29.1 Dynamic equivalence point titrations (DET) ■■■■■■■■■■■■■■■■■■■■■■

29.1.6 Sensor

The parameters for the sensor are edited under [Sensor] .

Measuring input

Selection of the measuring input the sensor is connected to. The selection is not dependent on whether the control device has one or two measuring interfaces.

Selection

Default value

1 | 2

1

Sensor

Selection of the sensor from the sensor list. The selection depends on the measuring mode. Sensors are defined under System ▶ Sensors . You can also enter a sensor name which is not contained in the sensor list. When a determination is started there is a check whether the sensor is contained in the sensor list.

Selection Selection of configured sensors

I(pol)

The polarization current is the current that is applied to a polarizable electrode during voltametric measurement. This parameter is available only with I(pol) determinations.

The values that are actually adjustable may vary from the values specified here, depending on the hardware. The binding values can be found in the

Technical specifications chapter for the control instrument used.

Input range

Default value

Selection

–125.0 to 125.0 µA (Increment: 2.5)

5.0 µA

–1.0 µA | 1.0 µA

U(pol)

The polarization voltage is the voltage applied to the polarizable electrode during an amperometric measurement. This parameter is available only with U(pol) determinations.

The values that are actually adjustable may vary from the values specified here, depending on the hardware. The binding values can be found in the

Technical specifications chapter for the control instrument used.

Input range

Default value

–1,250 to 1,250 mV (Increment: 25)

400 mV

292 ■■■■■■■■ 900 Touch Control

advertisement

Key Features

  • Dynamic equivalence point titration (DET)
  • Monotonic equivalence point titration (MET)
  • Endpoint titration (SET)
  • Water determination according to Karl Fischer (KFT)
  • Titration with constant maintenance of the measured value (STAT)
  • Manual titration (MAT)
  • Coulometric water content determination according to Karl Fischer (KFC)
  • Bromine index determination (BRC)
  • Intuitive touch-sensitive screen for easy operation
  • Comprehensive user administration for secure data management

Related manuals

Frequently Answers and Questions

What is the purpose of the Metrohm 900 Touch Control?
The Metrohm 900 Touch Control is an advanced titration and measuring instrument used for various analytical chemistry applications, including titrations, water content determination, and more.
What are the key advantages of using the Metrohm 900 Touch Control?
The Metrohm 900 Touch Control offers high precision, versatility, and ease of use, making it an ideal choice for both routine and complex analytical tasks.
What types of titration methods does the Metrohm 900 Touch Control support?
The Metrohm 900 Touch Control supports various titration methods, including dynamic equivalence point titration (DET), monotonic equivalence point titration (MET), endpoint titration (SET), and more.
Can I use the Metrohm 900 Touch Control for water content determination?
Yes, the Metrohm 900 Touch Control can perform water content determination according to Karl Fischer (KFT) and coulometric water content determination according to Karl Fischer (KFC).
How do I ensure accurate and reliable results with the Metrohm 900 Touch Control?
The Metrohm 900 Touch Control offers GLP compliance features, ensuring the reliability and auditability of your results.