Display during mains power failure. Busch-Jaeger 1098 U-101, 1098 UF-101
Add to My manuals42 Pages
Busch-Jaeger 1098 UF-101 is an electronic room temperature controller that offers precise temperature regulation for heating systems or electric floor heating. With its user-friendly interface and advanced features, it provides flexibility and comfort for managing indoor temperatures. Here's a brief overview of its capabilities:
-
Time-controlled temperature regulation: The device allows you to set specific heating schedules, ensuring optimal temperatures at desired times.
-
Simple operation: The clear display and intuitive button layout make it easy to navigate and adjust settings.
-
Energy-saving modes: The standby and valve protection functions help optimize energy consumption by automatically reducing heating when not needed.
advertisement
![Display during mains power failure. Busch-Jaeger 1098 U-101, 1098 UF-101 | Manualzz Display during mains power failure. Busch-Jaeger 1098 U-101, 1098 UF-101 | Manualzz](http://s2.manualzz.com/store/data/063824174_1-24c47186fe4d9b620e77bd884a9ea84b-360x466.png)
8.7 Display during mains power failure
Operation
The illustration on the right shows an example of a display with the mains voltage activated.
Fig. 19: Display during normal operation
Fig. 20: Display during mains power failure
The illustration above shows the display during a mains voltage failure or the control element unplugged. Prerequisite, however, is that the temperature controller was charged previously for several hours.
The flashing plug symbol (see magnification) shows that the mains voltage supply to the temperature controller is deactivated. The time continues to run in the background, but is not displayed to save energy.
If the temperature controller is again supplied by the mains network within a period of 10 hours, the current time will be shown in the display.
Operation of the unplugged control element
If the control element (the temperature controller) was unplugged for programming, the menu level must first be called up with a long press of the button.
Operation is then carried out as normal.
Product manual 2CKA001473B8291
│
39
advertisement
Related manuals
advertisement
Table of contents
- 4 Notes on the instruction manual
- 5 Safety
- 5 Information and symbols used
- 6 Intended use
- 6 Improper use
- 7 Target group / Qualifications of personnel
- 7 Operation
- 7 Installation, commissioning and maintenance
- 8 Safety instructions
- 9 Information on protection of the environment
- 9 Environment
- 10 Setup and function
- 10 Features of function and equipment
- 10 Control elements
- 11 Technical data
- 12 Connection, installation / mounting
- 12 Requirements for the electrician
- 13 Mounting/dismantling
- 15 Electrical connection
- 16 Commissioning
- 17 Operation
- 17 Notes on operation
- 18 Operating modes
- 19 Normal operation
- 19 Display
- 20 Button assignment
- 21 Device settings
- 22 Menu tree
- 24 Language
- 25 RESET (Resetting the device)
- 25 RESET (resetting to the factory settings)
- 26 Setting the starting / switching times
- 26 General
- 27 Block programming
- 29 Calling up special functions
- 29 MAX and MIN values
- 31 Valve protection
- 32 Standby times
- 33 OFFSET
- 34 Button lock
- 35 Date / Time
- 37 Adjust temperature
- 39 Display during mains power failure
- 40 Maintenance
- 40 Cleaning
- 41 Index