29.10.4 Control instrument. Metrohm 900 Touch Control

Add to My manuals
553 Pages

advertisement

29.10.4 Control instrument. Metrohm 900 Touch Control | Manualzz

29.10 Calibration of sensors (CAL) ■■■■■■■■■■■■■■■■■■■■■■

29.10.4 Control instrument

The control instrument the determination is carried out with is selected under [Control device] . Control instruments are defined under System ▶ Device manager .

NOTICE

This button is only displayed when several control instruments have been configured.

Control device

Selection of the control instrument from the list of devices. Only those devices are displayed which are able to carry out the command. The control instruments do not have to be connected. This allows to transfer methods more easily from one system to another.

Selection Selection of configured control instruments

29.10.5 Sensor

The parameters for the sensor are edited under [Sensor] .

Measuring input

Selection of the measuring input the sensor is connected to. The selection is not dependent on whether the control device has one or two measuring interfaces.

Selection

Default value

1 | 2

1

Sensor

Selection of the sensor from the sensor list. The selection depends on the measuring mode. Sensors are defined under System ▶ Sensors . You can also enter a sensor name which is not contained in the sensor list. When a determination is started there is a check whether the sensor is contained in the sensor list.

Selection Selection of configured sensors

Electrode check on | off (Default value: off )

This parameter is available only for the command CAL pH .

For the following electrodes, an electrode check can be carried out:

■ pH electrodes

400 ■■■■■■■■ 900 Touch Control

advertisement

Key Features

  • Dynamic equivalence point titration (DET)
  • Monotonic equivalence point titration (MET)
  • Endpoint titration (SET)
  • Water determination according to Karl Fischer (KFT)
  • Titration with constant maintenance of the measured value (STAT)
  • Manual titration (MAT)
  • Coulometric water content determination according to Karl Fischer (KFC)
  • Bromine index determination (BRC)
  • Intuitive touch-sensitive screen for easy operation
  • Comprehensive user administration for secure data management

Related manuals

Frequently Answers and Questions

What is the purpose of the Metrohm 900 Touch Control?
The Metrohm 900 Touch Control is an advanced titration and measuring instrument used for various analytical chemistry applications, including titrations, water content determination, and more.
What are the key advantages of using the Metrohm 900 Touch Control?
The Metrohm 900 Touch Control offers high precision, versatility, and ease of use, making it an ideal choice for both routine and complex analytical tasks.
What types of titration methods does the Metrohm 900 Touch Control support?
The Metrohm 900 Touch Control supports various titration methods, including dynamic equivalence point titration (DET), monotonic equivalence point titration (MET), endpoint titration (SET), and more.
Can I use the Metrohm 900 Touch Control for water content determination?
Yes, the Metrohm 900 Touch Control can perform water content determination according to Karl Fischer (KFT) and coulometric water content determination according to Karl Fischer (KFC).
How do I ensure accurate and reliable results with the Metrohm 900 Touch Control?
The Metrohm 900 Touch Control offers GLP compliance features, ensuring the reliability and auditability of your results.