Standby times. Busch-Jaeger 1098 U-101, 1098 UF-101
Add to My manuals42 Pages
Busch-Jaeger 1098 UF-101 is an electronic room temperature controller that offers precise temperature regulation for heating systems or electric floor heating. With its user-friendly interface and advanced features, it provides flexibility and comfort for managing indoor temperatures. Here's a brief overview of its capabilities:
-
Time-controlled temperature regulation: The device allows you to set specific heating schedules, ensuring optimal temperatures at desired times.
-
Simple operation: The clear display and intuitive button layout make it easy to navigate and adjust settings.
-
Energy-saving modes: The standby and valve protection functions help optimize energy consumption by automatically reducing heating when not needed.
advertisement
![Standby times. Busch-Jaeger 1098 U-101, 1098 UF-101 | Manualzz Standby times. Busch-Jaeger 1098 U-101, 1098 UF-101 | Manualzz](http://s2.manualzz.com/store/data/063824174_1-24c47186fe4d9b620e77bd884a9ea84b-360x466.png)
8.6.3 Standby times
Operation
Fig. 14: Menu item – Standby times
Standby mode is not activated at the factory. The activation and adjustment (reduction) of the temperature during absence can be activated or deactivated here.
Button Display Entry / Comments
– Press the menu button for 2 seconds to switch to the setting mode.
Starting times
Special functions
Standby
On / Off
On
– Select menu "Special functions" via the arrow buttons.
– Press the OK button to select menu item "Standby times".
The default setting flashes.
– Set the standby times to ON or OFF via the arrow buttons.
– Confirm your entry with the "OK" button.
In the example the setting "On" has been selected.
– Press the menu button to switch to menu level "Special functions".
Special functions
– Press the menu button again to switch to the operating mode.
Table 4: Sequence of operating steps
Product manual 2CKA001473B8291
│
32
advertisement
Related manuals
advertisement
Table of contents
- 4 Notes on the instruction manual
- 5 Safety
- 5 Information and symbols used
- 6 Intended use
- 6 Improper use
- 7 Target group / Qualifications of personnel
- 7 Operation
- 7 Installation, commissioning and maintenance
- 8 Safety instructions
- 9 Information on protection of the environment
- 9 Environment
- 10 Setup and function
- 10 Features of function and equipment
- 10 Control elements
- 11 Technical data
- 12 Connection, installation / mounting
- 12 Requirements for the electrician
- 13 Mounting/dismantling
- 15 Electrical connection
- 16 Commissioning
- 17 Operation
- 17 Notes on operation
- 18 Operating modes
- 19 Normal operation
- 19 Display
- 20 Button assignment
- 21 Device settings
- 22 Menu tree
- 24 Language
- 25 RESET (Resetting the device)
- 25 RESET (resetting to the factory settings)
- 26 Setting the starting / switching times
- 26 General
- 27 Block programming
- 29 Calling up special functions
- 29 MAX and MIN values
- 31 Valve protection
- 32 Standby times
- 33 OFFSET
- 34 Button lock
- 35 Date / Time
- 37 Adjust temperature
- 39 Display during mains power failure
- 40 Maintenance
- 40 Cleaning
- 41 Index