www.pro-team.com. ProTeam 107251, 107252

Add to My manuals
44 Pages

advertisement

www.pro-team.com. ProTeam 107251, 107252 | Manualzz

Handle

IMPACT BUMPER INSTALLATION

1.

Using a Phillips Head screwdriver, remove screw from cord wrap bracket. Discard screw only.

Old Washer

2.

Place new washer on new screw and insert into impact bumper. Place old washer on end of screw.

Note: Make sure spring is installed as shown above.

39

3.

Insert impact bumper assembly into cord wrap bracket.

Note: Screw should be inserted inside spring from

original assembly. Do not over tighten.

www.pro-team.com 866.888.2168

ASSEMBLY

(a)

(b)

(c)

Wand

Hose Assembly with Cuffs

WAND AND HOSE APPLY TO

XP MODELS ONLY

Handle with Over

Mold and Decal

Quick

Release

Hose

Cuff

Cord Wrap

Screw

Handle

Tube

Bushing

Power Cord

Handle

Assembly

Screw

Carry Handle with

Tool Caddy

Cord Wrap Post

Final Vacuum Assembly

1.

2.

3.

Install all 3 filters:

(a) Intercept Micro Filter

(b) Motor Intake Filter

(c) Exhaust Filter

Install Power Cord and Handle with

Over Mold and Decal.

Attach with Handle Tube Bushing and

Carry Handle with Tool Caddy.

Wrap Power Cord around

Cord Wrap Post.

www.pro-team.com 866.888.2168 40

Troubleshooting

CLEARING HOSE AND WAND OBSTRUCTIONS – XP MODELS

R

E

S E T

T

SE

E

CLEARING THE BRUSH ROLL

Obstructions such as hair, string, and throw rugs may cause the red brush indicator light to be illuminated and the power nozzle to shut off.

1.

Turn off vacuum and unplug power cord from outlet.

2.

On underside of vacuum, pull out, or cut away, obstructions on the brush roll. (Figure A)

Figure A

Airflow path and possible obstruction locations

3.

Press the reset button on top side of powerhead. Plug-in power cord, and restart motor (Figure A).

F

IG

.

1

Quick release tabs

F

IG

. 2

CLEARING HOSE & WAND

Obstructions in hoses and wands may reduce or eliminate suction.

1.

Familiarize yourself with air flow path and possible obstruction locations

(Figure B).

2.

To determine obstruction location, remove wand from port. (Figure C). Turn on vacuum and place hand over wand opening to check for proper suction.

If no suction exists, blockage is at location A or B (as shown in Figure B) and proceed to Step 3. If there is proper suction, the blockage is at location C or

D (as shown in Figure B) and proceed to Step 5.

Figure B

F

IG

. 3

Lower air duct

3.

4.

Open Bag Housing Cover (F

IG

. 1) and replace Intercept Micro Filter. A full filter will restrict airflow.

Wand opening

Wand port

Figure C

Wand port

Wand guide

Lower air duct

Figure D

5.

6.

7.

Remove hose from the bag housing cover by using the quick release tabs.

(F

IG

. 2). Look into upper hose and wand. Shake or insert broom handle to clear any visible debris. Replace hose and wand on vacuum.

If blockage is not in the wand or upper hose, disconnect the lower air duct hose on the back of the power nozzle (F

IG

3). Visually check the lower air duct hose for debris and remove. To check for unobstructed air flow, turn on vacuum and place hand over opening on lower air duct. If you feel proper suction, reconnect lower air duct and resume vacuuming. If blockage is not in lower air duct hose, proceed to step 6.

With bottom air duct hose and upper hose and wand disconnected, carefully insert a broom handle (or any similar item like a short length of hose, pipe, etc) approximately 14 inches into wand guide on top of vacuum housing

(Figure D) to dislodge obstruction or debris. Debris should then drop or move into the lower air duct hose where you can then remove it with your hand

(F

IG

3).

Reconnect the lower air duct hose and upper hose assembly, and turn on the vacuum.

41 www.pro-team.com 866.888.2168

Troubleshooting

CLEARING HOSE AND WAND OBSTRUCTIONS – HEPA MODELS

CLEARING THE BRUSH ROLL

Obstructions such as hair, string, and throw rugs may cause the red brush indicator light to be illuminated and the power nozzle to shut off.

1.

Turn off vacuum and unplug power cord from outlet.

2.

On underside of vacuum, pull out, or cut away, obstructions on the brush roll. (Figure A).

Figure A

R

E

S E T

T

SE

E

3.

Press the reset button on top side of powerhead. Plug-in power cord, and restart motor. (Figure A).

Figure B

CLEARING HOSE & WAND

Obstructions in hoses and wands may reduce or eliminate suction.

1.

Turn off vacuum and unplug power cord from outlet

2.

Open Bag Housing Cover (Figure B) and replace Intercept Micro Filter. A full filter will restrict airflow.

3.

Disconnect the lower air duct hose on the back of the power nozzle

(Figure C). Visually check the lower air duct hose for debris and remove.

Figure C

4.

To check for unobstructed air flow, turn on vacuum with bag housing cover closed and place hand over opening on lower air duct (Figure C). If you feel prope suction, reconnect lower air duct and resume vacuuming.

If blockage is not in lower air duct hose, proceed to step 5.

Port

5.

Carefully insert a broom handle (or any similar item like a short length of hose, pipe, etc ) approximately 14 inches into guide on top of vacuum housing (Figure D) to dislodge obstruction or debris. Debris should then drop or move into the lower air duct where you can then remove it with your hand.

Guide

6.

Reconnect the lower air duct and upper hose assembly. Close bag housing cover and power on the vacuum.

Lower air duct

Figure D

www.pro-team.com 866.888.2168 42

P.O. Box 7385, Boise, Idaho 83707 • 866.888.2168

www.pro-team.com

#106243 Revised 12/12

advertisement

Related manuals