5 Mounting

Mounting 73

Pos: 74. 1 /Seri e 75 0 (WAGO I/O SYSTEM )/ Monti ere n/De monti ere n/Einba ulag e @ 3 \mo d_1 225 446 8183 12_ 21. docx @ 24 903 @ 2 @ 1

5.1 Installation Position

Along with horizontal and vertical installation, all other installation positions are allowed.

Use an end stop in the case of vertical mounting!

In the case of vertical assembly, an end stop has to be mounted as an additional safeguard against slipping.

WAGO order no. 249-116 End stop for DIN 35 rail, 6 mm wide

WAGO order no. 249-117 End stop for DIN 35 rail, 10 mm wide

Pos: 74. 2 /Seri e 75 0 (WAGO I/O SYSTEM )/ Monti ere n/De monti ere n/Ges amt ausb au @ 3\m od_ 123 176 409 946 8_21 .docx @ 2 594 0 @ 2 @ 1

5.2 Overall Configuration

The maximum total length of a fieldbus node without fieldbus coupler/controller is

780 mm including end module. The width of the end module is 12 mm. When assembled, the I/O modules have a maximum length of 768 mm.

Examples:

• 64 I/O modules with a 12 mm width can be connected to a fieldbus coupler/controller.

• 32 I/O modules with a 24 mm width can be connected to a fieldbus coupler/controller.

Exception:

The number of connected I/O modules also depends on the type of fieldbus coupler/controller is used. For example, the maximum number of stackable I/O modules on one PROFIBUS DP/V1 fieldbus coupler/controller is 63 with no passive I/O modules and end module.

Observe maximum total length of a fieldbus node!

The maximum total length of a fieldbus node without fieldbus coupler/controller and without using a 750-628 I/O Module (coupler module for internal data bus extension) may not exceed 780 mm.

Also note the limitations of individual fieldbus couplers/controllers.

Manual

Version 1.2.2

74 Mounting WAGO I/O System 750

750-890 Controller Modbus TCP; G4; 2ETH; SD

Increase the total length using a coupler module for internal data bus extension!

You can increase the total length of a fieldbus node by using a 750-628 I/O

Module (coupler module for internal data bus extension). For such a configuration, attach a 750-627 I/O Module (end module for internal data bus extension) after the last I/O module of a module assembly. Use an RJ-45 patch cable to connect the I/O module to the coupler module for internal data bus extension of another module block.

This allows you to segment a fieldbus node into a maximum of 11 blocks with maximum of 10 I/O modules for internal data bus extension.

The maximum cable length between two blocks is five meters.

More information is available in the manuals for the 750-627 and 750-628 I/O

Modules.

Pos: 74. 3 /Dok ume ntati on all gem ein/Glie de rung sele ment e/- --Seit enwec hsel- -- @ 3\ mod_ 122 110 804 507 8_0. docx @ 21 810 @ @ 1

Manual

Version 1.2.2

advertisement

Key Features

  • High performance and large memory
  • Integrated PLC functionality
  • Support for various communication protocols
  • Wide range of connection possibilities
  • Suitable for complex automation tasks
  • Use in various industrial environments

Related manuals

Frequently Answers and Questions

What are the main benefits of using WAGO Controller Modbus TCP?
The main benefits include high performance, extensive memory, integrated PLC functionality, support for various communication protocols, wide range of connection possibilities, and suitability for complex automation tasks in various industrial environments.
What sets WAGO Controller Modbus TCP apart from similar devices?
Key features that distinguish this device from similar ones include its high performance, large memory, integrated PLC functionality, support for various communication protocols, wide range of connection possibilities, and suitability for complex automation tasks in various industrial environments.
Can WAGO Controller Modbus TCP be used for complex automation tasks?
Yes, the device is suitable for complex automation tasks thanks to its high performance, large memory, integrated PLC functionality, and support for various communication protocols.
Does WAGO Controller Modbus TCP support various communication protocols?
Yes, the device supports various communication protocols, enabling flexible and efficient implementation of automation solutions.
Can WAGO Controller Modbus TCP be used in various industrial environments?
Yes, the device is suitable for use in various industrial environments thanks to its wide range of connection possibilities and robust design.
Download PDF

advertisement

Table of contents