Inserting the Fieldbus Coupler/Controller. WAGO Controller Modbus TCP

Show HTML Add to My manuals
372 Pages

advertisement

Inserting the Fieldbus Coupler/Controller. WAGO Controller Modbus TCP | Manualzz

WAGO I/O System 750

750-890 Controller Modbus TCP; G4; 2ETH; SD

Pos: 74. 15 /Se rie 7 50 (WAGO I/ O SYSTEM)/ Mon tier en/De mon tier en/ Feldb usko pple r/Cont rolle r ein füg en @ 3\m od_ 123 416 8173 031 _21 .docx @ 2 7456 @ 3 @ 1

5.6.1 Inserting the Fieldbus Coupler/Controller

Mounting 79

1. When replacing the fieldbus coupler/controller for an already available fieldbus coupler/controller, position the new fieldbus coupler/controller so that the tongue and groove joints to the subsequent I/O module are engaged.

2. Snap the fieldbus coupler/controller onto the carrier rail.

3. Use a screwdriver blade to turn the locking disc until the nose of the locking disc engages behind the carrier rail (see the following figure). This prevents the fieldbus coupler/controller from canting on the carrier rail.

With the fieldbus coupler/controller snapped in place, the electrical connections for the data contacts and power contacts (if any) to the possible subsequent I/O module are established.

Pos: 74. 16 /Se rie 7 50 (WAGO I/ O SYSTEM)/ Mon tier en/De mon tier en/Ve rrieg elun g - Bild (e rweite rte r ECO) @ 3\ mod _123 176 951 970 3_2 1.doc x @ 2 597 9 @ @ 1

Figure 31: Release Tab of Extended ECO Fieldbus Coupler (Example)

Pos: 74. 17 /Se rie 7 50 (WAGO I/ O SYSTEM)/ Mon tier en/De mon tier en/ Feldb usko pple r/Cont rolle r e ntfe rne n @ 4 \mo d_1 239 1693 584 53_ 21.d ocx @ 303 30 @ 3 @ 1

5.6.2 Removing the Fieldbus Coupler/Controller

1. Use a screwdriver blade to turn the locking disc until the nose of the locking disc no longer engages behind the carrier rail.

2. Remove the fieldbus coupler/controller from the assembly by pulling the release tab.

Electrical connections for data or power contacts to adjacent I/O modules are disconnected when removing the fieldbus coupler/controller.

Pos: 74. 18 /D okum ent ation allge mein/ Gliede run gsele me nte/ ---Sei tenwe chsel --- @ 3\ mod _12 211 080 450 78_ 0.docx @ 2 181 0 @ @ 1

Manual

Version 1.2.2

advertisement

Key Features

  • High performance and large memory
  • Integrated PLC functionality
  • Support for various communication protocols
  • Wide range of connection possibilities
  • Suitable for complex automation tasks
  • Use in various industrial environments

Related manuals

Frequently Answers and Questions

What are the main benefits of using WAGO Controller Modbus TCP?
The main benefits include high performance, extensive memory, integrated PLC functionality, support for various communication protocols, wide range of connection possibilities, and suitability for complex automation tasks in various industrial environments.
What sets WAGO Controller Modbus TCP apart from similar devices?
Key features that distinguish this device from similar ones include its high performance, large memory, integrated PLC functionality, support for various communication protocols, wide range of connection possibilities, and suitability for complex automation tasks in various industrial environments.
Can WAGO Controller Modbus TCP be used for complex automation tasks?
Yes, the device is suitable for complex automation tasks thanks to its high performance, large memory, integrated PLC functionality, and support for various communication protocols.
Does WAGO Controller Modbus TCP support various communication protocols?
Yes, the device supports various communication protocols, enabling flexible and efficient implementation of automation solutions.
Can WAGO Controller Modbus TCP be used in various industrial environments?
Yes, the device is suitable for use in various industrial environments thanks to its wide range of connection possibilities and robust design.
Download PDF

advertisement

Table of contents