MESSA IN FUNZIONE

51

Struttura dati di processo

Struttura dati di processo (versione 1.1)

WTB4FP MultiSwitchx-xxxxxxxxAxx:

A00 A70 A71

IO-Link

Process data

2 byte

Byte 0 : bit 15... 8

Byte 1: bit 7... 0

A72

V1.1

Bit 0/ Data type

Bit 1/ Data type

Bit... /

Descrip‐ tion / Data type

Bit... /

Descrip‐ tion / Data type

A73 A75

4 byte

Byte 0: bit 31... 24

Byte 1: bit 13... 16

Byte 2: bit 15... 8

Byte 3: bit 7... 0

Q

L1

/ Boolean

2...15 /

[empty]

Q

L2

/ Boolean

2...15 /

[Time measure‐ ment value] /

UInt 14

2 … 15 /

[Counter value] /

UInt 14

Qint.1 /

Boolean

2 … 15 /

[Length / speed measure‐ ment] /

SInt14

Q

L2

/ Boo‐ lean

2 /

Qint.1 /

Boolean

3 … 15 /

[Time measure‐ ment value] /

UInt13

Qint.1 / Boolean

2…7 / [empty]

8 … 31 / [Carrier load] / UInt 24

Eliminazione difetti

La tabella di rimozione dei disturbi mostra quali provvedimenti si devono adottare quando il sensore non funziona più.

Tabella 15: Eliminazione dei guasti

Indicatore LED / figura di errore

Causa

Il LED verde lampeggia

Le uscite di commutazione non si comportano conforme‐ mente alle figura X

Comunicazione IO-Link

1. Comunicazione IO-Link

2. Modifica della configura‐ zione

3. Corto circuito

Provvedimento

Nessuno

1. Nessuno

2. Adattamento della configu‐ razione

3. Controllare i collegamenti elettrici

Diminuire la distanza di com‐ mutazione il LED giallo si accende, nes‐ sun oggetto nella traiettoria del raggio

L'oggetto è nella traiettoria del raggio, il LED giallo non si accende

La distanza di lavoro è impo‐ stata a una distanza ecces‐ siva

La distanza tra sensore e oggetto è troppo grande o la distanza di commutazione ha un'impostazione troppo bassa

Aumentare la distanza di com‐ mutazione