Configuring UNIVERGE UM8500 for the integration. Mitel 8500


Add to my manuals
352 Pages

advertisement

Configuring UNIVERGE UM8500 for the integration. Mitel 8500 | Manualzz

Programming system data ASYD

System Index Bit

2 6

7

238

246

400 b0–7 b3 b2 b0 b1

Value Description

0

0

1

1

0

Lamp flash rate

MCI expansion set to normal

Calling number information sent to MCI

MCI in service when terminating to a UCD group

MCI out of service when terminating to attendant console

Programming system data local data ASYDL

System Index Bit

1 641

832

833 b1 b0–7 b0 b1

Value Description

0/1 0/1: MCI/IMX station number/phone number

00–FD Assign the FPC of the node connected to MC

0 IOC serial interface enabled for MCI

0 0/1: ICS/IMX format

NEC UNIVERGE SV8500

WITH SERIAL

MCI 263

Configuring

UNIVERGE

UM8500 for the integration

After ensuring that the voice mail server is ready for the integration by completing all appropriate tasks in the Installation Guide, perform the following procedure to confirm that the integration is enabled.

To confirm that the integration is enabled

1 Click Start > All Programs > UNIVERGE UM8500 > Edit Switch .

2 If prompted for logon credentials, type the administrator extension and password, then click OK .

On a new install the logon credentials are:

Extension = 99995

Password = 12345

3 Confirm that the settings match those in the following tables.

Phone system settings for integrations with digital ports

Parameter Required setting

Manufacturer NEC

Integration NEAX2400 IMS

Switch PBX software version 4203 and later with digital boards and MCI

Integration Serial

Phone system settings with IP Terminal or IP-VPS ports

Parameter Required setting

Manufacturer

Integration

NEC

NEAX2400 IMS

Switch PBX software version Software release 16 or later with

IP ports

Integration Serial

4 If the settings are incorrect, select the correct settings and click

Update

Voice Mail Now

.

Configuring UNIVERGE UM8500 ports

Configure the UM8500 voice ports. The procedure used depends on the port type the system is using.

For IP-VPS or IP Terminal ports, see “ To configure IP-VPS or IP Terminal ports ” on page 264 .

For digital ports, see “ To configure Digital ports ” on page 265 .

To configure IP-VPS or IP Terminal ports

1 Stop the UNIVERGE UM8500.

2 Run VOIPAdmin.exe from Commserver\Utilities folder.

The VoipAdmin Tool appears.

3 Enter the PBX IP address.

4 Set the general functionality for the ports (VPS or Terminal.)

If the system has VPS ports, enter the

VPS Number

.

5 Under Manage ports, click Add to add a new port.

Enter the

Extension

and

Password

for each port.

If the system has VPS ports, enter the VPS Channel for each port.

6 If the system uses one or more IP PADs, under Manage Gateways, click

Add

.

264 UNIVERGE UM8500 I NTEGRATION G UIDE

Enter the

IP Address and set the

Has DSP

to 0 for each gateway.

7 Click OK to save the changes and then close VOIPAdmin.

8 Restart UNIVERGE UM8500.

To configure Digital ports

1 Make sure that UNIVERGE UM8500 is running.

2 In Internet Explorer, go to the UM8500 Administrator http://<server name>/saweb

3 Go to

System > Ports

. Type the extension of each port. These extensions must be introduced as station numbers, not logical numbers and without the office codes, if they have any. Save the changes.

NEC UNIVERGE SV8500

WITH SERIAL

MCI 265

266 UNIVERGE UM8500 I NTEGRATION G UIDE