INSTALLATION

Fig. 4: Releasing the pump

10. PNEUMATIC CONNECTION

10.1. Connecting to the compressed air outlet (Fig. 3)

There is a G1/4“ outlet with internal thread (20) (or quick connection for Ø12 / 9 hose) for the connection of pressure hose in the rear upper part of the housing.

11. ELECTRICAL CONNECTION

The product is delivered with a cord equipped with a plug with earthing pin.

Keep the socket easily accessible to ensure that the device can be safely disconnected from the mains.

The corresponding circuit must be protected in the power distribution max. 16 A.

Risk of electric shock. it is necessary to follow all local electrotechnical regulations. The mains voltage and frequency must comply with the data stated on the device label.

Risk of fire and electric shock.

Electrical cable must not be in contact with hot compressor components.

Risk of fire and electric shock.

Electrical cord must not be broken.

12. COMMISSIONING

Make sure all transport stabilizers were removed.

Check that all pressurized air line connections are secure.

Check to ensure power is connected correctly to the compressor.

12/2019 19 NP-DK50 PLUS, 2V-MOBILE-A-4_12-2019-MD