Process Data. WAGO Controller Modbus TCP

Show HTML Add to My manuals
372 Pages

advertisement

Process Data. WAGO Controller Modbus TCP | Manualzz

WAGO I/O System 750

750-890 Controller Modbus TCP; G4; 2ETH; SD

I/O Modules 285

13.2.1.8 8 Channel Digital Input Module PTC with Diagnostics and Output

Process Data

750-1425

The digital input module PTC provides via one logical channel 2 byte for the input and output process image.

The signal state of PTC inputs DI1 … DI8 is transmitted to the fieldbus coupler/controller via input data byte D0.

The fault conditions are transmitted via input data byte D1.

The channels 1 … 8 are switched on or off via the output data byte D1.

The output data byte D0 is reserved and always has the value “0“.

Table 209: 8 Channel Digital Input Module PTC with Diagnostics and Output Process Data

Input Process Image

Input Byte D0

Bit 7

Signal status

DI 8

Channel 8

Bit 6

Signal status

DI 7

Channel 7

Input Byte D1

Bit 7 Bit 6

Bit 5

Signal status

DI 6

Channel 6

Bit 5

Bit 4

Signal status

DI 5

Channel 5

Bit 4

Bit 3

Signal status

DI 4

Channel 4

Bit 3

Bit 2

Signal status

DI 3

Channel 3

Bit 2

Bit 1

Signal status

DI 2

Channel 2

Bit 1

Bit 0

Signal status

DI 1

Channel 1

Bit 0

Wire break

/short circuit

Data bit

DI 8

Channel 8

Wire break

/short circuit

Data bit

DI 7

Channel 7

Output Process Image

Output Byte D0

Bit 7 Bit 6

0 0

Output Byte D1

Bit 7 Bit 6

DI Off 8

Channel 8

*)

DI Off 7

Channel 7

*)

Wire break

/short circuit

Data bit

DI 6

Channel 6

Bit 5

0

Bit 5

DI Off 6

Channel 6

*)

Wire break

/short circuit

Data bit

DI 5

Channel 5

Bit 4

0

Bit 4

DI Off 5

Channel 5

*)

Wire break

/short circuit

Data bit

DI 4

Channel 4

Bit 3

0

Bit 3

DI Off 4

Channel 4

*)

Wire break

/short circuit

Data bit

DI 3

Channel 3

Bit 2

0

Bit 2

DI Off 3

Channel 3

*)

Wire break

/short circuit

Data bit

DI 2

Channel 2

Bit 1

0

Bit 1

DI Off 2

Channel 2

*)

Wire break

/short circuit

Data bit

DI 1

Channel 1

Bit 0

0

Bit 0

DI Off 1

Channel 1

*)

*) 0: Channel ON

1: Channel OFF

Manual

Version 1.2.2

advertisement

Key Features

  • High performance and large memory
  • Integrated PLC functionality
  • Support for various communication protocols
  • Wide range of connection possibilities
  • Suitable for complex automation tasks
  • Use in various industrial environments

Related manuals

Frequently Answers and Questions

What are the main benefits of using WAGO Controller Modbus TCP?
The main benefits include high performance, extensive memory, integrated PLC functionality, support for various communication protocols, wide range of connection possibilities, and suitability for complex automation tasks in various industrial environments.
What sets WAGO Controller Modbus TCP apart from similar devices?
Key features that distinguish this device from similar ones include its high performance, large memory, integrated PLC functionality, support for various communication protocols, wide range of connection possibilities, and suitability for complex automation tasks in various industrial environments.
Can WAGO Controller Modbus TCP be used for complex automation tasks?
Yes, the device is suitable for complex automation tasks thanks to its high performance, large memory, integrated PLC functionality, and support for various communication protocols.
Does WAGO Controller Modbus TCP support various communication protocols?
Yes, the device supports various communication protocols, enabling flexible and efficient implementation of automation solutions.
Can WAGO Controller Modbus TCP be used in various industrial environments?
Yes, the device is suitable for use in various industrial environments thanks to its wide range of connection possibilities and robust design.
Download PDF

advertisement

Table of contents