3μs Inrush Current (Peak and Duration) (A) 120 at 3μs 120 at 3μs 120 at 3μs Max. Output Overcurrent Protection (A) 120 120 120 Nominal Output Voltage (V) 220/230/240,L/N/ PE 220/230/240,L/N/ PE 220/230/240,L/N/ PE Nominal Output Frequency (Hz) 50/60 50/60 50/60 360 Technical Data GW8K-EHA-G20 GW9.999K-EHAG20 GW10K-EHA-G20 THDv (@Linear Load) <3% <3% <3% Max. Efficiency 97.50% 97.50% 97.50% European Efficiency 96.80% 96.80% 96.80% Max. Battery to AC Efficiency 97.80% 97.80% 97.80% PV String Current Monitoring Integrated Integrated Integrated PV Insulation Resistance Detection Integrated Integrated Integrated Residual Current Monitoring Integrated Integrated Integrated PV Reverse Polarity Protection Integrated Integrated Integrated Battery Reverse Polarity Protection Integrated Integrated Integrated Anti-islanding Protection Integrated Integrated Integrated AC Overcurrent Protection Integrated Integrated Integrated AC Short Circuit Protection Integrated Integrated Integrated Efficiency Protection 361 Technical Data GW8K-EHA-G20 GW9.999K-EHAG20 GW10K-EHA-G20 AC Overvoltage Protection Integrated Integrated Integrated DC Surge Protection Type II Type II Type II AC Surge Protection Type II Type II Type II RSD Optional Optional Optional AFCI Integrated Integrated Integrated Remote Shutdown Integrated Integrated Integrated Operating Temperature Range (℃) -35~+60 (Derating at +40) -35~+60 (Derating at +40) -35~+60 (Derating at +40) Operating Environment Outdoor Outdoor Outdoor Relative Humidity 0~95% 0~95% 0~95% Max. Operating Altitude (m) 4000 (>2000 derating) 4000 (>2000 derating) 4000 (>2000 derating) Cooling Method Natural convection Natural convection Natural convection User Interface LED, WLAN+APP LED, WLAN+APP LED, WLAN+APP Communication with BMS CAN CAN CAN Communication RS485, RS485, RS485, WiFi+LAN+Bluetoot WiFi+LAN+Bluetoot WiFi+LAN+Bluetoot h h h General Data 362 Technical Data GW8K-EHA-G20 GW9.999K-EHAG20 GW10K-EHA-G20 Communication Protocols Modbus-RTU, Modbus-TCP Modbus-RTU, Modbus-TCP Modbus-RTU, Modbus-TCP Weight (kg) 26 26 26 Dimension (W×H×D mm) 800*300*270 800*300*270 800*300*270 Noise Emission (dB) ≤35 ≤35 ≤35 Topology Non-isolated Non-isolated Non-isolated Power Selfconsumption at Night (W) ≤10 ≤10 ≤10 Ingress Protection Rating IP66 IP66 IP66 DC Connector MC4 MC4 MC4 AC Connector plug & play terminal plug & play terminal plug & play terminal Environmental Category 4K4H 4K4H 4K4H III (Outside of the III (Outside of the III (Outside of the inverter) inverter) inverter) Overvoltage Category DC II / AC III DC II / AC III DC II / AC III Protective Class I I I Pollution Degree 363 Technical Data GW8K-EHA-G20 GW9.999K-EHAG20 GW10K-EHA-G20 Storage Temperature (℃) -40~+70 -40~+70 -40~+70 Decisive Voltage Class (DVC) Battery: A PV: C AC: C Com: A Battery: A PV: C AC: C Com: A Battery: A PV: C AC: C Com: A Mounting Method Wall/Floor Mounted Wall/Floor Mounted Wall/Floor Mounted Active Antiislanding Method SMS(Slip-mode frequency) +AFD SMS(Slip-mode frequency) +AFD SMS(Slip-mode frequency) +AFD Country of Manufacture China China China Certification Grid Standard IEC/EN 61000-6-1/-2/-3/-4, IEC/EN 62920, CISPR 11, EN 55011, AS/NZS 61000.6.3/.4, AS 61000.6.4 Safety Regulation IEC62109-1/-2, IEC 63037 EMC IEC/EN 61000-6-1/-2/-3/-4 *1: If there's no PV, start-up voltage will be 380V. *2: When the input voltage is 560V-600V, the inverter will enter standby mode, and the voltage returns to 560V to enter the normal operation state. *3: Please refer to the user manual for the MPPT Voltage Range at Nominal Power. *4: GOODWE ESA series has internal bypass 63A passthrough ability to supprt whole home backup solution. If the customer don't want to do any breaker upgrade, the main breaker size in SolarGo(or SEMS+) can be set as previous breaker size. *5: If the Back-up port is not used, select an appropriate circuit breaker based on theAC Max. Output Current. 364 12.2 Battery Technical Data Technical Data Rated Energy (kWh) Usable Energy (kWh)*1 GW5.1-BAT- GW8.3-BAT- GW5.1-BAT- GW8.3-BATD-G20 D-G20 D-G21 D-G21 5.12 8.32 5.12 8.32 5 8 5 8 LFP (LiFePO4) Battery Type Operating Voltage Range (V) (single phase system) 350~550 Operating Voltage Range (V) (three phase system) 700~950 Max. Input Current (System) (A) 12 19 12 19 Max. Output Current (System) (A) 13.2 21 13.2 21 Max. Input Power (System) (kW)*2 5 8 5 8 Max. Output Power (System) (kW)*2 5 8 5 8 Peak.Output Power (System) (kW)*2 7.5 @10s 12 @10s 7.5 @10s 12 @10s Charging Temperature Range (°C) -18~55 2~55 Discharging Temperature Range (°C) -20~55 -20~55 Relative Humidity 5-95% Max. Operating Altitude (m) 4000 365 Technical Data GW5.1-BAT- GW8.3-BAT- GW5.1-BAT- GW8.3-BATD-G20 D-G20 D-G21 D-G21 Noise Emission (dB) ≤29 Communication CAN Weight (kg) 57.5±1 79±1 Dimensions (W×H×D mm) Optional Function Configuration 57.5±1 79±1 800*326*270 heating / Ingress Protection IP66 Storage Temperature (℃) -20 ~55 12 months (-20℃~35℃) Max. Storage time 6 months (35℃~45℃) Scalability 6 pcs Mounting Method Floor stacked / Wall-mounted ≥6000 (25±2℃ 0.5C 90%DOD 70%EOL) Cycle Life Country of Manufacture Safety Standard and EMC Certification Transportati on China IEC62619, IEC60730, EN62477,IEC63056,IEC62040,CE, CEC CE, RCM UN38.3 ADR *1: Test conditions, 100% DOD (cell 2.85~3.6V voltage range), 0.2P charge & discharge at 25±2 °C for battery system at the beginning of life. Usable energy is defined by its initial design value. Actual available energy may vary depending on charge/discharge rate, environmental conditions (e.g. temperature), transport and storage factors. *2: Max. Input Power /Max. Output Power/Peak.Output Power derating will occur related to Temperature and 366 SOC. 12.3 Smart Meter Technical Data 12.3.1 GMK110 Technical Parameters Application Nominal Voltage (V) Voltage Voltage Range (V) Input Data Nominal Voltage Frequency (Hz) CT Ratio Current CT Quantity Communication Communication Distance (m) User Interface Voltage/Current Accuracy Active Energy Reactive Energy Power Consumption (w) Mechanica Dimension (W×H×D mm) l Weight (g) Parameter Mounting Method s Ingress Protection Rating Environme Operating Temperature Range (℃) ntal Storage Temperature Range (℃) Parameter Relative Humidity (Nons Condensing) Max. Operating Altitude (m) 12.3.2 GM330 367 GMK110 Single phase 220 85~288 50/60 120A/40mA 1 RS485 1000 2LED Class I Class I Class II <5 19*85*67 50 Rail Installation IP20 -30~ 60 -30~ 60 0~95% 3000 Technical Parameters Measuring Range Support Grid Type Communication Parameters Precision Accuracy General Data Environmental Parameters Certification Parameters Voltage Range L-N (Vac) Voltage Range L-L (Vac) Nominal Frequency (Hz) CT Ratio GM330 Three-phase, split-phase, single-phase 172~817 100~472 50/60 nA:5A Communication Method RS485 Communication Distance (m/ft) 1000/3280 Voltage/Current Active Energy Reactive Energy Dimension (WxHxDmm/in) Class 0.5 Class 0.5 Class 1 72x85x72/2.83x3.35×2.83 Housing 4 modules Weight (g/Ib) Mounting Method 240/0.53 DIN rail User Interface 4 LEDs, Reset Button Power Consumption (w) <5 Ingress Protection Rating Operating Temperature Range (℃/°F) Storage Temperature Range (℃/°F) Relative Humidity (No Condensing) Max. Operating Altitude (m/ft) IP20 Certificate UL1741/ANSI 12.4 Smart Dongle Technical Data 12.4.1 WiFi/LAN Kit-20 368 -30~+70/-22~+158 -30~70/-22~+158 0~95% 3000/9842 Technical Parameters Output Voltage (V) Power Consumption (W) Communication Port Ethernet Communication Wireless Parameters Bluetooth WiFi/LAN Kit-20 5 <=2 USB 10M/100Mbps Self-adaptation IEEE 802.11 b/g/n @2.4 GHz Bluetooth V4.2 BR/EDR and Bluetooth LE Standard Dimension (W×H×D mm) Weight (g) Mechanical Parameters Ingress Protection Rating Mounting Method Operating Temperature Range (℃) Storage Temperature Range (℃) Relative Humidity Max. Operating Altitude (m) 48.3*159.5*32.1 82 IP65 USB Port Plugging and Unplugging -30~+60 -40~+70 0-95% 4000 12.4.2 4G Kit-CN-G20 Product Model 4G Kit-CN-G20 Device Management Maximum Supported Number of Inverters 1 Power Parameter Input Voltage (V) 5 Power Consumption (W) <=4 Interface Method Communication Parameters USB 4G/3G/2G LTE-FDD : B1/B3/B5/B8 LTE-TDD : B34/B39/B40/B41 GNSS Location / Bluetooth Mechanical Parameters Dimension (W×H×D mm) Bluetooth V5.0 Weight (g) 87 Indicator LED* 2 48.3*95.5*32.1 369 Product Model 4G Kit-CN-G20 Mounting Method Plug and Play (PnP) SIM Dimension Environment Parameters Operating Temperature Range (℃) Micro sim,15mm*12mm Storage Temperature (℃) -40~+70 Relative Humidity 0-100% IP Grade IP66 Max. Operating Altitude (m) 4000 Safe Service Life (Year) 5 -30~+65 370 13 Appendix 13.1 FAQ 13.1.1 How to Conduct Auxiliary Detection for Smart Meters/CT? Meter detection function, which can detect whether the CT of the meter is connected correctly and the current operation status of the meter and CT. • Approach 1: 1. Access the detection page through Home > Settings > Electricity Meter/ CT Auxiliary Detection. 2. Click "Start Detection" and wait for the detection to complete. Then, view the detection results. • Approach 2: 1. Access the detection page through > [System Setup] > [Quick Setting] > [Meter/CT Assisted Test]. 2. Click "Start Detection" and wait for the detection to complete. Then, view the detection results. 13.1.2 How to Upgrade the Device Version Through the firmware information, you can view or upgrade the DSP version, ARM version, BMS version, and smart dongle software version of the inverter. Some smart dongles do not support software version upgrade via SolarGo App, and the actual situation shall prevail. • Upgrade prompt: When the user opens the APP, an upgrade prompt will pop up on the homepage, and the user can choose whether to upgrade or not. If you choose to upgrade, you can complete the upgrade by following the prompts on the interface. • Regular upgrade: Access the firmware information viewing interface through "Home" > "Settings" > "Firmware Information" 371 Click "Check for Updates". If there is a new version, complete the upgrade according to the prompts on the interface. • Forced Upgrade: The APP will push upgrade information, and users need to upgrade according to the prompts to continue using the app. You can complete the upgrade by following the prompts on the interface. Inverter Software Version Upgrade • To connect USB flash drive for local software upgrading. • Before upgrading the device using a USB flash drive, please contact the after-sales service center to obtain the software upgrade package and upgrade method. 13.2 Abbreviations Abbreviation Ubatt Ubatt,r Ibatt,max (C/D) EC,R UDCmax UMPP IDC,max ISC PV PAC,r Sr (to grid) Smax (to grid) Sr (from grid) Smax (from grid) UAC,r English Description Battery Voltage Range Nominal Battery Voltage Max. Charging Current Max. Discharging Current Rated Energy Max.Input Voltage MPPT Operating Voltage Range Max. Input Current per MPPT Max. Short Circuit Current per MPPT Nominal Output Power Nominal Apparent Power Output to Utility Grid Max. Apparent Power Output to Utility Grid Nominal Apparent Power from Utility Grid Max. Apparent Power from Utility Grid Nominal Output Voltage 372 Chinese Description 电池电压范围 额定电池电压 最⼤充/放电电流 额定能量 最⼤输⼊电压 MPPT 电压范围 每路 MPPT 最⼤输⼊电流 每路 MPPT 最⼤短路电流 Nominal Output Power 额定并⽹输出视在功率 最⼤并⽹输出视在功率 从电⽹买电额定输出视在功率 从电⽹买电最⼤输出视在功率 Nominal Output Voltage Abbreviation fAC,r IAC,max(to grid) IAC,max(from grid) P.F. Sr Smax IAC,max UAC,r fAC,r Toperating IDC,max UDC UDC,r UAC UAC,r Toperating Pmax PRF PD PAC,r F (Hz) ISC PV Udcmin-Udcmax UAC,rang(L-N) Usys,max English Description Nominal AC Grid Frequency Max. AC Current Output to Utility Grid Max. AC Current From Utility Grid Power Factor Back-up Nominal apparent power Max. Output Apparent Power (VA) Max. Output Apparent Power without Grid Max. Output Current Nominal Output Voltage Nominal Output Freqency Operating Temperature Range Max. Input Current Input Voltage DC Power Supply Power Supply/AC Power Supply Power Supply/Input Voltage Range Operating Temperature Range Max Output Power TX Power Power Consumption Power Consumption Frequency Max. Input Short Circuit Current Range of input Operating Voltage Power Supply Input Voltage Max System Voltage 373 Chinese Description 输出电压频率 最⼤并⽹输出电流 最⼤输⼊电流 Power Factor 离⽹额定视在功率 最⼤输出视在功率 最⼤输出电流 最⼤输出电压 额定输出电压频率 ⼯作温度范围 最⼤输⼊电流 输⼊电压 直流输⼊ 输⼊电压范围/交流输⼊ 输⼊电压范围/交流输⼊ ⼯作温度范围 最⼤功率 发射功率 功耗 功耗 频率 最⼤输⼊短路电流 ⼯作电压范围 适配器输⼊电压范围 最⼤系统电压 Abbreviation Haltitude,max PF THDi THDv C&I SEMS MPPT PID Voc Anti PID PID Recovery PLC Modbus TCP/IP Modbus RTU SCR UPS ECO mode TOU ESS PCS RSD EPO SPD ARC DRED RCR AFCI English Description Max. Operating Altitude Power Factor Total Harmonic Distortion of Current Total Harmonic Distortion of Voltage Commercial & Industrial Smart Energy Management System Maximum Power Point Tracking Potential-Induced Degradation Open-Circuit Voltage Anti-PID PID Recovery Power-line Commucation Modbus Transmission Control / Internet Protocol Modbus Remote Terminal Unit Short-Circuit Ratio Uninterruptable Power Supply Economical Mode Time of Use Energy Stroage System Power Conversion System Rapid shutdown Emergency Power Off Surge Protection Device zero injection/zero export Power Limit / Export Power Limit Demand Response Enabling Device Ripple Control Receiver AFCI 374 Chinese Description 最⾼⼯作海拔⾼度 Power Factor 电流谐波 电压谐波 ⼯商业 智慧能源管理系统 最⼤功率点跟踪 电位诱发衰减 开路电压 防PID PID修复 电⼒线载波通信 基于TCP/IP层的modbus 基于串⾏链路的modbus 短路⽐ 不间断电源 经济模式 使⽤时间 储能系统 电能转换系统 Rapid Shutdown 紧急关断 防雷保护 防逆流 命令响应设备 AFCI直流拉弧保护 Abbreviation GFCI RCMU FRT HVRT LVRT EMS BMS BMU BCU SOC SOH SOE SOP SOF SOS DOD English Description Ground Fault Circuit Interrupter Residual Current Monitioring Unit Fault Ride Through High Voltage Ride Through Low Voltage Ride Through Energy Management System Battery Management System Battery Measure Unit Battery Control Unit State of Charge State of Health State Of Energy State Of Power State Of Function State Of Safety Depth of discharge Chinese Description 接地故障分断器 残余电流监控装置 故障穿越 ⾼电压穿越 低电压穿越 能量管理系统 电池管理系统 电池采集单元 电池控制单元 电池的荷电状态 电池健康度 电池剩余能量 电池充放电能⼒ 电池的功能状态 安全状态 放电深度 13.3 Explanation of Terms • Overvoltage Category Definition Category I: applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a low level. Category II: applies to fixed downstream equipment. For example, appliances, portable tools and other plug-connected equipment; Voltage category III is used if there are special requirements for the reliability and suitability of such equipment. Category III: applies to fixed downstream equipment, including the main distribution board. For example, switchgear and other equipment in an industrial installation Category IV: applies to the upstream equipment in the power supply of the distribution device, including measuring instruments and upstream over-current protection devices. • Definition of Types of Damp Places ○ ○ ○ ○ 375 Environmental Parameters Temperature Range Humidity Range Level 3K3 4K2 4K4H 0~+40℃ -33~+40℃ -33~+40℃ 5% to 85% 5% to 85% 5% to 85% • Definition of Environmental Category: Outdoor Inverter: The ambient air temperature range is -25 to +60℃, and it is suitable for environments with pollution degree 3. Indoor Type II Inverter: The ambient air temperature range is -25 to +40℃, and it is suitable for environments with pollution degree 3. Indoor Type I Inverter: The ambient air temperature range is 0 to +40℃, and it is suitable for environments with pollution degree 2. • Definition of Pollution Degree Categories: Pollution Degree 1: No pollution or only dry non-conductive pollution. ○ ○ ○ ○ ○ ○ ○ Pollution Degree 2: In general, there is only non-conductive pollution, but the transient conductive pollution caused by occasional condensation must be taken into account. Pollution Degree 3: There is conductive pollution, or the non-conductive pollution becomes conductive pollution due to condensation. Pollution Degree 4: Persistent conductive pollution, such as pollution caused by conductive dust or rain and snow. 13.4 Battery SN Code Meaning Bits 11-14 of the product SN code are the production time code. The above picture has a production date of 2023-08-08 • The 11th and 12th digits represent the last two digits of the year of manufacture, 376 e.g., 2023 is represented by 23. • The 13th digit is the month of production, e.g., August is represented by 8; as follows: Month 1~9 10 11 12 Month 1~9 A B C • The 14th digit is the date of production, e.g., the 8th day is indicated by 8; priority is given to the use of numerical representation, e.g., 1~9 indicates the 1st~9th day, A indicates the 10th day, and so on. The letters I and O are not used to avoid confusion. The details are as follows: Production Date 1 2 3 4 5 6 7 8 9 Code 1 2 3 4 5 6 7 8 9 Production Date 10 11 12 13 14 15 16 17 18 Code A B C D E F G H J Production Date 21 22 23 24 25 26 27 28 29 Code M N P Q R S T U V 13.5 Safety Country No. Safety Code No. Safety Code Europe 1 IT-CEI 0-21 43 CZ-C 2 IT-CEI 0-16 44 CZ-D 3 DE LV with PV 45 RO-A 4 DE LV without PV 46 RO-B 5 DE-MV 47 RO-D 6 ES-A 48 GB-G98 7 ES-B 49 GB-G99-A 8 ES-C 50 GB-G99-B 377 No. Safety Code No. Safety Code 9 ES-D 51 GB-G99-C 10 ES-island 52 GB-G99-D 11 BE 53 NI-G98 12 FR 54 IE-16/25A 13 FR-island-50Hz 55 IE-72A 14 FR-island-60Hz 56 IE-ESB 15 PL-A 57 IE-EirGrid 16 PL-B 58 PT-D 17 PL-C 59 EE 18 PL-D 60 NO 19 NL-16/20A 61 FI-A 20 NL-A 62 FI-B 21 NL-B 63 FI-C 22 NL-C 64 FI-D 23 NL-D 65 UA-A1 24 SE-A 66 UA-A2 25 SE MV 67 EN 50549-1 26 SK-A 68 EN 50549-2 27 SK-B 69 DK-West-B-MVHV 28 SK-C 70 DK-East-B-MVHV 29 HU 71 DK-West-C-MVHV 30 CH 72 DK-East-C-MVHV 31 CY 73 DK-West-D-MVHV 32 GR 74 DK-East-D-MVHV 33 DK-West-A 75 FR-Reunion 34 DK-East-A 76 BE-LV(>30kVA) 35 DK-West-B 77 BE-HV 36 DK-East-B 78 CH-B 37 AT-A 79 NI-G99-A 38 AT-B 80 NI-G99-B 39 BG 81 NI-G99-C 378 No. Safety Code No. Safety Code 40 CZ-A-09 82 NI-G99-D 41 CZ-B1-09 83 IE-LV 42 CZ-B2-09 84 IE-MV 1 60Hz-Default 5 IEC 61727-50Hz 2 50Hz-Default 6 IEC 61727-60Hz 3 127Vac-60Hz-Default 7 Warehouse 4 127Vac-50Hz-Default Globle America 1 Argtina 30 US-ISO-NE-480Vac 2 US-208Vac 31 US-ISO-NE-208Vac-3P 3 US-240Vac 32 US-ISO-NE-220Vac-3P 4 Mexico-220Vac 33 US-ISO-NE-240Vac-3P 5 Mexico-440Vac 34 PR-208Vac 6 US-480Vac 35 PR-240Vac 7 US-208Vac-3P 36 PR-480 Vac 8 US-220Vac-3P 37 PR-208Vac-3P 9 US-240Vac-3P 38 PR-220Vac-3P 10 US-CA-208Vac 39 PR-240Vac-3P 11 US-CA-240Vac 40 Cayman 12 US-CA-480Vac 41 Brazil-220Vac 13 US-CA-208Vac-3P 42 Brazil-208Vac 14 US-CA-220Vac-3P 43 Brazil-230Vac 15 US-CA-240Vac-3P 44 Brazil-240Vac 16 US-HI-208Vac 45 Brazil-254Vac 17 US-HI-240Vac 46 Brazil-127Vac 18 US-HI-480Vac 47 Brazil-ONS 19 US-HI-208Vac-3P 48 Barbados 20 US-HI-220Vac-3P 49 Chile-BT 21 US-HI-240Vac-3P 50 Chile-MT 22 US-Kauai-208Vac 51 Colombia 379 No. Safety Code No. Safety Code 23 US-Kauai-240Vac 52 Colombia<0.25MW 1P 24 US-Kauai-480Vac 53 Colombia<0.25MW 3P 25 US-Kauai-208Vac-3P 54 IEEE 1547-208Vac 26 US-Kauai-220Vac-3P 55 IEEE 1547-20Vac 27 US-Kauai-240Vac-3P 56 IEEE 1547-240Vac 28 US-ISO-NE-208Vac 57 IEEE 1547-230/400Vac 29 US-ISO-NE-240Vac Oceania 1 Australia-A 4 Newzealand 2 Australia-B 5 Newzealand:2015 3 Australia-C 6 NZ-GreGrid China A 25 JP-420Vac-50Hz 26 JP-420Vac-60Hz Asia 1 2 China B 3 China's high pressure 27 JP-480Vac-50Hz 4 China's highest pressure 28 JP-480Vac-60Hz 5 China Power Station 29 Sri Lanka 6 China 242 Shandong 30 Singapore 7 China 242 Hebei 31 Israel-OG 8 China PCS 32 Israel-LV 9 Taiwan 33 Israel-MV 10 Hongkong 34 Israel-HV 11 China 242 Northeast 35 Vietnam 12 Thailand-MEA 36 Malaysia-LV 13 Thailand-PEA 37 Malaysia-MV 14 Mauritius 38 DEWA-LV 15 Korea 39 DEWA-MV 16 India 40 Saudi Arabia 17 India-CEA 41 JP-690Vac-50Hz 18 Pakistan 42 JP-690Vac-60Hz 380 No. Safety Code No. Safety Code 19 Philippines 43 Srilanka 20 Philippines-127Vac 44 IEC 61727-127Vac-50Hz 21 JP-50Hz 45 IEC 61727-127Vac-60Hz 22 JP-60Hz 46 JP-550Vac-50Hz 23 JP-440Vac-50Hz 47 JP-550Vac-60Hz 24 JP-440Vac-60Hz 48 India-Higher 1 South Africa-LV 4 Ghana 2 South Africa-B-MV 5 Ghana-HV 3 South Africa-C-MV Africa 13.6 Australia Safety Regulations For the Australian market, to comply with AS/NZS 4777.2:2020, please select from Australia A, Australia B, Australia C, or New Zealand. Please contact your local electricity grid operator on which Region to select. Selecting a Region B should then automatically load all region B setpoints for voltwatt, volt-var, underfrequency, overfrequency, etc. Volt–var response set-point values Region Default value U1 U2 U3 U4 Voltage 207V 220V 240V 258V Australia A Inverter reactive power level (Q) % of Srated Voltage 44 % supplying 0% 0% 60 % absorbin g 205V 220V 235V 255V Australia B Inverter reactive power level (Q) % of Srated 30 % supplying 0% 0% 40 % absorbin g Australia C Voltage 215V 230V 240V 255V 381 Region New Zealand Allowed range Default value U1 Inverter reactive power level (Q) % of Srated 44 % supplying Voltage 207V Inverter reactive power level (Q) % of Srated 60 % supplying Voltage 180 to 230 V Inverter reactive power level (Q) % of Srated U2 30 to 60 % supplying U3 U4 0% 0% 60 % absorbin g 220V 235V 244 V 0% 0% 60 % absorbin g 180 to 230 V 230 to 265 V 230 to 265 V 0% 30 to 60 % absorbin g 0% NOTE 1: Inverters may operate at a reactive power level with a range up to 100 % supplying or absorbing. NOTE 2: Australia C parameter set is intended for application in isolated or remote power systems. Volt–watt response default set-point values Region Default value U3 U4 Voltage 253V 260V Inverter maximum active power output level (P) % of Srated 100% 20% Voltage 250V 260V Australia B Inverter maximum active power output level (P) % of Srated 100% 20% Australia C Voltage 253V 260V Australia A 382 Region New Zealand Allowed range Default value U3 U4 Inverter maximum active power output level (P) % of Srated 100% 20% Voltage 242 V 250V Inverter maximum active power output level (P) % of Srated 100% 20% Voltage 235 to 255 V 240 to 265 V Inverter maximum active power output level (P) % of Srated 100% 20% NOTE: Australia C parameter set is intended for application in isolated or remote power systems. Passive anti-islanding voltage limit values Protective function Protective function limit Trip delay time Maximum disconnection time Undervoltage 2 (V <<) 70 V 1s 2s Undervoltage 1 (V <) 180 V 10 s 11 s Overvoltage 1 (V > 265 V ) 1s 2s Overvoltage 2 (V > 275V >) - 0.2 s Upper connection and reconnection frequency (fURF) Region fURF Australia A 50.15 Hz 383 Australia B 50.15 Hz Australia C 50.50 Hz New Zealand 50.15 Hz Setting steps: Step 1: Set the safety code to Australia A/B/C/New Zealand on Quick Settigs page based on actual needs. Step 2: Set the frequency parameters accordingly. 384 385 Contact Details GoodWe Technologies Co., Ltd. No. 90 Zijin Rd., New District, Suzhou, China 400-998-1212 www.goodwe.com [email protected] ">
/
ดาวน์โหลด
ขอแจ้งให้ทราบ คุณสามารถดูเอกสารได้ที่นี่ แต่ที่สำคัญที่สุดคือ AI ของเราได้อ่านแล้ว สามารถอธิบายสิ่งที่ซับซ้อนด้วยคำศัพท์ง่ายๆ ตอบคำถามของคุณในทุกภาษา และช่วยคุณนำทางเอกสารที่ยาวหรือซับซ้อนที่สุดได้อย่างรวดเร็ว
โฆษณา